메뉴 건너뛰기




Volumn , Issue , 2010, Pages 1170-1175

The extraction technology of weak coupling AC signal in an electromagnetic localization system

Author keywords

[No Author keywords available]

Indexed keywords

AC SIGNALS; BONE SURGERY; COUPLING VOLTAGE; ELECTROMAGNETIC LOCALIZATION; ELECTROMAGNETIC METHODS; EXTRACTION TECHNOLOGY; FAST FOURIER TRANSFORMATIONS; FUNCTION FITTING; KEY PARTS; PHASE LOCK; REAL SYSTEMS; SENSING COILS; SURGICAL INSTRUMENT; WEAK COUPLINGS;

EID: 79952918480     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBIO.2010.5723494     Document Type: Conference Paper
Times cited : (14)

References (17)
  • 1
    • 79952954131 scopus 로고    scopus 로고
    • Research on navigation and positioning algorithm of Computer-assisted orthopedic trauma surgery arm
    • In Chinese
    • Manyi Wang. "Research on navigation and positioning algorithm of Computer-assisted orthopedic trauma surgery arm". Chinese Medical Journal, 2006, 86 (9) (In Chinese)
    • (2006) Chinese Medical Journal , vol.86 , Issue.9
    • Wang, M.1
  • 2
    • 79952923545 scopus 로고    scopus 로고
    • The application of Computer-assisted navigation orthopedic surgery and medical robotics in orthopedic trauma
    • In Chinese
    • Manyi Wang, Junqiang Wang. "The application of Computer-assisted navigation orthopedic surgery and medical robotics in orthopedic trauma". Chinese Journal of Traumatology,2005, 7 (11) (In Chinese)
    • (2005) Chinese Journal of Traumatology , vol.7 , Issue.11
    • Wang, M.1    Wang, J.2
  • 3
    • 84996476687 scopus 로고    scopus 로고
    • Application and progress in computer assisted orthopaedic surgery
    • In Chinese
    • Junqiang Wang, Lei Sun, Manyi Wang. "Application and progress in computer assisted orthopaedic surgery". Chinese Journal of Traumatology, 2004, 6 (1) (In Chinese)
    • (2004) Chinese Journal of Traumatology , vol.6 , Issue.1
    • Wang, J.1    Sun, L.2    Wang, M.3
  • 4
    • 55049130783 scopus 로고    scopus 로고
    • Mini-sized medical robot and computer-assisted localization for treatment of tibial fracture
    • Wang Man-yi. "Mini-sized medical robot and computer-assisted localization for treatment of tibial fracture". Journal of Clinical Rehabilitative Tissue Engineering Research, 2008,VOL 12.No.35
    • (2008) Journal of Clinical Rehabilitative Tissue Engineering Research , vol.12 , Issue.35
    • Wang, M.-Y.1
  • 5
    • 79952948470 scopus 로고
    • ISG Technologies - Introduced neurosurgical probe Viewing Wand
    • Dec
    • ISG Technologies - introduced neurosurgical probe Viewing Wand,Health Industry Today, Dec, 1993
    • (1993) Health Industry Today
  • 8
    • 79952964563 scopus 로고    scopus 로고
    • NORTHERN DIGITAL INC. NDI
    • NORTHERN DIGITAL INC. Optotrak manual, NDI, 2005.
    • (2005) Optotrak Manual
  • 13
    • 34247326032 scopus 로고
    • Tracking and determining orientation of object using coordinate transformation means, system and process
    • U.S. Patent 3 983 474, Sept.28
    • J. Kuipers, "Tracking and determining orientation of object using coordinate transformation means, system and process," U.S. Patent 3 983 474, Sept.28, 1976.
    • (1976)
    • Kuipers, J.1
  • 14
    • 4243299535 scopus 로고
    • Apparatus for generating a nutating electromagnetic field
    • U.S. Patent 4 107 858, Apr. 12
    • J. Kuipers, "Apparatus for generating a nutating electromagnetic field," U.S. Patent 4 107 858, Apr. 12, 1977.
    • (1977)
    • Kuipers, J.1
  • 16
    • 24844462925 scopus 로고
    • Remoteobjectandorientationlocator
    • U.S.Patent4 314 251,Feb.
    • F.H.Raab,"Remoteobjectandorientationlocator,"U.S.Patent4 314 251,Feb.1982.
    • (1982)
    • Raab, F.H.1
  • 17
    • 79952979187 scopus 로고    scopus 로고
    • http://blog.ednchina.com/nosaylove/127950/message.aspx.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.