메뉴 건너뛰기




Volumn 12, Issue 3, 1999, Pages 187-192

Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation

Author keywords

[No Author keywords available]

Indexed keywords

ARM INJURY; ARTICLE; CLINICAL ARTICLE; FEMALE; FROZEN SHOULDER; GONIOMETRY; HUMAN; JOINT MOBILITY; MALE; OBSERVER VARIATION; PASSIVE MOVEMENT; RECURRENT SHOULDER DISLOCATION; RELIABILITY; SUPINE POSITION;

EID: 0032843325     PISSN: 08941130     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0894-1130(99)80045-3     Document Type: Article
Times cited : (85)

References (24)
  • 4
    • 0344912778 scopus 로고
    • The range of motion of the extremities in healthy Japanese people: The difference according to age
    • Wantabe HOK, Amano T, Okabe T. The range of motion of the extremities in healthy Japanese people: the difference according to age. Nippon Seikeigeka Gakkai Zasshi. 1979; 53:285-81.
    • (1979) Nippon Seikeigeka Gakkai Zasshi , vol.53 , pp. 285-381
    • Wantabe, H.O.K.1    Amano, T.2    Okabe, T.3
  • 5
    • 0018777891 scopus 로고
    • Normal range of motion in male subjects
    • Boone DC, Azen SP. Normal range of motion in male subjects. J Bone Joint Surg. 1979;61A:756-9.
    • (1979) J Bone Joint Surg. , vol.61 A , pp. 756-759
    • Boone, D.C.1    Azen, S.P.2
  • 7
    • 25044467829 scopus 로고
    • Shoulder range of motion in persons aged 60 and older
    • Downey PA, Fiebert I, Stackpole JB. Shoulder range of motion in persons aged 60 and older. Phys Ther. 1991;71:S75.
    • (1991) Phys Ther , vol.71
    • Downey, P.A.1    Fiebert, I.2    Stackpole, J.B.3
  • 9
    • 0002770366 scopus 로고
    • A system of joint measurements
    • Clark WA. A system of joint measurements. J Orthop Surg. 1920;2.
    • (1920) J Orthop Surg , pp. 2
    • Clark, W.A.1
  • 10
    • 0001736986 scopus 로고
    • A method of measuring and recording joint function
    • Cave EF, Roberts SM. A method of measuring and recording joint function. J Bone Joint Surg. 1936;18:455-66.
    • (1936) J Bone Joint Surg , vol.18 , pp. 455-466
    • Cave, E.F.1    Roberts, S.M.2
  • 13
    • 0005932983 scopus 로고
    • The shoulder
    • Kessler RM, Hertling D (eds). New York: Harper & Row
    • Kessler RM. The shoulder. In: Kessler RM, Hertling D (eds). Management of Common Musculoskeletal Disorders. New York: Harper & Row, 1983:274-310.
    • (1983) Management of Common Musculoskeletal Disorders , pp. 274-310
    • Kessler, R.M.1
  • 14
    • 0002227385 scopus 로고    scopus 로고
    • Physiatric history and examination
    • Braddom RL, Buschbacher RM, Dumritro D, Johnson EW, Matthew D, Sinaki M (eds). Philadelphia, Pa.: WB Saunders
    • McPeak LA. Physiatric history and examination. In: Braddom RL, Buschbacher RM, Dumritro D, Johnson EW, Matthew D, Sinaki M (eds). Physical Medicine and Rehabilitation. Philadelphia, Pa.: WB Saunders, 1998.
    • (1998) Physical Medicine and Rehabilitation
    • McPeak, L.A.1
  • 16
    • 0023227223 scopus 로고
    • Goniometric reliability in a clinical setting: Shoulder measurements
    • Riddle DL, Rothstein JM, Lamb RL. Goniometric reliability in a clinical setting: shoulder measurements. Phys Ther. 1987;67:668.
    • (1987) Phys Ther , vol.67 , pp. 668
    • Riddle, D.L.1    Rothstein, J.M.2    Lamb, R.L.3
  • 18
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86:420-8.
    • (1979) Psychol Bull , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 19
    • 0030814146 scopus 로고    scopus 로고
    • Use of the standard error as a reliability index of interest: An applied example using elbow flexor strength data
    • Stratford PW, Goldsmith CH. Use of the standard error as a reliability index of interest: an applied example using elbow flexor strength data. Phys Ther. 1997;77:745-50.
    • (1997) Phys Ther , vol.77 , pp. 745-750
    • Stratford, P.W.1    Goldsmith, C.H.2
  • 20
    • 0029016223 scopus 로고
    • Current concepts review: Range-of-motion measurements
    • Lea RD, Gerhardt JJ. Current concepts review: range-of-motion measurements. J Bone Joint Surg. 1995;77A:784-98.
    • (1995) J Bone Joint Surg , vol.77 A , pp. 784-798
    • Lea, R.D.1    Gerhardt, J.J.2
  • 21
  • 22
    • 0002666222 scopus 로고
    • The assessment of joint motion
    • Rothstein JM. New York: Churchill Livingstone
    • Miller PJ. The assessment of joint motion. In: Rothstein JM. Measurement in Physical Therapy, New York: Churchill Livingstone, 1985.
    • (1985) Measurement in Physical Therapy
    • Miller, P.J.1
  • 23
    • 0025407082 scopus 로고
    • The reliability of goniometric measurements of active and passive wrist motions
    • Horger MM. The reliability of goniometric measurements of active and passive wrist motions. Am J Occup Ther. 1990; 44:342-8.
    • (1990) Am J Occup Ther , vol.44 , pp. 342-348
    • Horger, M.M.1