1
-
-
0033010153
-
Image-guided robotic radiosurgery
-
DOI 10.1097/00006123-199906000-00079
-
J. R. Adler, M. J. Murphy, D. S. Chang, and S. L. Hancock, " Image-guided robotic radiosurgery.," Neurosurgery 0148-396X 44, 1299-1306 (1999). 10.1097/00006123-199906000-00079 (Pubitemid 29252751)
-
(1999)
Neurosurgery
, vol.44
, Issue.6
, pp. 1299-1307
-
-
Adler Jr., J.R.1
Murphy, M.J.2
Chang, S.D.3
Hancock, S.L.4
-
2
-
-
44349155376
-
Reducing monitor units for robotic radiosurgery by optimized use of multiple collimators
-
DOI 10.1118/1.2919090
-
J. J. Pöll, M. S. Hoogeman, J. Pŕvost, J. J. Nuyttens, P. C. Levendag, and B. J. Heijmen, " Reducing monitor units for robotic radiosurgery by optimized use of multiple collimators.," Med. Phys. 0094-2405 35, 2294-2299 (2008). 10.1118/1.2919090 (Pubitemid 351748636)
-
(2008)
Medical Physics
, vol.35
, Issue.6
, pp. 2294-2299
-
-
Poll, J.J.1
Hoogeman, M.S.2
Prevost, J.-B.3
Nuyttens, J.J.4
Levendag, P.C.5
Heijmen, B.J.6
-
3
-
-
0141447423
-
Non-coplanar beam direction optimization for intensity-modulated radiotherapy
-
DOI 10.1088/0031-9155/48/18/304, PII S0031915503590315
-
G. Meedt, M. Alber, and F. Nüsslin, " Non-coplanar beam direction optimization for intensity-modulated radiotherapy.," Phys. Med. Biol. 0031-9155 48, 2999-3019 (2003). 10.1088/0031-9155/48/18/304 (Pubitemid 37192917)
-
(2003)
Physics in Medicine and Biology
, vol.48
, Issue.18
, pp. 2999-3019
-
-
Meedt, G.1
Alber, M.2
Nusslin, F.3
-
4
-
-
0036852437
-
On the degeneracy of the IMRT optimization problem
-
DOI 10.1118/1.1500402
-
M. Alber, G. Meedt, F. Nüsslin, and R. Reemtsen, " On the degeneracy of the IMRT optimization problem.," Med. Phys. 0094-2405 29, 2584-2589 (2002). 10.1118/1.1500402 (Pubitemid 35375457)
-
(2002)
Medical Physics
, vol.29
, Issue.11
, pp. 2584-2589
-
-
Alber, M.1
Meedt, G.2
Nusslin, F.3
Reemtsen, R.4
-
5
-
-
79952136998
-
A Variable circular collimator: A time-efficient alternative for a multi-leaf collimator in robotic radiosurgery?
-
0360-3016, 10.1016/j.ijrob2009.07.1540
-
B. Heijmen, S. van de Water, S. Breedveld, J. Nuyttens, and M. Hoogeman, " A Variable circular collimator: A time-efficient alternative for a multi-leaf collimator in robotic radiosurgery?," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 75, S674-S675 (2009). 10.1016/j.ijrobp.2009.07.1540
-
(2009)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.75
-
-
Heijmen, B.1
Van De Water, S.2
Breedveld, S.3
Nuyttens, J.4
Hoogeman, M.5
-
6
-
-
0033868457
-
Constrained treatment planning using sequential beam selection
-
DOI 10.1088/0031-9155/45/8/306, PII S003191550010034X
-
E. Woudstra and P. R. Storchi, " Constrained treatment planning using sequential beam selection.," Phys. Med. Biol. 0031-9155 45, 2133-2149 (2000). 10.1088/0031-9155/45/8/306 (Pubitemid 30622544)
-
(2000)
Physics in Medicine and Biology
, vol.45
, Issue.8
, pp. 2133-2149
-
-
Woudstra, E.1
Storchi, P.R.M.2
-
7
-
-
28944432097
-
Automated selection of beam orientations and segmented intensity-modulated radiotherapy (IMRT) for treatment of oesophagus tumors
-
DOI 10.1016/j.radonc.2005.06.028, PII S0167814005002720
-
E. Woudstra, B. J. M. Heijmen, and P. R. M. Storchi, " Automated selection of beam orientations and segmented intensity-modulated radiotherapy (IMRT) for treatment of oesophagus tumors.," Radiother. Oncol. 0167-8140 77, 254-261 (2005). 10.1016/j.radonc.2005.06.028 (Pubitemid 41785333)
-
(2005)
Radiotherapy and Oncology
, vol.77
, Issue.3
, pp. 254-261
-
-
Woudstra, E.1
Heijmen, B.J.M.2
Storchi, P.R.M.3
-
8
-
-
52049109637
-
Automated non-coplanar beam direction optimization improves IMRT in SBRT of liver metastasis
-
0167-8140, 10.1016/j.radonc.2008.06.001
-
J. A. de Pooter, A. Ḿndez Romero, W. Wunderink, P. R. M. Storchi, and B. J. M. Heijmen, " Automated non-coplanar beam direction optimization improves IMRT in SBRT of liver metastasis.," Radiother. Oncol. 0167-8140 88, 376-381 (2008). 10.1016/j.radonc.2008.06.001
-
(2008)
Radiother. Oncol.
, vol.88
, pp. 376-381
-
-
De Pooter, J.A.1
Ḿndez Romero, A.2
Wunderink, W.3
Storchi, P.R.M.4
Heijmen, B.J.M.5
-
9
-
-
40949091902
-
SM CyberKnife Treatment for Localized Prostatic Carcinoma: Dosimetry Comparison With HDR Brachytherapy and Preliminary Clinical Observations
-
DOI 10.1016/j.ijrobp.2007.11.067, PII S0360301607047566
-
D. B. Fuller, J. Naitoh, C. Lee, S. Hardy, and H. Jin, " Virtual HDR CyberKnife treatment for localized prostatic carcinoma: Dosimetry comparison with HDR brachytherapy and preliminary clinical observations.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 70, 1588-1597 (2008). 10.1016/j.ijrobp.2007.11.067 (Pubitemid 351417778)
-
(2008)
International Journal of Radiation Oncology Biology Physics
, vol.70
, Issue.5
, pp. 1588-1597
-
-
Fuller, D.B.1
Naitoh, J.2
Lee, C.3
Hardy, S.4
Jin, H.5
-
10
-
-
70350660838
-
The design, physical properties and clinical utility of an iris collimator for robotic radiosurgery
-
0031-9155, 10.1088/0031-9155/54/18/001
-
G. G. Echner, W. Kilby, M. Lee, E. Earnst, S. Sayeh, A. Schlaefer, B. Rhein, J. R. Dooley, C. Lang, O. Blanck, E. Lessard, C. R. Maurer, and W. Schlegel, " The design, physical properties and clinical utility of an iris collimator for robotic radiosurgery.," Phys. Med. Biol. 0031-9155 54, 5359-5380 (2009). 10.1088/0031-9155/54/18/001
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 5359-5380
-
-
Echner, G.G.1
Kilby, W.2
Lee, M.3
Earnst, E.4
Sayeh, S.5
Schlaefer, A.6
Rhein, B.7
Dooley, J.R.8
Lang, C.9
Blanck, O.10
Lessard, E.11
Maurer, C.R.12
Schlegel, W.13
-
11
-
-
77449086474
-
The equivalence of multi-criteria methods for radiotherapy plan optimization
-
0031-9155, 10.1088/0031-9155/54/23/011
-
S. Breedveld, P. R. M. Storchi, and B. J. M. Heijmen, " The equivalence of multi-criteria methods for radiotherapy plan optimization.," Phys. Med. Biol. 0031-9155 54, 7199-7209 (2009). 10.1088/0031-9155/54/23/011
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 7199-7209
-
-
Breedveld, S.1
Storchi, P.R.M.2
Heijmen, B.J.M.3
-
12
-
-
36048950335
-
A novel approach to multi-criteria inverse planning for IMRT
-
DOI 10.1088/0031-9155/52/20/016, PII S0031915507541758
-
S. Breedveld, P. R. M. Storchi, M. Keijzer, A. W. Heemink, and B. J. M. Heijmen, " A novel approach to multi-criteria inverse planning for IMRT.," Phys. Med. Biol. 0031-9155 52, 6339-6353 (2007). 10.1088/0031-9155/52/20/016 (Pubitemid 350093197)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.20
, pp. 6339-6353
-
-
Breedveld, S.1
Storchi, P.R.M.2
Keijzer, M.3
Heemink, A.W.4
Heijmen, B.J.M.5
-
13
-
-
33750559159
-
Resampling: An optimization method for inverse planning in robotic radiosurgery
-
DOI 10.1118/1.2357020
-
A. Schweikard, A. Schlaefer, and J. R. Adler, " Resampling: An optimization method for inverse planning in robotic radiosurgery.," Med. Phys. 0094-2405 33, 4005-4011 (2006). 10.1118/1.2357020 (Pubitemid 44673092)
-
(2006)
Medical Physics
, vol.33
, Issue.11
, pp. 4005-4011
-
-
Schweikard, A.1
Schlaefer, A.2
Adler Jr., J.R.3
-
14
-
-
64049103804
-
Clinical accuracy of the respiratory tumor tracking system of the CyberKnife: Assessment by analysis of log files
-
0360-3016, 10.1016/j.ijrob2008.12.041
-
M. Hoogeman, J. Pŕvost, J. Nuyttens, J. Pöll, P. Levendag, and B. Heijmen, " Clinical accuracy of the respiratory tumor tracking system of the CyberKnife: Assessment by analysis of log files.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 74, 297-303 (2009). 10.1016/j.ijrobp. 2008.12.041
-
(2009)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.74
, pp. 297-303
-
-
Hoogeman, M.1
Pŕvost, J.2
Nuyttens, J.3
Pöll, J.4
Levendag, P.5
Heijmen, B.6
-
15
-
-
33846631295
-
Intra-fraction dose delivery timing during stereotactic radiotherapy can influence the radiobiological effect
-
DOI 10.1118/1.2409750
-
M. J. Murphy, P. Lin, and C. Ozhasoglu, " Intra-fraction dose delivery timing during stereotactic radiotherapy can influence the radiobiological effect.," Med. Phys. 0094-2405 34, 481-484 (2007). 10.1118/1.2409750 (Pubitemid 46185126)
-
(2007)
Medical Physics
, vol.34
, Issue.2
, pp. 481-484
-
-
Murphy, M.J.1
Lin, P.-S.2
Ozhasoglu, C.3
-
16
-
-
25844432193
-
Changes in tumor cell response due to prolonged dose delivery times in fractionated radiation therapy
-
DOI 10.1016/j.ijrobp.2005.07.953, PII S0360301605017335
-
H. Paganetti, " Changes in tumor cell response due to prolonged dose delivery times in fractionated radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 63, 892-900 (2005). 10.1016/j.ijrobp.2005.07.953 (Pubitemid 41400081)
-
(2005)
International Journal of Radiation Oncology Biology Physics
, vol.63
, Issue.3
, pp. 892-900
-
-
Paganetti, H.1
-
17
-
-
79952121820
-
SU-GG-T-544: Delivery time minimization for robotic radiosurgery and IMRT treatments
-
0094-2405, 10.1118/1.3468942
-
J. R. Dooley, C. Sims, G. L. Orr, W. Kilby, E. Lessard, and C. R. Maurer, Jr., " SU-GG-T-544: Delivery time minimization for robotic radiosurgery and IMRT treatments.," Med. Phys. 0094-2405 37, 3312 (2010). 10.1118/1.3468942
-
(2010)
Med. Phys.
, vol.37
, pp. 3312
-
-
Dooley, J.R.1
Sims, C.2
Orr, G.L.3
Kilby, W.4
Lessard, E.5
Maurer, Jr.C.R.6
-
18
-
-
42949096847
-
Stepwise multi-criteria optimization for robotic radiosurgery
-
DOI 10.1118/1.2900716
-
A. Schlaefer and A. Schweikard, " Stepwise multi-criteria optimization for robotic radiosurgery.," Med. Phys. 0094-2405 35, 2094-2103 (2008). 10.1118/1.2900716 (Pubitemid 351614824)
-
(2008)
Medical Physics
, vol.35
, Issue.5
, pp. 2094-2103
-
-
Schlaefer, A.1
Schweikard, A.2
-
19
-
-
63649128442
-
Non-coplanar automatic beam orientation selection in cranial IMRT: A practical methodology
-
0031-9155, 10.1088/0031-9155/54/5/016
-
J. Llacer, S. Li, N. Agazaryan, C. Promberger, and T. D. Solberg, " Non-coplanar automatic beam orientation selection in cranial IMRT: A practical methodology.," Phys. Med. Biol. 0031-9155 54, 1337-1368 (2009). 10.1088/0031-9155/54/5/016
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 1337-1368
-
-
Llacer, J.1
Li, S.2
Agazaryan, N.3
Promberger, C.4
Solberg, T.D.5
-
20
-
-
0346037186
-
Beam orientation selection for intensity-modulated radiation therapy based on target equivalent uniform dose maximization
-
DOI 10.1016/S0360-3016(02)03817-8, PII S0360301602038178
-
S. Das, T. Cullip, G. Tracton, S. Chang, L. Marks, M. Anscher, and J. Rosenman, " Beam orientation selection for intensity-modulated radiation therapy based on target equivalent uniform dose maximization.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 55, 215-224 (2003). 10.1016/S0360- 3016(02)03817-8 (Pubitemid 36020362)
-
(2003)
International Journal of Radiation Oncology Biology Physics
, vol.55
, Issue.1
, pp. 215-224
-
-
Das, S.1
Cullip, T.2
Tracton, G.3
Chang, S.4
Marks, L.5
Anscher, M.6
Rosenman, J.7
-
21
-
-
0035336765
-
Beam-orientation optimization of intensity-modulated radiotherapy: Clinical application to parotid gland tumours
-
DOI 10.1016/S0167-8140(00)00321-2, PII S0167814000003212
-
C. G. Rowbottom, C. M. Nutting, and S. Webb, " Beam-orientation optimization of intensity-modulated radiotherapy: Clinical application to parotid gland tumours.," Radiother. Oncol. 0167-8140 59, 169-177 (2001). 10.1016/S0167-8140(00)00321-2 (Pubitemid 32452310)
-
(2001)
Radiotherapy and Oncology
, vol.59
, Issue.2
, pp. 169-177
-
-
Rowbottom, C.G.1
Nutting, C.M.2
Webb, S.3
-
22
-
-
79952141537
-
Multi-criteria beam angle IMRT optimization
-
0167-8140
-
S. Breedveld, P. Storchi, and B. Heijmen, " Multi-criteria beam angle IMRT optimization.," Radiother. Oncol. 0167-8140 92, S204 (2009).
-
(2009)
Radiother. Oncol.
, vol.92
, pp. 204
-
-
Breedveld, S.1
Storchi, P.2
Heijmen, B.3
|