메뉴 건너뛰기




Volumn 24, Issue 1, 2011, Pages 43-50

Adapted random sampling patterns for accelerated MRI

Author keywords

Accelerated imaging; Parallel imaging; Random sampling; Variable density sampling

Indexed keywords

ARTICLE; AUTOMATED PATTERN RECOGNITION; COMPUTER ASSISTED DIAGNOSIS; EVALUATION; HUMAN; INSTRUMENTATION; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PROBABILITY; REFERENCE VALUE; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; STATISTICAL ANALYSIS;

EID: 79951811416     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-010-0234-7     Document Type: Article
Times cited : (83)

References (13)
  • 1
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S
    • KP Pruessmann M Weiger MB Scheidegger P Boesiger 1999 SENSE: sensitivity encoding for fast MRI Magn Reson Med 42 5 952 962 1:STN:280: DC%2BD3c%2FhtFCruw%3D%3D 10.1002/(SICI)1522-2594(199911)42:5<952::AID- MRM16>3.0.CO;2-S 10542355 (Pubitemid 29521486)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.5 , pp. 952-962
    • Pruessmann, K.P.1    Weiger, M.2    Scheidegger, M.B.3    Boesiger, P.4
  • 3
    • 0027450251 scopus 로고
    • Consistent projection reconstruction (CPR) techniques for MRI
    • GH Glover DC Noll 1993 Consistent projection reconstruction (CPR) techniques for MRI Magn Reson Med 29 3 345 351 1:STN:280:DyaK3s7ps1Cltw%3D%3D 10.1002/mrm.1910290310 8450743 (Pubitemid 23114500)
    • (1993) Magnetic Resonance in Medicine , vol.29 , Issue.3 , pp. 345-351
    • Glover, G.H.1    Noll, D.C.2
  • 4
    • 0344737801 scopus 로고    scopus 로고
    • Fast 3D Imaging Using Variable-Density Spiral Trajectories with Applications to Limb Perfusion
    • DOI 10.1002/mrm.10644
    • JH Lee BA Hargreaves BS Hu DG Nishimura 2003 Fast 3d imaging using variable-density spiral trajectories with applications to limb perfusion Magn Reson Med 50 6 1276 1285 10.1002/mrm.10644 14648576 (Pubitemid 37494029)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.6 , pp. 1276-1285
    • Lee, J.H.1    Hargreaves, B.A.2    Hu, B.S.3    Nishimura, D.G.4
  • 7
    • 0034007629 scopus 로고    scopus 로고
    • Reduced aliasing artifacts using variable-density k-space sampling trajectories
    • DOI 10.1002/(SICI)1522-2594(200003)43:3<452::AID-MRM18>3.0.CO;2-B
    • CM Tsai DG Nishimura 2000 Reduced aliasing artifacts using variable-density k-space sampling trajectories Magn Reson Med 43 3 452 458 1:STN:280:DC%2BD3c3gtFCgsw%3D%3D 10.1002/(SICI)1522-2594(200003)43:3<452:: AID-MRM18>3.0.CO;2-B 10725889 (Pubitemid 30127533)
    • (2000) Magnetic Resonance in Medicine , vol.43 , Issue.3 , pp. 452-458
    • Tsai, C.-M.1    Nishimura, D.G.2
  • 8
    • 0344737798 scopus 로고    scopus 로고
    • Efficient k-Space Sampling by Density-Weighted Phase-Encoding
    • DOI 10.1002/mrm.10647
    • A Greiser M von Kienlin 2003 Efficient k-space sampling by density-weighted phase-encoding Magn Reson Med 50 6 1266 1275 10.1002/mrm.10647 14648575 (Pubitemid 37494028)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.6 , pp. 1266-1275
    • Greiser, A.1    Von Kienlin, M.2
  • 9
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • DOI 10.1002/mrm.21391
    • M Lustig D Donoho JM Pauly 2007 Sparse MRI: the application of compressed sensing for rapid MR imaging Magn Reson Med 58 6 1182 1195 10.1002/mrm.21391 17969013 (Pubitemid 350234205)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 10
    • 85032751466 scopus 로고    scopus 로고
    • Compressed sensing MRI: A look at how CS can improve on current imaging techniques
    • DOI 10.1109/MSP.2007.914728
    • M Lustig DL Donoho JM Santos JM Pauly 2008 Compressed sensing MRI IEEE Signal Process Mag 25 2 72 82 10.1109/MSP.2007.914728 (Pubitemid 351513068)
    • (2008) IEEE Signal Processing Magazine , vol.25 , Issue.2 , pp. 72-82
    • Lustig, M.1    Donoho, D.L.2    Santos, J.M.3    Pauly, J.M.4
  • 12
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • DOI 10.1002/mrm.21236
    • KT Block M Uecker J Frahm 2007 Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint Magn Reson Med 57 1086 1098 10.1002/mrm.21236 17534903 (Pubitemid 46911293)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.6 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 13
    • 77955102061 scopus 로고    scopus 로고
    • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space
    • 20665790
    • M Lustig JM Pauly 2010 SPIRiT: iterative self-consistent parallel imaging reconstruction from arbitrary k-space Magn Reson Med 64 457 471 20665790
    • (2010) Magn Reson Med , vol.64 , pp. 457-471
    • Lustig, M.1    Pauly, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.