메뉴 건너뛰기




Volumn 33, Issue 3, 2011, Pages 379-384

Influence of soft tissue artifacts on the calculated kinematics and kinetics of total knee replacements during sit-to-stand

Author keywords

Fluoroscopy; Kinematics; Kinetics; Motion analysis; Skin marker; Soft tissue artifact; Total knee replacement

Indexed keywords

ADDUCTION; AGED; ARTICLE; ARTIFACT; BIOMECHANICS; CLINICAL ARTICLE; FEMUR; FLEXOR REFLEX; FLUOROSCOPY; HUMAN; IN VIVO STUDY; KINEMATICS; KNEE ARTHROPLASTY; PRIORITY JOURNAL; PROSTHESIS; ROTATION; SITTING; SOFT TISSUE; STANDING; STEREOPHOTOGRAMMETRY; THIGH; TIBIA;

EID: 79952006512     PISSN: 09666362     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2010.12.007     Document Type: Article
Times cited : (40)

References (30)
  • 3
    • 0034307636 scopus 로고    scopus 로고
    • Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life?
    • Rowe P.J., Myles C.M., Walker C., Nutton R. Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life?. Gait Posture 2000, 12:143-155.
    • (2000) Gait Posture , vol.12 , pp. 143-155
    • Rowe, P.J.1    Myles, C.M.2    Walker, C.3    Nutton, R.4
  • 4
    • 0027538480 scopus 로고
    • Knee kinematics and kinetics during locomotor activities of daily living in subjects with knee arthroplasty and in healthy control subjects
    • Jevsevar D., Riley P., Hodge W., Krebs D. Knee kinematics and kinetics during locomotor activities of daily living in subjects with knee arthroplasty and in healthy control subjects. Phys Ther 1993, 73:229.
    • (1993) Phys Ther , vol.73 , pp. 229
    • Jevsevar, D.1    Riley, P.2    Hodge, W.3    Krebs, D.4
  • 5
    • 50449090069 scopus 로고    scopus 로고
    • How to quantify knee function after total knee arthroplasty?
    • Boonstra M.C., De Waal Malefijt M.C., Verdonschot N. How to quantify knee function after total knee arthroplasty?. Knee 2008, 15:390-395.
    • (2008) Knee , vol.15 , pp. 390-395
    • Boonstra, M.C.1    De Waal Malefijt, M.C.2    Verdonschot, N.3
  • 6
    • 24344457621 scopus 로고    scopus 로고
    • Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty
    • Mizner R.L., Snyder-Mackler L. Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty. J Orthop Res 2005, 23:1083-1090.
    • (2005) J Orthop Res , vol.23 , pp. 1083-1090
    • Mizner, R.L.1    Snyder-Mackler, L.2
  • 7
    • 0032051616 scopus 로고    scopus 로고
    • Rising from chair after total knee arthroplasty
    • Su F.C., Lai K.A., Hong W.H. Rising from chair after total knee arthroplasty. Clin Biomech 1998, 13:176-181.
    • (1998) Clin Biomech , vol.13 , pp. 176-181
    • Su, F.C.1    Lai, K.A.2    Hong, W.H.3
  • 8
    • 0030111274 scopus 로고    scopus 로고
    • Position and orientation in space of bones during movement: experimental artefacts
    • Cappozzo A., Catani F., Leardini A., Benedetti M., Croce U. Position and orientation in space of bones during movement: experimental artefacts. Clin Biomech 1996, 11:90-100.
    • (1996) Clin Biomech , vol.11 , pp. 90-100
    • Cappozzo, A.1    Catani, F.2    Leardini, A.3    Benedetti, M.4    Croce, U.5
  • 9
    • 19644398653 scopus 로고    scopus 로고
    • Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation
    • Leardini A., Chiari A., Della Croce U., Cappozzo A. Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. Gait Posture 2005, 21:212-225.
    • (2005) Gait Posture , vol.21 , pp. 212-225
    • Leardini, A.1    Chiari, A.2    Della Croce, U.3    Cappozzo, A.4
  • 10
    • 0031194416 scopus 로고    scopus 로고
    • Effect of skin movement on the analysis of skeletal knee joint motion during running
    • Reinschmidt C., van den Bogert A.J., Nigg B.M., Lundberg A., Murphy N. Effect of skin movement on the analysis of skeletal knee joint motion during running. J Biomech 1997, 30:729-732.
    • (1997) J Biomech , vol.30 , pp. 729-732
    • Reinschmidt, C.1    van den Bogert, A.J.2    Nigg, B.M.3    Lundberg, A.4    Murphy, N.5
  • 11
    • 0033980146 scopus 로고    scopus 로고
    • Comparison of surface mounted markers and attachment methods in estimating tibial rotations during walking: an in vivo study
    • Manal K., McClay I., Stanhope S., Richards J., Galinat B. Comparison of surface mounted markers and attachment methods in estimating tibial rotations during walking: an in vivo study. Gait Posture 2000, 11:38-45.
    • (2000) Gait Posture , vol.11 , pp. 38-45
    • Manal, K.1    McClay, I.2    Stanhope, S.3    Richards, J.4    Galinat, B.5
  • 12
    • 33748704922 scopus 로고    scopus 로고
    • Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging
    • Sangeux M., Marin F., Charleux F., Durselen L., Ho Ba Tho M.C. Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging. Clin Biomech 2006, 21:984-991.
    • (2006) Clin Biomech , vol.21 , pp. 984-991
    • Sangeux, M.1    Marin, F.2    Charleux, F.3    Durselen, L.4    Ho Ba Tho, M.C.5
  • 13
    • 0001572739 scopus 로고    scopus 로고
    • Quantitative assessment of skin-bone movement at the knee
    • Sati M., de Guise J.A., Larouche S., Drouin G. Quantitative assessment of skin-bone movement at the knee. Knee 1996, 3:121-138.
    • (1996) Knee , vol.3 , pp. 121-138
    • Sati, M.1    de Guise, J.A.2    Larouche, S.3    Drouin, G.4
  • 14
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • Banks S.A., Hodge W.A. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng 1996, 43:638-649.
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 638-649
    • Banks, S.A.1    Hodge, W.A.2
  • 15
    • 13844256386 scopus 로고    scopus 로고
    • Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjects
    • Stagni R., Fantozzi S., Cappello A., Leardini A. Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjects. Clin Biomech 2005, 20:320-329.
    • (2005) Clin Biomech , vol.20 , pp. 320-329
    • Stagni, R.1    Fantozzi, S.2    Cappello, A.3    Leardini, A.4
  • 16
    • 77749292316 scopus 로고    scopus 로고
    • A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy
    • Tsai T.Y., Lu T.W., Chen C.M., Kuo M.Y., Hsu H.C. A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy. Med Phys 2010, 37:1273-1284.
    • (2010) Med Phys , vol.37 , pp. 1273-1284
    • Tsai, T.Y.1    Lu, T.W.2    Chen, C.M.3    Kuo, M.Y.4    Hsu, H.C.5
  • 17
    • 68249084601 scopus 로고    scopus 로고
    • Quantification of three-dimensional movement of skin markers relative to the underlying bones during functional activities
    • Tsai T.Y., Lu T.W., Kuo M.Y., Hsu H.C. Quantification of three-dimensional movement of skin markers relative to the underlying bones during functional activities. Biomed Eng Appl Basis Commun. 2009, 21:223-232.
    • (2009) Biomed Eng Appl Basis Commun. , vol.21 , pp. 223-232
    • Tsai, T.Y.1    Lu, T.W.2    Kuo, M.Y.3    Hsu, H.C.4
  • 18
    • 0029311073 scopus 로고
    • Position and orientation in space of bones during movement: anatomical frame definition and determination
    • Cappozzo A., Catani F., Della Croce U., Leardini A. Position and orientation in space of bones during movement: anatomical frame definition and determination. Clin Biomech 1995, 10:171-178.
    • (1995) Clin Biomech , vol.10 , pp. 171-178
    • Cappozzo, A.1    Catani, F.2    Della Croce, U.3    Leardini, A.4
  • 19
    • 53049090828 scopus 로고    scopus 로고
    • In vivo three-dimensional kinematics of the normal knee during active extension under unloaded and loaded conditions using single-plane fluoroscopy
    • Lu T.W., Tsai T.Y., Kuo M.Y., Hsu H.C., Chen H.L. In vivo three-dimensional kinematics of the normal knee during active extension under unloaded and loaded conditions using single-plane fluoroscopy. Med Eng Phys 2008, 30:1004-1012.
    • (2008) Med Eng Phys , vol.30 , pp. 1004-1012
    • Lu, T.W.1    Tsai, T.Y.2    Kuo, M.Y.3    Hsu, H.C.4    Chen, H.L.5
  • 20
    • 79952002633 scopus 로고    scopus 로고
    • Development of a 3D fluoroscopy method and its integration with stereophotogrammetry to study the effects of soft tissue artifacts on the calculated mechanical variables of the knee during functional activities. Ph.D. Thesis. Taipei, Taiwan: National Taiwan University
    • Tsai, TY. Development of a 3D fluoroscopy method and its integration with stereophotogrammetry to study the effects of soft tissue artifacts on the calculated mechanical variables of the knee during functional activities. Ph.D. Thesis. Taipei, Taiwan: National Taiwan University; 2010.
    • (2010)
    • Tsai, T.Y.1
  • 21
    • 2542471541 scopus 로고    scopus 로고
    • Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy
    • Yamazaki T., Watanabe T., Nakajima Y., Sugamoto K., Tomita T., Yoshikawa H., et al. Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy. IEEE Trans Med Imaging 2004, 23:602-612.
    • (2004) IEEE Trans Med Imaging , vol.23 , pp. 602-612
    • Yamazaki, T.1    Watanabe, T.2    Nakajima, Y.3    Sugamoto, K.4    Tomita, T.5    Yoshikawa, H.6
  • 22
    • 79952008505 scopus 로고    scopus 로고
    • Geometric and mechanical modelling of the human locomotor system. D.Phil. Thesis. Oxford, UK: University of Oxford
    • Lu TW. Geometric and mechanical modelling of the human locomotor system. D.Phil. Thesis. Oxford, UK: University of Oxford; 1997.
    • (1997)
    • Lu, T.W.1
  • 23
    • 0027703664 scopus 로고
    • Application of the joint coordinate system to three-dimensional joint attitude and movement representation: a standardization proposal
    • Cole G.K., Nigg B.M., Ronsky J.L., Yeadon M.R. Application of the joint coordinate system to three-dimensional joint attitude and movement representation: a standardization proposal. J Biomech Eng 1993, 115:344-349.
    • (1993) J Biomech Eng , vol.115 , pp. 344-349
    • Cole, G.K.1    Nigg, B.M.2    Ronsky, J.L.3    Yeadon, M.R.4
  • 24
    • 0031947762 scopus 로고    scopus 로고
    • The relative skin movement of the foot: a 2-D roentgen photogrammetry study
    • Tranberg R., Karlsson D. The relative skin movement of the foot: a 2-D roentgen photogrammetry study. Clin Biomech 1998, 13:71-76.
    • (1998) Clin Biomech , vol.13 , pp. 71-76
    • Tranberg, R.1    Karlsson, D.2
  • 26
    • 0030271913 scopus 로고    scopus 로고
    • Standing-up in healthy subjects: symmetry of weight distribution and lateral displacement of the centre of mass as related to limb dominance
    • Hesse S., Schauer M., Jahnke M.T. Standing-up in healthy subjects: symmetry of weight distribution and lateral displacement of the centre of mass as related to limb dominance. Gait Posture 1996, 4:287-292.
    • (1996) Gait Posture , vol.4 , pp. 287-292
    • Hesse, S.1    Schauer, M.2    Jahnke, M.T.3
  • 27
    • 0022699297 scopus 로고
    • A Fortran package for generalized, cross-validatory spline smoothing and differentiation
    • Woltring H.J. A Fortran package for generalized, cross-validatory spline smoothing and differentiation. Adv Eng Softw 1986, 8:104-113.
    • (1986) Adv Eng Softw , vol.8 , pp. 104-113
    • Woltring, H.J.1
  • 28
    • 0031408028 scopus 로고    scopus 로고
    • Inverse optimization: functional and physiological considerations related to the force-sharing problem
    • Tsirakos D., Baltzopoulos V., Bartlett R. Inverse optimization: functional and physiological considerations related to the force-sharing problem. Crit Rev Biomed Eng 1997, 25:371-407.
    • (1997) Crit Rev Biomed Eng , vol.25 , pp. 371-407
    • Tsirakos, D.1    Baltzopoulos, V.2    Bartlett, R.3
  • 29
    • 0344431241 scopus 로고    scopus 로고
    • Validation of a lower limb model with in vivo femoral forces telemetered from two subjects
    • Lu T.W., O'Connor J.J., Taylor S.J., Walker P.S. Validation of a lower limb model with in vivo femoral forces telemetered from two subjects. J Biomech 1998, 31:63-69.
    • (1998) J Biomech , vol.31 , pp. 63-69
    • Lu, T.W.1    O'Connor, J.J.2    Taylor, S.J.3    Walker, P.S.4
  • 30
    • 0033081306 scopus 로고    scopus 로고
    • Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints
    • Lu T.W., O'Connor J.J. Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. J Biomech 1999, 32:129-134.
    • (1999) J Biomech , vol.32 , pp. 129-134
    • Lu, T.W.1    O'Connor, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.