메뉴 건너뛰기




Volumn 24, Issue 1, 2011, Pages 65-71

Do Clinical Outcomes in Chronic Hemodialysis Depend on the Choice of a Dialyzer?

Author keywords

[No Author keywords available]

Indexed keywords

DIALYSIS FLUID;

EID: 79951796348     PISSN: 08940959     EISSN: 1525139X     Source Type: Journal    
DOI: 10.1111/j.1525-139X.2010.00807.x     Document Type: Article
Times cited : (21)

References (54)
  • 1
    • 0027254912 scopus 로고
    • Clinical implications of hemodialysis membrane biocompatibility
    • Hakim RM: Clinical implications of hemodialysis membrane biocompatibility. Kidney Int 44:484-494, 1993
    • (1993) Kidney Int , vol.44 , pp. 484-494
    • Hakim, R.M.1
  • 2
    • 79951782228 scopus 로고    scopus 로고
    • Replacement of Renal Function by Dialysis
    • In: Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF (eds)., 5th ed. Dordrecht: Kluwer Academic, -
    • Ronco C, Ghezzi PM, Bowry SK: Membranes for hemodialysis. In: Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF (eds). Replacement of Renal Function by Dialysis, 5th ed. Dordrecht: Kluwer Academic, 2004: 301-323
    • (2004) Membranes for hemodialysis , pp. 301-323
    • Ronco, C.1    Ghezzi, P.M.2    Bowry, S.K.3
  • 3
    • 0028296181 scopus 로고
    • Phagocytic cell function as an index of biocompatibility
    • Ward RA: Phagocytic cell function as an index of biocompatibility. Nephrol Dial Transplant 9(Suppl 2):46-56, 1994
    • (1994) Nephrol Dial Transplant , vol.9 , Issue.SUPPL. 2 , pp. 46-56
    • Ward, R.A.1
  • 6
    • 0035703897 scopus 로고    scopus 로고
    • Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis
    • Lonnemann G, Sereni L, Lemke H-D, Tetta C: Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis. Artif Organs 25:951-960, 2001
    • (2001) Artif Organs , vol.25 , pp. 951-960
    • Lonnemann, G.1    Sereni, L.2    Lemke, H.-D.3    Tetta, C.4
  • 7
    • 0023121476 scopus 로고
    • Ethylene oxide in dialyzer rinsing fluid: effect of rinsing technique, dialyzer storage time, and potting compound
    • Ansorge W, Pelger M, Dietrich W, Baurmeister U: Ethylene oxide in dialyzer rinsing fluid: effect of rinsing technique, dialyzer storage time, and potting compound. Artif Organs 11:118-122, 1987
    • (1987) Artif Organs , vol.11 , pp. 118-122
    • Ansorge, W.1    Pelger, M.2    Dietrich, W.3    Baurmeister, U.4
  • 9
    • 0013990616 scopus 로고
    • Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices
    • Michaels AS: Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices. Trans Am Soc Artif Intern Organs 12:387-392, 1966
    • (1966) Trans Am Soc Artif Intern Organs , vol.12 , pp. 387-392
    • Michaels, A.S.1
  • 12
    • 77949542077 scopus 로고    scopus 로고
    • Haemodiafiltration - optimal efficiency and safety
    • Ledebo I, Blankestijn PJ: Haemodiafiltration - optimal efficiency and safety. NDT Plus 3:8-16, 2010
    • (2010) NDT Plus , vol.3 , pp. 8-16
    • Ledebo, I.1    Blankestijn, P.J.2
  • 13
    • 0031708390 scopus 로고    scopus 로고
    • Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer
    • Ronco C, Orlandini G, Brendolan A, Lupi A, La Greca G: Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer. Kidney Int 54:979-985, 1998
    • (1998) Kidney Int , vol.54 , pp. 979-985
    • Ronco, C.1    Orlandini, G.2    Brendolan, A.3    Lupi, A.4    La Greca, G.5
  • 15
    • 0033868074 scopus 로고    scopus 로고
    • Effects of a reduced inner diameter of hollow fibers in hemodialyzers
    • Ronco C, Brendolan A, Lupi A, Metry G, Levin NW: Effects of a reduced inner diameter of hollow fibers in hemodialyzers. Kidney Int 58:809-817, 2000
    • (2000) Kidney Int , vol.58 , pp. 809-817
    • Ronco, C.1    Brendolan, A.2    Lupi, A.3    Metry, G.4    Levin, N.W.5
  • 17
    • 44449097568 scopus 로고    scopus 로고
    • Differences in solute removal by two high-flux membranes of nominally similar synthetic polymers
    • Ouseph R, Hutchison CA, Ward RA: Differences in solute removal by two high-flux membranes of nominally similar synthetic polymers. Nephrol Dial Transplant 23:1704-1712, 2008
    • (2008) Nephrol Dial Transplant , vol.23 , pp. 1704-1712
    • Ouseph, R.1    Hutchison, C.A.2    Ward, R.A.3
  • 18
    • 0027033440 scopus 로고
    • A multivariate analysis of mortality and hospital admissions with high-flux dialysis
    • Hornberger JC, Chernew M, Petersen J, Garber AM: A multivariate analysis of mortality and hospital admissions with high-flux dialysis. J Am Soc Nephrol 3:1227-1237, 1992
    • (1992) J Am Soc Nephrol , vol.3 , pp. 1227-1237
    • Hornberger, J.C.1    Chernew, M.2    Petersen, J.3    Garber, A.M.4
  • 22
    • 46049109167 scopus 로고    scopus 로고
    • Biocompatibility and permeability of dialyzer membranes do not affect anemia, erythropoietin dosage or mortality in Japanese patients on chronic non-reuse hemodialysis: a prospective cohort study form the J-DOPPS II study
    • Yokoyama H, Kawaguchi T, Wada T, Takahashi Y, Higashi T, Yamazaki S, Fukuhara S, Akiba T, Akizawa T, Asano Y, Kurokawa K, Saito A: Biocompatibility and permeability of dialyzer membranes do not affect anemia, erythropoietin dosage or mortality in Japanese patients on chronic non-reuse hemodialysis: a prospective cohort study form the J-DOPPS II study. Nephron Clin Pract 109:c100-c108, 2008
    • (2008) Nephron Clin Pract , vol.109
    • Yokoyama, H.1    Kawaguchi, T.2    Wada, T.3    Takahashi, Y.4    Higashi, T.5    Yamazaki, S.6    Fukuhara, S.7    Akiba, T.8    Akizawa, T.9    Asano, Y.10    Kurokawa, K.11    Saito, A.12
  • 23
    • 10244255046 scopus 로고    scopus 로고
    • Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters
    • Locatelli F, Mastrangelo F, Redaelli B, Ronco C, Marcelli D, La Greca G, Orlandini G: Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters. Kidney Int 50:1293-1302, 1996
    • (1996) Kidney Int , vol.50 , pp. 1293-1302
    • Locatelli, F.1    Mastrangelo, F.2    Redaelli, B.3    Ronco, C.4    Marcelli, D.5    La Greca, G.6    Orlandini, G.7
  • 24
    • 33846638745 scopus 로고    scopus 로고
    • Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis
    • Krane V, Krieter DH, Olschewski M, März W, Mann JFE, Ritz E, Wanner C: Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis. Am J Kidney Dis 49:267-275, 2007
    • (2007) Am J Kidney Dis , vol.49 , pp. 267-275
    • Krane, V.1    Krieter, D.H.2    Olschewski, M.3    März, W.4    Mann, J.F.E.5    Ritz, E.6    Wanner, C.7
  • 25
    • 0026099093 scopus 로고
    • Phagocytosis in uremic and hemodialysis patients: a prospective and cross sectional study
    • Vanholder R, Ringoir S, Dhondt A, Hakim R: Phagocytosis in uremic and hemodialysis patients: a prospective and cross sectional study. Kidney Int 39:320-327, 1991
    • (1991) Kidney Int , vol.39 , pp. 320-327
    • Vanholder, R.1    Ringoir, S.2    Dhondt, A.3    Hakim, R.4
  • 26
    • 0030058767 scopus 로고    scopus 로고
    • Effect of the membrane biocompatibility on nutritional parameters in chronic hemodialysis patients
    • Parker TF, Wingard RL, Husni L, Ikizler TA, Parker RA, Hakim RM: Effect of the membrane biocompatibility on nutritional parameters in chronic hemodialysis patients. Kidney Int 49:551-556, 1996
    • (1996) Kidney Int , vol.49 , pp. 551-556
    • Parker, T.F.1    Wingard, R.L.2    Husni, L.3    Ikizler, T.A.4    Parker, R.A.5    Hakim, R.M.6
  • 27
    • 0026077307 scopus 로고
    • Acute intradialytic well-being: results of a clinical trial comparing polysulfone with cuprophan
    • Bergamo Collaborative Dialysis Study Group.
    • Bergamo Collaborative Dialysis Study Group: Acute intradialytic well-being: results of a clinical trial comparing polysulfone with cuprophan. Kidney Int 40:714-719, 1991
    • (1991) Kidney Int , vol.40 , pp. 714-719
  • 30
    • 0025286541 scopus 로고
    • Hypersensitivity reactions during haemodialysis: role of complement fragments and ethylene oxide antibodies
    • Lemke HD, Heidland A, Schaefer RM: Hypersensitivity reactions during haemodialysis: role of complement fragments and ethylene oxide antibodies. Nephrol Dial Transplant 5:264-269, 1990
    • (1990) Nephrol Dial Transplant , vol.5 , pp. 264-269
    • Lemke, H.D.1    Heidland, A.2    Schaefer, R.M.3
  • 32
    • 38349019673 scopus 로고    scopus 로고
    • The effect of electronegativity and angiotensin-converting enzyme inhibition on the kinin-forming capacity of polyacrylonitrile dialysis membranes
    • Désormeaux A, Moreau ME, Lepage Y, Chanard J, Adam A: The effect of electronegativity and angiotensin-converting enzyme inhibition on the kinin-forming capacity of polyacrylonitrile dialysis membranes. Biomaterials 29:1139-1146, 2008
    • (2008) Biomaterials , vol.29 , pp. 1139-1146
    • Désormeaux, A.1    Moreau, M.E.2    Lepage, Y.3    Chanard, J.4    Adam, A.5
  • 33
    • 44449151756 scopus 로고    scopus 로고
    • Delayed near-fatal anaphylactic reaction induced by the F10-HPS polysulfone haemodialyser
    • Huang W-H, Lee Y-Y, Shih L-C: Delayed near-fatal anaphylactic reaction induced by the F10-HPS polysulfone haemodialyser. Nephrol Dial Transplant 23:423-424, 2008
    • (2008) Nephrol Dial Transplant , vol.23 , pp. 423-424
    • Huang, W.-H.1    Lee, Y.-Y.2    Shih, L.-C.3
  • 34
    • 77952554373 scopus 로고    scopus 로고
    • Thrombocytopenia associated with use of a biocompatible hemodialysis membrane: a case report
    • Post JB: Thrombocytopenia associated with use of a biocompatible hemodialysis membrane: a case report. Am J Kidney Dis 55:e25-e28, 2010
    • (2010) Am J Kidney Dis , vol.55
    • Post, J.B.1
  • 35
    • 0019783774 scopus 로고
    • Effect of the hemodialysis prescription on patient morbidity. Report from the National Cooperative Dialysis Study
    • Lowrie EG, Laird NM, Parker TF, Sargent JA: Effect of the hemodialysis prescription on patient morbidity. Report from the National Cooperative Dialysis Study. N Engl J Med 305:1176-1181, 1981
    • (1981) N Engl J Med , vol.305 , pp. 1176-1181
    • Lowrie, E.G.1    Laird, N.M.2    Parker, T.F.3    Sargent, J.A.4
  • 36
    • 0021783946 scopus 로고
    • A mechanistic analysis of the National Cooperative Dialysis Study (NCDS)
    • Gotch FA, Sargent JA: A mechanistic analysis of the National Cooperative Dialysis Study (NCDS). Kidney Int 28:526-534, 1985
    • (1985) Kidney Int , vol.28 , pp. 526-534
    • Gotch, F.A.1    Sargent, J.A.2
  • 37
    • 0036208604 scopus 로고    scopus 로고
    • Dialysis dose and body mass index are strongly associated with survival in hemodialysis patients
    • Port FK, Ashby VB, Dhingra RK, Roys EC, Wolfe RA: Dialysis dose and body mass index are strongly associated with survival in hemodialysis patients. J Am Soc Nephrol 13:1061-1066, 2002
    • (2002) J Am Soc Nephrol , vol.13 , pp. 1061-1066
    • Port, F.K.1    Ashby, V.B.2    Dhingra, R.K.3    Roys, E.C.4    Wolfe, R.A.5
  • 38
    • 21644465205 scopus 로고    scopus 로고
    • Measurement of dialyzer clearance, dialysis time, and body size: death risk relationship among patients
    • Lowrie EG, Li Z, Ofsthun N, Lazarus JM: Measurement of dialyzer clearance, dialysis time, and body size: death risk relationship among patients. Kidney Int 66:2077-2084, 2004
    • (2004) Kidney Int , vol.66 , pp. 2077-2084
    • Lowrie, E.G.1    Li, Z.2    Ofsthun, N.3    Lazarus, J.M.4
  • 39
    • 33745285983 scopus 로고    scopus 로고
    • Clinical practice guidelines for hemodialysis adequacy, update 2006
    • Hemodialysis Adequacy 2006 Work Group.
    • Hemodialysis Adequacy 2006 Work Group: Clinical practice guidelines for hemodialysis adequacy, update 2006. Am J Kidney Dis 48(Suppl 1):S2-S90, 2006
    • (2006) Am J Kidney Dis , vol.48 , Issue.SUPPL. 1
  • 41
    • 77957291655 scopus 로고    scopus 로고
    • Can rescaling dose of dialysis to body surface area in the HEMO Study explain the different responses to dose in women versus men?
    • Daugirdas JT, Greene T, Chertow GM, Depner TA: Can rescaling dose of dialysis to body surface area in the HEMO Study explain the different responses to dose in women versus men? Clin J Am Soc Nephrol 5:1628-1636, 2010
    • (2010) Clin J Am Soc Nephrol , vol.5 , pp. 1628-1636
    • Daugirdas, J.T.1    Greene, T.2    Chertow, G.M.3    Depner, T.A.4
  • 44
    • 0033999037 scopus 로고    scopus 로고
    • Improved outcome for haemodialysis patients treated with high-flux membranes
    • Woods HF, Nandakumar M: Improved outcome for haemodialysis patients treated with high-flux membranes. Nephrol Dial Transplant 15(Suppl 1):36-42, 2000
    • (2000) Nephrol Dial Transplant , vol.15 , Issue.SUPPL. 1 , pp. 36-42
    • Woods, H.F.1    Nandakumar, M.2
  • 53
    • 77949541564 scopus 로고    scopus 로고
    • Hemodiafiltration: clinical evidence and remaining questions
    • Blankestijn PJ, Ledebo I, Canaud B: Hemodiafiltration: clinical evidence and remaining questions. Kidney Int 77:581-587, 2010
    • (2010) Kidney Int , vol.77 , pp. 581-587
    • Blankestijn, P.J.1    Ledebo, I.2    Canaud, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.