메뉴 건너뛰기




Volumn 34, Issue 1, 2011, Pages 59-64

Inter-rater reliability of the Modified Ashworth Scale and modified Modified Ashworth Scale in assessing poststroke elbow flexor spasticity

Author keywords

hemiplegia; inter rater variation; muscle spasticity

Indexed keywords

CLINICAL PRACTICES; ELBOW FLEXOR; HEMIPLEGIA; INTER-RATER VARIATION; KAPPA VALUES; MEAN AGES; SPASTICITY;

EID: 79952187482     PISSN: 03425282     EISSN: None     Source Type: Journal    
DOI: 10.1097/MRR.0b013e32833d6cdf     Document Type: Article
Times cited : (59)

References (23)
  • 1
    • 0029967641 scopus 로고    scopus 로고
    • Reliability of the Modified Ashworth Scale in the assessment of plantarflexor muscle spasticity in patients with traumatic brain injury
    • Allison SC, Abraham LD, Petersen CL (1996). Reliability of the Modified Ashworth Scale in the assessment of plantarflexor muscle spasticity in patients with traumatic brain injury. Int J Rehabil Res 19:67-78. (Pubitemid 26127766)
    • (1996) International Journal of Rehabilitation Research , vol.19 , Issue.1 , pp. 67-78
    • Allison, S.C.1    Abraham, L.D.2    Petersen, C.L.3
  • 2
    • 34247523380 scopus 로고    scopus 로고
    • Measurement of plantarflexor spasticity in traumatic brain injury: Correlational study of resistance torque compared with the modified Ashworth scale
    • DOI 10.1097/PHM.0b013e31804a7d85, PII 0000206020070500000012
    • Annaswamy T, Mallempati S, Allison SC, Abraham LD (2007). Measurement of plantarflexor spasticity in traumatic brain injury: correlational study of resistance torque compared with the modified Ashworth scale. Am J Phys Med Rehabil 86:404-411. (Pubitemid 46652198)
    • (2007) American Journal of Physical Medicine and Rehabilitation , vol.86 , Issue.5 , pp. 404-411
    • Annaswamy, T.1    Mallempati, S.2    Allison, S.C.3    Abraham, L.D.4
  • 3
    • 33745162556 scopus 로고    scopus 로고
    • Ashworth Scales are unreliable for the assessment of muscle spasticity
    • DOI 10.1080/09593980600724188, PII Q517171010133
    • Ansari NN, Naghdi S, Moammeri H, Jalaie S (2006). Ashworth Scales are unreliable for the assessment of muscle spasticity. Physiother Theory Pract 22:119-125. (Pubitemid 43890817)
    • (2006) Physiotherapy Theory and Practice , vol.22 , Issue.3 , pp. 119-125
    • Ansari, N.N.1    Naghdi, S.2    Moammeri, H.3    Jalaie, S.4
  • 4
    • 45749133847 scopus 로고    scopus 로고
    • Inter- and intrarater reliability of the Modified Modified Ashworth Scale in patients with knee extensor poststroke spasticity
    • DOI 10.1080/09593980701523802, PII 793965935
    • Ansari NN, Naghdi S, Younesian P, Shayeghan M (2008). Inter- and intrarater reliability of the Modified Modified Ashworth Scale in patients with knee extensor poststroke spasticity. Physiother Theory Pract 24:205-213. (Pubitemid 351874168)
    • (2008) Physiotherapy Theory and Practice , vol.24 , Issue.3 , pp. 205-213
    • Ansari, N.N.1    Naghdi, S.2    Younesian, P.3    Shayeghan, M.4
  • 5
    • 77649207032 scopus 로고    scopus 로고
    • Assessing the reliability of the modified modified ashworth scale between two physiotherapists in adult patients with hemiplegia
    • Ansari NN, Naghdi S, Hasson S, Fakhari Z, Mashayekhi M, Herasi M (2009a). Assessing the reliability of the Modified Modified Ashworth Scale between two physiotherapists in adult patients with hemiplegia. NeuroRehabilitation 25:235-240.
    • (2009) NeuroRehabilitation , vol.25 , pp. 235-240
    • Ansari, N.N.1    Naghdi, S.2    Hasson, S.3    Fakhari, Z.4    Mashayekhi, M.5    Herasi, M.6
  • 6
    • 67651229448 scopus 로고    scopus 로고
    • Inter-rater reliability of the modified modified ashworth scale as a clinical tool in measurements of post-stroke elbow flexor spasticity
    • Ansari NN, Naghdi S, Hasson S, Mousakhani A, Nouriyan A, Omidvar Z (2009b). Inter-rater reliability of the Modified Modified Ashworth Scale as a clinical tool in measurements of post-stroke elbow flexor spasticity. NeuroRehabilitation 24:225-229.
    • (2009) NeuroRehabilitation , vol.24 , pp. 225-229
    • Ansari, N.N.1    Naghdi, S.2    Hasson, S.3    Mousakhani, A.4    Nouriyan, A.5    Omidvar, Z.6
  • 7
    • 33845588119 scopus 로고    scopus 로고
    • Spasticity-assessment: A review
    • DOI 10.1038/sj.sc.3101928, PII 3101928
    • Biering-Sørensen F, Nielsen JB, Klinge K (2006). Spasticity-assessment: a review. Spinal Cord 44:708-722. (Pubitemid 44934977)
    • (2006) Spinal Cord , vol.44 , Issue.12 , pp. 708-722
    • Biering-Sorensen, F.1    Nielsen, J.B.2    Klinge, K.3
  • 8
    • 0036143993 scopus 로고    scopus 로고
    • Reliability of measurements obtained with the Modified Ashworth Scale in the lower extremities of people with stroke
    • Blackburn M, Van Vliet P, Mockett SP (2002). Reliability of measurements obtained with the Modified Ashworth Scale in the lower extremities of people with stroke. Phys Ther 82:25-34. (Pubitemid 34052113)
    • (2002) Physical Therapy , vol.82 , Issue.1 , pp. 25-34
    • Blackburn, M.1    Van Vliet, P.2    Mockett, S.P.3
  • 9
    • 0023130157 scopus 로고
    • Interrater reliability of a modified Ashworth scale of muscle spasticity
    • Bohannon RW, Smith MB (1987). Interrater reliability of a modified Ashworth scale of muscle spasticity. Phys Ther 67:206-207. (Pubitemid 17026064)
    • (1987) Physical Therapy , vol.67 , Issue.2 , pp. 206-207
    • Bohannon, R.W.1    Smith, M.B.2
  • 10
    • 69149111402 scopus 로고    scopus 로고
    • Reliability and validity of pendulum test measures of spasticity obtained with the Polhemus tracking system from patients with chronic stroke
    • Bohannon RW, Harrison S, Kinsella-Shaw J (2009). Reliability and validity of pendulum test measures of spasticity obtained with the Polhemus tracking system from patients with chronic stroke. J Neuroeng Rehabil 6:30.
    • (2009) J Neuroeng Rehabil , vol.6 , pp. 30
    • Bohannon, R.W.1    Harrison, S.2    Kinsella-Shaw, J.3
  • 11
    • 0026534288 scopus 로고
    • Statistical methods for assessing observer variability in clinical measures
    • Brennan P, Silman A (1992). Statistical methods for assessing observer variability in clinical measures. BMJ 304:1491-1494.
    • (1992) BMJ , vol.304 , pp. 1491-1494
    • Brennan, P.1    Silman, A.2
  • 12
    • 33644984570 scopus 로고    scopus 로고
    • Interrater and intrarater reliability of the Modified Ashworth Scale in children with hypertonia
    • DOI 10.1097/01.pep.0000186509.41238.1a, PII 0000157720050174000007
    • Clopton N, Dutton J, Featherston T, Grigsby A, Mobley J, Melvin J (2005). Interrater and intrarater reliability of the Modified Ashworth Scale in children with hypertonia. Pediatr Phys Ther 17:268-274. (Pubitemid 44406387)
    • (2005) Pediatric Physical Therapy , vol.17 , Issue.4 , pp. 268-274
    • Clopton, N.1    Dutton, J.2    Featherston, T.3    Grigsby, A.4    Mobley, J.5    Melvin, J.6
  • 13
    • 77949321611 scopus 로고    scopus 로고
    • Modified ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI
    • Craven BC, Morris AR (2010). Modified Ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI. Spinal Cord 48:207-13.
    • (2010) Spinal Cord , vol.48 , pp. 207-13
    • Craven, B.C.1    Morris, A.R.2
  • 15
    • 72949118894 scopus 로고    scopus 로고
    • Inter-rater reliability of the modified modified ashworth scale in assessing lower limb muscle spasticity
    • Ghotbi N, Ansari NN, Naghdi S, Hasson S, Jamshidpour B, Amiri S (2009). Inter-rater reliability of the Modified Modified Ashworth Scale in assessing lower limb muscle spasticity. Brain Inj 23:815-819.
    • (2009) Brain Inj , vol.23 , pp. 815-819
    • Ghotbi, N.1    Ansari, N.N.2    Naghdi, S.3    Hasson, S.4    Jamshidpour, B.5    Amiri, S.6
  • 16
  • 17
    • 22844451046 scopus 로고    scopus 로고
    • On the nature and measurement of spasticity
    • DOI 10.1016/j.clinph.2005.03.004, PII S138824570500115X
    • Levin MF (2005). On the nature and measurement of spasticity. Clin Neurophysiol 116:1754-1755. (Pubitemid 41040040)
    • (2005) Clinical Neurophysiology , vol.116 , Issue.8 , pp. 1754-1755
    • Levin, M.F.1
  • 18
    • 42549130450 scopus 로고    scopus 로고
    • Reliability of ashworth and modified ashworth scales in children with spastic cerebral palsy
    • Mutlu A, Livanelioglu A, Gunel MK (2008). Reliability of Ashworth and Modified Ashworth scales in children with spastic cerebral palsy. BMC Musculoskelet Disord 9:44.
    • (2008) BMC Musculoskelet Disord , vol.9 , pp. 44
    • Mutlu, A.1    Livanelioglu, A.2    Gunel, M.K.3
  • 19
    • 52949084326 scopus 로고    scopus 로고
    • Interrater reliability of the modified modified ashworth scale (MMAS) for patients with wrist flexor muscle spasticity
    • Naghdi S, Ansari NN, Azarnia S, Kazemnejad A (2008). Interrater reliability of the Modified Modified Ashworth Scale (MMAS) for patients with wrist flexor muscle spasticity. Physiother Theory Pract 24:372-379.
    • (2008) Physiother Theory Pract , vol.24 , pp. 372-379
    • Naghdi, S.1    Ansari, N.N.2    Azarnia, S.3    Kazemnejad, A.4
  • 20
    • 0032836781 scopus 로고    scopus 로고
    • A review of the properties and limitations of the Ashworth and modified Ashworth Scales as measures of spasticity
    • DOI 10.1191/026921599677595404
    • Pandyan AD, Johnson GR, Price CI, Curless RH, Barnes MP, Rodgers H (1999). A review of the properties and limitations of the Ashworth and modified Ashworth Scales as measures of spasticity. Clin Rehabil 13:373-383. (Pubitemid 29425632)
    • (1999) Clinical Rehabilitation , vol.13 , Issue.5 , pp. 373-383
    • Pandyan, A.D.1    Johnson, G.R.2    Price, C.I.M.3    Curless, R.H.4    Barnes, M.P.5    Rodgers, H.6
  • 21
    • 33646098409 scopus 로고    scopus 로고
    • Test-retest reliability of isokinetic dynamometry for the assessment of spasticity of the knee flexors and knee extensors in children with cerebral palsy
    • Pierce SR, Lauer RT, Shewokis PA, Rubertone JA, Orlin MN (2006). Test-retest reliability of isokinetic dynamometry for the assessment of spasticity of the knee flexors and knee extensors in children with cerebral palsy. Arch Phys Med Rehabil 87:697-702.
    • (2006) Arch Phys Med Rehabil , vol.87 , pp. 697-702
    • Pierce, S.R.1    Lauer, R.T.2    Shewokis, P.A.3    Rubertone, J.A.4    Orlin, M.N.5
  • 22
    • 12344331581 scopus 로고    scopus 로고
    • Clinical scales for the assessment of spasticity, associated phenomena, and function: A systematic review of the literature
    • DOI 10.1080/09638280400014634
    • Platz T, Eickhof C, Nuyens G, Vuadens P (2005). Clinical scales for the assessment of spasticity, associated phenomena, and function: a systematic review of the literature. Disabil Rehabil 27:7-18. (Pubitemid 40124835)
    • (2005) Disability and Rehabilitation , vol.27 , Issue.1-2 , pp. 7-18
    • Platz, T.1    Eickhof, C.2    Nuyens, G.3    Vuadens, P.4
  • 23
    • 0036190345 scopus 로고    scopus 로고
    • Clinical measurement of muscle tone using a velocity-corrected modified Ashworth scale
    • DOI 10.1097/00002060-200203000-00008
    • Smith AW, Jamshidi M, Lo SK (2002). Clinical measurement of muscle tone using a velocity-corrected modified Ashworth scale. Am J Phys Med Rehabil 81:202-206. (Pubitemid 34188761)
    • (2002) American Journal of Physical Medicine and Rehabilitation , vol.81 , Issue.3 , pp. 202-206
    • Smith, A.W.1    Jamshidi, M.2    Lo, S.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.