-
1
-
-
0027254912
-
Clinical implications of hemodialysis membrane biocompatibility
-
Hakim RM: Clinical implications of hemodialysis membrane biocompatibility. Kidney Int 44:484-494, 1993
-
(1993)
Kidney Int
, vol.44
, pp. 484-494
-
-
Hakim, R.M.1
-
2
-
-
79951782228
-
Replacement of Renal Function by Dialysis
-
In: Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF (eds)., 5th ed. Dordrecht: Kluwer Academic, -
-
Ronco C, Ghezzi PM, Bowry SK: Membranes for hemodialysis. In: Hörl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF (eds). Replacement of Renal Function by Dialysis, 5th ed. Dordrecht: Kluwer Academic, 2004: 301-323
-
(2004)
Membranes for hemodialysis
, pp. 301-323
-
-
Ronco, C.1
Ghezzi, P.M.2
Bowry, S.K.3
-
3
-
-
0028296181
-
Phagocytic cell function as an index of biocompatibility
-
Ward RA: Phagocytic cell function as an index of biocompatibility. Nephrol Dial Transplant 9(Suppl 2):46-56, 1994
-
(1994)
Nephrol Dial Transplant
, vol.9
, Issue.SUPPL. 2
, pp. 46-56
-
-
Ward, R.A.1
-
4
-
-
0026717781
-
Permeability of dialyzer membranes to TNFα-inducing substances derived from water bacteria
-
Lonnemann G, Behme TC, Lenzner B, Floege J, Schulze M, Colton CK, Koch KM, Shaldon S: Permeability of dialyzer membranes to TNFα-inducing substances derived from water bacteria. Kidney Int 42:61-68, 1992
-
(1992)
Kidney Int
, vol.42
, pp. 61-68
-
-
Lonnemann, G.1
Behme, T.C.2
Lenzner, B.3
Floege, J.4
Schulze, M.5
Colton, C.K.6
Koch, K.M.7
Shaldon, S.8
-
5
-
-
9644294204
-
Short bacterial DNA fragments: detection in dialysate and induction of cytokines
-
Schindler R, Beck W, Deppisch R, Aussieker M, Wilde A, Göhl H, Frei U: Short bacterial DNA fragments: detection in dialysate and induction of cytokines. J Am Soc Nephrol 15:3207-3214, 2004
-
(2004)
J Am Soc Nephrol
, vol.15
, pp. 3207-3214
-
-
Schindler, R.1
Beck, W.2
Deppisch, R.3
Aussieker, M.4
Wilde, A.5
Göhl, H.6
Frei, U.7
-
6
-
-
0035703897
-
Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis
-
Lonnemann G, Sereni L, Lemke H-D, Tetta C: Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis. Artif Organs 25:951-960, 2001
-
(2001)
Artif Organs
, vol.25
, pp. 951-960
-
-
Lonnemann, G.1
Sereni, L.2
Lemke, H.-D.3
Tetta, C.4
-
7
-
-
0023121476
-
Ethylene oxide in dialyzer rinsing fluid: effect of rinsing technique, dialyzer storage time, and potting compound
-
Ansorge W, Pelger M, Dietrich W, Baurmeister U: Ethylene oxide in dialyzer rinsing fluid: effect of rinsing technique, dialyzer storage time, and potting compound. Artif Organs 11:118-122, 1987
-
(1987)
Artif Organs
, vol.11
, pp. 118-122
-
-
Ansorge, W.1
Pelger, M.2
Dietrich, W.3
Baurmeister, U.4
-
9
-
-
0013990616
-
Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices
-
Michaels AS: Operating parameters and performance criteria for hemodialyzers and other membrane-separation devices. Trans Am Soc Artif Intern Organs 12:387-392, 1966
-
(1966)
Trans Am Soc Artif Intern Organs
, vol.12
, pp. 387-392
-
-
Michaels, A.S.1
-
11
-
-
0037137562
-
Effect of dialysis dose and membrane flux in maintenance hemodialysis
-
Eknoyan G, Beck GJ, Cheung AK, Daugirdas JT, Greene T, Kusek JW, Allon M, Bailey J, Delmez JA, Depner TA, Dwyer JT, Levey AS, Levin NW, Milford E, Ornt DB, Rocco MV, Schulman G, Schwab SJ, Teehan BP, Toto R: Effect of dialysis dose and membrane flux in maintenance hemodialysis. N Engl J Med 347:2010-2019, 2002
-
(2002)
N Engl J Med
, vol.347
, pp. 2010-2019
-
-
Eknoyan, G.1
Beck, G.J.2
Cheung, A.K.3
Daugirdas, J.T.4
Greene, T.5
Kusek, J.W.6
Allon, M.7
Bailey, J.8
Delmez, J.A.9
Depner, T.A.10
Dwyer, J.T.11
Levey, A.S.12
Levin, N.W.13
Milford, E.14
Ornt, D.B.15
Rocco, M.V.16
Schulman, G.17
Schwab, S.J.18
Teehan, B.P.19
Toto, R.20
more..
-
12
-
-
77949542077
-
Haemodiafiltration - optimal efficiency and safety
-
Ledebo I, Blankestijn PJ: Haemodiafiltration - optimal efficiency and safety. NDT Plus 3:8-16, 2010
-
(2010)
NDT Plus
, vol.3
, pp. 8-16
-
-
Ledebo, I.1
Blankestijn, P.J.2
-
13
-
-
0031708390
-
Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer
-
Ronco C, Orlandini G, Brendolan A, Lupi A, La Greca G: Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer. Kidney Int 54:979-985, 1998
-
(1998)
Kidney Int
, vol.54
, pp. 979-985
-
-
Ronco, C.1
Orlandini, G.2
Brendolan, A.3
Lupi, A.4
La Greca, G.5
-
14
-
-
48349100276
-
Effect of high fiber density ratio polysulfone dialyzer on protein removal
-
Tomo T, Matsuyama M, Nakata T, Kadota J-I, Toma S, Koga N, Fukui H, Arizono K, Takamiya T, Matsuyama K, Ueyama S, Shiohira Y, Uezu Y, Higa A: Effect of high fiber density ratio polysulfone dialyzer on protein removal. Blood Purif 26:347-353, 2008
-
(2008)
Blood Purif
, vol.26
, pp. 347-353
-
-
Tomo, T.1
Matsuyama, M.2
Nakata, T.3
Kadota, J.-I.4
Toma, S.5
Koga, N.6
Fukui, H.7
Arizono, K.8
Takamiya, T.9
Matsuyama, K.10
Ueyama, S.11
Shiohira, Y.12
Uezu, Y.13
Higa, A.14
-
15
-
-
0033868074
-
Effects of a reduced inner diameter of hollow fibers in hemodialyzers
-
Ronco C, Brendolan A, Lupi A, Metry G, Levin NW: Effects of a reduced inner diameter of hollow fibers in hemodialyzers. Kidney Int 58:809-817, 2000
-
(2000)
Kidney Int
, vol.58
, pp. 809-817
-
-
Ronco, C.1
Brendolan, A.2
Lupi, A.3
Metry, G.4
Levin, N.W.5
-
16
-
-
0021645532
-
Technical aspects of high-flux hemodiafiltration for adequate short (under 2hours) treatment
-
Miller JH, von Albertini B, Gardner PW, Shinaberger JH: Technical aspects of high-flux hemodiafiltration for adequate short (under 2hours) treatment. Trans Am Soc Artif Intern Organs 30:377-381, 1984
-
(1984)
Trans Am Soc Artif Intern Organs
, vol.30
, pp. 377-381
-
-
Miller, J.H.1
von Albertini, B.2
Gardner, P.W.3
Shinaberger, J.H.4
-
17
-
-
44449097568
-
Differences in solute removal by two high-flux membranes of nominally similar synthetic polymers
-
Ouseph R, Hutchison CA, Ward RA: Differences in solute removal by two high-flux membranes of nominally similar synthetic polymers. Nephrol Dial Transplant 23:1704-1712, 2008
-
(2008)
Nephrol Dial Transplant
, vol.23
, pp. 1704-1712
-
-
Ouseph, R.1
Hutchison, C.A.2
Ward, R.A.3
-
18
-
-
0027033440
-
A multivariate analysis of mortality and hospital admissions with high-flux dialysis
-
Hornberger JC, Chernew M, Petersen J, Garber AM: A multivariate analysis of mortality and hospital admissions with high-flux dialysis. J Am Soc Nephrol 3:1227-1237, 1992
-
(1992)
J Am Soc Nephrol
, vol.3
, pp. 1227-1237
-
-
Hornberger, J.C.1
Chernew, M.2
Petersen, J.3
Garber, A.M.4
-
19
-
-
0029841840
-
Effect of dialysis membrane on mortality of chronic hemodialysis patients
-
Hakim RM, Held PJ, Stannard DC, Wolfe RA, Port FK, Daugirdas JT, Agodoa L: Effect of dialysis membrane on mortality of chronic hemodialysis patients. Kidney Int 50:566-570, 1996
-
(1996)
Kidney Int
, vol.50
, pp. 566-570
-
-
Hakim, R.M.1
Held, P.J.2
Stannard, D.C.3
Wolfe, R.A.4
Port, F.K.5
Daugirdas, J.T.6
Agodoa, L.7
-
20
-
-
0030768433
-
Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients
-
Koda Y, Nishi S-I, Miyazaki S, Haginoshita S, Sakurabayashi T, Suzuki M, Sakai S, Yuasa Y, Hirasawa Y, Nishi T: Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients. Kidney Int 52:1096-1101, 1997
-
(1997)
Kidney Int
, vol.52
, pp. 1096-1101
-
-
Koda, Y.1
Nishi, S.-I.2
Miyazaki, S.3
Haginoshita, S.4
Sakurabayashi, T.5
Suzuki, M.6
Sakai, S.7
Yuasa, Y.8
Hirasawa, Y.9
Nishi, T.10
-
21
-
-
0032893206
-
Relationship of dialysis membrane and cause-specific mortality
-
Bloembergen WE, Hakim RM, Stannard DC, Held PJ, Wolfe RA, Agodoa LYC, Port FK: Relationship of dialysis membrane and cause-specific mortality. Am J Kidney Dis 33:1-10, 1999
-
(1999)
Am J Kidney Dis
, vol.33
, pp. 1-10
-
-
Bloembergen, W.E.1
Hakim, R.M.2
Stannard, D.C.3
Held, P.J.4
Wolfe, R.A.5
Agodoa, L.Y.C.6
Port, F.K.7
-
22
-
-
46049109167
-
Biocompatibility and permeability of dialyzer membranes do not affect anemia, erythropoietin dosage or mortality in Japanese patients on chronic non-reuse hemodialysis: a prospective cohort study form the J-DOPPS II study
-
Yokoyama H, Kawaguchi T, Wada T, Takahashi Y, Higashi T, Yamazaki S, Fukuhara S, Akiba T, Akizawa T, Asano Y, Kurokawa K, Saito A: Biocompatibility and permeability of dialyzer membranes do not affect anemia, erythropoietin dosage or mortality in Japanese patients on chronic non-reuse hemodialysis: a prospective cohort study form the J-DOPPS II study. Nephron Clin Pract 109:c100-c108, 2008
-
(2008)
Nephron Clin Pract
, vol.109
-
-
Yokoyama, H.1
Kawaguchi, T.2
Wada, T.3
Takahashi, Y.4
Higashi, T.5
Yamazaki, S.6
Fukuhara, S.7
Akiba, T.8
Akizawa, T.9
Asano, Y.10
Kurokawa, K.11
Saito, A.12
-
23
-
-
10244255046
-
Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters
-
Locatelli F, Mastrangelo F, Redaelli B, Ronco C, Marcelli D, La Greca G, Orlandini G: Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters. Kidney Int 50:1293-1302, 1996
-
(1996)
Kidney Int
, vol.50
, pp. 1293-1302
-
-
Locatelli, F.1
Mastrangelo, F.2
Redaelli, B.3
Ronco, C.4
Marcelli, D.5
La Greca, G.6
Orlandini, G.7
-
24
-
-
33846638745
-
Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis
-
Krane V, Krieter DH, Olschewski M, März W, Mann JFE, Ritz E, Wanner C: Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis. Am J Kidney Dis 49:267-275, 2007
-
(2007)
Am J Kidney Dis
, vol.49
, pp. 267-275
-
-
Krane, V.1
Krieter, D.H.2
Olschewski, M.3
März, W.4
Mann, J.F.E.5
Ritz, E.6
Wanner, C.7
-
25
-
-
0026099093
-
Phagocytosis in uremic and hemodialysis patients: a prospective and cross sectional study
-
Vanholder R, Ringoir S, Dhondt A, Hakim R: Phagocytosis in uremic and hemodialysis patients: a prospective and cross sectional study. Kidney Int 39:320-327, 1991
-
(1991)
Kidney Int
, vol.39
, pp. 320-327
-
-
Vanholder, R.1
Ringoir, S.2
Dhondt, A.3
Hakim, R.4
-
26
-
-
0030058767
-
Effect of the membrane biocompatibility on nutritional parameters in chronic hemodialysis patients
-
Parker TF, Wingard RL, Husni L, Ikizler TA, Parker RA, Hakim RM: Effect of the membrane biocompatibility on nutritional parameters in chronic hemodialysis patients. Kidney Int 49:551-556, 1996
-
(1996)
Kidney Int
, vol.49
, pp. 551-556
-
-
Parker, T.F.1
Wingard, R.L.2
Husni, L.3
Ikizler, T.A.4
Parker, R.A.5
Hakim, R.M.6
-
27
-
-
0026077307
-
Acute intradialytic well-being: results of a clinical trial comparing polysulfone with cuprophan
-
Bergamo Collaborative Dialysis Study Group.
-
Bergamo Collaborative Dialysis Study Group: Acute intradialytic well-being: results of a clinical trial comparing polysulfone with cuprophan. Kidney Int 40:714-719, 1991
-
(1991)
Kidney Int
, vol.40
, pp. 714-719
-
-
-
28
-
-
32944461038
-
Cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease
-
3. Art. No.: CD003234. DOI.
-
MacLeod AM, Campbell MK, Cody JD, Daly C, Grant A, Khan I, Rabindranath KS, Vale L, Wallace SA: Cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease. Cochrane Database Syst Rev 2005, 3. Art. No.: CD003234. DOI.
-
(2005)
Cochrane Database Syst Rev
-
-
MacLeod, A.M.1
Campbell, M.K.2
Cody, J.D.3
Daly, C.4
Grant, A.5
Khan, I.6
Rabindranath, K.S.7
Vale, L.8
Wallace, S.A.9
-
29
-
-
0021800312
-
Reactions during hemodialysis caused by allergy to ethylene oxide gas sterilization
-
Marshall CP, Pearson FC, Sagona MA, Lee W, Wathen RL, Ward RA, Dolovich J: Reactions during hemodialysis caused by allergy to ethylene oxide gas sterilization. J Allergy Clin Immunol 75:563-567, 1985
-
(1985)
J Allergy Clin Immunol
, vol.75
, pp. 563-567
-
-
Marshall, C.P.1
Pearson, F.C.2
Sagona, M.A.3
Lee, W.4
Wathen, R.L.5
Ward, R.A.6
Dolovich, J.7
-
30
-
-
0025286541
-
Hypersensitivity reactions during haemodialysis: role of complement fragments and ethylene oxide antibodies
-
Lemke HD, Heidland A, Schaefer RM: Hypersensitivity reactions during haemodialysis: role of complement fragments and ethylene oxide antibodies. Nephrol Dial Transplant 5:264-269, 1990
-
(1990)
Nephrol Dial Transplant
, vol.5
, pp. 264-269
-
-
Lemke, H.D.1
Heidland, A.2
Schaefer, R.M.3
-
31
-
-
0031979879
-
Anaphylactoid reactions during hemodialysis in sheep are ACE inhibitor dose-dependent and mediated by bradykinin
-
Krieter DH, Grude M, Lemke H-D, Fink E, Bönner G, Schölkens BA, Schulz E, Müller GA: Anaphylactoid reactions during hemodialysis in sheep are ACE inhibitor dose-dependent and mediated by bradykinin. Kidney Int 53:1026-1035, 1998
-
(1998)
Kidney Int
, vol.53
, pp. 1026-1035
-
-
Krieter, D.H.1
Grude, M.2
Lemke, H.-D.3
Fink, E.4
Bönner, G.5
Schölkens, B.A.6
Schulz, E.7
Müller, G.A.8
-
32
-
-
38349019673
-
The effect of electronegativity and angiotensin-converting enzyme inhibition on the kinin-forming capacity of polyacrylonitrile dialysis membranes
-
Désormeaux A, Moreau ME, Lepage Y, Chanard J, Adam A: The effect of electronegativity and angiotensin-converting enzyme inhibition on the kinin-forming capacity of polyacrylonitrile dialysis membranes. Biomaterials 29:1139-1146, 2008
-
(2008)
Biomaterials
, vol.29
, pp. 1139-1146
-
-
Désormeaux, A.1
Moreau, M.E.2
Lepage, Y.3
Chanard, J.4
Adam, A.5
-
33
-
-
44449151756
-
Delayed near-fatal anaphylactic reaction induced by the F10-HPS polysulfone haemodialyser
-
Huang W-H, Lee Y-Y, Shih L-C: Delayed near-fatal anaphylactic reaction induced by the F10-HPS polysulfone haemodialyser. Nephrol Dial Transplant 23:423-424, 2008
-
(2008)
Nephrol Dial Transplant
, vol.23
, pp. 423-424
-
-
Huang, W.-H.1
Lee, Y.-Y.2
Shih, L.-C.3
-
34
-
-
77952554373
-
Thrombocytopenia associated with use of a biocompatible hemodialysis membrane: a case report
-
Post JB: Thrombocytopenia associated with use of a biocompatible hemodialysis membrane: a case report. Am J Kidney Dis 55:e25-e28, 2010
-
(2010)
Am J Kidney Dis
, vol.55
-
-
Post, J.B.1
-
35
-
-
0019783774
-
Effect of the hemodialysis prescription on patient morbidity. Report from the National Cooperative Dialysis Study
-
Lowrie EG, Laird NM, Parker TF, Sargent JA: Effect of the hemodialysis prescription on patient morbidity. Report from the National Cooperative Dialysis Study. N Engl J Med 305:1176-1181, 1981
-
(1981)
N Engl J Med
, vol.305
, pp. 1176-1181
-
-
Lowrie, E.G.1
Laird, N.M.2
Parker, T.F.3
Sargent, J.A.4
-
36
-
-
0021783946
-
A mechanistic analysis of the National Cooperative Dialysis Study (NCDS)
-
Gotch FA, Sargent JA: A mechanistic analysis of the National Cooperative Dialysis Study (NCDS). Kidney Int 28:526-534, 1985
-
(1985)
Kidney Int
, vol.28
, pp. 526-534
-
-
Gotch, F.A.1
Sargent, J.A.2
-
37
-
-
0036208604
-
Dialysis dose and body mass index are strongly associated with survival in hemodialysis patients
-
Port FK, Ashby VB, Dhingra RK, Roys EC, Wolfe RA: Dialysis dose and body mass index are strongly associated with survival in hemodialysis patients. J Am Soc Nephrol 13:1061-1066, 2002
-
(2002)
J Am Soc Nephrol
, vol.13
, pp. 1061-1066
-
-
Port, F.K.1
Ashby, V.B.2
Dhingra, R.K.3
Roys, E.C.4
Wolfe, R.A.5
-
38
-
-
21644465205
-
Measurement of dialyzer clearance, dialysis time, and body size: death risk relationship among patients
-
Lowrie EG, Li Z, Ofsthun N, Lazarus JM: Measurement of dialyzer clearance, dialysis time, and body size: death risk relationship among patients. Kidney Int 66:2077-2084, 2004
-
(2004)
Kidney Int
, vol.66
, pp. 2077-2084
-
-
Lowrie, E.G.1
Li, Z.2
Ofsthun, N.3
Lazarus, J.M.4
-
39
-
-
33745285983
-
Clinical practice guidelines for hemodialysis adequacy, update 2006
-
Hemodialysis Adequacy 2006 Work Group.
-
Hemodialysis Adequacy 2006 Work Group: Clinical practice guidelines for hemodialysis adequacy, update 2006. Am J Kidney Dis 48(Suppl 1):S2-S90, 2006
-
(2006)
Am J Kidney Dis
, vol.48
, Issue.SUPPL. 1
-
-
-
40
-
-
12144285940
-
Dialysis dose and the effect of gender and body size on outcome in the HEMO Study
-
Depner T, Daugirdas J, Greene T, Allon M, Beck G, Chumlea C, Delmez J, Gotch F, Kusek J, Levin N, Macon E, Milford E, Owen W, Star R, Toto R, Eknoyan G: Dialysis dose and the effect of gender and body size on outcome in the HEMO Study. Kidney Int 65:1386-1394, 2004
-
(2004)
Kidney Int
, vol.65
, pp. 1386-1394
-
-
Depner, T.1
Daugirdas, J.2
Greene, T.3
Allon, M.4
Beck, G.5
Chumlea, C.6
Delmez, J.7
Gotch, F.8
Kusek, J.9
Levin, N.10
Macon, E.11
Milford, E.12
Owen, W.13
Star, R.14
Toto, R.15
Eknoyan, G.16
-
41
-
-
77957291655
-
Can rescaling dose of dialysis to body surface area in the HEMO Study explain the different responses to dose in women versus men?
-
Daugirdas JT, Greene T, Chertow GM, Depner TA: Can rescaling dose of dialysis to body surface area in the HEMO Study explain the different responses to dose in women versus men? Clin J Am Soc Nephrol 5:1628-1636, 2010
-
(2010)
Clin J Am Soc Nephrol
, vol.5
, pp. 1628-1636
-
-
Daugirdas, J.T.1
Greene, T.2
Chertow, G.M.3
Depner, T.A.4
-
42
-
-
0033042913
-
Effect of dialysis membrane and middle molecule removal on chronic hemodialysis patient survival
-
Leypoldt JK, Cheung AK, Carroll CE, Stannard DC, Pereira BJ, Agodoa LY, Port FK: Effect of dialysis membrane and middle molecule removal on chronic hemodialysis patient survival. Am J Kidney Dis 33:349-355, 1999
-
(1999)
Am J Kidney Dis
, vol.33
, pp. 349-355
-
-
Leypoldt, J.K.1
Cheung, A.K.2
Carroll, C.E.3
Stannard, D.C.4
Pereira, B.J.5
Agodoa, L.Y.6
Port, F.K.7
-
43
-
-
44049106323
-
A bench to bedside view of uremic toxins
-
Vanholder R, Baurmeister U, Brunet P, Cohen G, Glorieux G, Jankowski J: A bench to bedside view of uremic toxins. J Am Soc Nephrol 19:863-870, 2008
-
(2008)
J Am Soc Nephrol
, vol.19
, pp. 863-870
-
-
Vanholder, R.1
Baurmeister, U.2
Brunet, P.3
Cohen, G.4
Glorieux, G.5
Jankowski, J.6
-
44
-
-
0033999037
-
Improved outcome for haemodialysis patients treated with high-flux membranes
-
Woods HF, Nandakumar M: Improved outcome for haemodialysis patients treated with high-flux membranes. Nephrol Dial Transplant 15(Suppl 1):36-42, 2000
-
(2000)
Nephrol Dial Transplant
, vol.15
, Issue.SUPPL. 1
, pp. 36-42
-
-
Woods, H.F.1
Nandakumar, M.2
-
45
-
-
62149106664
-
Effect of membrane permeability on survival of hemodialysis patients
-
Locatelli F, Martin-Melo A, Hannedouche T, Loureiro A, Papadimitriou V, Wizemann V, Jacobson SH, Czekalski S, Ronco C, Vanholder R: Effect of membrane permeability on survival of hemodialysis patients. J Am Soc Nephrol 20:645-654, 2009
-
(2009)
J Am Soc Nephrol
, vol.20
, pp. 645-654
-
-
Locatelli, F.1
Martin-Melo, A.2
Hannedouche, T.3
Loureiro, A.4
Papadimitriou, V.5
Wizemann, V.6
Jacobson, S.H.7
Czekalski, S.8
Ronco, C.9
Vanholder, R.10
-
46
-
-
0345098607
-
Effects of high-flux hemodialysis on clinical outcomes: results of the HEMO Study
-
Cheung AK, Levin NW, Greene T, Agodoa L, Bailey J, Beck G, Clark W, Levey AS, Leypoldt JK, Ornt DB, Rocco MV, Schulman G, Schwab S, Teehan B, Eknoyan G: Effects of high-flux hemodialysis on clinical outcomes: results of the HEMO Study. J Am Soc Nephrol 14:3251-3263, 2003
-
(2003)
J Am Soc Nephrol
, vol.14
, pp. 3251-3263
-
-
Cheung, A.K.1
Levin, N.W.2
Greene, T.3
Agodoa, L.4
Bailey, J.5
Beck, G.6
Clark, W.7
Levey, A.S.8
Leypoldt, J.K.9
Ornt, D.B.10
Rocco, M.V.11
Schulman, G.12
Schwab, S.13
Teehan, B.14
Eknoyan, G.15
-
47
-
-
33645460223
-
2-microglobulin levels predict mortality in dialysis patients: Results of the HEMO Study
-
2-microglobulin levels predict mortality in dialysis patients: Results of the HEMO Study. J Am Soc Nephrol 17:546-555, 2006
-
(2006)
J Am Soc Nephrol
, vol.17
, pp. 546-555
-
-
Cheung, A.K.1
Rocco, M.V.2
Yan, G.3
Leypoldt, J.K.4
Levin, N.W.5
Greene, T.6
Agodoa, L.7
Bailey, J.8
Beck, G.J.9
Clark, W.10
Levey, A.S.11
Ornt, D.B.12
Schulman, G.13
Schwab, S.14
Teehan, B.15
Eknoyan, G.16
-
48
-
-
38749086528
-
2-microglobulin level and infectious mortality in hemodialysis patients
-
2-microglobulin level and infectious mortality in hemodialysis patients. Clin J Am Soc Nephrol 3:69-77, 2008
-
(2008)
Clin J Am Soc Nephrol
, vol.3
, pp. 69-77
-
-
Cheung, A.K.1
Greene, T.2
Leypoldt, J.K.3
Yan, G.4
Allon, M.5
Delmez, J.6
Levey, A.S.7
Levin, N.W.8
Rocco, M.V.9
Schulman, G.10
Eknoyan, G.11
-
49
-
-
0344791708
-
2-microglobulin
-
2-microglobulin. J Am Soc Nephrol 10:117-127, 1999
-
(1999)
J Am Soc Nephrol
, vol.10
, pp. 117-127
-
-
Cheung, A.K.1
Agodoa, L.Y.2
Daugirdas, J.T.3
Depner, T.A.4
Gotch, F.A.5
Greene, T.6
Levin, N.W.7
Leypoldt, J.K.8
-
50
-
-
33745241637
-
Mortality risk for patients receiving hemodiafiltration versus hemodialysis: European results from the DOPPS
-
Canaud B, Bragg-Gresham JL, Marshall MR, Desmeules S, Gillespie BW, Depner T, Klassen P, Port FK: Mortality risk for patients receiving hemodiafiltration versus hemodialysis: European results from the DOPPS. Kidney Int 69:2087-2093, 2006
-
(2006)
Kidney Int
, vol.69
, pp. 2087-2093
-
-
Canaud, B.1
Bragg-Gresham, J.L.2
Marshall, M.R.3
Desmeules, S.4
Gillespie, B.W.5
Depner, T.6
Klassen, P.7
Port, F.K.8
-
51
-
-
73649088259
-
Long-term outcomes in online hemodiafiltration and high-flux hemodialysis: a comparative analysis
-
Vilar E, Fry AC, Wellsted D, Tattersall JE, Greenwood RN, Farrington K: Long-term outcomes in online hemodiafiltration and high-flux hemodialysis: a comparative analysis. Clin J Am Soc Nephrol 4:1944-1953, 2009
-
(2009)
Clin J Am Soc Nephrol
, vol.4
, pp. 1944-1953
-
-
Vilar, E.1
Fry, A.C.2
Wellsted, D.3
Tattersall, J.E.4
Greenwood, R.N.5
Farrington, K.6
-
52
-
-
49749084921
-
The effect of on-line high-flux hemofiltration versus low-flux hemodialysis on mortality in chronic kidney failure: a small randomized controlled trial
-
Santoro A, Mancini E, Bolzani R, Boggi R, Cagnoli L, Francioso A, Fusaroli M, Piazza V, Rapanà R, Strippoli GFM: The effect of on-line high-flux hemofiltration versus low-flux hemodialysis on mortality in chronic kidney failure: a small randomized controlled trial. Am J Kidney Dis 52:507-518, 2008
-
(2008)
Am J Kidney Dis
, vol.52
, pp. 507-518
-
-
Santoro, A.1
Mancini, E.2
Bolzani, R.3
Boggi, R.4
Cagnoli, L.5
Francioso, A.6
Fusaroli, M.7
Piazza, V.8
Rapanà, R.9
Strippoli, G.F.M.10
-
53
-
-
77949541564
-
Hemodiafiltration: clinical evidence and remaining questions
-
Blankestijn PJ, Ledebo I, Canaud B: Hemodiafiltration: clinical evidence and remaining questions. Kidney Int 77:581-587, 2010
-
(2010)
Kidney Int
, vol.77
, pp. 581-587
-
-
Blankestijn, P.J.1
Ledebo, I.2
Canaud, B.3
|