메뉴 건너뛰기




Volumn 28 B, Issue 3, 2003, Pages 263-266

Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOMECHANICS; BONE SCREW; CADAVER; COMPARATIVE STUDY; CONTROLLED STUDY; DISEASE CLASSIFICATION; EXPERIMENTAL MODEL; FOREARM; FRACTURE REDUCTION; HAND PALM; HUMAN; KIRSCHNER WIRE; LOAD CARRYING CAPACITY; OSTEOTOMY; PILOT STUDY; PLATE FIXATION; RADIUS FRACTURE; WEIGHT BEARING; WRIST;

EID: 0038627493     PISSN: 02667681     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0266-7681(03)00011-1     Document Type: Article
Times cited : (111)

References (16)
  • 1
    • 0025364276 scopus 로고
    • Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius
    • Axelrod TS, McMurtry RY (1990). Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius. Journal of Hand Surgery, 15A: 1-11.
    • (1990) Journal of Hand Surgery , vol.15 A , pp. 1-11
    • Axelrod, T.S.1    McMurtry, R.Y.2
  • 2
    • 0032467256 scopus 로고    scopus 로고
    • Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures
    • Carter PR, Frederick HA, Laseter GF (1998). Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures. Journal of Hand Surgery, 23A: 300-307.
    • (1998) Journal of Hand Surgery , vol.23 A , pp. 300-307
    • Carter, P.R.1    Frederick, H.A.2    Laseter, G.F.3
  • 3
    • 0037798433 scopus 로고    scopus 로고
    • Comminuted intra-articular fracture of the distal radius - The technique of open reduction and internal fixation with plating
    • Chow SP, Ip WY and Poon TL (1999). Comminuted intra-articular fracture of the distal radius - The technique of open reduction and internal fixation with plating. Hand Surgery, 4: 175-180.
    • (1999) Hand Surgery , vol.4 , pp. 175-180
    • Chow, S.P.1    Ip, W.Y.2    Poon, T.L.3
  • 4
    • 0028631945 scopus 로고
    • Fractures of the distal radius: Classification of treatment and indications for external fixation
    • Graff S, Jupiter J (1994). Fractures of the distal radius: Classification of treatment and indications for external fixation. Injury, 25 (Suppl 4): 15-25.
    • (1994) Injury , vol.25 , Issue.SUPPL. 4 , pp. 15-25
    • Graff, S.1    Jupiter, J.2
  • 5
    • 0025216870 scopus 로고
    • Clinical and microangiographic studies on rupture of the E.P.L. tendon after distal radius fracture
    • Hirasawa Y, Katsumi Y, Akiyoshi T, Tamai K, Todioka T (1990). Clinical and microangiographic studies on rupture of the E.P.L. tendon after distal radius fracture. Journal of Hand Surgery (Br), 15B: 51-57.
    • (1990) Journal of Hand Surgery (Br) , vol.15 B , pp. 51-57
    • Hirasawa, Y.1    Katsumi, Y.2    Akiyoshi, T.3    Tamai, K.4    Todioka, T.5
  • 6
    • 0031050030 scopus 로고    scopus 로고
    • Open reduction and internal fixation of displaced intra-articular fractures of the distal radius: 31 patients followed for 3 to 7 years
    • Hove LM, Nilsen PT, Fumes O, Oulie HE, Solheim E, Moister AO (1997). Open reduction and internal fixation of displaced intra-articular fractures of the distal radius: 31 patients followed for 3 to 7 years. Acta Orthopaedica Scandinavica, 68: 59-63.
    • (1997) Acta Orthopaedica Scandinavica , vol.68 , pp. 59-63
    • Hove, L.M.1    Nilsen, P.T.2    Fumes, O.3    Oulie, H.E.4    Solheim, E.5    Moister, A.O.6
  • 7
    • 0026335623 scopus 로고
    • Current concepts review: Fractures of the distal end of the radius
    • Jupiter JB (1991). Current concepts review: Fractures of the distal end of the radius. Journal of Bone and Joint Surgery, 73A: 461-469.
    • (1991) Journal of Bone and Joint Surgery , vol.73 A , pp. 461-469
    • Jupiter, J.B.1
  • 8
    • 0036241905 scopus 로고    scopus 로고
    • Palmar plating for dorsally displaced fractures of the distal radius
    • Kamano M, Honda Y, Kazuki K, Yasuda M (2002). Palmar plating for dorsally displaced fractures of the distal radius. Clinical Orthopaedics, 397: 403-408.
    • (2002) Clinical Orthopaedics , vol.397 , pp. 403-408
    • Kamano, M.1    Honda, Y.2    Kazuki, K.3    Yasuda, M.4
  • 9
    • 0032460038 scopus 로고    scopus 로고
    • Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report
    • Kambouroglou GK, Axelrod TS (1998). Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report. Journal of Hand Surgery, 23A: 737-741.
    • (1998) Journal of Hand Surgery , vol.23 A , pp. 737-741
    • Kambouroglou, G.K.1    Axelrod, T.S.2
  • 10
    • 0034574860 scopus 로고    scopus 로고
    • Conservative treatment of intra-articular fractures of the distal radius - Factors affecting functional outcome
    • Leung F, Ozkan M, Chow SP (2000). Conservative treatment of intra-articular fractures of the distal radius - Factors affecting functional outcome. Hand Surgery, 5(2): 145-153.
    • (2000) Hand Surgery , vol.5 , Issue.2 , pp. 145-153
    • Leung, F.1    Ozkan, M.2    Chow, S.P.3
  • 11
    • 0032720912 scopus 로고    scopus 로고
    • Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the palmar surface of the distal radius
    • Nunley JA, Rowan PR (1999). Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the palmar surface of the distal radius. Journal of Hand Surgery, 24A: 1279-1280.
    • (1999) Journal of Hand Surgery , vol.24 A , pp. 1279-1280
    • Nunley, J.A.1    Rowan, P.R.2
  • 12
    • 0036130725 scopus 로고    scopus 로고
    • Palmar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    • Orbay JL, Fernandez DL (2002). Palmar fixation for dorsally displaced fractures of the distal radius: A preliminary report. Journal of Hand Surgery, 27A: 205-215.
    • (2002) Journal of Hand Surgery , vol.27 A , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2
  • 13
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures
    • Ring D, Jupiter JB, Brenwald J, Buchler U, Hastings H II (1997). Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. Journal of Hand Surgery, 22A: 777-784.
    • (1997) Journal of Hand Surgery , vol.22 A , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brenwald, J.3    Buchler, U.4    Hastings H. II5
  • 15
    • 0023127661 scopus 로고
    • Forearm force transmission after surgical treatment of distal radioulnar joint disorders
    • Trumble T, Glisson RR, Seaber AV and Urbaniak JR (1987). Forearm force transmission after surgical treatment of distal radioulnar joint disorders. Journal of Hand Surgery, 12A: 196-201.
    • (1987) Journal of Hand Surgery , vol.12 A , pp. 196-201
    • Trumble, T.1    Glisson, R.R.2    Seaber, A.V.3    Urbaniak, J.R.4
  • 16
    • 0038475115 scopus 로고    scopus 로고
    • A cadaver model for biomechanical study of fixation methods of AO type C2 distal radius fracture
    • in press
    • Zhu L, Ho H, Lu WW, Leung F, Chow SP (2002). A cadaver model for biomechanical study of fixation methods of AO type C2 distal radius fracture. Hand Surgery, in press.
    • (2002) Hand Surgery
    • Zhu, L.1    Ho, H.2    Lu, W.W.3    Leung, F.4    Chow, S.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.