메뉴 건너뛰기




Volumn 37, Issue 4, 2011, Pages 587-594

Focused-Ultrasound Disruption of the Blood-Brain Barrier Using Closely-Timed Short Pulses: Influence of Sonication Parameters and Injection Rate

Author keywords

Blood brain barrier; Brain; Focused ultrasound; Transcranial therapy

Indexed keywords

BLOOD-BRAIN BARRIER; BURST PULSE; CONTRAST AGENT; DEFINITY; DUTY CYCLES; FOCUSED ULTRASOUND; INJECTION RATES; MICRO-BUBBLE; MICROBUBBLES; NUMBER OF CYCLES; OPTIMAL PARAMETER; PULSE SEQUENCE; SAFETY BENEFITS; SHORT BURSTS; SHORT PULSE; SINGLE-PULSE; SONICATION PARAMETERS; STANDING WAVE; STATISTICAL SIGNIFICANCE; TRANSCRANIAL;

EID: 79952737915     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2011.01.008     Document Type: Article
Times cited : (111)

References (21)
  • 1
    • 67650266248 scopus 로고    scopus 로고
    • Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in mice
    • Bing K.F., Howles G.P., Qi Y., Palmeri M.L., Nightingale K.R. Blood-brain barrier (BBB) disruption using a diagnostic ultrasound scanner and Definity in mice. Ultrasound Med Biol 2009, 35:1298-1308.
    • (2009) Ultrasound Med Biol , vol.35 , pp. 1298-1308
    • Bing, K.F.1    Howles, G.P.2    Qi, Y.3    Palmeri, M.L.4    Nightingale, K.R.5
  • 2
    • 33845675648 scopus 로고    scopus 로고
    • Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice
    • Choi J.J., Pernot M., Small S.A., Konofagou E.E. Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice. Ultrasound Med Biol 2007, 33:95-104.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 95-104
    • Choi, J.J.1    Pernot, M.2    Small, S.A.3    Konofagou, E.E.4
  • 3
    • 71849102712 scopus 로고    scopus 로고
    • Molecules of various pharmacologically-relevant sizes can cross the ultrasound-induced blood-brain barrier opening in vivo
    • Choi J.J., Wang S., Tung Y.-S., Morrison B., Konofagou E.E. Molecules of various pharmacologically-relevant sizes can cross the ultrasound-induced blood-brain barrier opening in vivo. Ultrasound Med Biol 2010, 36:58-67.
    • (2010) Ultrasound Med Biol , vol.36 , pp. 58-67
    • Choi, J.J.1    Wang, S.2    Tung, Y.-S.3    Morrison, B.4    Konofagou, E.E.5
  • 5
    • 79952739274 scopus 로고    scopus 로고
    • Noninvasive and localized blood-brain barrier disruption using focused ultrasound can be achieved at short pulse lengths and low pulse repetition frequencies
    • [epub ahead of print]
    • Choi J.J., Selert K., Gao Z., Samiotaki G., Baseri B., Konofagou E.E. Noninvasive and localized blood-brain barrier disruption using focused ultrasound can be achieved at short pulse lengths and low pulse repetition frequencies. J Cereb Blood Flow Metab 2010, [epub ahead of print].
    • (2010) J Cereb Blood Flow Metab
    • Choi, J.J.1    Selert, K.2    Gao, Z.3    Samiotaki, G.4    Baseri, B.5    Konofagou, E.E.6
  • 6
    • 65449147886 scopus 로고    scopus 로고
    • An MRI-compatible system for focused ultrasound experiments in small animal models
    • Chopra R., Curiel L., Staruch R., Morrison L., Hynynen K. An MRI-compatible system for focused ultrasound experiments in small animal models. Med Phys 2009, 36:1867-1874.
    • (2009) Med Phys , vol.36 , pp. 1867-1874
    • Chopra, R.1    Curiel, L.2    Staruch, R.3    Morrison, L.4    Hynynen, K.5
  • 7
    • 77953303635 scopus 로고    scopus 로고
    • Influence of exposure time and pressure amplitude on blood-brain-barrier opening using transcranial ultrasound exposures
    • Chopra R., Vykhodtseva N., Hynynen K. Influence of exposure time and pressure amplitude on blood-brain-barrier opening using transcranial ultrasound exposures. ACS Chem Neurosci 2010, 1:391-398.
    • (2010) ACS Chem Neurosci , vol.1 , pp. 391-398
    • Chopra, R.1    Vykhodtseva, N.2    Hynynen, K.3
  • 8
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen K., McDannold N., Vykhodtseva N., Jolesz F.A. Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 2001, 220:640-646.
    • (2001) Radiology , vol.220 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 9
    • 0037361542 scopus 로고    scopus 로고
    • The threshold for brain damage in rabbits induced by bursts of ultrasound in the presence of an ultrasound contrast agent (Optison)
    • Hynynen K., McDannold N., Martin H., Jolesz F.A., Vykhodtseva N. The threshold for brain damage in rabbits induced by bursts of ultrasound in the presence of an ultrasound contrast agent (Optison). Ultrasound Med Biol 2003, 29:473-481.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 473-481
    • Hynynen, K.1    McDannold, N.2    Martin, H.3    Jolesz, F.A.4    Vykhodtseva, N.5
  • 10
    • 77956287949 scopus 로고    scopus 로고
    • Antibodies targeted to the brain with image-guided focused ultrasound reduces amyloid-beta plaque load in the TgCRND8 mouse model of Alzheimer's disease
    • Jordão J.F., Ayala-Grosso C.A., Markham K., Huang Y., Chopra R., McLaurin J., Hynynen K., Aubert I. Antibodies targeted to the brain with image-guided focused ultrasound reduces amyloid-beta plaque load in the TgCRND8 mouse model of Alzheimer's disease. PLoS One 2010, 5:e10549.
    • (2010) PLoS One , vol.5
    • Jordão, J.F.1    Ayala-Grosso, C.A.2    Markham, K.3    Huang, Y.4    Chopra, R.5    McLaurin, J.6    Hynynen, K.7    Aubert, I.8
  • 11
    • 33746851261 scopus 로고    scopus 로고
    • Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced blood-brain barrier disruption
    • Kinoshita M., McDannold N., Jolesz F.A., Hynynen K. Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced blood-brain barrier disruption. Proc Natl Acad Sci U S A 2006, 103:11719-11723.
    • (2006) Proc Natl Acad Sci U S A , vol.103 , pp. 11719-11723
    • Kinoshita, M.1    McDannold, N.2    Jolesz, F.A.3    Hynynen, K.4
  • 12
    • 33645513645 scopus 로고    scopus 로고
    • Targeted disruption of the blood-brain barrier with focused ultrasound: Association with cavitation activity
    • McDannold N., Vykhodtseva N., Hynynen K. Targeted disruption of the blood-brain barrier with focused ultrasound: Association with cavitation activity. Phys Med Biol 2006, 51:793-807.
    • (2006) Phys Med Biol , vol.51 , pp. 793-807
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 13
    • 33947524046 scopus 로고    scopus 로고
    • Use of ultrasound pulses combined with Definity for targeted blood-brain barrier disruption: a feasibility study
    • McDannold N., Vykhodtseva N., Hynynen K. Use of ultrasound pulses combined with Definity for targeted blood-brain barrier disruption: a feasibility study. Ultrasound Med Biol 2007, 33:584-590.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 584-590
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 14
    • 42949140276 scopus 로고    scopus 로고
    • Blood-brain barrier disruption induced by focused ultrasound and circulating preformed microbubbles appears to be characterized by the mechanical index
    • McDannold N., Vykhodtseva N., Hynynen K. Blood-brain barrier disruption induced by focused ultrasound and circulating preformed microbubbles appears to be characterized by the mechanical index. Ultrasound Med Biol 2008, 34:834-840.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 834-840
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 15
    • 43849110904 scopus 로고    scopus 로고
    • Effects of acoustic parameters and ultrasound contrast agent dose on focused-ultrasound induced blood-brain barrier disruption
    • McDannold N., Vykhodtseva N., Hynynen K. Effects of acoustic parameters and ultrasound contrast agent dose on focused-ultrasound induced blood-brain barrier disruption. Ultrasound Med Biol 2008, 34:930-937.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 930-937
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 17
    • 78149298723 scopus 로고    scopus 로고
    • Impact of standing wave effects on transcranial focused ultrasound disruption of the blood-brain barrier in a rat model
    • O'Reilly M.A., Huang Y., Hynynen K. Impact of standing wave effects on transcranial focused ultrasound disruption of the blood-brain barrier in a rat model. Phys Med Biol 2010, 55:5251-5267.
    • (2010) Phys Med Biol , vol.55 , pp. 5251-5267
    • O'Reilly, M.A.1    Huang, Y.2    Hynynen, K.3
  • 18
    • 12344273726 scopus 로고    scopus 로고
    • The blood-brain barrier: Bottleneck in brain drug development
    • Pardridge W.M. The blood-brain barrier: Bottleneck in brain drug development. NeuroRx 2005, 2:3-14.
    • (2005) NeuroRx , vol.2 , pp. 3-14
    • Pardridge, W.M.1
  • 19
    • 4143081639 scopus 로고    scopus 로고
    • Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles
    • Sheikov N., McDannold N., Vykhodtseva N., Jolesz F., Hynynen K. Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles. Ultrasound Med Biol 2004, 30:979-989.
    • (2004) Ultrasound Med Biol , vol.30 , pp. 979-989
    • Sheikov, N.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.4    Hynynen, K.5
  • 20
    • 34547121440 scopus 로고    scopus 로고
    • Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound
    • Treat L.H., McDannold N., Vykhodtseva N., Zhang Y., Tam K., Hynynen K. Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound. Int J Cancer 2007, 121:901-907.
    • (2007) Int J Cancer , vol.121 , pp. 901-907
    • Treat, L.H.1    McDannold, N.2    Vykhodtseva, N.3    Zhang, Y.4    Tam, K.5    Hynynen, K.6
  • 21
    • 44249098561 scopus 로고    scopus 로고
    • Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption
    • Yang F.-Y., Fu W.-M., Chen W.-S., Yeh W.-L., Lin W.-L. Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption. Ultrason Sonochem 2008, 15:636-643.
    • (2008) Ultrason Sonochem , vol.15 , pp. 636-643
    • Yang, F.-Y.1    Fu, W.-M.2    Chen, W.-S.3    Yeh, W.-L.4    Lin, W.-L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.