메뉴 건너뛰기




Volumn 147, Issue 2, 2009, Pages

Busin Guide vs Forceps for the Insertion of the Donor Lenticule in Descemet Stripping Automated Endothelial Keratoplasty

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; APHAKIA; ARTICLE; BUSIN; CLINICAL TRIAL; CONGENITAL CORNEA DYSTROPHY; CONTROLLED STUDY; CORNEA; CORNEA DISEASE; CORNEA TRANSPLANTATION; DESCEMET STRIPPING AUTOMATED ENDOTHELIAL KERATOPLASTY; FEMALE; FORCEPS; GRAFT FAILURE; HUMAN; INTERMETHOD COMPARISON; IRIDOCORNEO ENDOTHELIAL SYNDROME; KERATOPLASTY; LENS; MAJOR CLINICAL STUDY; MALE; ORGAN DONOR; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PSEUDOPHAKIA; SURGICAL EQUIPMENT; TREATMENT OUTCOME; VISUAL ACUITY;

EID: 58249102260     PISSN: 00029394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajo.2008.08.029     Document Type: Article
Times cited : (84)

References (21)
  • 1
    • 22644443452 scopus 로고    scopus 로고
    • Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant
    • Price Jr. F.W., and Price M.O. Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg 21 (2005) 339-345
    • (2005) J Refract Surg , vol.21 , pp. 339-345
    • Price Jr., F.W.1    Price, M.O.2
  • 2
    • 33646036099 scopus 로고    scopus 로고
    • Descemet's stripping with endothelial keratoplasty in 200 eyes: early challenges and techniques to enhance donor adherence
    • Price Jr. F.W., and Price M.O. Descemet's stripping with endothelial keratoplasty in 200 eyes: early challenges and techniques to enhance donor adherence. J Cataract Refract Surg 32 (2006) 411-418
    • (2006) J Cataract Refract Surg , vol.32 , pp. 411-418
    • Price Jr., F.W.1    Price, M.O.2
  • 3
    • 33846534105 scopus 로고    scopus 로고
    • Early results of small-incision Descemet's stripping and automated endothelial keratoplasty
    • Koenig S.B., and Covert D.J. Early results of small-incision Descemet's stripping and automated endothelial keratoplasty. Ophthalmology 114 (2007) 221-226
    • (2007) Ophthalmology , vol.114 , pp. 221-226
    • Koenig, S.B.1    Covert, D.J.2
  • 4
    • 34447538252 scopus 로고    scopus 로고
    • Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK)
    • Koenig S.B., Covert D.J., Dupps Jr. W.J., et al. Visual acuity, refractive error, and endothelial cell density six months after Descemet stripping and automated endothelial keratoplasty (DSAEK). Cornea 26 (2007) 670-674
    • (2007) Cornea , vol.26 , pp. 670-674
    • Koenig, S.B.1    Covert, D.J.2    Dupps Jr., W.J.3
  • 5
    • 33751110218 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty
    • Gorovoy M.S. Descemet-stripping automated endothelial keratoplasty. Cornea 25 (2006) 886-889
    • (2006) Cornea , vol.25 , pp. 886-889
    • Gorovoy, M.S.1
  • 6
    • 33947573351 scopus 로고    scopus 로고
    • A prospective study of endothelial cell loss during the 2 years after deep lamellar endothelial keratoplasty
    • Terry M.A., Wall J.M., Hoar K.L., et al. A prospective study of endothelial cell loss during the 2 years after deep lamellar endothelial keratoplasty. Ophthalmology 114 (2007) 631-639
    • (2007) Ophthalmology , vol.114 , pp. 631-639
    • Terry, M.A.1    Wall, J.M.2    Hoar, K.L.3
  • 7
    • 43949110570 scopus 로고    scopus 로고
    • Suture-assisted vs forceps-assisted insertion of the donor lenticula during Descemet stripping automated endothelial keratoplasty
    • Kaiserman I., Bahar I., McAllum P., et al. Suture-assisted vs forceps-assisted insertion of the donor lenticula during Descemet stripping automated endothelial keratoplasty. Am J Ophthalmol 145 (2008) 986-990
    • (2008) Am J Ophthalmol , vol.145 , pp. 986-990
    • Kaiserman, I.1    Bahar, I.2    McAllum, P.3
  • 8
    • 34748817999 scopus 로고    scopus 로고
    • Descemet-stripping automated endothelial keratoplasty: effect of inserting forceps on DSAEK donor tissue viability by using an in vitro delivery model and vital dye assay
    • Ide T., Yoo S.H., Goldman J.M., et al. Descemet-stripping automated endothelial keratoplasty: effect of inserting forceps on DSAEK donor tissue viability by using an in vitro delivery model and vital dye assay. Cornea 26 (2007) 1079-1081
    • (2007) Cornea , vol.26 , pp. 1079-1081
    • Ide, T.1    Yoo, S.H.2    Goldman, J.M.3
  • 9
    • 37249072820 scopus 로고    scopus 로고
    • Novel delivery method to reduce endothelial injury in Descemet stripping automated endothelial keratoplasty
    • Kuo A.N., Harvey T.M., and Afshari N.A. Novel delivery method to reduce endothelial injury in Descemet stripping automated endothelial keratoplasty. Am J Ophthalmol 145 (2008) 91-96
    • (2008) Am J Ophthalmol , vol.145 , pp. 91-96
    • Kuo, A.N.1    Harvey, T.M.2    Afshari, N.A.3
  • 10
    • 33646696175 scopus 로고    scopus 로고
    • Small incision insertion of posterior lamellar button
    • Harvey T.M. Small incision insertion of posterior lamellar button. J Refract Surg 22 (2006) 429
    • (2006) J Refract Surg , vol.22 , pp. 429
    • Harvey, T.M.1
  • 12
    • 34748838385 scopus 로고    scopus 로고
    • Suture technique for Descemet stripping and endothelial keratoplasty
    • Macsai M.S., and Kara-Jose A.C. Suture technique for Descemet stripping and endothelial keratoplasty. Cornea 26 (2007) 1123-1126
    • (2007) Cornea , vol.26 , pp. 1123-1126
    • Macsai, M.S.1    Kara-Jose, A.C.2
  • 13
    • 40949148129 scopus 로고    scopus 로고
    • Graft insertion during Descemet-stripping automated endothelial keratoplasty: pulling the graft inward
    • Van Cleynenbreugel H., Hillenaar T., and Remeijer L. Graft insertion during Descemet-stripping automated endothelial keratoplasty: pulling the graft inward. J Cataract Refract Surg 34 (2008) 534-536
    • (2008) J Cataract Refract Surg , vol.34 , pp. 534-536
    • Van Cleynenbreugel, H.1    Hillenaar, T.2    Remeijer, L.3
  • 14
    • 34250654476 scopus 로고    scopus 로고
    • Descemet's stripping automated endothelial keratoplasty in intraoperative floppy-iris syndrome: suture-drag technique
    • Bradley J.C., and McCartney D.L. Descemet's stripping automated endothelial keratoplasty in intraoperative floppy-iris syndrome: suture-drag technique. J Cataract Refract Surg 33 (2007) 1149-1150
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1149-1150
    • Bradley, J.C.1    McCartney, D.L.2
  • 15
    • 58249113756 scopus 로고    scopus 로고
    • Srinivasan S, McAllum P, Bahar I, et al. Stromal trimming of the donor disc: a technique to promote graft adherence and centration following Descemet's stripping automated endothelial keratoplasty. Br J Ophthalmol. Forthcoming.
    • Srinivasan S, McAllum P, Bahar I, et al. Stromal trimming of the donor disc: a technique to promote graft adherence and centration following Descemet's stripping automated endothelial keratoplasty. Br J Ophthalmol. Forthcoming.
  • 16
    • 50249098074 scopus 로고    scopus 로고
    • Comparison of posterior lamellar keratoplasty techniques to penetrating keratoplasty
    • Bahar I., Kaiserman I., McAllum P., et al. Comparison of posterior lamellar keratoplasty techniques to penetrating keratoplasty. Ophthalmology 115 (2008) 1525-1533
    • (2008) Ophthalmology , vol.115 , pp. 1525-1533
    • Bahar, I.1    Kaiserman, I.2    McAllum, P.3
  • 17
    • 38649121722 scopus 로고    scopus 로고
    • Corneal profile analysis after Descemet stripping endothelial keratoplasty and its relationship to postoperative hyperopic shift
    • Holz H.A., Meyer J.J., Espandar L., et al. Corneal profile analysis after Descemet stripping endothelial keratoplasty and its relationship to postoperative hyperopic shift. J Cataract Refract Surg 34 (2008) 211-214
    • (2008) J Cataract Refract Surg , vol.34 , pp. 211-214
    • Holz, H.A.1    Meyer, J.J.2    Espandar, L.3
  • 18
    • 39749200812 scopus 로고    scopus 로고
    • Precut tissue in Descemet's stripping automated endothelial keratoplasty donor characteristics and early postoperative complications
    • Chen E.S., Terry M.A., Shamie N., et al. Precut tissue in Descemet's stripping automated endothelial keratoplasty donor characteristics and early postoperative complications. Ophthalmology 115 (2008) 497-502
    • (2008) Ophthalmology , vol.115 , pp. 497-502
    • Chen, E.S.1    Terry, M.A.2    Shamie, N.3
  • 19
    • 45849090360 scopus 로고    scopus 로고
    • Endothelial keratoplasty a simplified technique to minimize graft dislocation, iatrogenic graft failure, and pupillary block
    • Terry M.A., Shamie N., Chen E.S., et al. Endothelial keratoplasty a simplified technique to minimize graft dislocation, iatrogenic graft failure, and pupillary block. Ophthalmology 115 (2008) 1179-1186
    • (2008) Ophthalmology , vol.115 , pp. 1179-1186
    • Terry, M.A.1    Shamie, N.2    Chen, E.S.3
  • 20
    • 45449097829 scopus 로고    scopus 로고
    • Randomized, prospective comparison of precut vs surgeon-dissected grafts for Descemet stripping automated endothelial keratoplasty
    • Price M.O., Baig K.M., Brubaker J.W., et al. Randomized, prospective comparison of precut vs surgeon-dissected grafts for Descemet stripping automated endothelial keratoplasty. Am J Ophthalmol 146 (2008) 36-41
    • (2008) Am J Ophthalmol , vol.146 , pp. 36-41
    • Price, M.O.1    Baig, K.M.2    Brubaker, J.W.3
  • 21
    • 49449089875 scopus 로고    scopus 로고
    • A modified technique for Descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss
    • Busin M., Bhatt P.R., and Scorcia V. A modified technique for Descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss. Arch Ophthalmol 126 (2008) 1133-1137
    • (2008) Arch Ophthalmol , vol.126 , pp. 1133-1137
    • Busin, M.1    Bhatt, P.R.2    Scorcia, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.