메뉴 건너뛰기




Volumn 4, Issue 2, 2011, Pages 247-255

Vasomotor function after paclitaxel-coated balloon post-dilation in porcine coronary stent model

Author keywords

acetylcholine; endothelial dysfunction; paclitaxel coated balloon

Indexed keywords

ACETYLCHOLINE; FIBRIN; GLYCERYL TRINITRATE; PACLITAXEL;

EID: 79952020735     PISSN: 19368798     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcin.2010.08.028     Document Type: Article
Times cited : (16)

References (37)
  • 8
    • 77949493350 scopus 로고    scopus 로고
    • Temporal changes in the use of drug-eluting stents for patients with nonST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention from 2006 to 2008: Results from the Can Rapid Risk Stratification of Unstable Angina Patients Suppress Adverse Outcomes with Early Implementation of the ACC/AHA Guidelines (CRUSADE)
    • CRUSADE and ACTION-GWTG Registry Participants
    • M.T. Roe, A.Y. Chen, C.P. Cannon CRUSADE and ACTION-GWTG Registry Participants Temporal changes in the use of drug-eluting stents for patients with nonST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention from 2006 to 2008: results from the Can Rapid Risk Stratification of Unstable Angina Patients Suppress Adverse Outcomes With Early Implementation of the ACC/AHA Guidelines (CRUSADE) and Acute Coronary Treatment and Intervention Outcomes NetworkGet With the Guidelines (ACTION-GWTG) registries Circ Cardiovasc Qual Outcomes 2 2009 414 420
    • (2009) Circ Cardiovasc Qual Outcomes , vol.2 , pp. 414-420
    • Roe, M.T.1    Chen, A.Y.2    Cannon, C.P.3
  • 12
    • 0034718513 scopus 로고    scopus 로고
    • Intrapericardial paclitaxel delivery inhibits neointimal proliferation and promotes arterial enlargement after porcine coronary overstretch
    • D. Hou, P.I. Rogers, P.M. Toleikis, W. Hunter, and K.L. March Intrapericardial paclitaxel delivery inhibits neointimal proliferation and promotes arterial enlargement after porcine coronary overstretch Circulation 102 2000 1575 1581
    • (2000) Circulation , vol.102 , pp. 1575-1581
    • Hou, D.1    Rogers, P.I.2    Toleikis, P.M.3    Hunter, W.4    March, K.L.5
  • 14
    • 54749146427 scopus 로고    scopus 로고
    • Attainment of local drug delivery with paclitaxel-eluting balloon in porcine coronary arteries
    • A. Posa, R. Hemetsberger, and O. Petnehazy Attainment of local drug delivery with paclitaxel-eluting balloon in porcine coronary arteries Coron Artery Dis 19 2008 243 247
    • (2008) Coron Artery Dis , vol.19 , pp. 243-247
    • Posa, A.1    Hemetsberger, R.2    Petnehazy, O.3
  • 15
    • 60849087970 scopus 로고    scopus 로고
    • Drug-eluting balloon: Very short-term exposure and overlapping
    • B. Cremers, U. Speck, and N. Kaufels Drug-eluting balloon: very short-term exposure and overlapping Thromb Haemost 101 2009 201 206
    • (2009) Thromb Haemost , vol.101 , pp. 201-206
    • Cremers, B.1    Speck, U.2    Kaufels, N.3
  • 17
    • 52449104783 scopus 로고    scopus 로고
    • Two-year follow-up after treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter
    • B. Scheller, C. Hehrlein, and W. Bocksch Two-year follow-up after treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter Clin Res Cardiol 97 2008 773 781
    • (2008) Clin Res Cardiol , vol.97 , pp. 773-781
    • Scheller, B.1    Hehrlein, C.2    Bocksch, W.3
  • 18
    • 67649516634 scopus 로고    scopus 로고
    • Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis
    • M. Unverdorben, C. Vallbracht, and B. Cremers Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis Circulation 119 2009 2986 2994
    • (2009) Circulation , vol.119 , pp. 2986-2994
    • Unverdorben, M.1    Vallbracht, C.2    Cremers, B.3
  • 19
    • 72149107100 scopus 로고    scopus 로고
    • The first-generation drug-eluting stents and coronary endothelial dysfunction
    • L.K. Pendyala, X. Yin, J. Li, J.P. Chen, N. Chronos, and D. Hou The first-generation drug-eluting stents and coronary endothelial dysfunction J Am Coll Cardiol Intv 2 2009 1169 1177
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 1169-1177
    • Pendyala, L.K.1    Yin, X.2    Li, J.3    Chen, J.P.4    Chronos, N.5    Hou, D.6
  • 24
    • 4143067824 scopus 로고    scopus 로고
    • Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis
    • DOI 10.1161/01.CIR.0000138929.71660.E0
    • B. Scheller, U. Speck, C. Abramjuk, U. Bernhardt, M. Bohm, and G. Nickenig Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis Circulation 110 2004 810 814 (Pubitemid 39096008)
    • (2004) Circulation , vol.110 , Issue.7 , pp. 810-814
    • Scheller, B.1    Speck, U.2    Abramjuk, C.3    Bernhardt, U.4    Bohm, M.5    Nickenig, G.6
  • 25
    • 67349113986 scopus 로고    scopus 로고
    • Low-dose paclitaxel elution by novel bioerodible sol-gel coating on stents inhibits neointima with low toxicity in porcine coronary arteries
    • T. Shinke, S. Geva, and L. Pendyala Low-dose paclitaxel elution by novel bioerodible sol-gel coating on stents inhibits neointima with low toxicity in porcine coronary arteries Int J Cardiol 135 2009 93 101
    • (2009) Int J Cardiol , vol.135 , pp. 93-101
    • Shinke, T.1    Geva, S.2    Pendyala, L.3
  • 26
    • 0031885670 scopus 로고    scopus 로고
    • In-stent restenosis: Contributions of inflammatory responses and arterial injury to neointimal hyperplasia
    • DOI 10.1016/S0735-1097(97)00450-6, PII S0735109797004506
    • R. Kornowski, M.K. Hong, F.O. Tio, O. Bramwell, H. Wu, and M.B. Leon In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia J Am Coll Cardiol 31 1998 224 230 (Pubitemid 28064746)
    • (1998) Journal of the American College of Cardiology , vol.31 , Issue.1 , pp. 224-230
    • Kornowski, R.1    Hong, M.K.2    Tio, F.O.3    Bramwell, O.4    Wu, H.5    Leon, M.B.6
  • 27
    • 68249122647 scopus 로고    scopus 로고
    • Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis
    • S. Cook, E. Ladich, and G. Nakazawa Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis Circulation 120 2009 391 399
    • (2009) Circulation , vol.120 , pp. 391-399
    • Cook, S.1    Ladich, E.2    Nakazawa, G.3
  • 28
    • 34147176083 scopus 로고    scopus 로고
    • Stent thrombosis late after implantation of first-generation drug-eluting stents: A cause for concern
    • DOI 10.1161/CIRCULATIONAHA.106.666800, PII 0000301720070320000018
    • E. Camenzind, P.G. Steg, and W. Wijns Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern Circulation 115 2007 1440 1455 discussion 1455 (Pubitemid 46648381)
    • (2007) Circulation , vol.115 , Issue.11 , pp. 1440-1455
    • Camenzind, E.1    Steg, P.G.2    Wijns, W.3
  • 29
    • 51649119808 scopus 로고    scopus 로고
    • Incidence and correlates of drug-eluting stent thrombosis in routine clinical practice: 4-year results from a large 2-institutional cohort study
    • P. Wenaweser, J. Daemen, and M. Zwahlen Incidence and correlates of drug-eluting stent thrombosis in routine clinical practice: 4-year results from a large 2-institutional cohort study J Am Coll Cardiol 52 2008 1134 1140
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1134-1140
    • Wenaweser, P.1    Daemen, J.2    Zwahlen, M.3
  • 30
    • 33646252464 scopus 로고    scopus 로고
    • Incomplete neointimal coverage of sirolimus-eluting stents: Angioscopic findings
    • J. Kotani, M. Awata, and S. Nanto Incomplete neointimal coverage of sirolimus-eluting stents: angioscopic findings J Am Coll Cardiol 47 2006 2108 2111
    • (2006) J Am Coll Cardiol , vol.47 , pp. 2108-2111
    • Kotani, J.1    Awata, M.2    Nanto, S.3
  • 33
    • 67349193728 scopus 로고    scopus 로고
    • Comparison of two different paclitaxel-coated balloon catheters in the porcine coronary restenosis model
    • B. Cremers, M. Biedermann, D. Mahnkopf, M. Bohm, and B. Scheller Comparison of two different paclitaxel-coated balloon catheters in the porcine coronary restenosis model Clin Res Cardiol 98 2009 325 330
    • (2009) Clin Res Cardiol , vol.98 , pp. 325-330
    • Cremers, B.1    Biedermann, M.2    Mahnkopf, D.3    Bohm, M.4    Scheller, B.5
  • 34
    • 33746260417 scopus 로고    scopus 로고
    • Neointima inhibition: Comparison of effectiveness of non-stent-based local drug delivery and a drug-eluting stent in porcine coronary arteries
    • DOI 10.1148/radiol.2402051248
    • U. Speck, B. Scheller, and C. Abramjuk Neointima inhibition: comparison of effectiveness of non-stent-based local drug delivery and a drug-eluting stent in porcine coronary arteries Radiology 240 2006 411 418 (Pubitemid 44098636)
    • (2006) Radiology , vol.240 , Issue.2 , pp. 411-418
    • Speck, U.1    Scheller, B.2    Abramjuk, C.3    Breitwieser, C.4    Dobberstein, J.5    Boehm, M.6    Hamm, B.7
  • 35
    • 0034724932 scopus 로고    scopus 로고
    • Arterial paclitaxel distribution and deposition
    • C.J. Creel, M.A. Lovich, and E.R. Edelman Arterial paclitaxel distribution and deposition Circ Res 86 2000 879 884 (Pubitemid 30246985)
    • (2000) Circulation Research , vol.86 , Issue.8 , pp. 879-884
    • Creel, C.J.1    Lovich, M.A.2    Edelman, E.R.3
  • 37
    • 62149086297 scopus 로고    scopus 로고
    • Endothelium-dependent vasomotor dysfunction in pig coronary arteries with paclitaxel-eluting stents is associated with inflammation and oxidative stress
    • L.K. Pendyala, J. Li, and T. Shinke Endothelium-dependent vasomotor dysfunction in pig coronary arteries with paclitaxel-eluting stents is associated with inflammation and oxidative stress J Am Coll Cardiol Intv 2 2009 253 262
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 253-262
    • Pendyala, L.K.1    Li, J.2    Shinke, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.