메뉴 건너뛰기




Volumn 50, Issue 6, 2003, Pages 768-776

Assessment of myocardial lesion size during in vitro radio frequency catheter ablation

Author keywords

Arrhythmia; Catheter ablation; Impedance

Indexed keywords

CAPACITANCE; ELECTRODES; TEMPERATURE MEASUREMENT; TISSUE;

EID: 0037937250     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2003.812161     Document Type: Article
Times cited : (13)

References (14)
  • 2
    • 0030055768 scopus 로고    scopus 로고
    • Non-pharmacological treatment of supraventricular arrhythmias
    • M. E. Josephson and V. H. Schibgilla, "Non-pharmacological treatment of supraventricular arrhythmias," Eur. Heart J., vol. 17, pp. 26-34, 1996.
    • (1996) Eur. Heart J. , vol.17 , pp. 26-34
    • Josephson, M.E.1    Schibgilla, V.H.2
  • 3
    • 0028877525 scopus 로고
    • Biophysics and pathology of catheter energy delivery systems
    • S. Nath and D. E. Haines, "Biophysics and pathology of catheter energy delivery systems," Prog. Cardiovasc. Diseases, vol. 37, pp. 185-204, 1995.
    • (1995) Prog. Cardiovasc. Diseases , vol.37 , pp. 185-204
    • Nath, S.1    Haines, D.E.2
  • 4
    • 0038483073 scopus 로고    scopus 로고
    • Update on the biophysics and thermodynamics of radiofrequency ablation
    • S. Nath and M. J. Barber, "Update on the biophysics and thermodynamics of radiofrequency ablation," Cardiac Electrophysiol. Rev., vol. 4, pp. 407-411, 1997.
    • (1997) Cardiac Electrophysiol. Rev. , vol.4 , pp. 407-411
    • Nath, S.1    Barber, M.J.2
  • 7
    • 0029876336 scopus 로고    scopus 로고
    • Temperature-controlled radiofrequency current ablation - What temperature?
    • M. Schluter and K. H. Kuck, "Temperature-controlled radiofrequency current ablation - what temperature?," Eur. Heart J., vol. 17, pp. 327-329, 1996.
    • (1996) Eur. Heart J. , vol.17 , pp. 327-329
    • Schluter, M.1    Kuck, K.H.2
  • 8
    • 0025775063 scopus 로고
    • Assessment of effects of radiofrequency energy fields and thermister location in an electrode catheter on the accuracy of temperature measurement
    • L. T. Blouin, F. I. Marcus, and L. Lampe, "Assessment of effects of radiofrequency energy fields and thermister location in an electrode catheter on the accuracy of temperature measurement," Pacing Clin. Electrophysiol., vol. 14, pp. 807-813, 1991.
    • (1991) Pacing Clin. Electrophysiol. , vol.14 , pp. 807-813
    • Blouin, L.T.1    Marcus, F.I.2    Lampe, L.3
  • 10
    • 0019508262 scopus 로고
    • Early phase acute myocardial infarct size quantification: Validation of the triphenyl tetrazolium chloride tissue enzyme staining technique
    • M. C. Fishbein, S. Meerbaum, J. Rit, U. Londo, K. Kanmatsuse, J.-C. Mercier, E. Corday, and W. Ganz, "Early phase acute myocardial infarct size quantification: validation of the triphenyl tetrazolium chloride tissue enzyme staining technique," Amer. Heart J., vol. 101, pp. 593-600, 1981.
    • (1981) Amer. Heart J. , vol.101 , pp. 593-600
    • Fishbein, M.C.1    Meerbaum, S.2    Rit, J.3    Londo, U.4    Kanmatsuse, K.5    Mercier, J.-C.6    Corday, E.7    Ganz, W.8
  • 11
    • 0027942161 scopus 로고
    • Ultrastructural observations in the myocardium beyond the region of acute coagulation necrosis following radiofrequency catheter ablation
    • S. Nath, J. A. Redick, J. G. Whayne, and D. E. Haines, "Ultrastructural observations in the myocardium beyond the region of acute coagulation necrosis following radiofrequency catheter ablation," J. Cardiovasc. Electrophysiol., vol. 5, pp. 838-845, 1994.
    • (1994) J. Cardiovasc. Electrophysiol. , vol.5 , pp. 838-845
    • Nath, S.1    Redick, J.A.2    Whayne, J.G.3    Haines, D.E.4
  • 13
    • 0033956518 scopus 로고    scopus 로고
    • Popping phenomena in temperature-controlled readiofrequency ablation: When and why do they occur?
    • J. E. Olaf, B. Gerritse, and B. Schumacher, "Popping phenomena in temperature-controlled readiofrequency ablation: when and why do they occur?," Pacing Clin. Electrophysiol., vol. 23, pp. 253-258, 2000.
    • (2000) Pacing Clin. Electrophysiol. , vol.23 , pp. 253-258
    • Olaf, J.E.1    Gerritse, B.2    Schumacher, B.3
  • 14
    • 0035208277 scopus 로고    scopus 로고
    • Comparison of irrigated electrode designs for radiofrequency ablation of myocardium
    • D. Demazumder, M. S. Mirotznik, and D. Schwartzman, "Comparison of irrigated electrode designs for radiofrequency ablation of myocardium," J. Intervent. Cardiac Electrophysiol., vol. 5, pp. 391-400, 2001.
    • (2001) J. Intervent. Cardiac Electrophysiol. , vol.5 , pp. 391-400
    • Demazumder, D.1    Mirotznik, M.S.2    Schwartzman, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.