Volumn 14, Issue 1, 2006, Pages 11-19

A method based on interpolation for metal artifacts reduction in CT images

Author keywords

Interpolation method; Metal artifacts reduction (MAR); X ray CT

Indexed keywords

COMPUTATION THEORY; COMPUTER SIMULATION; IMAGE RECONSTRUCTION; INTERPOLATION; NONDESTRUCTIVE EXAMINATION; X RAYS;

EID: 33645499831     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (20)

References (10)
  • 1
    • 33645508200 scopus 로고    scopus 로고
    • Reasons and correction of the artifacts of single circular orbit cone beam CT
    • Beijing
    • J. GU and L. ZHANG, Reasons and correction of the artifacts of single circular orbit cone beam CT, (Vol. 10), Proceeding of CT& 3D Imaging Conf. 2004, Beijing, 2004, 12-16.
    • (2004) Proceeding of CT& 3D Imaging Conf. 2004 , vol.10 , pp. 12-16
    • Gu, J.1    Zhang, L.2
  • 2
    • 0017955879 scopus 로고
    • Image reconstruction from projections (III): Projection completion methods
    • R.M. Lewitt and R.H. Bates, Image reconstruction from projections (III): Projection completion methods, (Vol. 50), Optik, 1978, 189-204.
    • (1978) Optik , vol.50 , pp. 189-204
    • Lewitt, R.M.1    Bates, R.H.2
  • 3
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • W.A. Kalender, R. Hebel and J. Ebersberger, Reduction of CT artifacts caused by metallic implants, Radiology 164(2) (1987), 576-577.
    • (1987) Radiology , vol.164 , Issue.2 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 4
    • 0034351113 scopus 로고    scopus 로고
    • X-ray CT metal artifacts reduction using wavelets: An application for imaging total hip prostheses
    • S. Zhao, D.D. Robertson, G. Wang, B. Whiting and K.T. Bae, X-ray CT metal artifacts reduction using wavelets: an application for imaging total hip prostheses, IEEE Trans. Med. Imag. 19(12) (2000), 1238-1247.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , Issue.12 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3    Whiting, B.4    Bae, K.T.5
  • 5
    • 33645504312 scopus 로고    scopus 로고
    • Reduction of metal artifact in X-ray CT by quartic-polynomial interpolation
    • Z. LIN and Q. SHI, Reduction of metal artifact in X-ray CT by quartic-polynomial interpolation, Journal of Image and Graphics 6(A)(2) (2001), 142-147.
    • (2001) Journal of Image and Graphics , vol.6 , Issue.2 A , pp. 142-147
    • Lin, Z.1    Shi, Q.2
  • 6
    • 0020845935 scopus 로고
    • Iterative convolution backprojection algorithms for image reconstruction from limited data
    • M.B Petal, Iterative convolution backprojection algorithms for image reconstruction from limited data, Journal of Optical. Society of America 73(11) (1983), 1493-1500.
    • (1983) Journal of Optical. Society of America , vol.73 , Issue.11 , pp. 1493-1500
    • Petal, M.B.1
  • 7
    • 0030270864 scopus 로고    scopus 로고
    • Iterative deblurring for CT metal artifact reduction
    • G. Wang et al., Iterative deblurring for CT metal artifact reduction, IEEE Trans. Med. Imag. 15(5) (1996), 657-664.
    • (1996) IEEE Trans. Med. Imag. , vol.15 , Issue.5 , pp. 657-664
    • Wang, G.1
  • 8
    • 14344266358 scopus 로고    scopus 로고
    • A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy
    • D. Xia, J.C. Roeske, L. Yu, C.A. Pelizzari, A.J. Mundt and X. Pan, A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy, Brachytherapy 4(1) (2005), 18-23.
    • (2005) Brachytherapy , vol.4 , Issue.1 , pp. 18-23
    • Xia, D.1    Roeske, J.C.2    Yu, L.3    Pelizzari, C.A.4    Mundt, A.J.5    Pan, X.6
  • 9
    • 0036030338 scopus 로고    scopus 로고
    • A novel method for reducing high attenuation object artifacts in CT reconstructions
    • L. Chen, Y. Liang, G.A. Sandison and J. Rydberg, A novel method for reducing high attenuation object artifacts in CT reconstructions, Proceedings of SPIE 4684 (2002), 841-850.
    • (2002) Proceedings of SPIE , vol.4684 , pp. 841-850
    • Chen, L.1    Liang, Y.2    Sandison, G.A.3    Rydberg, J.4
  • 10
    • 0022494023 scopus 로고
    • Reprojection using a parallel backprojector
    • C.R. Crawford, Reprojection using a parallel backprojector, Med. Phys. 13 (1986), 480-483.
    • (1986) Med. Phys. , vol.13 , pp. 480-483
    • Crawford, C.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.