메뉴 건너뛰기




Volumn 19, Issue 5, 2011, Pages 4357-4368

Blood cell assisted in vivo Particle Image Velocimetry using the confocal laser scanning microscope

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; CELLS; CONFOCAL MICROSCOPY; FLOW VISUALIZATION; HEMODYNAMICS; OPTICAL MICROSCOPY; VELOCIMETERS; VELOCITY MEASUREMENT;

EID: 79952126800     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.19.004357     Document Type: Article
Times cited : (14)

References (30)
  • 1
    • 0642311549 scopus 로고    scopus 로고
    • Blood flow in arteries
    • D. N. Ku, "Blood flow in arteries," Annu. Rev. Fluid Mech. 29(1), 399-434 (1997).
    • (1997) Annu. Rev. Fluid Mech. , vol.29 , Issue.1 , pp. 399-434
    • Ku, D.N.1
  • 2
    • 0014447480 scopus 로고
    • Blood rheology in pathogenesis of the coronary heart diseases
    • L. Dintenfass, "Blood rheology in pathogenesis of the coronary heart diseases," Am. Heart J. 77(1), 139-147 (1969).
    • (1969) Am. Heart J. , vol.77 , Issue.1 , pp. 139-147
    • Dintenfass, L.1
  • 3
    • 0030973450 scopus 로고    scopus 로고
    • Whole blood viscosity, blood pressure and cardiovascular risk factors in healthy blood donors
    • E. Fossum, A. Høieggen, A. Moan, G. Nordby, T. L. Velund, and S. E. Kjeldsen, "Whole blood viscosity, blood pressure and cardiovascular risk factors in healthy blood donors," Blood Press. 6(3), 161-165 (1997). (Pubitemid 27245204)
    • (1997) Blood Pressure , vol.6 , Issue.3 , pp. 161-165
    • Fossum, E.1    Hoieggen, A.2    Moan, A.3    Nordby, G.4    Velund, T.L.5    Kjeldsen, S.E.6
  • 4
    • 0032554687 scopus 로고    scopus 로고
    • Blood viscosity and elevated carotid intima-media thickness in men and women: The Edinburgh Artery Study
    • A. J. Lee, P. I. Mowbray, G. D. Lowe, A. Rumley, F. G. Fowkes, and P. L. Allan, "Blood viscosity and elevated carotid intima-media thickness in men and women: the Edinburgh Artery Study," Circulation 97(15), 1467-1473 (1998). (Pubitemid 28191302)
    • (1998) Circulation , vol.97 , Issue.15 , pp. 1467-1473
    • Lee, A.J.1    Mowbray, P.I.2    Lowe, G.D.O.3    Rumley, A.4    Fowkes, F.G.R.5    Allan, P.L.6
  • 6
    • 0026674874 scopus 로고
    • Fibrinogen and viscosity as risk factors for subsequent cardiovascular events in stroke survivors
    • K. L. Resch, E. Ernst, A. Matrai, and H. F. Paulsen, "Fibrinogen and viscosity as risk factors for subsequent cardiovascular events in stroke survivors," Ann. Intern. Med. 117(5), 371-375 (1992).
    • (1992) Ann. Intern. Med. , vol.117 , Issue.5 , pp. 371-375
    • Resch, K.L.1    Ernst, E.2    Matrai, A.3    Paulsen, H.F.4
  • 7
    • 0019603363 scopus 로고
    • Regional blood flow measurement with pulsed Doppler flowmeter in conscious rat
    • J. R. Haywood, R. A. Shaffer, C. Fastenow, G. D. Fink, and M. J. Brody, "Regional blood flow measurement with pulsed Doppler flowmeter in conscious rat," Am. J. Physiol. 241(2), H273-H278 (1981).
    • (1981) Am. J. Physiol. , vol.241 , Issue.2
    • Haywood, J.R.1    Shaffer, R.A.2    Fastenow, C.3    Fink, G.D.4    Brody, M.J.5
  • 8
    • 0014054459 scopus 로고
    • Erythrocyte velocity measurement in microvessels by a two-slit photometric method
    • H. Wayland, and P. C. Johnson, "Erythrocyte velocity measurement in microvessels by a two-slit photometric method," J. Appl. Physiol. 22(2), 333-337 (1967).
    • (1967) J. Appl. Physiol. , vol.22 , Issue.2 , pp. 333-337
    • Wayland, H.1    Johnson, P.C.2
  • 10
    • 0030464745 scopus 로고    scopus 로고
    • Fiber-optic laser-Doppler anemometer microscope applied to the cerebral microcirculation in rats
    • DOI 10.1016/S0006-355X(97)00034-6, PII S0006355X97000346
    • J. Seki, Y. Sasaki, T. Oyama, and J. Yamamoto, "Fiber-optic laser-Doppler anemometer microscope applied to the cerebral microcirculation in rats," Biorheology 33(6), 463-470 (1996). (Pubitemid 27087306)
    • (1996) Biorheology , vol.33 , Issue.6 , pp. 463-470
    • Seki, J.1    Sasaki, Y.2    Oyama, T.3    Yamamoto, J.4
  • 11
    • 0000204268 scopus 로고    scopus 로고
    • Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
    • Y. Zhao, Z. Chen, C. Saxer, S. Xiang, J. F. de Boer, and J. S. Nelson, "Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity," Opt. Lett. 25(2), 114-116 (2000).
    • (2000) Opt. Lett. , vol.25 , Issue.2 , pp. 114-116
    • Zhao, Y.1    Chen, Z.2    Saxer, C.3    Xiang, S.4    De Boer, J.F.5    Nelson, J.S.6
  • 13
    • 37349041322 scopus 로고    scopus 로고
    • Optical sectioning for microfluidics: Secondary flow and mixing in a meandering microchannel
    • DOI 10.1039/b713626a
    • Y. C. Ahn, W. G. Jung, and Z. Chen, "Optical sectioning for microfluidics: secondary flow and mixing in a meandering microchannel," Lab Chip 8(1), 125-133 (2007). (Pubitemid 350294130)
    • (2007) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.8 , Issue.1 , pp. 125-133
    • Ahn, Y.-C.1    Jung, W.2    Chen, Z.3
  • 14
    • 12044260218 scopus 로고
    • Particle-imaging techniques for experimental fluid mechanics
    • R. J. Adrian, "Particle-imaging techniques for experimental fluid mechanics," Annu. Rev. Fluid Mech. 23(1), 261-304 (1991).
    • (1991) Annu. Rev. Fluid Mech. , vol.23 , Issue.1 , pp. 261-304
    • Adrian, R.J.1
  • 15
    • 54049135311 scopus 로고    scopus 로고
    • In vivo blood flow and wall shear stress measurements in the vitelline network
    • C. Poelma, P. Vennemann, R. Lindken, and J. Westerweel, "In vivo blood flow and wall shear stress measurements in the vitelline network," Exp. Fluids 45(4), 703-713 (2008).
    • (2008) Exp. Fluids , vol.45 , Issue.4 , pp. 703-713
    • Poelma, C.1    Vennemann, P.2    Lindken, R.3    Westerweel, J.4
  • 17
    • 0033207776 scopus 로고    scopus 로고
    • PIV measurements of a microchannel flow
    • DOI 10.1007/s003480050366
    • C. D. Meinhart, S. T. Wereley, and J. G. Santiago, "PIV measurements of a microchannel flow," Exp. Fluids 27(5), 414-419 (1999). (Pubitemid 30517081)
    • (1999) Experiments in Fluids , vol.27 , Issue.5 , pp. 414-419
    • Meinhart, C.D.1    Wereley, S.T.2    Santiago, J.G.3
  • 18
    • 24144500773 scopus 로고    scopus 로고
    • Micro-PIV simulation and measurement in complex microchannel geometries
    • DOI 10.1088/0957-0233/16/3/002
    • M. R. Bown, J. M. MacInnes, and R. W. K. Allen, "Micro-PIV simulation and measurement in complex microchannel geometries," Meas. Sci. Technol. 16(3), 619-626 (2005). (Pubitemid 41236839)
    • (2005) Measurement Science and Technology , vol.16 , Issue.3 , pp. 619-626
    • Bown, M.R.1    MacInnes, J.M.2    Allen, R.W.K.3
  • 19
    • 33750904556 scopus 로고    scopus 로고
    • Velocity measurement of blood flow in a microtube using micro PIV system
    • Chamonix. France. Jun.
    • R. Okuda, Y. Sugii, and K. Okamoto, "Velocity measurement of blood flow in a microtube using micro PIV system," in Proceedings of PSFVIP-4, (Chamonix. France. Jun. 2003), pp. 1-7.
    • (2003) Proceedings of PSFVIP-4 , pp. 1-7
    • Okuda, R.1    Sugii, Y.2    Okamoto, K.3
  • 20
    • 0036000323 scopus 로고    scopus 로고
    • In vivo PIV measurement of red blood cell velocity field in microvessels considering mesentery motion
    • DOI 10.1088/0967-3334/23/2/315, PII S0967333402326005
    • Y. Sugii, S. Nishio, and K. Okamoto, "In vivo PIV measurement of red blood cell velocity field in microvessels considering mesentery motion," Physiol. Meas. 23(2), 403-416 (2002). (Pubitemid 34546023)
    • (2002) Physiological Measurement , vol.23 , Issue.2 , pp. 403-416
    • Sugii, Y.1    Nishio, S.2    Okamoto, K.3
  • 21
    • 1642521675 scopus 로고    scopus 로고
    • Measurement of red cell velocity in microvessels using particle image velocimetry (PIV)
    • A. Nakano, Y. Sugii, M. Minamiyama, and H. Niimi, "Measurement of red cell velocity in microvessels using particle image velocimetry (PIV)," Clin. Hemorheol. Microcirc. 29(3-4), 445-455 (2003). (Pubitemid 38130419)
    • (2003) Clinical Hemorheology and Microcirculation , vol.29 , Issue.3-4 , pp. 445-455
    • Nakano, A.1    Sugii, Y.2    Minamiyama, M.3    Niimi, H.4
  • 22
    • 36049025607 scopus 로고    scopus 로고
    • Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos
    • DOI 10.1088/0967-3334/28/10/002, PII S0967333407468125
    • J. Y. Lee, H. S. Ji, and S. J. Lee, "Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos," Physiol. Meas. 28(10), 1149-1162 (2007). (Pubitemid 350093337)
    • (2007) Physiological Measurement , vol.28 , Issue.10 , pp. 1149-1162
    • Lee, J.Y.1    Ji, H.S.2    Lee, S.J.3
  • 23
    • 0004073937 scopus 로고
    • Microscopy apparatus
    • US patent 3013467
    • M. Minsky, "Microscopy apparatus," US patent 3013467 (1961).
    • (1961)
    • Minsky, M.1
  • 25
    • 3142690382 scopus 로고    scopus 로고
    • Optically sliced micro-PIV using confocal laser scanning microscopy (CLSM)
    • J. S. Park, C. K. Choi, and K. D. Kihm, "Optically sliced micro-PIV using confocal laser scanning microscopy (CLSM)," Exp. Fluids 37(1), 105-119 (2004). (Pubitemid 38935629)
    • (2004) Experiments in Fluids , vol.37 , Issue.1 , pp. 105-119
    • Park, J.S.1    Choi, C.K.2    Kihm, K.D.3
  • 26
    • 33847342176 scopus 로고    scopus 로고
    • Three-dimensional measurement and visualization of internal flow of a moving droplet using confocal micro-PIV
    • DOI 10.1039/b617391h
    • H. Kinoshita, S. Kaneda, T. Fujii, and M. Oshima, "Three-dimensional measurement and visualization of internal flow of a moving droplet using confocal micro-PIV," Lab Chip 7(3), 338-346 (2007). (Pubitemid 46348319)
    • (2007) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.7 , Issue.3 , pp. 338-346
    • Kinoshita, H.1    Kaneda, S.2    Fujii, T.3    Oshima, M.4
  • 27
    • 34547758445 scopus 로고    scopus 로고
    • In vitro confocal micro-PIV measurements of blood flow in a square microchannel: The effect of the haematocrit on instantaneous velocity profiles
    • DOI 10.1016/j.jbiomech.2007.01.012, PII S0021929007000401
    • R. Lima, S. Wada, M. Takeda, K. Tsubota, and T. Yamaguchi, "In vitro confocal micro-PIV measurements of blood flow in a square microchannel: the effect of the haematocrit on instantaneous velocity profiles," J. Biomech. 40(12), 2752-2757 (2007). (Pubitemid 47238099)
    • (2007) Journal of Biomechanics , vol.40 , Issue.12 , pp. 2752-2757
    • Lima, R.1    Wada, S.2    Takeda, M.3    Tsubota, K.-i.4    Yamaguchi, T.5
  • 28
    • 77953150992 scopus 로고    scopus 로고
    • Particle image velocimetry of the blood flow in a micro-tube using the confocal laser scanning microscope
    • W. H. Kim, C. I. Kim, S. W. Lee, S. H. Lim, C. W. Park, H. Lee, and M. K. Park, "Particle image velocimetry of the blood flow in a micro-tube using the confocal laser scanning microscope," J. Opt. Soc. Korea 14(1), 42-48 (2010).
    • (2010) J. Opt. Soc. Korea , vol.14 , Issue.1 , pp. 42-48
    • Kim, W.H.1    Kim, C.I.2    Lee, S.W.3    Lim, S.H.4    Park, C.W.5    Lee, H.6    Park, M.K.7
  • 30
    • 34249836756 scopus 로고
    • Theory of cross-correlation analysis of PIV images
    • R. D. Keane, and R. J. Adrian, "Theory of cross-correlation analysis of PIV images," Appl. Sci. Res. 49(3), 191-215 (1992).
    • (1992) Appl. Sci. Res. , vol.49 , Issue.3 , pp. 191-215
    • Keane, R.D.1    Adrian, R.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.