메뉴 건너뛰기




Volumn 27, Issue 2, 2011, Pages 176-184

The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTHROMETRY; ARTICLE; EQUIPMENT DESIGN; FEMALE; HUMAN; INSTRUMENTATION; JOINT CHARACTERISTICS AND FUNCTIONS; MALE; MUSCLE CONTRACTION; OBSERVER VARIATION; PHYSIOLOGY; PREDICTIVE VALUE; REPRODUCIBILITY; SHOULDER;

EID: 79952268052     PISSN: 09593985     EISSN: 15325040     Source Type: Journal    
DOI: 10.3109/09593985.2010.481011     Document Type: Article
Times cited : (92)

References (26)
  • 2
    • 26244455214 scopus 로고    scopus 로고
    • American Physical Therapy Association APTA, 2nd ed. Alexandria, VA, American Physical Therapy Association
    • American Physical Therapy Association (APTA) 2003 Guide to Physical Therapist Practice, 2nd ed. Alexandria, VA, American Physical Therapy Association
    • (2003) Guide to Physical Therapist Practice
  • 3
    • 0036712926 scopus 로고    scopus 로고
    • Measuring shoulder internal rotation range of motion: A comparison of 3 techniques
    • DOI 10.1053/apmr.2002.34815
    • Awan R, Smith J, Boon AJ 2002 Measuring shoulder internal rotation range of motion: A comparison of 3 techniques. Archives of Physical Medicine and Rehabilitation 83:1229-1234 (Pubitemid 34994410)
    • (2002) Archives of Physical Medicine and Rehabilitation , vol.83 , Issue.9 , pp. 1229-1234
    • Awan, R.1    Smith, J.2    Boon, A.J.3
  • 6
    • 79952260274 scopus 로고    scopus 로고
    • Joint motion and function assessment
    • Philadelphia, Lippincott Williams & Wilkins
    • Clarkson HM 2005 Joint Motion and Function Assessment. A Research-Based Practical Guide. Philadelphia, Lippincott Williams & Wilkins
    • (2005) A Research-based Practical Guide
    • Clarkson, H.M.1
  • 7
    • 34548363288 scopus 로고    scopus 로고
    • The hemiplegic arm: Interrater reliability and concurrent validity of passive range of motion measurements
    • DOI 10.1080/09638280601056145, PII 781629615
    • de Jong LD, Nieuwboer A, Aufdemkampe G 2007 The hemiplegic arm: Interrater reliability and concurrent validity of passive range of motion measurements. Disability and Rehabilitation 29:1442-1448 (Pubitemid 47343373)
    • (2007) Disability and Rehabilitation , vol.29 , Issue.18 , pp. 1442-1448
    • De Jong, L.D.1    Nieuwboer, A.2    Aufdemkampe, G.3
  • 9
    • 84988265017 scopus 로고    scopus 로고
    • A standardized protocol for measurement of range of movement of the shoulder using the Plurimeter-V inclinometer and assessment of its intrarater and interrater reliability
    • Green S, Buchbinder R, Forbes A, Bellamy N 1998 A standardized protocol for measurement of range of movement of the shoulder using the Plurimeter-V inclinometer and assessment of its intrarater and interrater reliability. Arthritis Care and Research 11:43-52 (Pubitemid 28070024)
    • (1998) Arthritis Care and Research , vol.11 , Issue.1 , pp. 43-52
    • Green, S.1    Buchbinder, R.2    Forbes, A.3    Bellamy, N.4
  • 10
    • 33646448263 scopus 로고    scopus 로고
    • Interpreting change scores of tests and measures used in physical therapy
    • Haley SM, Fragala-Pinkham MA 2006 Interpreting change scores of tests and measures used in physical therapy. Physical Therapy 86:735-743
    • (2006) Physical Therapy , vol.86 , pp. 735-743
    • Haley, S.M.1    Fragala-Pinkham, M.A.2
  • 13
    • 0032843325 scopus 로고    scopus 로고
    • Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation
    • MacDermid JC, Chesworth BM, Patterson S, Roth JH 1999 Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation. Journal of Hand Therapy 12:187-192 (Pubitemid 29385996)
    • (1999) Journal of Hand Therapy , vol.12 , Issue.3 , pp. 187-192
    • MacDermid, J.C.1    Chesworth, B.M.2    Patterson, S.3    Roth, J.H.4
  • 16
    • 0021927084 scopus 로고
    • Reliability of goniometric measurements in patients with Duchenne muscular dystrophy
    • Pandya S, Florence JM, King WM, Robison JD, Oxman M, Province MA 1985 Reliability of goniometric measurements in patients with Duchenne muscular dystrophy. Physical Therapy 65:1339-1342 (Pubitemid 15235178)
    • (1985) Physical Therapy , vol.65 , Issue.9 , pp. 1339-1342
    • Pandya, S.1    Florence, J.M.2    King, W.M.3
  • 17
    • 34250167564 scopus 로고    scopus 로고
    • Reliability of arthrometric measurement of shoulder lateral rotation movement in healthy subjects
    • DOI 10.1080/09593980701209121, PII 779290076
    • Piotte F, Gravel D, Nadeau S, Moffet H, Bedard C 2007 Reliability of arthrometric measurement of shoulder lateral rotation movement in healthy subjects. Physiotherapy Theory and Practice 23:169-178 (Pubitemid 46897706)
    • (2007) Physiotherapy Theory and Practice , vol.23 , Issue.3 , pp. 169-178
    • Piotte, F.1    Gravel, D.2    Nadeau, S.3    Moffet, H.4    Bedard, C.5
  • 18
    • 79952273003 scopus 로고    scopus 로고
    • Foundations of clinical research
    • 3rd ed. Upper Saddle River, NJ, Pearson Prentice Hall
    • Portney LG, Watkins MP 2009 Foundations of Clinical Research. Applications to Practice, 3rd ed. Upper Saddle River, NJ, Pearson Prentice Hall
    • (2009) Applications to Practice
    • Portney, L.G.1    Watkins, M.P.2
  • 19
    • 0023227223 scopus 로고
    • Goniometric reliability in a clinical setting: Shoulder measurements
    • Riddle DL, Rothstein JM, Lamb RL 1987 Goniometric reliability in a clinical setting. Shoulder measurements. Physical Therapy 67:668-673 (Pubitemid 17075131)
    • (1987) Physical Therapy , vol.67 , Issue.5 , pp. 668-673
    • Riddle, D.L.1    Rothstein, J.M.2    Lamb, R.L.3
  • 20
    • 0031802276 scopus 로고    scopus 로고
    • Goniometric assessment of shoulder range of motion: Comparison of testing in supine and sitting positions
    • DOI 10.1016/S0003-9993(98)90038-7
    • Sabari JS, Maltzev I, Lubarsky D, Liszkay E, Homel P 1998 Goniometric assessment of shoulder range of motion: Comparison of testing in supine and sitting positions. Archives of Physical Medicine and Rehabilitation 79:647-651 (Pubitemid 28265715)
    • (1998) Archives of Physical Medicine and Rehabilitation , vol.79 , Issue.6 , pp. 647-651
    • Sabari, J.S.1    Maltzev, I.2    Lubarsky, D.3    Liszkay, E.4    Homel, P.5
  • 21
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • Shrout PE, Fleiss JL 1979 Intraclass correlations: Uses in assessing rater reliability. Psychological Bulletin 86:420-428
    • (1979) Psychological Bulletin , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 24
    • 43149085254 scopus 로고    scopus 로고
    • Range of shoulder motion in patients with adhesive capsulitis: Intra-tester reproducibility is acceptable for group comparisons
    • Tveita EK, Ekeberg OM, Juel NG, Bautz-Holter E 2008 Range of shoulder motion in patients with adhesive capsulitis: Intra-tester reproducibility is acceptable for group comparisons. BMC Musculoskeletal Disorders 9:49
    • (2008) BMC Musculoskeletal Disorders , vol.9 , pp. 49
    • Tveita, E.K.1    Ekeberg, O.M.2    Juel, N.G.3    Bautz-Holter, E.4
  • 25
    • 33747767174 scopus 로고    scopus 로고
    • Intraobserver reliability of 4 physiological movements of the shoulder in subjects with and without symptoms
    • DOI 10.1016/j.apmr.2006.05.008, PII S0003999306004394
    • Valentine RE, Lewis JS 2006 Intraobserver reliability of 4 physiological movements of the shoulder in subjects with and without symptoms. Archives of Physical Medicine and Rehabilitation 87:1242-1249 (Pubitemid 44277940)
    • (2006) Archives of Physical Medicine and Rehabilitation , vol.87 , Issue.9 , pp. 1242-1249
    • Valentine, R.E.1    Lewis, J.S.2
  • 26
    • 15744385505 scopus 로고    scopus 로고
    • Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM
    • DOI 10.1519/15184.1
    • Weir JP 2005 Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. Journal of Strength and Conditioning Research 19:231-240 (Pubitemid 40417282)
    • (2005) Journal of Strength and Conditioning Research , vol.19 , Issue.1 , pp. 231-240
    • Weir, J.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.