메뉴 건너뛰기




Volumn 15, Issue 2, 2011, Pages

Use of minimally invasive hemodynamic monitoring to assess dynamic changes in cardiac output at the bedside

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURE; HEART INDEX; HEART OUTPUT MEASUREMENT; HEMODYNAMIC MONITORING; LETTER; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; THERMODILUTION; FEMALE; HEART CATHETERIZATION; HEART OUTPUT; HUMAN; MALE; NOTE; PHYSIOLOGY; PULMONARY ARTERY; STANDARD; SWAN GANZ CATHETER;

EID: 79952462406     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/cc10024     Document Type: Letter
Times cited : (2)

References (5)
  • 1
    • 79952457091 scopus 로고    scopus 로고
    • Pulse contour analysis: Is it able to reliably detect changes in cardiac output in the hemodynamically unstable patient?
    • 10.1186/cc9381, 21349140
    • Critchley LAH. Pulse contour analysis: Is it able to reliably detect changes in cardiac output in the hemodynamically unstable patient?. Crit Care 2011, 15:106. 10.1186/cc9381, 21349140.
    • (2011) Crit Care , vol.15 , pp. 106
    • Critchley, L.A.H.1
  • 2
    • 78549248199 scopus 로고    scopus 로고
    • Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters
    • 10.1186/cc9335, 21092290
    • Hadian M, Kim HK, Severyn DA, Pinsky MR. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care 2010, 14:R212. 10.1186/cc9335, 21092290.
    • (2010) Crit Care , vol.14
    • Hadian, M.1    Kim, H.K.2    Severyn, D.A.3    Pinsky, M.R.4
  • 4
    • 34547134966 scopus 로고    scopus 로고
    • An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery
    • 10.1111/j.1365-2044.2007.05135.x, 17635422
    • de Wilde RBP, Schreuder JJ, van den Berg PCM, Jansen JRC. An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery. Anaesthesia 2007, 62:760-768. 10.1111/j.1365-2044.2007.05135.x, 17635422.
    • (2007) Anaesthesia , vol.62 , pp. 760-768
    • de Wilde, R.B.P.1    Schreuder, J.J.2    van den Berg, P.C.M.3    Jansen, J.R.C.4
  • 5
    • 72449201516 scopus 로고    scopus 로고
    • Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices
    • 10.1007/s00134-009-1570-9, 19593546
    • Squara P, Cecconi M, Rhodes A, Singer M, Chiche JD. Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices. Intensive Care Med 2009, 35:1801-1808. 10.1007/s00134-009-1570-9, 19593546.
    • (2009) Intensive Care Med , vol.35 , pp. 1801-1808
    • Squara, P.1    Cecconi, M.2    Rhodes, A.3    Singer, M.4    Chiche, J.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.