메뉴 건너뛰기




Volumn 91, Issue 4, 2011, Pages 1001-1002

Industry-generated charts for the selection of stented aortic valve prostheses: Clinical tool or marketing ploy?

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; ECHOCARDIOGRAPHY; EDITORIAL; HEMODYNAMICS; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; STENT;

EID: 79953094173     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2011.01.051     Document Type: Editorial
Times cited : (19)

References (10)
  • 1
    • 0033819953 scopus 로고    scopus 로고
    • Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
    • P. Pibarot, and J.G. Dumesnil Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention J Am Coll Cardiol 36 2000 1131 1141
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1131-1141
    • Pibarot, P.1    Dumesnil, J.G.2
  • 2
    • 34247847791 scopus 로고    scopus 로고
    • Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: Which is the best method?
    • DOI 10.1136/hrt.2006.102764
    • S. Bleiziffer, W.B. Eichinger, and I. Hettich Prediction of valve prosthesispatient mismatch prior to aortic valve replacement: which is the best method? Heart 93 2007 615 620 (Pubitemid 46707117)
    • (2007) Heart , vol.93 , Issue.5 , pp. 615-620
    • Bleiziffer, S.1    Eichinger, W.B.2    Hettich, I.3    Guenzinger, R.4    Ruzicka, D.5    Bauernschmitt, R.6    Lange, R.7
  • 8
    • 34249010507 scopus 로고    scopus 로고
    • Carpentier-Edwards Perimount Magna Valve Versus Medtronic Hancock II: A Matched Hemodynamic Comparison
    • DOI 10.1016/j.athoracsur.2007.02.062, PII S0003497507004201
    • M.A. Borger, A.F. Nette, M. Maganti, and C.M. Feindel Carpentier-Edwards Perimount Magna valve versus Medtronic Hancock II: a matched hemodynamic comparison Ann Thorac Surg 83 2007 2054 2058 (Pubitemid 46782680)
    • (2007) Annals of Thoracic Surgery , vol.83 , Issue.6 , pp. 2054-2058
    • Borger, M.A.1    Nette, A.F.2    Maganti, M.3    Feindel, C.M.4
  • 9
    • 0036894369 scopus 로고    scopus 로고
    • Eleven years' experience with the Biocor stentless aortic bioprosthesis: Clinical and hemodynamic follow-up with long-term relative survival rate
    • DOI 10.1016/S1010-7940(02)00584-5, PII S1010794002005845
    • G. Dellgren, M.J. Ericksson, L.A. Brodin, and K. Radegran Eleven years' experience with the Biocor stentless aortic bioprosthesis: clinical and hemodynamic follow-up with long-term relative survival rate Eur J Cardiothorac Surg 22 2002 912 921 (Pubitemid 35430217)
    • (2002) European Journal of Cardio-thoracic Surgery , vol.22 , Issue.6 , pp. 912-921
    • Dellgren, G.1    Eriksson, M.J.2    Brodin, L.A.3    Radegran, K.4
  • 10
    • 77949995905 scopus 로고    scopus 로고
    • Hemodynamic performance of Mitroflow aortic pericardial bioprosthesisoptimizing management for the small aortic annulus
    • W.R.E. Jamieson, W.R. Forgie, and R.I. Hayden Hemodynamic performance of Mitroflow aortic pericardial bioprosthesisoptimizing management for the small aortic annulus Thorac Cardiovasc Surg 58 2010 69 75
    • (2010) Thorac Cardiovasc Surg , vol.58 , pp. 69-75
    • Jamieson, W.R.E.1    Forgie, W.R.2    Hayden, R.I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.