메뉴 건너뛰기




Volumn 30, Issue 3, 2011, Pages 273-276

Comparison of bifold forceps and cartridge injector suture pull-through insertion techniques for descemet stripping automated endothelial keratoplasty

Author keywords

Descemet stripping automated endothelial keratoplasty; endothelium; forceps insertion; graft survival; suture pull through insertion; visual acuity

Indexed keywords

ADULT; AGED; ARTICLE; BIFOLD FORCEP; CARTRIDGE INJECTOR SUTURE; CELL LOSS; CONTROLLED STUDY; CORNEA EDEMA; DESCEMET STRIPPING ENDOTHELIAL KERATOPLASTY; ENDOTHELIUM CELL; EYE EXAMINATION; FORCEPS; GRAFT FAILURE; GRAFT SURVIVAL; HUMAN; LENS LUXATION; MAJOR CLINICAL STUDY; MEDICAL RECORD REVIEW; MULTICENTER STUDY; OUTCOME ASSESSMENT; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PSEUDOPHAKIA; RETROSPECTIVE STUDY; SURGICAL TECHNIQUE; SUTURE; TREATMENT OUTCOME; UNIVERSITY HOSPITAL; VISION; VISUAL ACUITY;

EID: 79951771686     PISSN: 02773740     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICO.0b013e3181eadb84     Document Type: Article
Times cited : (11)

References (24)
  • 1
    • 0031729571 scopus 로고    scopus 로고
    • A surgical technique for posterior lamellarkeratoplasty
    • Melles GR, Egglink FA, Lander F, et al. A surgical technique for posterior lamellarkeratoplasty. Cornea. 1998;17:618-626.
    • (1998) Cornea , vol.17 , pp. 618-626
    • Melles, G.R.1    Egglink, F.A.2    Lander, F.3
  • 2
    • 0035080291 scopus 로고    scopus 로고
    • Deep lamellar endothelial keratoplasty in the first United States patients
    • DOI 10.1097/00003226-200104000-00001
    • Terry MA, Ousley PJ. Deep lamellar endothelial keratoplasty in the first United States patients: early clinical results. Cornea. 2001; 20:239-243. (Pubitemid 32239259)
    • (2001) Cornea , vol.20 , Issue.3 , pp. 239-243
    • Terry, M.A.1    Ousley, P.J.2
  • 3
    • 33751110218 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty
    • DOI 10.1097/01.ico.0000214224.90743.01, PII 0000322620060900000005
    • Gorovoy MS. Descemet-stripping automated endothelial keratoplasty. Cornea. 2006;25:886-889. (Pubitemid 44763845)
    • (2006) Cornea , vol.25 , Issue.8 , pp. 886-889
    • Gorovoy, M.S.1
  • 4
    • 33646036099 scopus 로고    scopus 로고
    • Descemet's stripping with endothelial keratoplasty in 200 eyes: Early challenges andtechniques to enhance donor adherence
    • Price FW Jr, Price MO. Descemet's stripping with endothelial keratoplasty in 200 eyes: early challenges andtechniques to enhance donor adherence. J Cataract Refract Surg. 2006;32:411-418.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 411-418
    • Price Jr., F.W.1    Price, M.O.2
  • 5
    • 43049086352 scopus 로고    scopus 로고
    • Surgical alternative to penetrating keratoplasty II: Endothelial keratoplasty
    • Goins KM. Surgical alternative to penetrating keratoplasty II: endothelial keratoplasty. Int Ophthalmol. 2008;28:223-246.
    • (2008) Int Ophthalmol , vol.28 , pp. 223-246
    • Goins, K.M.1
  • 6
    • 34447538252 scopus 로고    scopus 로고
    • Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK)
    • DOI 10.1097/ICO.0b013e3180544902, PII 0000322620070700000005
    • Koenig SB, Covert DJ, Dupps WJ Jr, et al. Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automatedendothelial keratoplasty (DSAEK). Cornea. 2007;26:670-674. (Pubitemid 47080283)
    • (2007) Cornea , vol.26 , Issue.6 , pp. 670-674
    • Koenig, S.B.1    Covert, D.J.2    Dupps Jr., W.J.3    Meisler, D.M.4
  • 7
    • 67349147446 scopus 로고    scopus 로고
    • Endothelial keratoplasty: Vision, endothelial survival, and complications in a comparative case series of fellows vs attending surgeons
    • Chen ES, Terry MA, Shamie N, et al. Endothelial keratoplasty: vision, endothelial survival, and complications in a comparative case series of fellows vs attending surgeons. Am J Ophthalmol. 2009;148:26-31.
    • (2009) Am J Ophthalmol , vol.148 , pp. 26-31
    • Chen, E.S.1    Terry, M.A.2    Shamie, N.3
  • 8
    • 37249072820 scopus 로고    scopus 로고
    • Novel Delivery Method to Reduce Endothelial Injury in Descemet Stripping Automated Endothelial Keratoplasty
    • DOI 10.1016/j.ajo.2007.08.036, PII S0002939407007829
    • Kuo AN, Harvey TM, Afshari NA. Novel delivery method to reduce endothelial injury in Descemet stripping automated endothelial kerato-plasty. Am J Ophthalmol. 2008;145:91-96. (Pubitemid 350265758)
    • (2008) American Journal of Ophthalmology , vol.145 , Issue.1 , pp. 91-96
    • Kuo, A.N.1    Harvey, T.M.2    Afshari, N.A.3
  • 9
    • 49849086629 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty: Effect of anterior lamellar corneal tissue-on/-off storage condition on Descemet-stripping automated endothelial kerato-plasty donor tissue
    • Ide T, Yoo SH, Kymionis GD, et al. Descemet-stripping automated endothelial keratoplasty: effect of anterior lamellar corneal tissue-on/-off storage condition on Descemet-stripping automated endothelial kerato-plasty donor tissue. Cornea. 2008;27:754-757.
    • (2008) Cornea , vol.27 , pp. 754-757
    • Ide, T.1    Yoo, S.H.2    Kymionis, G.D.3
  • 10
    • 43949110570 scopus 로고    scopus 로고
    • Suture-assisted vs forceps-assisted insertion of the donor lenticula during Descemet stripping automated endothelial keratoplasty
    • Kaiserman I, Bahar I, McAllum P, et al. Suture-assisted vs forceps-assisted insertion of the donor lenticula during Descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2008;145: 986-990.
    • (2008) Am J Ophthalmol , vol.145 , pp. 986-990
    • Kaiserman, I.1    Bahar, I.2    McAllum, P.3
  • 11
    • 34748817999 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty: Effect of inserting forceps on DSAEK donor tissue viability by using an in vitro delivery model and vital dye assay
    • DOI 10.1097/ICO.0b013e318142bdde, PII 0000322620071000000012
    • Ide T, Yoo SH, Goldman JM, et al. Descemet-stripping automated endothelial keratoplasty: effect of inserting forceps on DSAEK donor tissue viability by using an in vitro delivery model and vital dye assay. Cornea. 2007;26:1079-1081. (Pubitemid 47480689)
    • (2007) Cornea , vol.26 , Issue.9 , pp. 1079-1081
    • Ide, T.1    Yoo, S.H.2    Goldman, J.M.3    Perez, V.4    O'Brien, T.P.5
  • 12
    • 34250654476 scopus 로고    scopus 로고
    • Descemet's stripping automated endothelial keratoplasty in intraoperative floppy-iris syndrome: Suture-drag technique
    • DOI 10.1016/j.jcrs.2007.03.043, PII S0886335007006542
    • Bradley JC, McCartney DL. Descemet's stripping automated endothelial keratoplasty in intraoperative floppy-iris syndrome: suture-drag tech-nique. J Cataract Refract Surg. 2007;33:1149-1150. (Pubitemid 46936142)
    • (2007) Journal of Cataract and Refractive Surgery , vol.33 , Issue.7 , pp. 1149-1150
    • Bradley, J.C.1    McCartney, D.L.2
  • 13
    • 49849091927 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial kerato-plasty by using suture for donor insertion
    • Sarnicola V, Toro P. Descemet-stripping automated endothelial kerato-plasty by using suture for donor insertion. Cornea. 2008;27:825-829.
    • (2008) Cornea , vol.27 , pp. 825-829
    • Sarnicola, V.1    Toro, P.2
  • 14
    • 40949148129 scopus 로고    scopus 로고
    • Graft insertion during Descemet-stripping automated endothelial keratoplasty: Pulling the graft inward
    • DOI 10.1016/j.jcrs.2007.12.029, PII S0886335008000990
    • Van Cleynenbreugel H, Hillenaar T, Remeijer L. Graft insertion during Descemet-stripping automated endothelial keratoplasty: pulling the graft inward. J Cataract Refract Surg. 2008;34:534-536. (Pubitemid 351417620)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.4 , pp. 534-536
    • Van Cleynenbreugel, H.1    Hillenaar, T.2    Remeijer, L.3
  • 15
    • 34748838385 scopus 로고    scopus 로고
    • Kara-Jose AC Suture technique for Descemet stripping and endothelial keratoplasty
    • Macsai MS, Kara-Jose AC Suture technique for Descemet stripping and endothelial keratoplasty. Cornea. 2007;26:1123-1126.
    • (2007) Cornea , vol.26 , pp. 1123-1126
    • MacSai, M.S.1
  • 16
    • 33646696175 scopus 로고    scopus 로고
    • Small incision insertion of posterior lamellar button [1]
    • Harvey TM. Small incision insertion of posterior lamellar button. J Refract Surg. 2006;22:429. (Pubitemid 43736466)
    • (2006) Journal of Refractive Surgery , vol.22 , Issue.5 , pp. 429
    • Harvey, T.M.1
  • 17
    • 50549098243 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty: Insertion using a novel 40/60 underfold technique for preservation of donor endothelium
    • Chen ES, Terry MA, Shamie N, et al. Descemet-stripping automated endothelial keratoplasty: insertion using a novel 40/60 underfold technique for preservation of donor endothelium. Cornea. 2008;27: 941-943.
    • (2008) Cornea , vol.27 , pp. 941-943
    • Chen, E.S.1    Terry, M.A.2    Shamie, N.3
  • 18
    • 49449089875 scopus 로고    scopus 로고
    • A modified technique for Descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss
    • Busin M, Bhatt PR, Scorcia V A modified technique for Descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss. Arch Ophthalmol. 2008;126:1133-1137.
    • (2008) Arch Ophthalmol , vol.126 , pp. 1133-1137
    • Busin, M.1    Bhatt, P.R.2    Scorcia, V.3
  • 19
    • 35448932806 scopus 로고    scopus 로고
    • Glide insertion technique for donor cornea lenticule during Descemet's stripping automated endothelial keratoplasty
    • DOI 10.1016/j.jcrs.2007.06.050, PII S0886335007013764
    • Mehta JS, Por YM, Beuerman RW, et al. Glide insertion technique for donor cornea lenticule during Descemet's stripping automated endothelial keratoplasty. J Cataract Refract Surg. 2007;33:1846-1850. (Pubitemid 47628806)
    • (2007) Journal of Cataract and Refractive Surgery , vol.33 , Issue.11 , pp. 1846-1850
    • Mehta, J.S.1    Por, Y.-M.2    Beuerman, R.W.3    Tan, D.T.4
  • 20
    • 54049145940 scopus 로고    scopus 로고
    • Comparison of donor insertion techniques for Descemet stripping automated endothelial keratoplasty
    • Mehta JS, Por YM, Poh R, et al. Comparison of donor insertion techniques for Descemet stripping automated endothelial keratoplasty. Arch Ophthalmol. 2008;126:1383-1388.
    • (2008) Arch Ophthalmol , vol.126 , pp. 1383-1388
    • Mehta, J.S.1    Por, Y.M.2    Poh, R.3
  • 22
    • 51649106309 scopus 로고    scopus 로고
    • Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy\preliminary results and usefulness ofdouble-glide donor insertion technique
    • Kobayashi A, Yokogawa H, Sugiyama K. Descemet stripping with automated endothelial keratoplasty for bullous keratopathies secondary to argon laser iridotomy\preliminary results and usefulness ofdouble-glide donor insertion technique. Cornea. 2008;27(Suppl 1):S62-S69.
    • (2008) Cornea , vol.27 , Issue.SUPPL. 1
    • Kobayashi, A.1    Yokogawa, H.2    Sugiyama, K.3
  • 23
    • 41949108536 scopus 로고    scopus 로고
    • Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty
    • Macaluso C. Closed-chamber pulling-injection system for donor graft insertion in endothelial keratoplasty. J Cataract Refract Surg. 2008;34: 353-356.
    • (2008) J Cataract Refract Surg , vol.34 , pp. 353-356
    • MacAluso, C.1
  • 24
    • 58249102260 scopus 로고    scopus 로고
    • Busin guide vs forceps for the insertion of the donor lenticule in Descemet stripping automated endothelial keratoplasty
    • Bahar I, Kaiserman I, Sansanayudh W, et al. Busin guide vs forceps for the insertion of the donor lenticule in Descemet stripping automated endothelial keratoplasty. Am J Ophthalmol. 2009;147:220-226
    • (2009) Am J Ophthalmol , vol.147 , pp. 220-226
    • Bahar, I.1    Kaiserman, I.2    Sansanayudh, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.