Volumn 33, Issue 2, 2011, Pages 149-154

Evaluation of QMS everolimus assay using Hitachi 917 Analyzer: Comparison with liquid chromatography/mass spectrometry

Author keywords

everolimus; immunoassay; liquid chromatography mass spectrometry

Indexed keywords

ACICLOVIR; ALLOPURINOL; AMPHOTERICIN B; ATENOLOL; CAPTOPRIL; CEFACLOR; CIMETIDINE; CYCLOSPORIN A; ERYTHROMYCIN; EVEROLIMUS; FLUCONAZOLE; FUROSEMIDE; GENTAMICIN; HEPARIN; IBUPROFEN; ISONIAZID; ITRACONAZOLE; KETOCONAZOLE; LIDOCAINE; MEVINOLIN; MISOPROSTOL; NAPROXEN; NIFEDIPINE; PARACETAMOL; PHENYTOIN; PREDNISONE; RANITIDINE; RAPAMYCIN; TACROLIMUS; UNINDEXED DRUG;

EID: 79953194044     PISSN: 01634356     EISSN: 15363694     Source Type: Journal    
DOI: 10.1097/FTD.0b013e31820afc97     Document Type: Article
Times cited : (31)

References (16)
  • 1
    • 1642388492 scopus 로고    scopus 로고
    • Experience with everolimus
    • Augustine JJ, Hricik DE. Experience with everolimus. Transplant Proc. 2004;36(Suppl 2S):S500-S503.
    • (2004) Transplant Proc , vol.36 , Issue.SUPPL. 2S
    • Augustine, J.J.1    Hricik, D.E.2
  • 4
    • 0035958104 scopus 로고    scopus 로고
    • Rad in de novo renal transplantation: Comparison of three doses on the incidence and severity of acute rejection
    • Kahan BD, Kaplan B, Lorber MI, et al. RAD in de novo renal transplantation: comparison of three dosages on the incidence and severity of acute rejection. Transplantation. 2001;71:1400-1406. (Pubitemid 32507112)
    • (2001) Transplantation , vol.71 , Issue.10 , pp. 1400-1406
    • Kahan, B.D.1    Kaplan, B.2    Lorber, M.I.3    Winkler, M.4    Cambon, N.5    Boger, R.S.6
  • 6
    • 0036238215 scopus 로고    scopus 로고
    • Simultaneous quantification of sirolimus, everolimus, tacrolimus and cyclosporine by liquid chromatography-mass spectrometry (LC-MS)
    • DOI 10.1515/CCLM.2002.045
    • Deters M, Kirchner G, Resch K, et al. Simultaneous quantification of sirolimus, everolimus, tacrolimus and cyclosporine by liquid chromatography- mass spectrometry. Clin Chem Lab Med. 2002;40:285-292. (Pubitemid 34428858)
    • (2002) Clinical Chemistry and Laboratory Medicine , vol.40 , Issue.3 , pp. 285-292
    • Deters, M.1    Kirchner, G.2    Resch, K.3    Kaever, V.4
  • 8
    • 26444567404 scopus 로고    scopus 로고
    • The role of therapeutic monitoring of everolimus in solid organ transplantation
    • DOI 10.1097/01.ftd.0000175911.70172.2e
    • Mabasa VH, Ensom MH. The role of therapeutic drug monitoring of everolimus in solid organ transplantation. Ther Drug Monit. 2005;27: 666-676. (Pubitemid 41437646)
    • (2005) Therapeutic Drug Monitoring , vol.27 , Issue.5 , pp. 666-676
    • Mabasa, V.H.1    Ensom, M.H.H.2
  • 9
    • 0034306732 scopus 로고    scopus 로고
    • Automated fast and sensitive quantification of drugs in blood by liquid chromatography-mass spectrometry with on-line extraction: Immunosuppressants
    • Christians U, Jacobsen W, Serkova N, et al. Automated fast and sensitive quantification of drugs in blood by liquid chromatography-mass spectrometry with on-line extraction: immunosuppressants. J Chromatogr B. 2000;748:41-53.
    • (2000) J Chromatogr B , vol.748 , pp. 41-53
    • Christians, U.1    Jacobsen, W.2    Serkova, N.3
  • 10
    • 67649801479 scopus 로고    scopus 로고
    • Review of the newest HPLC methods with mass spectrometry detection for determination of immunosuppressive drugs in clinical practice
    • Korecha M, Shaw LM. Review of the newest HPLC methods with mass spectrometry detection for determination of immunosuppressive drugs in clinical practice. Ann Transplant. 2009;14:61-72.
    • (2009) Ann Transplant , vol.14 , pp. 61-72
    • Korecha, M.1    Shaw, L.M.2
  • 11
    • 77955174746 scopus 로고    scopus 로고
    • Liquid chromatography-tandem mass spectrometry outperforms fluorescence polarization immunoassay in monitoring everolimus therapy in renal transplantation
    • Moes DJ, Press RR, de Fijter JW, et al. Liquid chromatography-tandem mass spectrometry outperforms fluorescence polarization immunoassay in monitoring everolimus therapy in renal transplantation. Ther Drug Monit. 2010;32:413-419.
    • (2010) Ther Drug Monit , vol.32 , pp. 413-419
    • Moes, D.J.1    Press, R.R.2    De Fijter, J.W.3
  • 12
    • 16244402129 scopus 로고    scopus 로고
    • The relative proportions of sirolimus metabolites in blood using HPLC with mass-spectrometric detection
    • DOI 10.1016/j.transproceed.2004.12.005
    • Holt DW, McKeown DA, Lee TD, et al. The relative proportions of sirolimus metabolites in blood using HPLC with mass-spectrometric detection. Transplant Proc. 2004;36:3223-3225. (Pubitemid 41126778)
    • (2004) Transplantation Proceedings , vol.36 , Issue.10 , pp. 3223-3225
    • Holt, D.W.1    McKeown, D.A.2    Lee, T.D.3    Hicks, D.4    Cal, P.5    Johnston, A.6
  • 14
    • 70249140182 scopus 로고    scopus 로고
    • Multi-site analytical evaluation of a chemiluminescent microparticle immunoassay (CMIA) for sirolimus on the Abbott Architect analyzer
    • Schmid RW, Lotz J, Schweigert R, et al. Multi-site analytical evaluation of a chemiluminescent microparticle immunoassay (CMIA) for sirolimus on the Abbott Architect analyzer. Clin Biochem. 2009;42:1543-1548.
    • (2009) Clin Biochem , vol.42 , pp. 1543-1548
    • Schmid, R.W.1    Lotz, J.2    Schweigert, R.3
  • 15
    • 33745855121 scopus 로고    scopus 로고
    • Evaluation of a fluorescent polarization immunoassay for whole blood everolimus determination using samples from renal transplant recipients
    • DOI 10.1016/j.clinbiochem.2006.03.019, PII S000991200600141X
    • Salm P,Warnholtz C, Boyd J, et al. Evaluation of a fluorescence polarization immunoassay for whole blood everolimus determination using samples from renal transplant recipients. Clin Biochem. 2006;39:732-738. (Pubitemid 44036785)
    • (2006) Clinical Biochemistry , vol.39 , Issue.7 , pp. 732-738
    • Salm, P.1    Warnholtz, C.2    Boyd, J.3    Arabshahi, L.4    Marbach, P.5    Taylor, P.J.6
  • 16
    • 60449097232 scopus 로고    scopus 로고
    • Robust high throughput LC-MS/MS method for therapeutic drug monitoring of cyclosporine, tacrolimus, everolimus and sirolimus in whole blood
    • Koster RA, Dijkers EC, Uges DR. Robust high throughput LC-MS/MS method for therapeutic drug monitoring of cyclosporine, tacrolimus, everolimus and sirolimus in whole blood. Ther Drug Monit. 2009;31:116-125.
    • (2009) Ther Drug Monit , vol.31 , pp. 116-125
    • Koster, R.A.1    Dijkers, E.C.2    Uges, D.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.