-
2
-
-
0034513779
-
Electrode impedance: An indicator of electrode-tissue contact and lesion dimensions during linear ablation
-
DOI 10.1023/A:1026586119600
-
Zheng X, Walcott GP, Hall JA, Rollins DL, Smith WM, Kay GN, Ideker RE,: Electrode impedance: An indicator of electrode-tissue contact and lesion dimensions during linear ablation. J Interv Card Electrophysiol 2000; 4: 645-654. (Pubitemid 32066524)
-
(2000)
Journal of Interventional Cardiac Electrophysiology
, vol.4
, Issue.4
, pp. 645-654
-
-
Zheng, X.1
Walcott, G.P.2
Hall, J.A.3
Rollins, D.L.4
Smith, W.M.5
Kay, G.N.6
Ideker, R.E.7
-
3
-
-
0037937250
-
Assessment of myocardial lesion size during in vitro radio frequency catheter ablation
-
DOI 10.1109/TBME.2003.812161
-
He DS, Bosnos M, Mays MZ, Marcus F,: Assessment of myocardial lesion size during in vitro radio frequency catheter ablation. IEEE Trans Biomed Eng 2003; 50: 768-776. (Pubitemid 36723610)
-
(2003)
IEEE Transactions on Biomedical Engineering
, vol.50
, Issue.6
, pp. 768-776
-
-
He, D.S.1
Bosnos, M.2
Mays, M.Z.3
Marcus, F.4
-
4
-
-
79959276015
-
A novel technology to enhance RFCA for atrial fibrillation: Electrode-tissue contact assessment based on impedance phase angle
-
Holmes D, Cao H, Paul S, Puryear HA, Chinitz L,: A novel technology to enhance RFCA for atrial fibrillation: Electrode-tissue contact assessment based on impedance phase angle. Heart Rhythm 2007; 4 (5 Suppl 1): S68.
-
(2007)
Heart Rhythm
, vol.4
, Issue.5 SUPPL. 1
-
-
Holmes, D.1
Cao, H.2
Paul, S.3
Puryear, H.A.4
Chinitz, L.5
-
5
-
-
77956317168
-
Early assessment of biophysical parameters predicts lesion formation during rf energy delivery in vitro
-
Bosnos M, Guillen-Rodriguez JM, He DS, Marcus FI,: Early assessment of biophysical parameters predicts lesion formation during rf energy delivery in vitro. Pacing Clin Electrophysiol 2010; 33: 1082-1088.
-
(2010)
Pacing Clin Electrophysiol
, vol.33
, pp. 1082-1088
-
-
Bosnos, M.1
Guillen-Rodriguez, J.M.2
He, D.S.3
Marcus, F.I.4
-
6
-
-
70450201110
-
First in human validation of impedance-based catheter tip-to-tissue contact assessment in the left atrium
-
Piorkowski C, Sih H, Sommer P, Miller SP, Gaspar T, Teplitsky L, Hindricks G,: First in human validation of impedance-based catheter tip-to-tissue contact assessment in the left atrium. J Cardiovasc Electrophysiol 2009; 20: 1366-1373.
-
(2009)
J Cardiovasc Electrophysiol
, vol.20
, pp. 1366-1373
-
-
Piorkowski, C.1
Sih, H.2
Sommer, P.3
Miller, S.P.4
Gaspar, T.5
Teplitsky, L.6
Hindricks, G.7
-
7
-
-
0028942447
-
Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
-
Nakagawa H, Yamanashi WS, Pitha JV, Arruda M, Wang X, Ohtomo K, Beckman KJ, McClelland JH, Lazzara R, Jackman WM,: Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91: 2264-2273.
-
(1995)
Circulation
, vol.91
, pp. 2264-2273
-
-
Nakagawa, H.1
Yamanashi, W.S.2
Pitha, J.V.3
Arruda, M.4
Wang, X.5
Ohtomo, K.6
Beckman, K.J.7
McClelland, J.H.8
Lazzara, R.9
Jackman, W.M.10
-
8
-
-
7044286081
-
Biophysics of ablation: Application to technology
-
DOI 10.1046/j.1540-8167.2004.15102.x
-
Haines D,: Biophysics of ablation: Application to technology. J Cardiovasc Electrophysiol 2004; 15: S2-S11. (Pubitemid 39426030)
-
(2004)
Journal of Cardiovascular Electrophysiology
, vol.15
, Issue.10 SUPPL.
-
-
Haines, D.1
-
9
-
-
0024364286
-
Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall
-
DOI 10.1111/j.1540-8159.1989.tb05034.x
-
Haines DE, Watson DD,: Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall. Pacing Clin Electrophysiol 1989; 12: 962-976. (Pubitemid 19158807)
-
(1989)
PACE - Pacing and Clinical Electrophysiology
, vol.12
, Issue.6
, pp. 962-976
-
-
Haines, D.E.1
Watson, D.D.2
-
10
-
-
58149199929
-
Electrophysiological and histological assessment of transmurality after epicardial ablation using unipolar radiofrequency energy
-
Miyagi Y, Ishii Y, Nitta T, Ochi M, Shimizu K,: Electrophysiological and histological assessment of transmurality after epicardial ablation using unipolar radiofrequency energy. J Card Surg 2009; 24: 34-40.
-
(2009)
J Card Surg
, vol.24
, pp. 34-40
-
-
Miyagi, Y.1
Ishii, Y.2
Nitta, T.3
Ochi, M.4
Shimizu, K.5
-
11
-
-
0036630140
-
Simultaneous creation and evaluation of linear radiofrequency lesions
-
DOI 10.1023/A:1019553619013
-
van Rensburg H, Willems R, Holemans P, Anne W, Ector H, Heidbuchel H,: Simultaneous creation and evaluation of linear radiofrequency lesions. J Interv Card Electrophysiol 2002; 6: 215-224. (Pubitemid 35006132)
-
(2002)
Journal of Interventional Cardiac Electrophysiology
, vol.6
, Issue.3
, pp. 215-224
-
-
Van Rensburg, H.1
Willems, R.2
Holemans, P.3
Anne, W.4
Ector, H.5
Heidbuchel, H.6
-
12
-
-
0034842011
-
Electrogram-guided radiofrequency catheter ablation of atrial tissue: Comparison with thermometry-guide ablation
-
DOI 10.1023/A:1011408514531
-
Schwartzman D, Michele JJ, Trankiem CT, Ren JF,: Electrogram-guided radiofrequency catheter ablation of atrial tissue comparison with thermometry-guide ablation: Comparison with thermometry-guide ablation. J Interv Card Electrophysiol 2001; 5: 253-266. (Pubitemid 32843440)
-
(2001)
Journal of Interventional Cardiac Electrophysiology
, vol.5
, Issue.3
, pp. 253-266
-
-
Schwartzman, D.1
Michele, J.J.2
Trankiem, C.T.3
Ren, J.-F.4
-
13
-
-
0028812669
-
Estimation of temperature during radiofrequency catheter ablation using impedance measurements
-
Hartung WM, Burton ME, Deam AG, Walter PF, McTeague K, Langberg JJ,: Estimation of temperature during radiofrequency catheter ablation using impedance measurements. Pacing Clin Electrophysiol 1995; 18: 2017-2021.
-
(1995)
Pacing Clin Electrophysiol
, vol.18
, pp. 2017-2021
-
-
Hartung, W.M.1
Burton, M.E.2
Deam, A.G.3
Walter, P.F.4
McTeague, K.5
Langberg, J.J.6
-
14
-
-
0028864089
-
Relation between impedance and temperature during radiofrequency ablation of accessory pathways
-
Strickberger SA, Ravi S, Daoud E, Niebauer M, Man KC, Morady F,: Relation between impedance and temperature during radiofrequency ablation of accessory pathways. Am Heart J 1995; 130: 1026-1030.
-
(1995)
Am Heart J
, vol.130
, pp. 1026-1030
-
-
Strickberger, S.A.1
Ravi, S.2
Daoud, E.3
Niebauer, M.4
Man, K.C.5
Morady, F.6
-
15
-
-
24744434175
-
Anatomic relations between the esophagus and left atrium and relevance for ablation of atrial fibrillation
-
DOI 10.1161/CIRCULATIONAHA.105.551291
-
Sanchez-Quintana D, Cabrera JA, Climent V, Farre J, Mendonca MC, Ho SY,: Anatomic relations between the esophagus and left atrium and relevance for ablation of atrial fibrillation. Circulation 2005; 112: 1400-1405. (Pubitemid 41291764)
-
(2005)
Circulation
, vol.112
, Issue.10
, pp. 1400-1405
-
-
Sanchez-Quintana, D.1
Cabrera, J.A.2
Climent, V.3
Farre, J.4
De Mendonca, M.C.5
Ho, S.Y.6
-
16
-
-
23044477164
-
Assessment of temperature, proximity, and course of the esophagus during radiofrequency ablation within the left atrium
-
DOI 10.1161/CIRCULATIONAHA.104.509612
-
Cummings JE, Schweikert RA, Saliba WI, Burkhardt JD, Brachmann J, Gunther J, Schibgilla V, Verma A, Dery M, Drago JL, Kilicaslan F, Natale A,: Assessment of temperature, proximity, and course of the esophagus during radiofrequency ablation within the left atrium. Circulation 2005; 112: 459-464. (Pubitemid 41060784)
-
(2005)
Circulation
, vol.112
, Issue.4
, pp. 459-464
-
-
Cummings, J.E.1
Schweikert, R.A.2
Saliba, W.I.3
Burkhardt, J.D.4
Brachmann, J.5
Gunther, J.6
Schibgilla, V.7
Verma, A.8
Dery, M.9
Drago, J.L.10
Kilicaslan, F.11
Natale, A.12
-
17
-
-
70350599170
-
Effect of electrode orientation on lesion sizes produced by irrigated radiofrequency ablation catheters
-
Wood MA, Goldberg SM, Parvez B, Pathak V, Holland K, Ellenbogen AL, Han FT, Alexander D, Lau M, Reshko L, Goel A,: Effect of electrode orientation on lesion sizes produced by irrigated radiofrequency ablation catheters. J Cardiovasc Electrophysiol 2009; 20: 1262-1268.
-
(2009)
J Cardiovasc Electrophysiol
, vol.20
, pp. 1262-1268
-
-
Wood, M.A.1
Goldberg, S.M.2
Parvez, B.3
Pathak, V.4
Holland, K.5
Ellenbogen, A.L.6
Han, F.T.7
Alexander, D.8
Lau, M.9
Reshko, L.10
Goel, A.11
-
18
-
-
67650661934
-
Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus
-
Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N, Ikeda A, Pitha JV, Sharma T, Lazzara R, Jackman WM,: Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol 2008; 1: 354-362.
-
(2008)
Circ Arrhythm Electrophysiol
, vol.1
, pp. 354-362
-
-
Yokoyama, K.1
Nakagawa, H.2
Shah, D.C.3
Lambert, H.4
Leo, G.5
Aeby, N.6
Ikeda, A.7
Pitha, J.V.8
Sharma, T.9
Lazzara, R.10
Jackman, W.M.11
-
19
-
-
45149096795
-
A systematical analysis of in vivo contact forces on virtual catheter tip/tissue surface contact during cardiac mapping and intervention
-
DOI 10.1111/j.1540-8167.2008.01135.x
-
Okumura Y, Johnson SB, Bunch TJ, Henz BD, O'Brien CJ, Packer DL,: A systematical analysis of in vivo contact forces on virtual catheter tip/tissue surface contact during cardiac mapping and intervention. J Cardiovasc Electrophysiol 2008; 19: 632-640. (Pubitemid 351832288)
-
(2008)
Journal of Cardiovascular Electrophysiology
, vol.19
, Issue.6
, pp. 632-640
-
-
Okumura, Y.1
Johnson, S.B.2
Bunch, T.J.3
Henz, B.D.4
O'Brien, C.J.5
Packer, D.L.6
-
20
-
-
79959194738
-
Impedance phase angle optimizes electrode-tissue contact and is superior to contact force to predict rf lesion formation and tissue popping: Improving safety and efficacy of ablation using open irrigation catheters
-
Arruda M, Marak J, Cao H, Fish J, Miler S, Paul S, Armaganijan L, Puryear H, Natale A,: Impedance phase angle optimizes electrode-tissue contact and is superior to contact force to predict rf lesion formation and tissue popping: Improving safety and efficacy of ablation using open irrigation catheters. JACC 2008; 51 (10,S1): A27.
-
(2008)
JACC
, vol.51
, Issue.10
-
-
Arruda, M.1
Marak, J.2
Cao, H.3
Fish, J.4
Miler, S.5
Paul, S.6
Armaganijan, L.7
Puryear, H.8
Natale, A.9
|