메뉴 건너뛰기




Volumn 371, Issue 1-2, 2011, Pages 52-64

NMR imaging of local cumulative permeate flux and local cake growth in submerged microfiltration processes

Author keywords

Cake growth; Cake removal; Colloidal silica; Local cumulative permeate flux; Nuclear magnetic resonance (NMR) imaging; Submerged microfiltration

Indexed keywords

CAKE GROWTH; CAKE REMOVAL; COLLOIDAL SILICA; LOCAL CUMULATIVE PERMEATE FLUX; NUCLEAR MAGNETIC RESONANCE (NMR) IMAGING; SUBMERGED MICROFILTRATION;

EID: 79952242782     PISSN: 03767388     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.memsci.2011.01.018     Document Type: Article
Times cited : (56)

References (46)
  • 2
    • 1542610124 scopus 로고    scopus 로고
    • In situ monitoring techniques for concentration polarization and fouling phenomena in membrane filtration
    • Chen J.C., Li Q., Elimelech M. In situ monitoring techniques for concentration polarization and fouling phenomena in membrane filtration. Advances in Colloid and Interface Science 2004, 107:83-108.
    • (2004) Advances in Colloid and Interface Science , vol.107 , pp. 83-108
    • Chen, J.C.1    Li, Q.2    Elimelech, M.3
  • 3
    • 3242769051 scopus 로고    scopus 로고
    • Non-invasive observation of synthetic membrane processes-a review of methods
    • Chen V., Li H., Fane A.G. Non-invasive observation of synthetic membrane processes-a review of methods. Journal of Membrane Science 2004, 241:23-44.
    • (2004) Journal of Membrane Science , vol.241 , pp. 23-44
    • Chen, V.1    Li, H.2    Fane, A.G.3
  • 4
    • 0025217464 scopus 로고
    • Quantitative flow measurements in bioreactors by nuclear magnetic resonance imaging
    • Hammer B.E., Heath C.A., Mirer S.D., Belfort G. Quantitative flow measurements in bioreactors by nuclear magnetic resonance imaging. Biotechnology 1990, 8:327-330.
    • (1990) Biotechnology , vol.8 , pp. 327-330
    • Hammer, B.E.1    Heath, C.A.2    Mirer, S.D.3    Belfort, G.4
  • 5
    • 0025417270 scopus 로고
    • Magnetic resonance imaging and modelling of flow in hollow-fiber bioreactors
    • Heath C.A., Belfort G., Hammer B.E., Mirer S.D., Pimbley J.M. Magnetic resonance imaging and modelling of flow in hollow-fiber bioreactors. AIChE Journal 1990, 36(4):547-558.
    • (1990) AIChE Journal , vol.36 , Issue.4 , pp. 547-558
    • Heath, C.A.1    Belfort, G.2    Hammer, B.E.3    Mirer, S.D.4    Pimbley, J.M.5
  • 6
    • 0010715882 scopus 로고
    • Investigation of fluid flow patterns in a hollow fibre module using magnetic resonance velocity imaging
    • Pangrle B.J., Walsh E.G., Moore S.C., DiBiasio D. Investigation of fluid flow patterns in a hollow fibre module using magnetic resonance velocity imaging. Biotechnology Techniques 1989, 3:67-72.
    • (1989) Biotechnology Techniques , vol.3 , pp. 67-72
    • Pangrle, B.J.1    Walsh, E.G.2    Moore, S.C.3    DiBiasio, D.4
  • 8
    • 0028881285 scopus 로고
    • Flow distributions in hollow fiber hemodialyzers using magnetic resonance Fourier velocity imaging
    • Zhang J., Parker D.L., Leypoldt J.K. Flow distributions in hollow fiber hemodialyzers using magnetic resonance Fourier velocity imaging. ASAIO Journal 1995, 41(3):M678-M682.
    • (1995) ASAIO Journal , vol.41 , Issue.3
    • Zhang, J.1    Parker, D.L.2    Leypoldt, J.K.3
  • 10
    • 0037099964 scopus 로고    scopus 로고
    • The use of magnetic resonance imaging and to measure the local ultrafiltration rate in hemodialyzers
    • Hardy P.A., Poh C.K., Liao Z., Clark W.R., Gao D. The use of magnetic resonance imaging and to measure the local ultrafiltration rate in hemodialyzers. Journal of Membrane Science 2002, 204:195-205.
    • (2002) Journal of Membrane Science , vol.204 , pp. 195-205
    • Hardy, P.A.1    Poh, C.K.2    Liao, Z.3    Clark, W.R.4    Gao, D.5
  • 11
    • 0027611192 scopus 로고
    • Dean vortices with wall flux in a curved channel membrane system. 6. Two dimensional magnetic resonance imaging of the velocity field in a curved impermeable slit
    • Chung K.Y., Edelstein W.A., Belfort G. Dean vortices with wall flux in a curved channel membrane system. 6. Two dimensional magnetic resonance imaging of the velocity field in a curved impermeable slit. Journal of Membrane Science 1993, 81:151-162.
    • (1993) Journal of Membrane Science , vol.81 , pp. 151-162
    • Chung, K.Y.1    Edelstein, W.A.2    Belfort, G.3
  • 12
    • 0041307098 scopus 로고    scopus 로고
    • Effect of spacer yarns on the dialysate flow distribution of hemodialyzers: a magnetic resonance imaging study
    • Poh C.K., Hardy P.A., Liao Z.J., Huang Z., Clark W.R., Gao D.Y. Effect of spacer yarns on the dialysate flow distribution of hemodialyzers: a magnetic resonance imaging study. ASAIO Journal 2003, 49:440-448.
    • (2003) ASAIO Journal , vol.49 , pp. 440-448
    • Poh, C.K.1    Hardy, P.A.2    Liao, Z.J.3    Huang, Z.4    Clark, W.R.5    Gao, D.Y.6
  • 13
    • 77955665357 scopus 로고    scopus 로고
    • Chemical cleaning of biofouling in reverse osmosis membranes evaluated using magnetic resonance imaging
    • Creber S.A., Vrouwenvelder J.S., van Loosdrecht M.C.M., Johns M.L. Chemical cleaning of biofouling in reverse osmosis membranes evaluated using magnetic resonance imaging. Journal of Membrane Science 2010, 362:202-210.
    • (2010) Journal of Membrane Science , vol.362 , pp. 202-210
    • Creber, S.A.1    Vrouwenvelder, J.S.2    van Loosdrecht, M.C.M.3    Johns, M.L.4
  • 14
    • 0043013286 scopus 로고    scopus 로고
    • Effect of flow baffles on the dialysate flow distribution of hollow-fiber hemodialyzers: a nonintrusive experimental study using MRI
    • Poh C.K., Hardy P.A., Liao Z.J., Huang Z., Clark W.R., Gao D. Effect of flow baffles on the dialysate flow distribution of hollow-fiber hemodialyzers: a nonintrusive experimental study using MRI. Journal of Biomechanical Engineering 2003, 125:481-489.
    • (2003) Journal of Biomechanical Engineering , vol.125 , pp. 481-489
    • Poh, C.K.1    Hardy, P.A.2    Liao, Z.J.3    Huang, Z.4    Clark, W.R.5    Gao, D.6
  • 18
    • 0029055322 scopus 로고
    • Non-invasive observation of flow profiles and polarisation layers in hollow fibre membrane filtration modules using NMR micro-imaging
    • Yao S., Costello M., Fane A.G., Pope J.M. Non-invasive observation of flow profiles and polarisation layers in hollow fibre membrane filtration modules using NMR micro-imaging. Journal of Membrane Science 1995, 99:207-216.
    • (1995) Journal of Membrane Science , vol.99 , pp. 207-216
    • Yao, S.1    Costello, M.2    Fane, A.G.3    Pope, J.M.4
  • 19
    • 3242811780 scopus 로고
    • Chemical shift selective flow imaging: applications in membrane filtration of oil-water emulsions
    • Yao S., Pope J.M., Fane A.G. Chemical shift selective flow imaging: applications in membrane filtration of oil-water emulsions. Bulletin of Magnetic Resonance 1995, 17:220-221.
    • (1995) Bulletin of Magnetic Resonance , vol.17 , pp. 220-221
    • Yao, S.1    Pope, J.M.2    Fane, A.G.3
  • 20
    • 0030941591 scopus 로고    scopus 로고
    • An investigation of the fluidity of concentration polarisation layers in crossflow membrane filtration of an oil-water emulsion using chemical shift selective flow imaging
    • Yao S., Fane A.G., Pope J.M. An investigation of the fluidity of concentration polarisation layers in crossflow membrane filtration of an oil-water emulsion using chemical shift selective flow imaging. Journal of Magnetic Resonance Imaging 1997, 15:235-242.
    • (1997) Journal of Magnetic Resonance Imaging , vol.15 , pp. 235-242
    • Yao, S.1    Fane, A.G.2    Pope, J.M.3
  • 21
    • 0030592198 scopus 로고    scopus 로고
    • Quantitative measurements of the concentration polarisation layer thickness in membrane filtration of oil-water emulsions using NMR micro-imaging
    • Pope J.M., Yao S., Fane A.G. Quantitative measurements of the concentration polarisation layer thickness in membrane filtration of oil-water emulsions using NMR micro-imaging. Journal of Membrane Science 1996, 118:247-257.
    • (1996) Journal of Membrane Science , vol.118 , pp. 247-257
    • Pope, J.M.1    Yao, S.2    Fane, A.G.3
  • 24
    • 0003042181 scopus 로고
    • Investigations of transient phenomena in crossflow microfiltration of colloidal suspensions using NMR micro-imaging
    • Wandelt B., Schmitz P., Houi D. Investigations of transient phenomena in crossflow microfiltration of colloidal suspensions using NMR micro-imaging. Proceedings of the 6th World Filtration Congress 1993, p. 601ff.
    • (1993) Proceedings of the 6th World Filtration Congress
    • Wandelt, B.1    Schmitz, P.2    Houi, D.3
  • 26
    • 0032496914 scopus 로고    scopus 로고
    • An investigation of concentration polarization phenomena in membrane filtration of colloidal silica suspensions by NMR micro-imaging
    • Airey D., Yao S., Wu J., Chen V., Fane A.G., Pope J.M. An investigation of concentration polarization phenomena in membrane filtration of colloidal silica suspensions by NMR micro-imaging. Journal of Membrane Science 1998, 145:145-158.
    • (1998) Journal of Membrane Science , vol.145 , pp. 145-158
    • Airey, D.1    Yao, S.2    Wu, J.3    Chen, V.4    Fane, A.G.5    Pope, J.M.6
  • 27
    • 79952244816 scopus 로고    scopus 로고
    • Koch Membrane Systems (KMS) GmbH, PURON® Hollow Fiber Module-Hollow Fiber Submerged Membrane Module for MBR Applications, Product Data Sheet, Aachen (Germany)
    • Koch Membrane Systems (KMS) GmbH, PURON® Hollow Fiber Module-Hollow Fiber Submerged Membrane Module for MBR Applications, Product Data Sheet, Aachen (Germany), 2008.
    • (2008)
  • 28
    • 49549109870 scopus 로고    scopus 로고
    • Investigating the impact of production conditions on membrane properties for MBR applications
    • Buetehorn S., Koh C.N., Wintgens T., Volmering D., Vossenkaul K., Melin T. Investigating the impact of production conditions on membrane properties for MBR applications. Desalination 2008, 231:191-199.
    • (2008) Desalination , vol.231 , pp. 191-199
    • Buetehorn, S.1    Koh, C.N.2    Wintgens, T.3    Volmering, D.4    Vossenkaul, K.5    Melin, T.6
  • 29
    • 79952242231 scopus 로고    scopus 로고
    • Eka Akzo Nobel, BINDZIL® 9950 Colloidal Silica. Product Data Sheet, Bohus (Sweden)
    • Eka Akzo Nobel, BINDZIL® 9950 Colloidal Silica. Product Data Sheet, Bohus (Sweden), 2005.
    • (2005)
  • 32
    • 79952243239 scopus 로고    scopus 로고
    • Functional NMR and MRI for Analysis of Materials. PhD Thesis, Macromolecular Chemistry (ITMC), RWTH Aachen University, Germany, in preparation.
    • L. Utiu, Functional NMR and MRI for Analysis of Materials. PhD Thesis, Macromolecular Chemistry (ITMC), RWTH Aachen University, Germany, in preparation.
    • Utiu, L.1
  • 33
    • 0026933679 scopus 로고
    • Ultrafilration of bentonite suspensions with hollow fiber membranes
    • Gourgues C., Aimar P., Sanchez V. Ultrafilration of bentonite suspensions with hollow fiber membranes. Journal of Membrane Science 1992, 74:51-69.
    • (1992) Journal of Membrane Science , vol.74 , pp. 51-69
    • Gourgues, C.1    Aimar, P.2    Sanchez, V.3
  • 34
    • 0028133885 scopus 로고
    • Visualisation of cake formation in crossflow microfiltration
    • Wakeman R.J. Visualisation of cake formation in crossflow microfiltration. Trans IChemE 1994, 72(A):530-540.
    • (1994) Trans IChemE , vol.72 , Issue.A , pp. 530-540
    • Wakeman, R.J.1
  • 35
    • 0032542504 scopus 로고    scopus 로고
    • Flux decline in crossflow microfiltration and ultrafiltration: mechanisms and modeling of membrane fouling
    • Song L. Flux decline in crossflow microfiltration and ultrafiltration: mechanisms and modeling of membrane fouling. Journal of Membrane Science 1998, 139:183-200.
    • (1998) Journal of Membrane Science , vol.139 , pp. 183-200
    • Song, L.1
  • 36
    • 0037039539 scopus 로고    scopus 로고
    • A Unifying model for concentration polarization, gel-layer formation and particle deposition in cross-flow membrane filtration of colloidal suspensions
    • Bacchin P., Si-Hassen D., Starov V., Clifton M.J., Aimar P. A Unifying model for concentration polarization, gel-layer formation and particle deposition in cross-flow membrane filtration of colloidal suspensions. Chemical Engineering Science 2002, 57:77-91.
    • (2002) Chemical Engineering Science , vol.57 , pp. 77-91
    • Bacchin, P.1    Si-Hassen, D.2    Starov, V.3    Clifton, M.J.4    Aimar, P.5
  • 37
    • 0031081982 scopus 로고    scopus 로고
    • Effects of aeration on suction pressure in a submerged membrane bioreactor
    • Ueda T., Hata K., Kikuoka Y., Seino O. Effects of aeration on suction pressure in a submerged membrane bioreactor. Water Research 1997, 31(3):489-494.
    • (1997) Water Research , vol.31 , Issue.3 , pp. 489-494
    • Ueda, T.1    Hata, K.2    Kikuoka, Y.3    Seino, O.4
  • 38
    • 79952243087 scopus 로고    scopus 로고
    • Fouling Behavior of Microstructured Hollow Fiber Membranes in Dead-End Filtrations: Critical Flux Determination and NMR Imaging of Particle Deposition, Langmuir (in press).
    • P.Z. Çulfaz, S. Buetehorn, L. Utiu, M. Küppers, B. Blümich, T. Melin, M. Wessling and R.G.H. Lammertink, Fouling Behavior of Microstructured Hollow Fiber Membranes in Dead-End Filtrations: Critical Flux Determination and NMR Imaging of Particle Deposition, Langmuir (in press).
    • Çulfaz, P.Z.1    Buetehorn, S.2    Utiu, L.3    Küppers, M.4    Blümich, B.5    Melin, T.6    Wessling, M.7    Lammertink, R.G.H.8
  • 42
    • 0022347662 scopus 로고
    • Regional physiological functions depicted by sequences of rapid magnetic resonance images
    • Matthaei D., Frahm J., Haase A., Hanicke W. Regional physiological functions depicted by sequences of rapid magnetic resonance images. LANCET 1985, 2(8460):893.
    • (1985) LANCET , vol.2 , Issue.8460 , pp. 893
    • Matthaei, D.1    Frahm, J.2    Haase, A.3    Hanicke, W.4
  • 43
    • 0022592172 scopus 로고
    • Rapid NMR imaging of dynamic processes using the FLASH technique
    • Frahm J., Haase A., Matthaei D. Rapid NMR imaging of dynamic processes using the FLASH technique. Magnetic Resonance Medicine 1986, 3(2):321-327.
    • (1986) Magnetic Resonance Medicine , vol.3 , Issue.2 , pp. 321-327
    • Frahm, J.1    Haase, A.2    Matthaei, D.3
  • 46
    • 0022515243 scopus 로고
    • Dynamic digital subtraction imaging using fast low-angle shot MR movie sequence
    • Haase A., Matthaei D., Hanicke W., Frahm J. Dynamic digital subtraction imaging using fast low-angle shot MR movie sequence. Radiology 1986, 160:537-541.
    • (1986) Radiology , vol.160 , pp. 537-541
    • Haase, A.1    Matthaei, D.2    Hanicke, W.3    Frahm, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.