메뉴 건너뛰기




Volumn 8, Issue 3, 2011, Pages 480-483

Implantable cardioverter-defibrillators in congenital heart disease: 10 programming tips

Author keywords

Congenital heart disease; Implantable cardioverter defibrillator; Shock; Tetralogy of Fallot; Transposition of the great arteries; Ventricular tachycardia

Indexed keywords

ARTICLE; ATRIOVENTRICULAR BLOCK; CONGENITAL HEART DISEASE; DEFIBRILLATOR; HEART PACING; HEART RATE; HEART VENTRICLE TACHYCARDIA; HUMAN; PRIORITY JOURNAL; TACHYCARDIA;

EID: 79952188978     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2010.10.046     Document Type: Article
Times cited : (23)

References (17)
  • 1
    • 38349139544 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillators in tetralogy of Fallot
    • P. Khairy, L. Harris, and M.J. Landzberg Implantable cardioverter- defibrillators in tetralogy of Fallot Circulation 117 2008 363 370
    • (2008) Circulation , vol.117 , pp. 363-370
    • Khairy, P.1    Harris, L.2    Landzberg, M.J.3
  • 3
    • 58849139288 scopus 로고    scopus 로고
    • Sudden death and defibrillators in transposition of the great arteries with intra-atrial baffles: A multicenter study
    • P. Khairy, L. Harris, and M.J. Landzberg Sudden death and defibrillators in transposition of the great arteries with intra-atrial baffles: a multicenter study Circ Arrhythm Electrophysiol 1 2008 250 257
    • (2008) Circ Arrhythm Electrophysiol , vol.1 , pp. 250-257
    • Khairy, P.1    Harris, L.2    Landzberg, M.J.3
  • 4
    • 4644371055 scopus 로고    scopus 로고
    • Differences in tachyarrhythmia detection and implantable cardioverter defibrillator therapy by primary or secondary prevention indication in cardiac resynchronization therapy patients
    • DOI 10.1046/j.1540-8167.2004.03625.x
    • B.L. Wilkoff, M. Hess, J. Young, and W.T. Abraham Differences in tachyarrhythmia detection and implantable cardioverter defibrillator therapy by primary or secondary prevention indication in cardiac resynchronization therapy patients J Cardiovasc Electrophysiol 15 2004 1002 1009 (Pubitemid 39281528)
    • (2004) Journal of Cardiovascular Electrophysiology , vol.15 , Issue.9 , pp. 1002-1009
    • Wilkoff, B.L.1    Hess, M.2    Young, J.3    Abraham, W.T.4
  • 6
    • 7544220287 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing fast ventricular tachycardia reduces shock therapies (PainFREE Rx II) trial results
    • DOI 10.1161/01.CIR.0000145610.64014.E4
    • M.S. Wathen, P.J. DeGroot, and M.O. Sweeney Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results Circulation 110 2004 2591 2596 (Pubitemid 39453007)
    • (2004) Circulation , vol.110 , Issue.17 , pp. 2591-2596
    • Wathen, M.S.1    DeGroot, P.J.2    Sweeney, M.O.3    Stark, A.J.4    Otterness, M.F.5    Adkisson, W.O.6    Canby, R.C.7    Khalighi, K.8    Machado, C.9    Rubenstein, D.S.10    Volosin, K.J.11
  • 7
    • 33745685677 scopus 로고    scopus 로고
    • A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: Results from the prospective randomized multicenter EMPIRIC trial
    • B.L. Wilkoff, K.T. Ousdigian, L.D. Sterns, Z.J. Wang, R.D. Wilson, and J.M. Morgan A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: results from the prospective randomized multicenter EMPIRIC trial J Am Coll Cardiol 48 2006 330 339
    • (2006) J Am Coll Cardiol , vol.48 , pp. 330-339
    • Wilkoff, B.L.1    Ousdigian, K.T.2    Sterns, L.D.3    Wang, Z.J.4    Wilson, R.D.5    Morgan, J.M.6
  • 8
    • 48449088263 scopus 로고    scopus 로고
    • Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: Results from the PREPARE (Primary Prevention Parameters Evaluation) study
    • B.L. Wilkoff, B.D. Williamson, and R.S. Stern Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study J Am Coll Cardiol 52 2008 541 550
    • (2008) J Am Coll Cardiol , vol.52 , pp. 541-550
    • Wilkoff, B.L.1    Williamson, B.D.2    Stern, R.S.3
  • 12
    • 0034321839 scopus 로고    scopus 로고
    • Prevention of ventricular arrhythmias in the congenital long QT syndrome
    • S. Viskin, and R. Fish Prevention of ventricular arrhythmias in the congenital long QT syndrome Curr Cardiol Rep 2 2000 492 497
    • (2000) Curr Cardiol Rep , vol.2 , pp. 492-497
    • Viskin, S.1    Fish, R.2
  • 13
    • 11144262281 scopus 로고    scopus 로고
    • Absent ventricular tachycardia detection in a biventricular implantable cardioverter-defibrillator due to intradevice interaction with a rate smoothing pacing algorithm
    • DOI 10.1016/j.hrthm.2004.08.013, PII S1547527104005168
    • J.M. Cooper, W.H. Sauer, and R.J. Verdino Absent ventricular tachycardia detection in a biventricular implantable cardioverter-defibrillator due to intradevice interaction with a rate smoothing pacing algorithm Heart Rhythm 1 2004 728 731 (Pubitemid 40028781)
    • (2004) Heart Rhythm , vol.1 , Issue.6 , pp. 728-731
    • Cooper, J.M.1    Sauer, W.H.2    Verdino, R.J.3
  • 14
    • 33645969548 scopus 로고    scopus 로고
    • Effects of a rate smoothing algorithm for prevention of ventricular arrhythmias: Results of the Ventricular Arrhythmia Suppression Trial (VAST)
    • P.A. Friedman, S. Jalal, and S. Kaufman Effects of a rate smoothing algorithm for prevention of ventricular arrhythmias: results of the Ventricular Arrhythmia Suppression Trial (VAST) Heart Rhythm 3 2006 573 580
    • (2006) Heart Rhythm , vol.3 , pp. 573-580
    • Friedman, P.A.1    Jalal, S.2    Kaufman, S.3
  • 15
    • 50449098168 scopus 로고    scopus 로고
    • Discriminatory therapy for very fast ventricular tachycardia in patients with implantable cardioverter defibrillators
    • G. Sivagangabalan, S. Eshoo, V.E. Eipper, A. Thiagalingam, and P. Kovoor Discriminatory therapy for very fast ventricular tachycardia in patients with implantable cardioverter defibrillators Pacing Clin Electrophysiol 31 2008 1095 1099
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1095-1099
    • Sivagangabalan, G.1    Eshoo, S.2    Eipper, V.E.3    Thiagalingam, A.4    Kovoor, P.5
  • 17
    • 0031038116 scopus 로고    scopus 로고
    • Antitachycardia pacing in patients with implantable cardioverter defibrillators: How many attempts are useful?
    • DOI 10.1111/j.1540-8159.1997.tb04842.x
    • R. Fries, A. Heisel, G. Kalweit, J. Jung, and H. Schieffer Antitachycardia pacing in patients with implantable cardioverter defibrillators: how many attempts are useful? Pacing Clin Electrophysiol 20 1 Pt 2 1997 198 202 (Pubitemid 27053860)
    • (1997) PACE - Pacing and Clinical Electrophysiology , vol.20 , Issue.1 SUPPL. , pp. 198-202
    • Fries, R.1    Heisel, A.2    Kalweit, G.3    Jung, J.4    Schieffer, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.