메뉴 건너뛰기




Volumn 77, Issue 3, 2011, Pages 213-222

Observing and quantifying airflows in the infection control of aerosol- and airborne-transmitted diseases: An overview of approaches

Author keywords

Aerosol; Airflow; Computational fluid dynamics; Mannequin; Schlieren; Transmission

Indexed keywords

AEROSOL; AIR TEMPERATURE; AIRBORNE INFECTION; AIRFLOW; ANEMOMETER; ANEMOMETRY; BODY TEMPERATURE; BREATHING; BREATHING MECHANICS; BREATHING RATE; COMPUTATIONAL FLUID DYNAMICS; COUGHING; CROSS INFECTION; DISEASE TRANSMISSION; FLOW MEASUREMENT; HEAT; HUMAN; HUMIDITY; IMAGING; INFECTION CONTROL; MANNEQUIN; OXYGEN MASK; PARTICLE IMAGE VELOCIMETRY; PATIENT MONITORING; PHYSICAL ANALOGUE MODEL; PLUME DISPERSION; RESUSCITATION; REVIEW; SCHLIEREN IMAGING; SECONDARY INFECTION; SEX DIFFERENCE; SIMULATION; SMOKE; TIDAL VOLUME; VELOCITY; VENTILATOR;

EID: 79951853008     PISSN: 01956701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhin.2010.09.037     Document Type: Review
Times cited : (119)

References (123)
  • 1
    • 10744229624 scopus 로고    scopus 로고
    • Cluster of SARS among medical students exposed to single patient, Hong Kong
    • Wong T.W., Lee C.K., Tam W., et al. Cluster of SARS among medical students exposed to single patient, Hong Kong. Emerg Infect Dis 2004, 10:269-276.
    • (2004) Emerg Infect Dis , vol.10 , pp. 269-276
    • Wong, T.W.1    Lee, C.K.2    Tam, W.3
  • 2
    • 1942467995 scopus 로고    scopus 로고
    • Evidence of airborne transmission of the severe acute respiratory syndrome virus
    • Yu I.T.S., Li Y., Wong T.W., et al. Evidence of airborne transmission of the severe acute respiratory syndrome virus. N Engl J Med 2004, 350:1731-1739.
    • (2004) N Engl J Med , vol.350 , pp. 1731-1739
    • Yu, I.T.S.1    Li, Y.2    Wong, T.W.3
  • 3
    • 67449110743 scopus 로고    scopus 로고
    • Emergence of a novel swine-origin influenza A (H1N1) virus in humans
    • Dawood F.S., Jain S., Finelli L., et al. Emergence of a novel swine-origin influenza A (H1N1) virus in humans. N Engl J Med 2009, 360:2605-2615.
    • (2009) N Engl J Med , vol.360 , pp. 2605-2615
    • Dawood, F.S.1    Jain, S.2    Finelli, L.3
  • 4
    • 67650866715 scopus 로고    scopus 로고
    • Dating the emergence of pandemic influenza viruses
    • Smith G.J., Bahl J., Vijaykrishna D., et al. Dating the emergence of pandemic influenza viruses. Proc Natl Acad Sci U S A 2009, 106:11709-11712.
    • (2009) Proc Natl Acad Sci U S A , vol.106 , pp. 11709-11712
    • Smith, G.J.1    Bahl, J.2    Vijaykrishna, D.3
  • 5
    • 67649227029 scopus 로고    scopus 로고
    • Emergence of a novel swine-origin influenza A virus (S-OIV) H1N1 virus in humans
    • Peiris J.S., Poon L.L., Guan Y. Emergence of a novel swine-origin influenza A virus (S-OIV) H1N1 virus in humans. J Clin Virol 2009, 45:169-173.
    • (2009) J Clin Virol , vol.45 , pp. 169-173
    • Peiris, J.S.1    Poon, L.L.2    Guan, Y.3
  • 6
    • 33750629996 scopus 로고    scopus 로고
    • Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises
    • Tang J.W., Li Y., Eames I., Chan P.K., Ridgway G.L. Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises. J Hosp Infect 2006, 64:100-114.
    • (2006) J Hosp Infect , vol.64 , pp. 100-114
    • Tang, J.W.1    Li, Y.2    Eames, I.3    Chan, P.K.4    Ridgway, G.L.5
  • 7
    • 33846592867 scopus 로고    scopus 로고
    • Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review
    • Li Y., Leung G.M., Tang J.W., et al. Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review. Indoor Air 2007, 17:2-18.
    • (2007) Indoor Air , vol.17 , pp. 2-18
    • Li, Y.1    Leung, G.M.2    Tang, J.W.3
  • 8
    • 20244361957 scopus 로고    scopus 로고
    • Detection of airborne severe acute respiratory syndrome (SARS) coronavirus and environmental contamination in SARS outbreak units
    • Booth T.F., Kournikakis B., Bastien N., et al. Detection of airborne severe acute respiratory syndrome (SARS) coronavirus and environmental contamination in SARS outbreak units. J Infect Dis 2005, 191:1472-1477.
    • (2005) J Infect Dis , vol.191 , pp. 1472-1477
    • Booth, T.F.1    Kournikakis, B.2    Bastien, N.3
  • 10
    • 58749100640 scopus 로고    scopus 로고
    • Measurement of airborne influenza virus in a hospital emergency department
    • Blachere F.M., Lindsley W.G., Pearce T.A., et al. Measurement of airborne influenza virus in a hospital emergency department. Clin Infect Dis 2009, 48:438-440.
    • (2009) Clin Infect Dis , vol.48 , pp. 438-440
    • Blachere, F.M.1    Lindsley, W.G.2    Pearce, T.A.3
  • 11
    • 49949084652 scopus 로고    scopus 로고
    • Influenza virus in human exhaled breath: an observational study
    • Fabian P., McDevitt J.J., DeHaan W.H., et al. Influenza virus in human exhaled breath: an observational study. PLoS One 2008, 3:e2691.
    • (2008) PLoS One , vol.3
    • Fabian, P.1    McDevitt, J.J.2    DeHaan, W.H.3
  • 13
    • 68949156451 scopus 로고    scopus 로고
    • Exhalation of respiratory viruses by breathing, coughing, and talking
    • Stelzer-Braid S., Oliver B.G., Blazey A.J., et al. Exhalation of respiratory viruses by breathing, coughing, and talking. J Med Virol 2009, 81:1674-1679.
    • (2009) J Med Virol , vol.81 , pp. 1674-1679
    • Stelzer-Braid, S.1    Oliver, B.G.2    Blazey, A.J.3
  • 14
    • 0031828818 scopus 로고    scopus 로고
    • Characterization of infectious aerosols in health care facilities: an aid to effective engineering controls and preventive strategies
    • Cole E.C., Cook C.E. Characterization of infectious aerosols in health care facilities: an aid to effective engineering controls and preventive strategies. Am J Infect Control 1998, 26:453-464.
    • (1998) Am J Infect Control , vol.26 , pp. 453-464
    • Cole, E.C.1    Cook, C.E.2
  • 15
    • 2342476359 scopus 로고    scopus 로고
    • Aerosols and splatter in dentistry
    • Harrel S.K., Molinari J. Aerosols and splatter in dentistry. J Am Dental Assoc 2004, 135:429-437.
    • (2004) J Am Dental Assoc , vol.135 , pp. 429-437
    • Harrel, S.K.1    Molinari, J.2
  • 16
    • 33750569806 scopus 로고    scopus 로고
    • Review of aerosol transmission of influenza A virus
    • Tellier R. Review of aerosol transmission of influenza A virus. Emerg Infect Dis 2006, 12:1657-1662.
    • (2006) Emerg Infect Dis , vol.12 , pp. 1657-1662
    • Tellier, R.1
  • 17
    • 71849088689 scopus 로고    scopus 로고
    • Aerosol transmission of influenza A virus: a review of new studies
    • Tellier R. Aerosol transmission of influenza A virus: a review of new studies. J R Soc Interface 2009, 6(Suppl. 6):S783-S790.
    • (2009) J R Soc Interface , vol.6 , Issue.SUPPL. 6
    • Tellier, R.1
  • 18
    • 73449139423 scopus 로고    scopus 로고
    • The effect of environmental parameters on the survival of airborne infectious agents
    • Tang J.W. The effect of environmental parameters on the survival of airborne infectious agents. J R Soc Interface 2009, 6(Suppl. 6):S737-S746.
    • (2009) J R Soc Interface , vol.6 , Issue.SUPPL. 6
    • Tang, J.W.1
  • 19
    • 74949093896 scopus 로고    scopus 로고
    • Incidence of common respiratory viral infections related to climate factors in hospitalized children in Hong Kong
    • Tang J.W., Lai F.Y., Wong F., Hon K.L. Incidence of common respiratory viral infections related to climate factors in hospitalized children in Hong Kong. Epidemiol Infect 2010, 138:226-235.
    • (2010) Epidemiol Infect , vol.138 , pp. 226-235
    • Tang, J.W.1    Lai, F.Y.2    Wong, F.3    Hon, K.L.4
  • 20
    • 0001855478 scopus 로고
    • Virus survival as a seasonal factor in influenza and poliomyelitis
    • Hemmes J.H., Winkler K.C., Kool S.M. Virus survival as a seasonal factor in influenza and poliomyelitis. Nature 1960, 188:430-431.
    • (1960) Nature , vol.188 , pp. 430-431
    • Hemmes, J.H.1    Winkler, K.C.2    Kool, S.M.3
  • 21
    • 0017132538 scopus 로고
    • Survival of airborne influenza virus: effects of propagating host, relative humidity, and composition of spray fluids
    • Schaffer F.L., Soergel M.E., Straube D.C. Survival of airborne influenza virus: effects of propagating host, relative humidity, and composition of spray fluids. Arch Virol 1976, 51:263-273.
    • (1976) Arch Virol , vol.51 , pp. 263-273
    • Schaffer, F.L.1    Soergel, M.E.2    Straube, D.C.3
  • 22
    • 36049022594 scopus 로고    scopus 로고
    • Influenza virus transmission is dependent on relative humidity and temperature
    • Lowen A.C., Mubareka S., Steel J., Palese P. Influenza virus transmission is dependent on relative humidity and temperature. PLoS Pathog 2007, 3:1470-1476.
    • (2007) PLoS Pathog , vol.3 , pp. 1470-1476
    • Lowen, A.C.1    Mubareka, S.2    Steel, J.3    Palese, P.4
  • 23
    • 43949134877 scopus 로고    scopus 로고
    • High temperature (30 degrees C) blocks aerosol but not contact transmission of influenza virus
    • Lowen A.C., Steel J., Mubareka S., Palese P. High temperature (30 degrees C) blocks aerosol but not contact transmission of influenza virus. J Virol 2008, 82:5650-5652.
    • (2008) J Virol , vol.82 , pp. 5650-5652
    • Lowen, A.C.1    Steel, J.2    Mubareka, S.3    Palese, P.4
  • 24
    • 0030911195 scopus 로고    scopus 로고
    • The size distribution of droplets in the exhaled breath of healthy human subjects
    • Papineni R.S., Rosenthal F.S. The size distribution of droplets in the exhaled breath of healthy human subjects. J Aerosol Med 1997, 10:105-116.
    • (1997) J Aerosol Med , vol.10 , pp. 105-116
    • Papineni, R.S.1    Rosenthal, F.S.2
  • 25
    • 33750983614 scopus 로고    scopus 로고
    • Bacterial survival in evaporating deposited droplets on a teflon-coated surface
    • Xie X., Li Y., Zhang T., Fang H.H. Bacterial survival in evaporating deposited droplets on a teflon-coated surface. Appl Microbiol Biotechnol 2006, 73:703-712.
    • (2006) Appl Microbiol Biotechnol , vol.73 , pp. 703-712
    • Xie, X.1    Li, Y.2    Zhang, T.3    Fang, H.H.4
  • 26
    • 34249703515 scopus 로고    scopus 로고
    • How far droplets can move in indoor environments - revisiting the Wells evaporation-falling curve
    • Xie X., Li Y., Chwang A.T., Ho P.L., Seto W.H. How far droplets can move in indoor environments - revisiting the Wells evaporation-falling curve. Indoor Air 2007, 17:211-225.
    • (2007) Indoor Air , vol.17 , pp. 211-225
    • Xie, X.1    Li, Y.2    Chwang, A.T.3    Ho, P.L.4    Seto, W.H.5
  • 27
    • 73449083384 scopus 로고    scopus 로고
    • Exhaled droplets due to talking and coughing
    • Xie X., Li Y., Sun H., Liu L. Exhaled droplets due to talking and coughing. J R Soc Interface 2009, 6(Suppl. 6):S703-S714.
    • (2009) J R Soc Interface , vol.6 , Issue.SUPPL. 6
    • Xie, X.1    Li, Y.2    Sun, H.3    Liu, L.4
  • 28
    • 34447537733 scopus 로고    scopus 로고
    • Transport characteristics of expiratory droplets and droplet nuclei in indoor environments with different ventilation airflow patterns
    • Wan M.P., Chao C.Y. Transport characteristics of expiratory droplets and droplet nuclei in indoor environments with different ventilation airflow patterns. J Biomech Engng 2007, 129:341-353.
    • (2007) J Biomech Engng , vol.129 , pp. 341-353
    • Wan, M.P.1    Chao, C.Y.2
  • 29
    • 51849166832 scopus 로고    scopus 로고
    • A methodology for estimating airborne virus exposures in indoor environments using the spatial distribution of expiratory aerosols and virus viability characteristics
    • Sze To G.N., Wan M.P., Chao C.Y.H., et al. A methodology for estimating airborne virus exposures in indoor environments using the spatial distribution of expiratory aerosols and virus viability characteristics. Indoor Air 2008, 18:425-438.
    • (2008) Indoor Air , vol.18 , pp. 425-438
    • Sze To, G.N.1    Wan, M.P.2    Chao, C.Y.H.3
  • 30
    • 37548999747 scopus 로고    scopus 로고
    • The size and concentration of droplets generated by coughing in human subjects
    • Yang S., Lee G.W., Chen C.M., Wu C.C., Yu K.P. The size and concentration of droplets generated by coughing in human subjects. J Aerosol Med 2007, 20:484-494.
    • (2007) J Aerosol Med , vol.20 , pp. 484-494
    • Yang, S.1    Lee, G.W.2    Chen, C.M.3    Wu, C.C.4    Yu, K.P.5
  • 31
    • 0030851442 scopus 로고    scopus 로고
    • Clinical recognition and management of patients exposed to biological warfare agents
    • Franz D.R., Jahrling P.B., Friedlander A.M., et al. Clinical recognition and management of patients exposed to biological warfare agents. J Am Med Assoc 1997, 278:399-411.
    • (1997) J Am Med Assoc , vol.278 , pp. 399-411
    • Franz, D.R.1    Jahrling, P.B.2    Friedlander, A.M.3
  • 32
    • 84872660210 scopus 로고    scopus 로고
    • An experimental study of human exhalation during breathing and coughing in a mixing ventilated room
    • In: Bogucz EA, editor. Proceedings of the healthy buildings 2009, 9th international conference and exhibition. Syracuse, NY, USA: 2009. Paper ID
    • Liu L, Li Y, Nielsen PV, Jensen RL, Litewnicki M, Zajas J. An experimental study of human exhalation during breathing and coughing in a mixing ventilated room. In: Bogucz EA, editor. Proceedings of the healthy buildings 2009, 9th international conference and exhibition. Syracuse, NY, USA: 2009. Paper ID: 162.
    • , vol.162
    • Liu, L.1    Li, Y.2    Nielsen, P.V.3    Jensen, R.L.4    Litewnicki, M.5    Zajas, J.6
  • 33
    • 84872658246 scopus 로고    scopus 로고
    • Plume above a standing human body exposed to different air distribution strategies. In: Bogucz EA, editor. Proceedings of the healthy buildings 2009, 9th international conference and exhibition. Syracuse, NY, USA: 2009. Paper ID
    • Liu L, Nielsen PV, Li Y, Jensen RL, Litewnicki M, Zajas J. Plume above a standing human body exposed to different air distribution strategies. In: Bogucz EA, editor. Proceedings of the healthy buildings 2009, 9th international conference and exhibition. Syracuse, NY, USA: 2009. Paper ID: 605.
    • , vol.605
    • Liu, L.1    Nielsen, P.V.2    Li, Y.3    Jensen, R.L.4    Litewnicki, M.5    Zajas, J.6
  • 34
    • 84872659473 scopus 로고    scopus 로고
    • Experiments on the microenvironment and breathing of a person in isothermal and stratified surroundings. In: Bogucz EA, editor. Proceedings of the healthy buildings 2009, 9th international conference and exhibition. Syracuse, NY, USA: 2009. Paper ID
    • Nielsen PV, Jensen RL, Litewnicki M, Zajas J. Experiments on the microenvironment and breathing of a person in isothermal and stratified surroundings. In: Bogucz EA, editor. Proceedings of the healthy buildings 2009, 9th international conference and exhibition. Syracuse, NY, USA: 2009. Paper ID: 374.
    • , vol.374
    • Nielsen, P.V.1    Jensen, R.L.2    Litewnicki, M.3    Zajas, J.4
  • 35
    • 73449111915 scopus 로고    scopus 로고
    • A Schlieren optical study of the human cough with and without wearing masks for aerosol infection control
    • Tang J.W., Liebner T.J., Craven B.A., Settles G.S. A Schlieren optical study of the human cough with and without wearing masks for aerosol infection control. J R Soc Interface 2009, 6(Suppl. 6):S727-S736.
    • (2009) J R Soc Interface , vol.6 , Issue.SUPPL. 6
    • Tang, J.W.1    Liebner, T.J.2    Craven, B.A.3    Settles, G.S.4
  • 36
    • 0019727271 scopus 로고
    • Temperature of expired air under variant climatic conditions
    • Höppe P. Temperature of expired air under variant climatic conditions. Int J Biometeor 1981, 25:127-128.
    • (1981) Int J Biometeor , vol.25 , pp. 127-128
    • Höppe, P.1
  • 37
    • 29144453314 scopus 로고    scopus 로고
    • On particle image velocimetry (PIV) measurements in the breathing zone of a thermal breathing mannequin
    • Marr D., Khan T., Glauser M., Higuchi H., Zhang J. On particle image velocimetry (PIV) measurements in the breathing zone of a thermal breathing mannequin. ASHRAE Trans 2005, 111:299-305.
    • (2005) ASHRAE Trans , vol.111 , pp. 299-305
    • Marr, D.1    Khan, T.2    Glauser, M.3    Higuchi, H.4    Zhang, J.5
  • 38
    • 41149089264 scopus 로고    scopus 로고
    • Anisotropy in the breathing zone of a thermal mannequin
    • Marr D.R., Spitzer I.M., Glauser M.N. Anisotropy in the breathing zone of a thermal mannequin. Exp Fluids 2008, 44:661-673.
    • (2008) Exp Fluids , vol.44 , pp. 661-673
    • Marr, D.R.1    Spitzer, I.M.2    Glauser, M.N.3
  • 39
    • 33746112635 scopus 로고    scopus 로고
    • Noncontact measurement of breathing function
    • M/J
    • Murthy R., Pavlidis I. Noncontact measurement of breathing function. IEEE Engng Med Biol Mag 2006; May/June, 57-67.
    • (2006) IEEE Engng Med Biol Mag , pp. 57-67
    • Murthy, R.1    Pavlidis, I.2
  • 40
    • 74049110127 scopus 로고    scopus 로고
    • Characterizing exhaled airflow from breathing and talking
    • Gupta J.K., Lin C.H., Chenn Q. Characterizing exhaled airflow from breathing and talking. Indoor Air 2010, 20:31-39.
    • (2010) Indoor Air , vol.20 , pp. 31-39
    • Gupta, J.K.1    Lin, C.H.2    Chenn, Q.3
  • 41
    • 33144458257 scopus 로고    scopus 로고
    • Global physiology and pathophysiology of cough: ACCP evidence-based clinical practice guidelines
    • McCool F.D. Global physiology and pathophysiology of cough: ACCP evidence-based clinical practice guidelines. Chest 2006, 129(1 Suppl.):48S-53S.
    • (2006) Chest , vol.129 , Issue.1 SUPPL.
    • McCool, F.D.1
  • 42
    • 70450163033 scopus 로고    scopus 로고
    • Flow dynamics and characterization of a cough
    • Gupta J.K., Lin C.H., Chenn Q. Flow dynamics and characterization of a cough. Indoor Air 2009, 19:517-525.
    • (2009) Indoor Air , vol.19 , pp. 517-525
    • Gupta, J.K.1    Lin, C.H.2    Chenn, Q.3
  • 43
    • 33748424508 scopus 로고    scopus 로고
    • Unsteady flow measurements of human micro environment using time resolved particle image velocimetry
    • Coimbra, Portugal, M.C. Gameiro da Silva (Ed.)
    • Khan T.A., Higuchi H., Marr D.R., Glauser M.N. Unsteady flow measurements of human micro environment using time resolved particle image velocimetry. 9th International conference on air distribution in rooms 2004, 350. Coimbra, Portugal. M.C. Gameiro da Silva (Ed.).
    • (2004) 9th International conference on air distribution in rooms , pp. 350
    • Khan, T.A.1    Higuchi, H.2    Marr, D.R.3    Glauser, M.N.4
  • 46
    • 33748881976 scopus 로고    scopus 로고
    • Airflows around oxygen masks: a potential source of infection?
    • Hui D.S., Ip M., Tang J.W., et al. Airflows around oxygen masks: a potential source of infection?. Chest 2006, 130:822-826.
    • (2006) Chest , vol.130 , pp. 822-826
    • Hui, D.S.1    Ip, M.2    Tang, J.W.3
  • 47
    • 33748857154 scopus 로고    scopus 로고
    • Noninvasive positive-pressure ventilation: an experimental model to assess air and particle dispersion
    • Hui D.S., Hall S.D., Chan M.T., et al. Noninvasive positive-pressure ventilation: an experimental model to assess air and particle dispersion. Chest 2006, 130:730-740.
    • (2006) Chest , vol.130 , pp. 730-740
    • Hui, D.S.1    Hall, S.D.2    Chan, M.T.3
  • 48
    • 34548035434 scopus 로고    scopus 로고
    • Exhaled air dispersion during oxygen delivery via a simple oxygen mask
    • Hui D.S., Hall S.D., Chan M.T., et al. Exhaled air dispersion during oxygen delivery via a simple oxygen mask. Chest 2007, 132:540-546.
    • (2007) Chest , vol.132 , pp. 540-546
    • Hui, D.S.1    Hall, S.D.2    Chan, M.T.3
  • 49
    • 62149145742 scopus 로고    scopus 로고
    • Exhaled air and aerosolized droplet dispersion during application of a jet nebulizer
    • Hui D.S., Chow B.K., Chu L.C., et al. Exhaled air and aerosolized droplet dispersion during application of a jet nebulizer. Chest 2009, 135:648-654.
    • (2009) Chest , vol.135 , pp. 648-654
    • Hui, D.S.1    Chow, B.K.2    Chu, L.C.3
  • 50
    • 70349973475 scopus 로고    scopus 로고
    • Exhaled air dispersion distances during noninvasive ventilation via different respironics face masks
    • Hui D.S., Chow B.K., Ng S.S., et al. Exhaled air dispersion distances during noninvasive ventilation via different respironics face masks. Chest 2009, 136:998-1005.
    • (2009) Chest , vol.136 , pp. 998-1005
    • Hui, D.S.1    Chow, B.K.2    Ng, S.S.3
  • 51
    • 36549009481 scopus 로고    scopus 로고
    • Airflow and droplet spreading around oxygen masks: a simulation model for infection control research
    • Ip M., Tang J.W., Hui D.S., et al. Airflow and droplet spreading around oxygen masks: a simulation model for infection control research. Am J Infect Control 2007, 35:684-689.
    • (2007) Am J Infect Control , vol.35 , pp. 684-689
    • Ip, M.1    Tang, J.W.2    Hui, D.S.3
  • 52
    • 70349921770 scopus 로고    scopus 로고
    • The consequences of withholding noninvasive ventilation during an epidemic
    • McCracken J. The consequences of withholding noninvasive ventilation during an epidemic. Respir Care 2009, 54:1412.
    • (2009) Respir Care , vol.54 , pp. 1412
    • McCracken, J.1
  • 53
    • 71049189240 scopus 로고    scopus 로고
    • Should noninvasive ventilation be considered a high-risk procedure during an epidemic?
    • McCracken J. Should noninvasive ventilation be considered a high-risk procedure during an epidemic?. Can Med Assoc J 2009, 181:663-664.
    • (2009) Can Med Assoc J , vol.181 , pp. 663-664
    • McCracken, J.1
  • 54
    • 33644697163 scopus 로고    scopus 로고
    • Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems
    • Qian H., Li Y., Nielsen P.V., Hyldgaard C.E., Wong T.W., Chwang A.T. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems. Indoor Air 2006, 16:111-128.
    • (2006) Indoor Air , vol.16 , pp. 111-128
    • Qian, H.1    Li, Y.2    Nielsen, P.V.3    Hyldgaard, C.E.4    Wong, T.W.5    Chwang, A.T.6
  • 55
    • 73449145271 scopus 로고    scopus 로고
    • Control of airborne infectious diseases in ventilated spaces
    • Nielsen P.V. Control of airborne infectious diseases in ventilated spaces. J R Soc Interface 2009, 6(Suppl. 6):S747-S755.
    • (2009) J R Soc Interface , vol.6 , Issue.SUPPL. 6
    • Nielsen, P.V.1
  • 56
    • 73449138225 scopus 로고    scopus 로고
    • Personalized ventilation as a control measure for airborne transmissible disease spread
    • Pantelic J., Sze-To G.N., Tham K.W., Chao C.Y., Khoo Y.C. Personalized ventilation as a control measure for airborne transmissible disease spread. J R Soc Interface 2009, 6(Suppl. 6):S715-S726.
    • (2009) J R Soc Interface , vol.6 , Issue.SUPPL. 6
    • Pantelic, J.1    Sze-To, G.N.2    Tham, K.W.3    Chao, C.Y.4    Khoo, Y.C.5
  • 57
    • 0000582130 scopus 로고    scopus 로고
    • Personal exposure in displacement ventilated rooms
    • Brohus H., Nielsen P.V. Personal exposure in displacement ventilated rooms. Indoor Air 1996, 6:157-167.
    • (1996) Indoor Air , vol.6 , pp. 157-167
    • Brohus, H.1    Nielsen, P.V.2
  • 59
    • 0010213876 scopus 로고    scopus 로고
    • Dispersal of exhaled air and personal exposure in displacement ventilated rooms
    • Bjørn E., Nielsen P.V. Dispersal of exhaled air and personal exposure in displacement ventilated rooms. Indoor Air 2002, 12:147-164.
    • (2002) Indoor Air , vol.12 , pp. 147-164
    • Bjørn, E.1    Nielsen, P.V.2
  • 60
    • 73449123605 scopus 로고    scopus 로고
    • Contaminant flow in the microenvironment between people under different ventilation conditions
    • Nielsen P.V., Buus M., Winter F.V., Thilageswaran M. Contaminant flow in the microenvironment between people under different ventilation conditions. ASHRAE Trans 2008, 114:632-638.
    • (2008) ASHRAE Trans , vol.114 , pp. 632-638
    • Nielsen, P.V.1    Buus, M.2    Winter, F.V.3    Thilageswaran, M.4
  • 61
    • 79951856573 scopus 로고    scopus 로고
    • Cross infection in a hospital ward and deposition of particles exhaled from a source mannequin. In: 5th international workshop on energy and environment of residential buildings and 3rd international conference on build environment and public health, proceedings. Guilin, China
    • Nielsen PV, Li Y, Buus M, Winther FV, Qian H. Cross infection in a hospital ward and deposition of particles exhaled from a source mannequin. In: 5th international workshop on energy and environment of residential buildings and 3rd international conference on build environment and public health, proceedings. Guilin, China: 2009. 162-169.
    • (2009) , pp. 162-169
    • Nielsen, P.V.1    Li, Y.2    Buus, M.3    Winther, F.V.4    Qian, H.5
  • 62
    • 79951852086 scopus 로고    scopus 로고
    • Airflow and contaminant distribution in hospital wards with a displacement ventilation system
    • China Environmental Science Press, Beijing, X.S. Hou, J.L. Yand, L.W. Tian, C. Zheng (Eds.)
    • Qian H., Nielsen P.V., Li Y., Hyldgaard C.E. Airflow and contaminant distribution in hospital wards with a displacement ventilation system. Built environment and public health - Proceedings of BEPH 2004 2004, 355-364. China Environmental Science Press, Beijing. X.S. Hou, J.L. Yand, L.W. Tian, C. Zheng (Eds.).
    • (2004) Built environment and public health - Proceedings of BEPH 2004 , pp. 355-364
    • Qian, H.1    Nielsen, P.V.2    Li, Y.3    Hyldgaard, C.E.4
  • 63
    • 61749095805 scopus 로고    scopus 로고
    • Spatial distribution of infection risk of SARS transmission in a hospital ward
    • Qian H., Li Y., Nielsen P., Huang X. Spatial distribution of infection risk of SARS transmission in a hospital ward. Build Environ 2009, 44:1651-1658.
    • (2009) Build Environ , vol.44 , pp. 1651-1658
    • Qian, H.1    Li, Y.2    Nielsen, P.3    Huang, X.4
  • 64
    • 79951856346 scopus 로고    scopus 로고
    • Airborne cross-infection risk between two people in a displacement ventilated room. ASHRAE IAQ (in press)
    • Nielsen PV, Olmedo I, Ruiz de Adana M, Grzelecki P, Jensen RL. Airborne cross-infection risk between two people in a displacement ventilated room. ASHRAE IAQ (in press).
    • Nielsen, P.V.1    Olmedo, I.2    Ruiz de Adana, M.3    Grzelecki, P.4    Jensen, R.L.5
  • 65
    • 79951854592 scopus 로고    scopus 로고
    • The aircraft seat as indoor air quality and temperature control system
    • Tsinghua University Press, Beijing, Paper ID: I(1)-426, X.D. Yang, B. Zhao, R. Zhao (Eds.)
    • Jacobs P., de Gids W.F. The aircraft seat as indoor air quality and temperature control system. Proceedings of indoor air 2005 2005, Tsinghua University Press, Beijing, Paper ID: I(1)-426. X.D. Yang, B. Zhao, R. Zhao (Eds.).
    • (2005) Proceedings of indoor air 2005
    • Jacobs, P.1    de Gids, W.F.2
  • 66
    • 20844447341 scopus 로고    scopus 로고
    • Personalized ventilation
    • Melikov A. Personalized ventilation. Indoor Air 2004, 14(Suppl. 7):157-167.
    • (2004) Indoor Air , vol.14 , Issue.SUPPL. 7 , pp. 157-167
    • Melikov, A.1
  • 67
    • 34347214433 scopus 로고    scopus 로고
    • Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation
    • Nielsen P.V., Hyldgaard C.E., Melikov A., Andersen H., Soennichsen M. Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation. HVAC&R Res 2007, 13:635-643.
    • (2007) HVAC&R Res , vol.13 , pp. 635-643
    • Nielsen, P.V.1    Hyldgaard, C.E.2    Melikov, A.3    Andersen, H.4    Soennichsen, M.5
  • 68
    • 79951856249 scopus 로고    scopus 로고
    • Chair with integrated personalized ventilation for minimizing cross infection. In: Proceedings of the 10th international conference on air distribution in rooms. Roomvent 2007. Helsinki, Finland: Paper ID
    • Nielsen PV, Bartholomaeussen NM, Jakubowska E, et al. Chair with integrated personalized ventilation for minimizing cross infection. In: Proceedings of the 10th international conference on air distribution in rooms. Roomvent 2007. Helsinki, Finland: 2007. Paper ID: 1078.
    • (2007) , pp. 1078
    • Nielsen, P.V.1    Bartholomaeussen, N.M.2    Jakubowska, E.3
  • 69
    • 79951851178 scopus 로고    scopus 로고
    • The influence of draught on a seat with integrated personalized ventilation
    • Copenhagen, Denmark. Paper ID: P. Strøm-Tejsen, B.W. Olesen, P. Wargocki, D. Zukowska, J. Toftum (Eds.)
    • Nielsen P.V., Barszcz E., Czarnota T., et al. The influence of draught on a seat with integrated personalized ventilation. Indoor air 2008: proceedings of the 11th international conference on indoor air quality and climate 2008, Copenhagen, Denmark. Paper ID: 247. P. Strøm-Tejsen, B.W. Olesen, P. Wargocki, D. Zukowska, J. Toftum (Eds.).
    • (2008) Indoor air 2008: proceedings of the 11th international conference on indoor air quality and climate , pp. 247
    • Nielsen, P.V.1    Barszcz, E.2    Czarnota, T.3
  • 71
    • 84872655909 scopus 로고    scopus 로고
    • Performance of "ductless" personalized ventilation in conjunction with displacement ventilation: impact of walking occupant
    • Syracuse, NY, USA. Paper ID: 520, E.A. Bogucz (Ed.)
    • Halvonova B., Melikov A.K. Performance of "ductless" personalized ventilation in conjunction with displacement ventilation: impact of walking occupant. Proceedings of the healthy buildings 2009, 9th international conference and exhibition 2009, Syracuse, NY, USA. Paper ID: 520. E.A. Bogucz (Ed.).
    • (2009) Proceedings of the healthy buildings 2009, 9th international conference and exhibition
    • Halvonova, B.1    Melikov, A.K.2
  • 72
    • 77950318718 scopus 로고    scopus 로고
    • Mitigation of cross-contamination in an aircraft cabin via localized suction removal
    • Busan, South Korea, K.W. Kim, D.W. Yoon, M.S. Yeo, H.J. Moon, C.S. Park (Eds.)
    • Dygert R.K., Dang T.Q. Mitigation of cross-contamination in an aircraft cabin via localized suction removal. Proceedings of the 11th international conference on air distribution in rooms. Roomvent 2009 2009, 1675-1682. Busan, South Korea. K.W. Kim, D.W. Yoon, M.S. Yeo, H.J. Moon, C.S. Park (Eds.).
    • (2009) Proceedings of the 11th international conference on air distribution in rooms. Roomvent 2009 , pp. 1675-1682
    • Dygert, R.K.1    Dang, T.Q.2
  • 74
    • 73449147225 scopus 로고    scopus 로고
    • Protection against cross infection in hospital beds with integrated personalized ventilation
    • Copenhagen, Denmark. Paper ID: P. Strøm-Tejsen, B.W. Olesen, P. Wargocki, D. Zukowska, J. Toftum (Eds.)
    • Nielsen P.V., Polak M., Jiang H., Li Y., Qian H. Protection against cross infection in hospital beds with integrated personalized ventilation. Indoor air 2008: proceedings of the 11th international conference on indoor air quality and climate 2008, Copenhagen, Denmark. Paper ID: 244. P. Strøm-Tejsen, B.W. Olesen, P. Wargocki, D. Zukowska, J. Toftum (Eds.).
    • (2008) Indoor air 2008: proceedings of the 11th international conference on indoor air quality and climate , pp. 244
    • Nielsen, P.V.1    Polak, M.2    Jiang, H.3    Li, Y.4    Qian, H.5
  • 75
    • 7244248704 scopus 로고    scopus 로고
    • Visualizing full-scale ventilation airflows
    • Settles G.S. Visualizing full-scale ventilation airflows. ASHRAE J 1997, 39:19-26.
    • (1997) ASHRAE J , vol.39 , pp. 19-26
    • Settles, G.S.1
  • 77
    • 32644440499 scopus 로고    scopus 로고
    • Fluid mechanics and homeland security
    • Settles G.S. Fluid mechanics and homeland security. Annu Rev Fluid Mech 2006, 38:87-110.
    • (2006) Annu Rev Fluid Mech , vol.38 , pp. 87-110
    • Settles, G.S.1
  • 78
    • 33751404425 scopus 로고    scopus 로고
    • A computational and experimental investigation of the human thermal plume
    • Craven B.A., Settles G.S. A computational and experimental investigation of the human thermal plume. J Fluids Engng 2006, 128:1251-1258.
    • (2006) J Fluids Engng , vol.128 , pp. 1251-1258
    • Craven, B.A.1    Settles, G.S.2
  • 81
    • 73449110911 scopus 로고    scopus 로고
    • Some aspects of the airborne transmission of infection
    • Clark R.P., de Calcina-Goff M.L. Some aspects of the airborne transmission of infection. J R Soc Interface 2009, 6(Suppl. 6):S767-S782.
    • (2009) J R Soc Interface , vol.6 , Issue.SUPPL. 6
    • Clark, R.P.1    de Calcina-Goff, M.L.2
  • 82
    • 0016184328 scopus 로고
    • The effect of obstructions and thermals in laminar flow systems
    • Whyte W., Shaw B.H. The effect of obstructions and thermals in laminar flow systems. J Hyg 1974, 72:415-423.
    • (1974) J Hyg , vol.72 , pp. 415-423
    • Whyte, W.1    Shaw, B.H.2
  • 84
    • 29444455397 scopus 로고    scopus 로고
    • Door-opening motion can potentially lead to a transient breakdown in negative-pressure isolation conditions: the importance of vorticity and buoyancy airflows
    • Tang J.W., Eames I., Li Y., et al. Door-opening motion can potentially lead to a transient breakdown in negative-pressure isolation conditions: the importance of vorticity and buoyancy airflows. J Hosp Infect 2005, 61:283-286.
    • (2005) J Hosp Infect , vol.61 , pp. 283-286
    • Tang, J.W.1    Eames, I.2    Li, Y.3
  • 85
    • 15744393009 scopus 로고    scopus 로고
    • Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
    • Li Y., Huang X., Yu I.T.S., Wong T.W., Qian H. Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong. Indoor Air 2005, 152:83-95.
    • (2005) Indoor Air , vol.152 , pp. 83-95
    • Li, Y.1    Huang, X.2    Yu, I.T.S.3    Wong, T.W.4    Qian, H.5
  • 87
    • 33748304333 scopus 로고    scopus 로고
    • Influence of movements on contaminant transport in operating room
    • Brohus H., Balling K.D., Jeppesen D. Influence of movements on contaminant transport in operating room. Indoor Air 2006, 16:356-372.
    • (2006) Indoor Air , vol.16 , pp. 356-372
    • Brohus, H.1    Balling, K.D.2    Jeppesen, D.3
  • 88
    • 20844437768 scopus 로고    scopus 로고
    • Computational fluid dynamics and room air movement
    • Nielsen P.V. Computational fluid dynamics and room air movement. Indoor Air 2004, 14:134-143.
    • (2004) Indoor Air , vol.14 , pp. 134-143
    • Nielsen, P.V.1
  • 89
    • 1842787454 scopus 로고    scopus 로고
    • CFD study on micro-environment around human body and personalised ventilation
    • Gao N., Nui J. CFD study on micro-environment around human body and personalised ventilation. Build Environ 2004, 39:795-805.
    • (2004) Build Environ , vol.39 , pp. 795-805
    • Gao, N.1    Nui, J.2
  • 90
    • 33645950803 scopus 로고    scopus 로고
    • Transient CFD simulation of the respiration process and inter-person exposure assessment
    • Gao N., Niu J. Transient CFD simulation of the respiration process and inter-person exposure assessment. Build Environ 2006, 41:1214-1222.
    • (2006) Build Environ , vol.41 , pp. 1214-1222
    • Gao, N.1    Niu, J.2
  • 91
    • 84855622765 scopus 로고    scopus 로고
    • CFD modelling of a hospital ward: assessing risk from bacteria produced from respiratory and activity sources
    • Copenhagen, Denmark. Paper ID: P. Strøm-Tejsen, B.W. Olesen, P. Wargocki, D. Zukowska, J. Toftum (Eds.)
    • Hathway E.A., Noakes C.J., Sleigh P.A. CFD modelling of a hospital ward: assessing risk from bacteria produced from respiratory and activity sources. Indoor air 2008: proceedings of the 11th international conference on indoor air quality and climate 2008, Copenhagen, Denmark. Paper ID: 45. P. Strøm-Tejsen, B.W. Olesen, P. Wargocki, D. Zukowska, J. Toftum (Eds.).
    • (2008) Indoor air 2008: proceedings of the 11th international conference on indoor air quality and climate , pp. 45
    • Hathway, E.A.1    Noakes, C.J.2    Sleigh, P.A.3
  • 92
    • 33646182700 scopus 로고    scopus 로고
    • Experimental measurements and numerical simulations of particle transport and distribution in ventilated rooms
    • Zhang Z., Chen Q. Experimental measurements and numerical simulations of particle transport and distribution in ventilated rooms. Atmos Environ 2006, 40:3396-3408.
    • (2006) Atmos Environ , vol.40 , pp. 3396-3408
    • Zhang, Z.1    Chen, Q.2
  • 93
    • 36549032133 scopus 로고    scopus 로고
    • Particle dispersion and deposition in ventilated rooms: testing and evaluation of different Eulerian and Lagrangian models
    • Zhao B., Yang C., Yang X., Liu S. Particle dispersion and deposition in ventilated rooms: testing and evaluation of different Eulerian and Lagrangian models. Build Environ 2008, 43:388-397.
    • (2008) Build Environ , vol.43 , pp. 388-397
    • Zhao, B.1    Yang, C.2    Yang, X.3    Liu, S.4
  • 94
    • 0029731489 scopus 로고    scopus 로고
    • Numerical analysis of indoor aerosol particle deposition and distribution in two-zone ventilation system
    • Lu W., Howarth A.T. Numerical analysis of indoor aerosol particle deposition and distribution in two-zone ventilation system. Build Environ 1996, 31:41-50.
    • (1996) Build Environ , vol.31 , pp. 41-50
    • Lu, W.1    Howarth, A.T.2
  • 95
    • 1642619104 scopus 로고    scopus 로고
    • Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet light
    • Noakes C.J., Fletcher L.A., Beggs C.B., Sleigh P.A., Kerr K.G. Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet light. J Aerosol Sci 2004, 354:489-507.
    • (2004) J Aerosol Sci , vol.354 , pp. 489-507
    • Noakes, C.J.1    Fletcher, L.A.2    Beggs, C.B.3    Sleigh, P.A.4    Kerr, K.G.5
  • 96
    • 10844291720 scopus 로고    scopus 로고
    • Modelling the performance of upper room ultraviolet germicidal irradiation devices in ventilated rooms: comparison of analytical and CFD methods
    • Noakes C.J., Beggs C.B., Sleigh P.A. Modelling the performance of upper room ultraviolet germicidal irradiation devices in ventilated rooms: comparison of analytical and CFD methods. Indoor Built Environ 2004, 136:477-488.
    • (2004) Indoor Built Environ , vol.136 , pp. 477-488
    • Noakes, C.J.1    Beggs, C.B.2    Sleigh, P.A.3
  • 97
    • 33847142204 scopus 로고    scopus 로고
    • Dispersion of expiratory droplets in a general hospital ward with ceiling mixing type mechanical ventilation system
    • Wan M.P., Chao C.Y.H., Ng Y.D., Sze To G.N., Yu W.C. Dispersion of expiratory droplets in a general hospital ward with ceiling mixing type mechanical ventilation system. Aerosol Sci Tech 2007, 413:244-258.
    • (2007) Aerosol Sci Tech , vol.413 , pp. 244-258
    • Wan, M.P.1    Chao, C.Y.H.2    Ng, Y.D.3    Sze To, G.N.4    Yu, W.C.5
  • 98
    • 34247104913 scopus 로고    scopus 로고
    • Dynamic airflow simulation within an isolation room
    • Shih Y.-C., Chiu C.-C., Wang O. Dynamic airflow simulation within an isolation room. Build Environ 2007, 429:3194-3209.
    • (2007) Build Environ , vol.429 , pp. 3194-3209
    • Shih, Y.-C.1    Chiu, C.-C.2    Wang, O.3
  • 99
    • 0142025103 scopus 로고    scopus 로고
    • Performance of ventilation system in a non-standard operating room
    • Chow T.T., Yang X.Y. Performance of ventilation system in a non-standard operating room. Build Environ 2003, 38:1401-1411.
    • (2003) Build Environ , vol.38 , pp. 1401-1411
    • Chow, T.T.1    Yang, X.Y.2
  • 101
    • 73449091143 scopus 로고    scopus 로고
    • Movement of airborne contaminants in an isolation room
    • Eames I., Shoaib D., Klettner C., Taban V. Movement of airborne contaminants in an isolation room. J R Soc Interface 2009, 6:757-766.
    • (2009) J R Soc Interface , vol.6 , pp. 757-766
    • Eames, I.1    Shoaib, D.2    Klettner, C.3    Taban, V.4
  • 102
    • 0014482147 scopus 로고
    • Protection from microbial contamination in a room ventilated by a uni-directional air flow
    • Lidwell O.M., Towers A.G. Protection from microbial contamination in a room ventilated by a uni-directional air flow. J Hyg 1969, 67. p. 95-106.
    • (1969) J Hyg , vol.67 , pp. 95-106
    • Lidwell, O.M.1    Towers, A.G.2
  • 103
    • 0021088295 scopus 로고
    • A comparison between tracer gas and tracer particle techniques in evaluating the efficiency of ventilation in operating theatres
    • Andersson P.A., Hambraeus A., Zettersten U., Ljungqvist B., Neikter K., Ransjö U. A comparison between tracer gas and tracer particle techniques in evaluating the efficiency of ventilation in operating theatres. J Hyg 1983, 91:509-519.
    • (1983) J Hyg , vol.91 , pp. 509-519
    • Andersson, P.A.1    Hambraeus, A.2    Zettersten, U.3    Ljungqvist, B.4    Neikter, K.5    Ransjö, U.6
  • 104
    • 0016159928 scopus 로고
    • An evaluation of a partial-walled laminar-flow operating room
    • Whyte W., Shaw B.H., Freeman M.A.R. An evaluation of a partial-walled laminar-flow operating room. J Hyg 1974, 73:61-76.
    • (1974) J Hyg , vol.73 , pp. 61-76
    • Whyte, W.1    Shaw, B.H.2    Freeman, M.A.R.3
  • 106
    • 33745698432 scopus 로고    scopus 로고
    • A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach
    • Chao C.Y.H., Wan M.P. A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach. Indoor Air 2006, 16:296-312.
    • (2006) Indoor Air , vol.16 , pp. 296-312
    • Chao, C.Y.H.1    Wan, M.P.2
  • 107
    • 0041949578 scopus 로고
    • The evaluation of ventilation
    • Lidwell O.M. The evaluation of ventilation. J Hyg 1960, 58:297-305.
    • (1960) J Hyg , vol.58 , pp. 297-305
    • Lidwell, O.M.1
  • 108
    • 33847666937 scopus 로고    scopus 로고
    • Natural ventilation for the prevention of airborne contagion
    • Escombe A.R., Oeser C.C., Gilman R.H., et al. Natural ventilation for the prevention of airborne contagion. PLoS Medicine 2007, 4:e68.
    • (2007) PLoS Medicine , vol.4
    • Escombe, A.R.1    Oeser, C.C.2    Gilman, R.H.3
  • 110
    • 3242772215 scopus 로고    scopus 로고
    • Containment testing of isolation rooms
    • Rydock J.P., Eian P.K. Containment testing of isolation rooms. J Hosp Infect 2004, 57:228-232.
    • (2004) J Hosp Infect , vol.57 , pp. 228-232
    • Rydock, J.P.1    Eian, P.K.2
  • 111
    • 0347873834 scopus 로고
    • The ventilation of operating theatres
    • Lidwell O.M., Williams R.E.O. The ventilation of operating theatres. J Hyg 1960, 58:449.
    • (1960) J Hyg , vol.58 , pp. 449
    • Lidwell, O.M.1    Williams, R.E.O.2
  • 112
    • 0015350070 scopus 로고
    • The control by ventilation of bacterial transfer between hospital patients and its assessment by means of a particle tracer. I. An airborne particle tracer for cross infection studies
    • Foord N., Lidwell O.M. The control by ventilation of bacterial transfer between hospital patients and its assessment by means of a particle tracer. I. An airborne particle tracer for cross infection studies. J Hyg 1972, 70:279-287.
    • (1972) J Hyg , vol.70 , pp. 279-287
    • Foord, N.1    Lidwell, O.M.2
  • 113
    • 0015350070 scopus 로고
    • The control by ventilation of bacterial transfer between hospital patients and its assessment by means of a particle tracer. II. Ventilation in subdivided isolation units
    • Lidwell O.M. The control by ventilation of bacterial transfer between hospital patients and its assessment by means of a particle tracer. II. Ventilation in subdivided isolation units. J Hyg 1972, 70:279-287.
    • (1972) J Hyg , vol.70 , pp. 279-287
    • Lidwell, O.M.1
  • 114
    • 0015352277 scopus 로고
    • The control by ventilation of bacterial transfer between hospital patients and its assessment by means of a particle tracer. III. Studies with an airborne-particle tracer in an isolation ward for burned patients
    • Hambraeus A., Sanderson H.F. The control by ventilation of bacterial transfer between hospital patients and its assessment by means of a particle tracer. III. Studies with an airborne-particle tracer in an isolation ward for burned patients. J Hyg 1972, 70:299-312.
    • (1972) J Hyg , vol.70 , pp. 299-312
    • Hambraeus, A.1    Sanderson, H.F.2
  • 115
    • 79951855119 scopus 로고
    • Application of the microaerofluorometer to the study of dispersion of a fluorescent aerosol into a selected atmosphere
    • Goldberg L.J. Application of the microaerofluorometer to the study of dispersion of a fluorescent aerosol into a selected atmosphere. J Appl Meteorol 1968, 7:68-72.
    • (1968) J Appl Meteorol , vol.7 , pp. 68-72
    • Goldberg, L.J.1
  • 116
    • 33846261947 scopus 로고    scopus 로고
    • Control of aerosol contaminants in indoor air: combining the particle concentration reduction with microbial inactivation
    • Grinshpun S.A., Adhikari A., Honda T., et al. Control of aerosol contaminants in indoor air: combining the particle concentration reduction with microbial inactivation. Environ Sci Tech 2007, 41:606-612.
    • (2007) Environ Sci Tech , vol.41 , pp. 606-612
    • Grinshpun, S.A.1    Adhikari, A.2    Honda, T.3
  • 118
    • 40349092809 scopus 로고    scopus 로고
    • An efficient analytical method for particle counting in evaluating airborne infectious isolation containment using fluorescent microspheres
    • Johnson D.L., Lynch R.A. An efficient analytical method for particle counting in evaluating airborne infectious isolation containment using fluorescent microspheres. J. Occup Environ Hyg 2008, 5:271-277.
    • (2008) J. Occup Environ Hyg , vol.5 , pp. 271-277
    • Johnson, D.L.1    Lynch, R.A.2
  • 119
    • 0015011769 scopus 로고
    • Convection, air mixing and ultraviolet air disinfection in rooms
    • Riley R.L., Permutt S., Kaufman J.E. Convection, air mixing and ultraviolet air disinfection in rooms. Arch Environ Health 1971, 22:200-207.
    • (1971) Arch Environ Health , vol.22 , pp. 200-207
    • Riley, R.L.1    Permutt, S.2    Kaufman, J.E.3
  • 121
    • 0022358183 scopus 로고
    • Ventilation conditions and air-borne bacteria and particles in operating theatres: proposed safe economies
    • Clark R.P., Reed P.J., Seal D.V., Stephenson M.L. Ventilation conditions and air-borne bacteria and particles in operating theatres: proposed safe economies. J Hyg 1985, 95:325-335.
    • (1985) J Hyg , vol.95 , pp. 325-335
    • Clark, R.P.1    Reed, P.J.2    Seal, D.V.3    Stephenson, M.L.4
  • 123
    • 39549118889 scopus 로고    scopus 로고
    • Aerial dissemination of Clostridium difficile spores
    • Roberts K., Smith C.F., Snelling A.M., et al. Aerial dissemination of Clostridium difficile spores. BMC Infect Dis 2008, 8:7.
    • (2008) BMC Infect Dis , vol.8 , pp. 7
    • Roberts, K.1    Smith, C.F.2    Snelling, A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.