메뉴 건너뛰기




Volumn 45, Issue 4, 2008, Pages 703-713

In vivo blood flow and wall shear stress measurements in the vitelline network

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; FLOW VISUALIZATION; HEMODYNAMICS; METALLURGY; NETWORK PROTOCOLS; SENSOR NETWORKS; SHEAR STRESS; SIGNAL TO NOISE RATIO; STRENGTH OF MATERIALS; THREE DIMENSIONAL; VELOCIMETERS; VELOCITY MEASUREMENT;

EID: 54049135311     PISSN: 07234864     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00348-008-0476-6     Document Type: Article
Times cited : (84)

References (36)
  • 2
    • 0038275771 scopus 로고    scopus 로고
    • Chorioallantoic membrane angiogenesis model for tissue engineering: A new twist on a classic model
    • 3
    • J Borges FT Tegtmeier NT Padron MC Mueller EM Lang GB Stark 2003 Chorioallantoic membrane angiogenesis model for tissue engineering: a new twist on a classic model Tissue Eng 9 3 441 450
    • (2003) Tissue Eng , vol.9 , pp. 441-450
    • Borges, J.1    Tegtmeier, F.T.2    Padron, N.T.3    Mueller, M.C.4    Lang, E.M.5    Stark, G.B.6
  • 3
    • 33846657968 scopus 로고    scopus 로고
    • Three-component micro-PIV using the continuity equation and a comparison of the performance with that of stereoscopic measurements
    • 2
    • MR Bown JM [tmp] MacInnes RWK Allen 2007 Three-component micro-PIV using the continuity equation and a comparison of the performance with that of stereoscopic measurements Exp Fluids 42 2 197 205
    • (2007) Exp Fluids , vol.42 , pp. 197-205
    • Bown, M.R.1    MacInnes, J.M.2    Allen, R.W.K.3
  • 4
    • 0014958503 scopus 로고
    • Shear dependence of effective cell volume as a determinant of blood viscosity
    • S Chien 1970 Shear dependence of effective cell volume as a determinant of blood viscosity Science 168 977 979
    • (1970) Science , vol.168 , pp. 977-979
    • Chien, S.1
  • 5
    • 30744476478 scopus 로고    scopus 로고
    • Retinal angiogenesis in development and disease
    • 7070
    • RF Gariano TW Gardner 2005 Retinal angiogenesis in development and disease Nature 438 7070 960 966
    • (2005) Nature , vol.438 , pp. 960-966
    • Gariano, R.F.1    Gardner, T.W.2
  • 6
    • 84924926133 scopus 로고
    • A series of normal stages in the development of the chick embryo
    • 1
    • V Hamburger HL Hamilton 1951 A series of normal stages in the development of the chick embryo J Morphol 88 1 49 92
    • (1951) J Morphol , vol.88 , pp. 49-92
    • Hamburger, V.1    Hamilton, H.L.2
  • 8
    • 0030911999 scopus 로고    scopus 로고
    • Unilateral vitelline vein ligation alters intracardiac blood flow patterns and morphogenesis in the chick embryo
    • B Hogers MC De Ruiter AC Grittenberger-de Groot RE Poelmann 1997 Unilateral vitelline vein ligation alters intracardiac blood flow patterns and morphogenesis in the chick embryo Circ Res 80 473 481
    • (1997) Circ Res , vol.80 , pp. 473-481
    • Hogers, B.1    De Ruiter, M.C.2    Grittenberger-De Groot, A.C.3    Poelmann, R.E.4
  • 9
    • 35348847063 scopus 로고    scopus 로고
    • Cell mechanics: Integrating cell responses to mechanical stimuli
    • PA Janmey CA [tmp] McCulloch 2007 Cell mechanics: integrating cell responses to mechanical stimuli Annu Rev Biomed Eng 9 1 34
    • (2007) Annu Rev Biomed Eng , vol.9 , pp. 1-34
    • Janmey, P.A.1    McCulloch, C.A.2
  • 10
    • 34249836756 scopus 로고
    • Theory of cross-correlation analysis of PIV analysis
    • RD Keane RJ Adrian 1992 Theory of cross-correlation analysis of PIV analysis Appl Sci Res 49 191 215
    • (1992) Appl Sci Res , vol.49 , pp. 191-215
    • Keane, R.D.1    Adrian, R.J.2
  • 11
    • 0016804345 scopus 로고
    • The development of the circulating blood volume of the chick embryo
    • 2
    • C Kind 1975 The development of the circulating blood volume of the chick embryo Anat Embryol 147 2 127 132
    • (1975) Anat Embryol , vol.147 , pp. 127-132
    • Kind, C.1
  • 12
    • 0021966255 scopus 로고
    • Pulsatile flow and atherosclerosis in the human carotid bifurcation. positive correlation between plaque location and low oscillating shear stress
    • 3
    • DN Ku DP Giddens CK Zarins S Glagov 1985 Pulsatile flow and atherosclerosis in the human carotid bifurcation. positive correlation between plaque location and low oscillating shear stress Arterioscler Thromb Vasc Biol 5 3 293 302
    • (1985) Arterioscler Thromb Vasc Biol , vol.5 , pp. 293-302
    • Ku, D.N.1    Giddens, D.P.2    Zarins, C.K.3    Glagov, S.4
  • 15
    • 36049025607 scopus 로고    scopus 로고
    • Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos
    • 10
    • JY Lee HS Ji SJ Lee 2007 Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos Physiol Meas 28 10 1149 1162
    • (2007) Physiol Meas , vol.28 , pp. 1149-1162
    • Lee, J.Y.1    Ji, H.S.2    Lee, S.J.3
  • 16
    • 0027857106 scopus 로고
    • Dorsal skinfold chamber technique for intravital microscopy in nude mice
    • 4
    • HA Lehr M Leunig MD Menger D Nolte K Messmer 1993 Dorsal skinfold chamber technique for intravital microscopy in nude mice Am J Pathol 143 4 1055 1062
    • (1993) Am J Pathol , vol.143 , pp. 1055-1062
    • Lehr, H.A.1    Leunig, M.2    Menger, M.D.3    Nolte, D.4    Messmer, K.5
  • 17
    • 33746313582 scopus 로고    scopus 로고
    • Stereoscopic micro particle image velocimetry
    • 2
    • R Lindken J Westerweel B Wieneke 2006 Stereoscopic micro particle image velocimetry Exp Fluids 41 2 161 171
    • (2006) Exp Fluids , vol.41 , pp. 161-171
    • Lindken, R.1    Westerweel, J.2    Wieneke, B.3
  • 20
    • 0001241499 scopus 로고    scopus 로고
    • A PIV algorithm for estimating time-averaged velocity fields
    • 2
    • CD Meinhart ST Wereley JG Santiago 2000 A PIV algorithm for estimating time-averaged velocity fields J Fluids Eng 122 2 285 289
    • (2000) J Fluids Eng , vol.122 , pp. 285-289
    • Meinhart, C.D.1    Wereley, S.T.2    Santiago, J.G.3
  • 21
    • 47949129276 scopus 로고    scopus 로고
    • Out-of-focus effects on particle image visibility and correlation in microscopic particle image velocimetry
    • MG Olsen RJ Adrian 2000 Out-of-focus effects on particle image visibility and correlation in microscopic particle image velocimetry Exp Fluids 29 166 174
    • (2000) Exp Fluids , vol.29 , pp. 166-174
    • Olsen, M.G.1    Adrian, R.J.2
  • 23
    • 33746121289 scopus 로고    scopus 로고
    • Wall shear stress-an important determinant of endothelial cell function and structure-in the arterial system in vivo; Discrepancies with theory
    • 3
    • RS Reneman T Arts APG Hoeks 2006 Wall shear stress-an important determinant of endothelial cell function and structure-in the arterial system in vivo; discrepancies with theory J Vasc Res 43 3 251 269
    • (2006) J Vasc Res , vol.43 , pp. 251-269
    • Reneman, R.S.1    Arts, T.2    Hoeks, A.P.G.3
  • 25
    • 24144464290 scopus 로고    scopus 로고
    • Velocity measurement of both red blood cells and plasma of in vitro blood flow using high-speed micro PIV technique
    • 5
    • Y Sugii R Okuda K Okamoto H Madarame 2005 Velocity measurement of both red blood cells and plasma of in vitro blood flow using high-speed micro PIV technique Meas Sci Technol 16 5 1126 1130
    • (2005) Meas Sci Technol , vol.16 , pp. 1126-1130
    • Sugii, Y.1    Okuda, R.2    Okamoto, K.3    Madarame, H.4
  • 26
    • 0032613071 scopus 로고    scopus 로고
    • Blood flow and vascular gene expression: Fluid shear stress as a modulator of endothelial phenotype
    • 1
    • JN Topper MA Gimbrone Jr 1999 Blood flow and vascular gene expression: fluid shear stress as a modulator of endothelial phenotype Mol Med Today 5 1 40 46
    • (1999) Mol Med Today , vol.5 , pp. 40-46
    • Topper, J.N.1    Gimbrone Jr, M.A.2
  • 29
    • 54049095603 scopus 로고    scopus 로고
    • Volumetric particle image velocimetry in the developing chicken heart
    • P Vennemann R Lindken BP Hierck J Westerweel 2006 Volumetric particle image velocimetry in the developing chicken heart J Biomech 39 S616
    • (2006) J Biomech , vol.39 , pp. 616
    • Vennemann, P.1    Lindken, R.2    Hierck, B.P.3    Westerweel, J.4
  • 30
    • 39849110971 scopus 로고    scopus 로고
    • In vivo whole-field blood velocity measurement techniques
    • P Vennemann R Lindken J Westerweel 2007 In vivo whole-field blood velocity measurement techniques Exp Fluids 42 495 511
    • (2007) Exp Fluids , vol.42 , pp. 495-511
    • Vennemann, P.1    Lindken, R.2    Westerweel, J.3
  • 31
    • 0025358067 scopus 로고
    • Effect of changes in circulating blood volume on cardiac output and arterial and ventricular blood pressure in the stage 18, 24 and 29 chick embryo
    • AJ Wagman N Hu EB Clark 1990 Effect of changes in circulating blood volume on cardiac output and arterial and ventricular blood pressure in the stage 18, 24 and 29 chick embryo Circ Res 67 187 192
    • (1990) Circ Res , vol.67 , pp. 187-192
    • Wagman, A.J.1    Hu, N.2    Clark, E.B.3
  • 32
  • 33
    • 42149165394 scopus 로고    scopus 로고
    • On velocity gradients in PIV interrogation
    • doi: 10.1007/s00348-007-0439-3
    • Westerweel J (2008) On velocity gradients in PIV interrogation. Exp Fluids. doi: 10.1007/s00348-007-0439-3
    • (2008) Exp Fluids
    • Westerweel, J.1
  • 34
    • 28044437343 scopus 로고    scopus 로고
    • Universal outlier detection for PIV data
    • 6
    • J Westerweel F Scarano 2005 Universal outlier detection for PIV data Exp Fluids 39 6 1096 1100
    • (2005) Exp Fluids , vol.39 , pp. 1096-1100
    • Westerweel, J.1    Scarano, F.2
  • 36
    • 0031354164 scopus 로고    scopus 로고
    • Stereoscopic digital particle image velocimetry for application in wind tunnel flows
    • CE Willert 1997 Stereoscopic digital particle image velocimetry for application in wind tunnel flows Meas Sci Technol 8 1465 1479
    • (1997) Meas Sci Technol , vol.8 , pp. 1465-1479
    • Willert, C.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.