Volumn 25, Issue 2, 2011, Pages 303-306

Comparison of Water Manometry to 2 Commercial Electronic Pressure Monitors for Central Venous Pressure Measurement in Horses

Author keywords

Continuous monitoring; Hydration; Pressure transducer

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; CENTRAL VENOUS CATHETERIZATION; CENTRAL VENOUS PRESSURE; COMPARATIVE STUDY; HORSE; INSTRUMENTATION; MANOMETRY; MONITOR; PHYSIOLOGY; PRESSURE TRANSDUCER;

EID: 79952339342     PISSN: 08916640     EISSN: 19391676     Source Type: Journal    
DOI: 10.1111/j.1939-1676.2010.0670.x     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 33750574933 scopus 로고    scopus 로고
    • Changes in central venous pressure and blood lactate concentration in response to acute blood loss in horses
    • Magdesian KG, Fielding CL, Rhodes DM, Ruby RE. Changes in central venous pressure and blood lactate concentration in response to acute blood loss in horses. J Am Vet Med Assoc 2006;229:1458-1462.
    • (2006) J Am Vet Med Assoc , vol.229 , pp. 1458-1462
    • Magdesian, K.1    Fielding, C.2    Rhodes, D.3    Ruby, R.4
  • 2
    • 0017328910 scopus 로고
    • Effects of preanesthetic medication, anesthesia, and position of recumbency on central venous pressure in horses
    • Klein L, Sherman J. Effects of preanesthetic medication, anesthesia, and position of recumbency on central venous pressure in horses. J Am Vet Med Assoc 1977;170:216-219.
    • (1977) J Am Vet Med Assoc , vol.170 , pp. 216-219
    • Klein, L.1    Sherman, J.2
  • 4
    • 77952782951 scopus 로고    scopus 로고
    • Central venous pressure monitoring in clinical practice
    • quiz 56.
    • Scales K. Central venous pressure monitoring in clinical practice. Nurs Stand 2010;24:49-55; quiz 56.
    • (2010) Nurs Stand , vol.24 , pp. 49-55
    • Scales, K.1
  • 5
    • 0016767188 scopus 로고
    • Positive end-expiratory pressure in anaesthetized spontaneously breathing horses
    • Hall LW, Trim CM. Positive end-expiratory pressure in anaesthetized spontaneously breathing horses. Br J Anaesth 1975;47:819-824.
    • (1975) Br J Anaesth , vol.47 , pp. 819-824
    • Hall, L.1    Trim, C.2
  • 6
    • 79952326870 scopus 로고    scopus 로고
    • Repeatability, reproducibility and effect of head position on central venous pressure measurement in standing adult horses. Proceedings of the ACVIM Forum & Canadian VMA Convention, Montreal, Canada, June 3-6, 2009.
    • Norton JL, Boston R, Underwood C, et al. Repeatability, reproducibility and effect of head position on central venous pressure measurement in standing adult horses. Proceedings of the ACVIM Forum & Canadian VMA Convention, Montreal, Canada, June 3-6, 2009.
    • Norton, J.1    Boston, R.2    Underwood, C.3
  • 7
    • 67650273241 scopus 로고    scopus 로고
    • In-use comparison of blood pressure measurements from an automated blood pressure instrument with those from a mercury sphygmomanometer
    • Gupta P, Mittal L, Rizzo RA, et al. In-use comparison of blood pressure measurements from an automated blood pressure instrument with those from a mercury sphygmomanometer. Biomed Instrum Technol 2009;43:158-163.
    • (2009) Biomed Instrum Technol , vol.43 , pp. 158-163
    • Gupta, P.1    Mittal, L.2    Rizzo, R.3
  • 8
    • 0029348103 scopus 로고
    • Principles of development and design of microsystems
    • Wagner B. Principles of development and design of microsystems. Endosc Surg Allied Technol 1995;3:204-209.
    • (1995) Endosc Surg Allied Technol , vol.3 , pp. 204-209
    • Wagner, B.1
  • 9
    • 0025048927 scopus 로고
    • A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement
    • Bland JM, Altman DG. A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement. Comput Biol Med 1990;20:337-340.
    • (1990) Comput Biol Med , vol.20 , pp. 337-340
    • Bland, J.1    Altman, D.2
  • 10
    • 0004195833 scopus 로고    scopus 로고
    • The MEMS Handbook
    • Gad-el-Hak M, ed. Boca Raton, FL: CRC Press.
    • Madou MJ. MEMS fabrication. In: Gad-el-Hak M, ed. The MEMS Handbook. Boca Raton, FL: CRC Press; 2002:16-16.
    • (2002) MEMS fabrication , pp. 16-16
    • Madou, M.1
  • 12
    • 0029887329 scopus 로고    scopus 로고
    • Accuracy and reliability of disposable pressure transducers coupled with modern pressure monitors
    • Gardner RM. Accuracy and reliability of disposable pressure transducers coupled with modern pressure monitors. Crit Care Med 1996;24:879-882.
    • (1996) Crit Care Med , vol.24 , pp. 879-882
    • Gardner, R.1
  • 13
    • 0028874250 scopus 로고
    • Accuracy of disposable blood pressure transducers used in the critical care setting
    • Bailey RH, Bauer JH, Yanos J. Accuracy of disposable blood pressure transducers used in the critical care setting. Crit Care Med 1995;23:187-192.
    • (1995) Crit Care Med , vol.23 , pp. 187-192
    • Bailey, R.1    Bauer, J.2    Yanos, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.