메뉴 건너뛰기




Volumn 22, Issue 5, 2011, Pages 455-463

Comparison of two early loading protocols in full arch reconstructions in the edentulous maxilla using the Cresco prosthetic system: A three-arm parallel group randomized-controlled trial

Author keywords

Alveolar bone loss; Cantilever units; Dental implants; Edentulous jaw; Fixed prosthesis; Marginal bone level; Radiographic evaluation; Randomized clinical trial

Indexed keywords

AGED; ALVEOLAR BONE LOSS; ARTICLE; BONE DENSITY; BONE REGENERATION; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DENTAL CARE; DENTURE; EDENTULOUSNESS; FEASIBILITY STUDY; FEMALE; FOLLOW UP; HUMAN; JAW; MALE; MASTICATION; MAXILLA; METHODOLOGY; MIDDLE AGED; MULTICENTER STUDY; PATHOLOGY; PATIENT SATISFACTION; PERIIMPLANTITIS; PERIODONTICS; PHYSIOLOGY; RANDOMIZED CONTROLLED TRIAL; SINGLE BLIND PROCEDURE; TASTE; TOOTH IMPLANTATION; TOOTH PLAQUE; TOOTH PROSTHESIS; TOOTH RADIOGRAPHY;

EID: 79953729331     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2010.02156.x     Document Type: Article
Times cited : (11)

References (40)
  • 1
    • 0038176376 scopus 로고    scopus 로고
    • Early functional loading at 5 days for Brånemark implants placed into edentulous mandibles
    • a prospective, open-ended, longitudinal study.
    • Becker, W., Becker, B.E. & Huffstetler, S. (2003) Early functional loading at 5 days for Brånemark implants placed into edentulous mandibles: a prospective, open-ended, longitudinal study. Journal of Periodontolology 74: 695-702.
    • (2003) Journal of Periodontolology , vol.74 , pp. 695-702
    • Becker, W.1    Becker, B.E.2    Huffstetler, S.3
  • 2
    • 0032082470 scopus 로고    scopus 로고
    • Use of radiographs in evaluating success, stability and failure in implant dentistry
    • Brägger, U. (1998) Use of radiographs in evaluating success, stability and failure in implant dentistry. Periodontolology 2000 17: 77-88.
    • (1998) Periodontolology 2000 , vol.17 , pp. 77-88
    • Brägger, U.1
  • 6
    • 0033140443 scopus 로고    scopus 로고
    • In vivo bone response to biomechanical loading at the bone/dental-implant interface
    • Brunski, J.B. (1999) In vivo bone response to biomechanical loading at the bone/dental-implant interface. Advances in Dental Research 13: 99-119.
    • (1999) Advances in Dental Research , vol.13 , pp. 99-119
    • Brunski, J.B.1
  • 7
    • 0035228432 scopus 로고    scopus 로고
    • Immediate loading of implant- fixed mandibular prostheses
    • a prospective 18-month follow-up clinical study - preliminary report.
    • Colomina, L.E. (2001) Immediate loading of implant- fixed mandibular prostheses: a prospective 18-month follow-up clinical study - preliminary report. Implant Dentistry 10: 23-29.
    • (2001) Implant Dentistry , vol.10 , pp. 23-29
    • Colomina, L.E.1
  • 9
    • 0037264870 scopus 로고    scopus 로고
    • Interventions for replacing missing teeth
    • different times for loading dental implants. Issue 3, Art. No.: CD003878, doi: DOI: 10.1002/14651858.CD003878.pub2.
    • Esposito, M., Worthington, H.V., Thomsen, P. & Coulthard, P. (2004) Interventions for replacing missing teeth: different times for loading dental implants. Cochrane Database of Systematic Reviews Issue 3, Art. No.: CD003878, doi: DOI: 10.1002/14651858.CD003878.pub2.
    • (2004) Cochrane Database of Systematic Reviews
    • Esposito, M.1    Worthington, H.V.2    Thomsen, P.3    Coulthard, P.4
  • 10
    • 0038519775 scopus 로고    scopus 로고
    • Immediate loading of Brånemark implants
    • a 24-month follow-up of a comparative prospective pilot study between mandibular overdentures supported by conical transmucosal and standard MKII implants.
    • Gatti, C. & Chiapasco, M. (2002) Immediate loading of Brånemark implants: a 24-month follow-up of a comparative prospective pilot study between mandibular overdentures supported by conical transmucosal and standard MKII implants. Clinical Implant Dentistry & Related Research 4: 190-199.
    • (2002) Clinical Implant Dentistry & Related Research , vol.4 , pp. 190-199
    • Gatti, C.1    Chiapasco, M.2
  • 11
    • 0030155399 scopus 로고    scopus 로고
    • The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues
    • Hämmerle, C.H., Brägger, U., Bürgin, W. & Lang, N.P. (1996) The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues. Clinical Oral Implants Research 7: 111-119.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 111-119
    • Hämmerle, C.H.1    Brägger, U.2    Bürgin, W.3    Lang, N.P.4
  • 12
    • 0038505307 scopus 로고    scopus 로고
    • Cyclic loading of implant-supported prostheses
    • changes in component fit over time.
    • Hecker, D.M. & Eckert, S.E. (2003) Cyclic loading of implant-supported prostheses: changes in component fit over time. Journal of Prosthetic Dentistry 89: 346-351.
    • (2003) Journal of Prosthetic Dentistry , vol.89 , pp. 346-351
    • Hecker, D.M.1    Eckert, S.E.2
  • 13
    • 9644275499 scopus 로고    scopus 로고
    • Clinical performance of a method for the fabrication of implant-supported precisely fitting titanium frameworks
    • a retrospective 5- to 8-year clinical follow-up study.
    • Hedkvist, L., Mattsson, T. & Hellden, L.B. (2004) Clinical performance of a method for the fabrication of implant-supported precisely fitting titanium frameworks: a retrospective 5- to 8-year clinical follow-up study. Clinical Implant Dentistry & Related Research 6: 174-180.
    • (2004) Clinical Implant Dentistry & Related Research , vol.6 , pp. 174-180
    • Hedkvist, L.1    Mattsson, T.2    Hellden, L.B.3
  • 14
    • 33747070841 scopus 로고    scopus 로고
    • Feasibility and influence of the microgap of two implants placed in a non-submerged procedure
    • a five-year follow-up clinical trial.
    • Heijdenrijk, K., Raghoebar, G.M., Meijer, H.J., Stegenga, B. & van der Reijden, W.A. (2006) Feasibility and influence of the microgap of two implants placed in a non-submerged procedure: a five-year follow-up clinical trial. Journal of Periodontolology 77: 1051-1060.
    • (2006) Journal of Periodontolology , vol.77 , pp. 1051-1060
    • Heijdenrijk, K.1    Raghoebar, G.M.2    Meijer, H.J.3    Stegenga, B.4    van der Reijden, W.A.5
  • 16
    • 0033210999 scopus 로고    scopus 로고
    • The CrescoTi Precision method
    • description of a simplified method to fabricate titanium superstructures with passive fit to osseointegrated implants.
    • Helldén, L.B., Dérand, T., Johansson, S. & Lindberg, A. (1999) The CrescoTi Precision method: description of a simplified method to fabricate titanium superstructures with passive fit to osseointegrated implants. Journal of Prosthetetic Dentistry 82: 487-491.
    • (1999) Journal of Prosthetetic Dentistry , vol.82 , pp. 487-491
    • Helldén, L.B.1    Dérand, T.2    Johansson, S.3    Lindberg, A.4
  • 17
    • 0031262411 scopus 로고    scopus 로고
    • Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible
    • Hermann, J.S., Cochran, D.L., Nummikoski, P.V. & Buser, D. (1997) Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible. Journal of Periodontology 68: 1117-1130.
    • (1997) Journal of Periodontology , vol.68 , pp. 1117-1130
    • Hermann, J.S.1    Cochran, D.L.2    Nummikoski, P.V.3    Buser, D.4
  • 22
    • 0018589158 scopus 로고
    • Stegprothetische Versorgung des zahnlosen Unterkiefers mit Hilfe von plasmabeschichteten Titanischraubenimplanten
    • Ledermann, P.D. (1979) Stegprothetische Versorgung des zahnlosen Unterkiefers mit Hilfe von plasmabeschichteten Titanischraubenimplanten. Deutsche Zahnärztliche Zeitung 34: 907-911.
    • (1979) Deutsche Zahnärztliche Zeitung , vol.34 , pp. 907-911
    • Ledermann, P.D.1
  • 23
    • 0345964258 scopus 로고
    • The implant site
    • In: Linkow L.I. & Chercheve R., eds., St Louis: CV Mosby Company.
    • Linkow, L.I. & Cherchéve, R. (1970) The implant site. In: Linkow L.I. & Chercheve R., eds. Theories and Techniques of Oral Implantology, Volume I, 74-76. St Louis: CV Mosby Company.
    • (1970) Theories and Techniques of Oral Implantology , vol.1 , pp. 74-76
    • Linkow, L.I.1    Cherchéve, R.2
  • 24
    • 0023583441 scopus 로고
    • The microbiotica associated with success of or failing osseointegration of titanium implants
    • Mombelli, A., van Oosten, M.A., Schurch, E. Jr & Lang, N.P. (1987) The microbiotica associated with success of or failing osseointegration of titanium implants. Oral Microbiology and Immunology 2: 145-151.
    • (1987) Oral Microbiology and Immunology , vol.2 , pp. 145-151
    • Mombelli, A.1    van Oosten, M.A.2    Schurch Jr, E.3    Lang, N.P.4
  • 25
    • 34547361066 scopus 로고    scopus 로고
    • Early functional loading of sand-blasted and acid-etched (SLA) Straumann implants following immediate placement in maxillary extraction sockets. Clinical and radiographic result
    • Nordin, T., Graf, J., Frykholm, A. & Helldén, L. (2007) Early functional loading of sand-blasted and acid-etched (SLA) Straumann implants following immediate placement in maxillary extraction sockets. Clinical and radiographic result. Clinical Oral Implants Research 18: 441-451.
    • (2007) Clinical Oral Implants Research , vol.18 , pp. 441-451
    • Nordin, T.1    Graf, J.2    Frykholm, A.3    Helldén, L.4
  • 26
    • 0344629329 scopus 로고    scopus 로고
    • Early functional loading of unsplinted roughened surface implants with mandibular overdentures 2 weeks after surgery
    • Payne, A.G., Tawse-Smith, A., Thompson, W.M. & Kumara, R. (2003) Early functional loading of unsplinted roughened surface implants with mandibular overdentures 2 weeks after surgery. Clinical Implant Dentistry & Related Research 5: 143-153.
    • (2003) Clinical Implant Dentistry & Related Research , vol.5 , pp. 143-153
    • Payne, A.G.1    Tawse-Smith, A.2    Thompson, W.M.3    Kumara, R.4
  • 27
    • 0346787866 scopus 로고    scopus 로고
    • Four-year follow-up of larger-diameter implants placed in fresh extraction sockets using a resorbable membrane or a resorbable alloplastic material
    • Prosper, L., Gherlone, E.F., Redaelli, S. & Quaranta, M. (2003) Four-year follow-up of larger-diameter implants placed in fresh extraction sockets using a resorbable membrane or a resorbable alloplastic material. The International Journal of Oral & Maxillofacial Implants 18: 856-864.
    • (2003) The International Journal of Oral & Maxillofacial Implants , vol.18 , pp. 856-864
    • Prosper, L.1    Gherlone, E.F.2    Redaelli, S.3    Quaranta, M.4
  • 28
    • 0041511733 scopus 로고    scopus 로고
    • Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations
    • a retrospective 3-year clinical study.
    • Rocci, A., Martignoni, M. & Gottlow, J. (2003a) Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: a retrospective 3-year clinical study. Clinical Implant Dentistry & Related Research 5 SUPPL. 1): 29-36.
    • (2003) Clinical Implant Dentistry & Related Research , vol.5 , Issue.SUPPL. 1 , pp. 29-36
    • Rocci, A.1    Martignoni, M.2    Gottlow, J.3
  • 29
    • 0042012775 scopus 로고    scopus 로고
    • Immediate loading of Brånemark System TiUnite and machined-surface implants in the posterior mandible
    • a randomized open-ended clinical trial.
    • Rocci, A., Martignoni, M. & Gottlow, J. (2003b) Immediate loading of Brånemark System TiUnite and machined-surface implants in the posterior mandible: a randomized open-ended clinical trial. Clinical Implant Dentistry & Related Research 5 SUPPL. 1): 57-63.
    • (2003) Clinical Implant Dentistry & Related Research , vol.5 , Issue.SUPPL. 1 , pp. 57-63
    • Rocci, A.1    Martignoni, M.2    Gottlow, J.3
  • 30
    • 0035650821 scopus 로고    scopus 로고
    • Early loading of sandblasted and acid-etched (SLA) implants
    • a prospective split-mouth comparative study.
    • Roccuzzo, M., Bunino, M., Prioglio, F. & Bianchi, S.D. (2001) Early loading of sandblasted and acid-etched (SLA) implants: a prospective split-mouth comparative study. Clinical Oral Implants Research 12: 572-578.
    • (2001) Clinical Oral Implants Research , vol.12 , pp. 572-578
    • Roccuzzo, M.1    Bunino, M.2    Prioglio, F.3    Bianchi, S.D.4
  • 32
    • 0035223781 scopus 로고    scopus 로고
    • The significance of passive framework fit in implant prosthodontics
    • current status.
    • Sahin, S. & Cehreli, M.C. (2001) The significance of passive framework fit in implant prosthodontics: current status. Implant Dentistry 10: 85-92.
    • (2001) Implant Dentistry , vol.10 , pp. 85-92
    • Sahin, S.1    Cehreli, M.C.2
  • 33
    • 0038350018 scopus 로고    scopus 로고
    • The influence of functional forces on the biomechanics of implant-supported prostheses - a review
    • Sahin, S., Cehreli, M.C. & Yalçin, E. (2002) The influence of functional forces on the biomechanics of implant-supported prostheses - a review. Journal of Dentistry 30: 271-282.
    • (2002) Journal of Dentistry , vol.30 , pp. 271-282
    • Sahin, S.1    Cehreli, M.C.2    Yalçin, E.3
  • 34
    • 67650359881 scopus 로고    scopus 로고
    • Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique-a comparative in vivo study
    • Schmitt, J., Holst, S., Eitner, S., Schlegel, A., Wichmann, M. & Hamel, J. (2009) Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique-a comparative in vivo study. The International Journal of Prosthodontics 22: 193-200.
    • (2009) The International Journal of Prosthodontics , vol.22 , pp. 193-200
    • Schmitt, J.1    Holst, S.2    Eitner, S.3    Schlegel, A.4    Wichmann, M.5    Hamel, J.6
  • 36
    • 0038749490 scopus 로고    scopus 로고
    • Bone healing following immediate versus delayed placement of titanium implants into extraction sockets
    • a prospective clinical study.
    • Schropp, L., Kostopoulos, L. & Wenzel, A. (2003) Bone healing following immediate versus delayed placement of titanium implants into extraction sockets: a prospective clinical study. The International Journal of Oral & Maxillofacial Implants 18: 189-199.
    • (2003) The International Journal of Oral & Maxillofacial Implants , vol.18 , pp. 189-199
    • Schropp, L.1    Kostopoulos, L.2    Wenzel, A.3
  • 37
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler, S., Piattelli, A., Favero, G.A. & Dubruille, J.H. (2000) Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clinical Oral Implants Research 11: 12-25.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 38
    • 0036365690 scopus 로고    scopus 로고
    • Early loading of unsplinted implants supporting mandibular overdentures using a one-stage operative procedure with two different implant systems
    • a 2-year report.
    • Tawse-Smith, A., Payne, A.G., Kumara, R. & Thomson, W.M. (2002) Early loading of unsplinted implants supporting mandibular overdentures using a one-stage operative procedure with two different implant systems: a 2-year report. Clinical Implant Dentistry & Related Research 4: 33-42.
    • (2002) Clinical Implant Dentistry & Related Research , vol.4 , pp. 33-42
    • Tawse-Smith, A.1    Payne, A.G.2    Kumara, R.3    Thomson, W.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.