Can the "FloTrac" really track flow in septic patients?

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURE; ARTERY COMPLIANCE; COMPUTER PROGRAM; DEVICE; EDITORIAL; HEART OUTPUT; HUMAN; PULMONARY ARTERY CATHETER; SEPSIS;

EID: 79953814133     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-010-2109-9     Document Type: Editorial
Times cited : (4)

References (10)
  • 1
    • 38549151697 scopus 로고    scopus 로고
    • Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period
    • DOI 10.1097/01.CCM.OB013E318161FEC4, PII 0000324620080200000010
    • Hamzaoui O, Monnet X, Richard C, Osman D, Chemla D, Teboul JL (2008) Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 36:434-440 (Pubitemid 351158616)
    • (2008) Critical Care Medicine , vol.36 , Issue.2 , pp. 434-440
    • Hamzaoui, O.1    Monnet, X.2    Richard, C.3    Osman, D.4    Chemla, D.5    Teboul, J.-L.6
  • 2
    • 62849122288 scopus 로고    scopus 로고
    • Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients
    • Monnet X, Osman D, Ridel C, Lamia B, Richard C, Teboul JL (2009) Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Crit Care Med 37:951-956
    • (2009) Crit Care Med , vol.37 , pp. 951-956
    • Monnet, X.1    Osman, D.2    Ridel, C.3    Lamia, B.4    Richard, C.5    Teboul, J.L.6
  • 3
    • 42449103530 scopus 로고    scopus 로고
    • Cardiac output measurement in patients undergoing liver transplantation: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    • table of contents
    • Biais M, Nouette-Gaulain K, Cottenceau V, Vallet A, Cochard JF, Revel P, Sztark F (2008) Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis. Anesth Analg 106:1480-1486 (table of contents)
    • (2008) Anesth Analg , vol.106 , pp. 1480-1486
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3    Vallet, A.4    Cochard, J.F.5    Revel, P.6    Sztark, F.7
  • 6
    • 77953245170 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output in septic patients: Different accuracy of pulse contour and uncalibrated pressure waveform devices
    • Monnet X, Anguel N, Naudin B, Jabot J, Richard C, Teboul JL (2010) Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices. Crit Care 14:R109
    • (2010) Crit Care , vol.14
    • Monnet, X.1    Anguel, N.2    Naudin, B.3    Jabot, J.4    Richard, C.5    Teboul, J.L.6
  • 7
    • 79953827557 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output monitoring: A multicenter validation of the third-generation software in septic patients
    • doi: 10.1007/s00134-010-2098-8
    • De Backer D, Marx G, Tan A, Junker C, Van Nuffelen M, Hüter L, Ching W, Michard F, Vincent J-L (2010) Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med. doi: 10.1007/s00134-010-2098-8
    • (2010) Intensive Care Med
    • De Backer, D.1    Marx, G.2    Tan, A.3    Junker, C.4    Van Nuffelen, M.5    Hüter, L.6    Ching, W.7    Michard, F.8    Vincent, J.-L.9
  • 8
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LA, Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15:85-91 (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 9
    • 77951636130 scopus 로고    scopus 로고
    • Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: Comparison between echocardiography and Vigileo/FloTrac device
    • Biais M, Vidil L, Sarrabay P, Cottenceau V, Revel P, Sztark F (2009) Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo/FloTrac device. Crit Care 13:R195
    • (2009) Crit Care , vol.13
    • Biais, M.1    Vidil, L.2    Sarrabay, P.3    Cottenceau, V.4    Revel, P.5    Sztark, F.6
  • 10
    • 0036796943 scopus 로고    scopus 로고
    • Cardiac output measurement: Is least invasive always the best?
    • Vincent JL, De Backer D (2002) Cardiac output measurement: is least invasive always the best? Crit Care Med 30:2380-2382
    • (2002) Crit Care Med , vol.30 , pp. 2380-2382
    • Vincent, J.L.1    De Backer, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.