메뉴 건너뛰기




Volumn 173, Issue 1-2, 2011, Pages 267-273

Determination of Se(IV) using solidified floating organic drop microextraction coupled to ultrasound-assisted back-extraction and hydride generation atomic fluorescence spectrometry

Author keywords

Hydride generation atomic fluorescence spectrometry; Se(IV); Solidified floating organic drop microextraction; Ultrasound assisted back extraction

Indexed keywords


EID: 79953667194     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-011-0574-7     Document Type: Article
Times cited : (26)

References (32)
  • 1
    • 33747048067 scopus 로고    scopus 로고
    • On-line pre-reduction of Se(VI) by thiourea for selenium speciation by hydride generation
    • Qiu JH, Wang QQ, Ma YN, Yang LM, Huang BL (2006) On-line pre-reduction of Se(VI) by thiourea for selenium speciation by hydride generation. Spectrochim Acta B 61: 803.
    • (2006) Spectrochim Acta B , vol.61 , pp. 803
    • Qiu, J.H.1    Wang, Q.Q.2    Ma, Y.N.3    Yang, L.M.4    Huang, B.L.5
  • 2
    • 0026513429 scopus 로고
    • Utilization of two different chemical forms of selenium during lactation using stable isotope tracers: an example of speciation in nutrition
    • Moser-veilon PB, Reeds Mangels A, Patterson KY, Veillon C (1992) Utilization of two different chemical forms of selenium during lactation using stable isotope tracers: an example of speciation in nutrition. Analyst 117: 559.
    • (1992) Analyst , vol.117 , pp. 559
    • Moser-Veilon, P.B.1    Reeds Mangels, A.2    Patterson, K.Y.3    Veillon, C.4
  • 3
    • 58649107864 scopus 로고    scopus 로고
    • Novel approaches for selenium speciation in foodstuffs and biological specimens: a review
    • Pedrero Z, Madrid Y (2009) Novel approaches for selenium speciation in foodstuffs and biological specimens: a review. Anal Chim Acta 634: 135.
    • (2009) Anal Chim Acta , vol.634 , pp. 135
    • Pedrero, Z.1    Madrid, Y.2
  • 4
    • 0037112387 scopus 로고    scopus 로고
    • Simultaneous monitoring of volatile selenium and sulfur species from Se accumulating plants (wild type and genetically modified) by GC/MS and GC/ICPMS using solid-phase microextraction for sample introduction
    • Meija J, Montes-Bayón M, Le Duc DL, Terry N, Caruso JA (2002) Simultaneous monitoring of volatile selenium and sulfur species from Se accumulating plants (wild type and genetically modified) by GC/MS and GC/ICPMS using solid-phase microextraction for sample introduction. Anal Chem 74: 5837.
    • (2002) Anal Chem , vol.74 , pp. 5837
    • Meija, J.1    Montes-Bayón, M.2    Le Duc, D.L.3    Terry, N.4    Caruso, J.A.5
  • 5
    • 0037782421 scopus 로고    scopus 로고
    • Multisyringe flow injection system for total inorganic selenium determination by hydride generation-atomic fluorescence spectrometry
    • Semenova NV, Leal LO, Forteza R, Cerdà V (2003) Multisyringe flow injection system for total inorganic selenium determination by hydride generation-atomic fluorescence spectrometry. Anal Chim Acta 486: 217.
    • (2003) Anal Chim Acta , vol.486 , pp. 217
    • Semenova, N.V.1    Leal, L.O.2    Forteza, R.3    Cerdà, V.4
  • 6
    • 0035942533 scopus 로고    scopus 로고
    • Speciation of Se(IV) and the selenoamino acids by high-performance liquid chromatography-direct hydride generation-atomic fluorescence spectrometry
    • Ipolyi I, Stefánka Zs, Fodor P (2001) Speciation of Se(IV) and the selenoamino acids by high-performance liquid chromatography-direct hydride generation-atomic fluorescence spectrometry. Anal Chim Acta 435: 367.
    • (2001) Anal Chim Acta , vol.435 , pp. 367
    • Ipolyi, I.1    Stefánka, Z.2    Fodor, P.3
  • 7
    • 0032049235 scopus 로고    scopus 로고
    • Direct determination of dissolved selenium(IV) and selenium(VI) in sea-water by continuous flow hydride generation atomic fluorescence spectrometry
    • He YZ, Moreda-Piñeiro J, Cervera ML, Guardia MDL (1998) Direct determination of dissolved selenium(IV) and selenium(VI) in sea-water by continuous flow hydride generation atomic fluorescence spectrometry. J Anal At Spectrom 13: 289.
    • (1998) J Anal At Spectrom , vol.13 , pp. 289
    • He, Y.Z.1    Moreda-Piñeiro, J.2    Cervera, M.L.3    Guardia, M.D.L.4
  • 8
    • 70350732793 scopus 로고    scopus 로고
    • 2 controlled volatilization for speciation analysis of inorganic selenium using HPLC-AFS
    • 2 controlled volatilization for speciation analysis of inorganic selenium using HPLC-AFS. Microchim Acta 167: 141.
    • (2009) Microchim Acta , vol.167 , pp. 141
    • Liu, Q.Y.1
  • 9
    • 0032495220 scopus 로고    scopus 로고
    • Co-precipitative pre-concentration with sodium diethyldithiocarbamate and ICP-AES determination of Se, Cu, Pb, Zn, Fe, Co, Ni, Mn, Cr and Cd in water
    • Atanassova D, Stefanova V, Russeva E (1998) Co-precipitative pre-concentration with sodium diethyldithiocarbamate and ICP-AES determination of Se, Cu, Pb, Zn, Fe, Co, Ni, Mn, Cr and Cd in water. Talanta 47: 1237.
    • (1998) Talanta , vol.47 , pp. 1237
    • Atanassova, D.1    Stefanova, V.2    Russeva, E.3
  • 10
    • 34548208740 scopus 로고    scopus 로고
    • Fast determination of arsenic, selenium, nickel and vanadium in fish and shellfish by electrothermal atomic absorption spectrometry following ultrasound-assisted extraction
    • Lavilla I, Vilas P, Bendicho C (2008) Fast determination of arsenic, selenium, nickel and vanadium in fish and shellfish by electrothermal atomic absorption spectrometry following ultrasound-assisted extraction. Food Chem 106: 403.
    • (2008) Food Chem , vol.106 , pp. 403
    • Lavilla, I.1    Vilas, P.2    Bendicho, C.3
  • 11
    • 0037134992 scopus 로고    scopus 로고
    • Solid-phase extraction for the simultaneous preconcentration of organic (selenocystine) and inorganic [Se(IV), Se(VI)] selenium in natural waters
    • Bueno M, Potin-Gautier M (2002) Solid-phase extraction for the simultaneous preconcentration of organic (selenocystine) and inorganic [Se(IV), Se(VI)] selenium in natural waters. J Chromatogr A 963: 185.
    • (2002) J Chromatogr A , vol.963 , pp. 185
    • Bueno, M.1    Potin-Gautier, M.2
  • 13
    • 77949429952 scopus 로고    scopus 로고
    • Speciation analysis of As, Sb and Se in leachates of cementitious construction materials using selective solid phase extraction and ICP-MS
    • Mulugeta M, Wibetoe G, Engelsen CJ, Lund W (2010) Speciation analysis of As, Sb and Se in leachates of cementitious construction materials using selective solid phase extraction and ICP-MS. J Anal At Spectrom 25: 169.
    • (2010) J Anal At Spectrom , vol.25 , pp. 169
    • Mulugeta, M.1    Wibetoe, G.2    Engelsen, C.J.3    Lund, W.4
  • 14
    • 34047262488 scopus 로고    scopus 로고
    • Inorganic speciation of As(III, V), Se(IV, VI) and Sb(III, V) in natural water with GF-AAS using solid phase extraction technology
    • Zhang L, Morita Y, Sakuragawa A, Isozaki A (2007) Inorganic speciation of As(III, V), Se(IV, VI) and Sb(III, V) in natural water with GF-AAS using solid phase extraction technology. Talanta 72: 723.
    • (2007) Talanta , vol.72 , pp. 723
    • Zhang, L.1    Morita, Y.2    Sakuragawa, A.3    Isozaki, A.4
  • 15
    • 34247514836 scopus 로고    scopus 로고
    • Total inorganic Se and Te preconcentration and their determination by on-line coupling of a solid-phase extraction procedure with HG-AAS
    • Gil RA, Kaplan MM, Salonia JA, Gasquez JA, Martinez LD (2007) Total inorganic Se and Te preconcentration and their determination by on-line coupling of a solid-phase extraction procedure with HG-AAS. At Spectrosc 28: 67.
    • (2007) At Spectrosc , vol.28 , pp. 67
    • Gil, R.A.1    Kaplan, M.M.2    Salonia, J.A.3    Gasquez, J.A.4    Martinez, L.D.5
  • 16
    • 55149089898 scopus 로고    scopus 로고
    • Selenium analysis in water samples by dispersive liquid-liquid microextraction based on piazselenol formation and GC-ECD
    • Bidari A, Hemmatkhah P, Jafarvand S, Milani Hosseini MR, Assadi Y (2008) Selenium analysis in water samples by dispersive liquid-liquid microextraction based on piazselenol formation and GC-ECD. Microchim Acta 163: 243.
    • (2008) Microchim Acta , vol.163 , pp. 243
    • Bidari, A.1    Hemmatkhah, P.2    Jafarvand, S.3    Milani Hosseini, M.R.4    Assadi, Y.5
  • 17
    • 77049085478 scopus 로고    scopus 로고
    • A novel solidified floating organic drop microextraction based on ultrasound-dispersion for separation and preconcentration of palladium in aqueous samples
    • Mohamadi M, Mostafavi A (2010) A novel solidified floating organic drop microextraction based on ultrasound-dispersion for separation and preconcentration of palladium in aqueous samples. Talanta 81: 309.
    • (2010) Talanta , vol.81 , pp. 309
    • Mohamadi, M.1    Mostafavi, A.2
  • 18
    • 33846629120 scopus 로고    scopus 로고
    • A new liquid-phase microextraction method based on solidification of floating organic drop
    • Khalili Zanjani MR, Yamini Y, Shariati S, Jönsson JÅ (2007) A new liquid-phase microextraction method based on solidification of floating organic drop. Anal Chim Acta 585: 286.
    • (2007) Anal Chim Acta , vol.585 , pp. 286
    • Khalili Zanjani, M.R.1    Yamini, Y.2    Shariati, S.3    Jönsson, J.4
  • 20
    • 77950123238 scopus 로고    scopus 로고
    • Evolution of dispersive liquid-liquid microextraction method
    • Rezaee M, Yamini Y, Faraji M (2010) Evolution of dispersive liquid-liquid microextraction method. J Chromatogr A 1217: 2342.
    • (2010) J Chromatogr A , vol.1217 , pp. 2342
    • Rezaee, M.1    Yamini, Y.2    Faraji, M.3
  • 21
    • 46749150902 scopus 로고    scopus 로고
    • A novel separation/preconcentration system based on solidification of floating organic drop microextraction for determination of lead by graphite furnace atomic absorption spectrometry
    • Dadfarnia S, Salmanzadeh AM, Haji Shabani AM (2008) A novel separation/preconcentration system based on solidification of floating organic drop microextraction for determination of lead by graphite furnace atomic absorption spectrometry. Anal Chim Acta 623: 163.
    • (2008) Anal Chim Acta , vol.623 , pp. 163
    • Dadfarnia, S.1    Salmanzadeh, A.M.2    Haji Shabani, A.M.3
  • 22
    • 75749110644 scopus 로고    scopus 로고
    • Solidified floating organic drop microextraction for determination of trace amounts of zinc in water samples by flame atomic absorption spectrometry
    • Ma JJ, Zhang JW, Du X, Lei X, Li JC (2010) Solidified floating organic drop microextraction for determination of trace amounts of zinc in water samples by flame atomic absorption spectrometry. Microchim Acta 168: 153.
    • (2010) Microchim Acta , vol.168 , pp. 153
    • Ma, J.J.1    Zhang, J.W.2    Du, X.3    Lei, X.4    Li, J.C.5
  • 23
    • 67650149852 scopus 로고    scopus 로고
    • Separation/preconcentration and determination of cadmium ions by solidification of floating organic drop microextraction and FI-AAS
    • Dadfarnia S, Haji Shabani AM, Kamranzadeh E (2009) Separation/preconcentration and determination of cadmium ions by solidification of floating organic drop microextraction and FI-AAS. Talanta 79: 1061.
    • (2009) Talanta , vol.79 , pp. 1061
    • Dadfarnia, S.1    Haji Shabani, A.M.2    Kamranzadeh, E.3
  • 24
    • 77951497714 scopus 로고    scopus 로고
    • A simple and rapid new dispersive liquid-liquid microextraction based on solidification of floating organic drop combined with inductively coupled plasma-optical emission spectrometry for preconcentration and determination of aluminium in water samples
    • Rezaee M, Yamini Y, Khanchi A, Faraji M, Saleh A (2010) A simple and rapid new dispersive liquid-liquid microextraction based on solidification of floating organic drop combined with inductively coupled plasma-optical emission spectrometry for preconcentration and determination of aluminium in water samples. J Hazard Mater 178: 766.
    • (2010) J Hazard Mater , vol.178 , pp. 766
    • Rezaee, M.1    Yamini, Y.2    Khanchi, A.3    Faraji, M.4    Saleh, A.5
  • 25
    • 75749083753 scopus 로고    scopus 로고
    • Determination of the steroid hormone levels in water samples by dispersive liquid-liquid microextraction with solidification of a floating organic drop followed by high-performance liquid chromatography
    • Chang CC, Huang SD (2010) Determination of the steroid hormone levels in water samples by dispersive liquid-liquid microextraction with solidification of a floating organic drop followed by high-performance liquid chromatography. Anal Chim Acta 662: 39.
    • (2010) Anal Chim Acta , vol.662 , pp. 39
    • Chang, C.C.1    Huang, S.D.2
  • 26
    • 54549109925 scopus 로고    scopus 로고
    • Dispersive liquid-liquid microextraction method based on solidification of floating organic drop combined with gas chromatography with electron-capture or mass spectrometry detection
    • Leong MI, Huang SD (2008) Dispersive liquid-liquid microextraction method based on solidification of floating organic drop combined with gas chromatography with electron-capture or mass spectrometry detection. J Chromatogr A 1211: 8.
    • (2008) J Chromatogr A , vol.1211 , pp. 8
    • Leong, M.I.1    Huang, S.D.2
  • 27
    • 70449448936 scopus 로고    scopus 로고
    • Pre-concentration of phenolic compounds in water samples by novel liquid-liquid microextraction and determination by gas chromatography-mass spectrometry
    • Faraji H, Tehrani MS, Husain SW (2009) Pre-concentration of phenolic compounds in water samples by novel liquid-liquid microextraction and determination by gas chromatography-mass spectrometry. J Chromatogr A 1216: 8569.
    • (2009) J Chromatogr A , vol.1216 , pp. 8569
    • Faraji, H.1    Tehrani, M.S.2    Husain, S.W.3
  • 28
    • 34548679376 scopus 로고    scopus 로고
    • Monitoring of selenium in water samples using dispersive liquid-liquid microextraction followed by iridium-modified tube graphite furnace atomic absorption spectrometry
    • Bidari A, Jahromi EZ, Assadi Y, Milani Hosseini MR (2007) Monitoring of selenium in water samples using dispersive liquid-liquid microextraction followed by iridium-modified tube graphite furnace atomic absorption spectrometry. Microchem J 87: 6.
    • (2007) Microchem J , vol.87 , pp. 6
    • Bidari, A.1    Jahromi, E.Z.2    Assadi, Y.3    Milani Hosseini, M.R.4
  • 29
    • 28844507820 scopus 로고    scopus 로고
    • A hydride generation atomic fluorescence spectrometric procedure for selenium determination after flow injection on-line co-precipitate preconcentration
    • Tang XD, Xu ZR, Wang JH (2005) A hydride generation atomic fluorescence spectrometric procedure for selenium determination after flow injection on-line co-precipitate preconcentration. Spectrochim Acta B 60: 1580.
    • (2005) Spectrochim Acta B , vol.60 , pp. 1580
    • Tang, X.D.1    Xu, Z.R.2    Wang, J.H.3
  • 30
    • 33847098706 scopus 로고    scopus 로고
    • On-line organoselenium interference removal for inorganic selenium species by flow injection coprecipitation preconcentration coupled with hydride generation atomic fluorescence spectrometry
    • Wu H, Jin Y, Shi YQ, Bi SP (2007) On-line organoselenium interference removal for inorganic selenium species by flow injection coprecipitation preconcentration coupled with hydride generation atomic fluorescence spectrometry. Talanta 71: 1762.
    • (2007) Talanta , vol.71 , pp. 1762
    • Wu, H.1    Jin, Y.2    Shi, Y.Q.3    Bi, S.P.4
  • 31
    • 56949107791 scopus 로고    scopus 로고
    • Precipitate coating on cellulose fibre as sorption medium for selenium preconcentration and speciation with hydride generation atomic fluorescence spectrometry
    • Chen ML, Yang T, Wang JH (2009) Precipitate coating on cellulose fibre as sorption medium for selenium preconcentration and speciation with hydride generation atomic fluorescence spectrometry. Anal Chim Acta 631: 74.
    • (2009) Anal Chim Acta , vol.631 , pp. 74
    • Chen, M.L.1    Yang, T.2    Wang, J.H.3
  • 32
    • 1642340665 scopus 로고    scopus 로고
    • Flow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry using a polytetrafluoroethylene fiber-packed microcolumn for determination of Se(IV) in natural water
    • Lu CY, Yan XP, Zhang ZP, Wang ZP, Liu LW (2004) Flow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry using a polytetrafluoroethylene fiber-packed microcolumn for determination of Se(IV) in natural water. J Anal At Spectrom 19: 277.
    • (2004) J Anal At Spectrom , vol.19 , pp. 277
    • Lu, C.Y.1    Yan, X.P.2    Zhang, Z.P.3    Wang, Z.P.4    Liu, L.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.