Volumn 26, Issue 1, 2011, Pages 17-22

Plasma extraction rate and collection efficiency during therapeutic plasma exchange with Spectra Optia in comparison with Haemonetics MCS+

Author keywords

apheresis; flow separator; performances

Indexed keywords

ARTICLE; CHRONIC DISEASE; CLINICAL ARTICLE; COMPARATIVE STUDY; CROSSOVER PROCEDURE; ERYTHROCYTE COUNT; HUMAN; PLASMA VOLUME; PLASMAPHERESIS; RANDOMIZED CONTROLLED TRIAL; TREATMENT OUTCOME;

EID: 79951738379     PISSN: 07332459     EISSN: 10981101     Source Type: Journal    
DOI: 10.1002/jca.20271     Document Type: Article
Times cited : (21)

References (20)
  • 3
    • 79951754052 scopus 로고    scopus 로고
    • An initial Single-Center experience with plasma exchange on the Spectra Optia cell separator machine: 106 consecutive Optia procedures compared to 114 consecutive COBE Spectra Procedures on the same patient group
    • Douglas KW, McGarvey M, Robertson S, Taylor S, Sinclair JE,. An initial Single-Center experience with plasma exchange on the Spectra Optia cell separator machine: 106 consecutive Optia procedures compared to 114 consecutive COBE Spectra Procedures on the same patient group. J Clin Apher 2008; 23: 17-18.
    • (2008) J Clin Apher , vol.23 , pp. 17-18
    • Douglas, K.W.1    McGarvey, M.2    Robertson, S.3    Taylor, S.4    Sinclair, J.E.5
  • 4
    • 79951743037 scopus 로고    scopus 로고
    • Therapeutic plasma exchange with the new continuous blood flow separator Spectra Optia
    • Lefebre PA, Poulin P,. Therapeutic plasma exchange with the new continuous blood flow separator Spectra Optia. J Clin Apher 2008; 23: 43.
    • (2008) J Clin Apher , vol.23 , pp. 43
    • Lefebre, P.A.1    Poulin, P.2
  • 5
    • 79951750307 scopus 로고    scopus 로고
    • Therapeutic plasma exchange employing the new Spectra Optia 1.0 device: The Italian experience
    • Perotti C, Del Fante C, Viarengo VL, Bergamaschi P, Salvaneschi L,. Therapeutic plasma exchange employing the new Spectra Optia 1.0 device: the Italian experience. Vox Sang 2008; 95 (Suppl 1): 20-21.
    • (2008) Vox Sang , vol.95 , Issue.SUPPL. 1 , pp. 20-21
    • Perotti, C.1    Del Fante, C.2    Viarengo, V.L.3    Bergamaschi, P.4    Salvaneschi, L.5
  • 6
    • 79951749138 scopus 로고    scopus 로고
    • Preliminary experience using the Spectra Optia apheresis system fo therapeutic plasma exchange procedures
    • Roxby D, Foale A, Sumsion D, McDonald M, McArdle S,. Preliminary experience using the Spectra Optia apheresis system fo therapeutic plasma exchange procedures. J Clin Apher 2008; 23: 18-19.
    • (2008) J Clin Apher , vol.23 , pp. 18-19
    • Roxby, D.1    Foale, A.2    Sumsion, D.3    McDonald, M.4    McArdle, S.5
  • 7
    • 79951740576 scopus 로고    scopus 로고
    • Interim analysis of a routine use trial of TPE using the Gambro Spectra Optia: A new generation of therapeutic apheresis platforms
    • Theunissen K, Bracke K, Berckmans D, Steward J, Beck A, Smith R,. Interim analysis of a routine use trial of TPE using the Gambro Spectra Optia: a new generation of therapeutic apheresis platforms. Transfusion 2007; 47 (Suppl): 55A.
    • (2007) Transfusion , vol.47 , Issue.SUPPL.
    • Theunissen, K.1    Bracke, K.2    Berckmans, D.3    Steward, J.4    Beck, A.5    Smith, R.6
  • 8
    • 0031469250 scopus 로고    scopus 로고
    • Plateletapheresis: Comparison of processing times, platelet yields, and white blood cell content with several commonly used systems
    • DOI 10.1002/(SICI)1098-1101(1997)12:4<170::AID-JCA3>3.0.CO;2-7
    • Burgstaler EA, Pineda AA, Wollan P,. Plateletapheresis: comparison of processing times, platelet yields, and white blood cell content with several commonly used systems. J Clin Apher 1997; 12: 170-178. (Pubitemid 28035923)
    • (1997) Journal of Clinical Apheresis , vol.12 , Issue.4 , pp. 170-178
    • Burgstaler, E.A.1    Pineda, A.A.2    Wollan, P.3
  • 9
    • 33748289466 scopus 로고    scopus 로고
    • Prospective comparison of high-dose plateletpheresis with the latest apheresis systems on the same donors
    • DOI 10.1111/j.1537-2995.2006.00928.x
    • Picker SM, Radojska SM, Gathof BS,. Prospective comparison of high-dose plateletpheresis with the latest apheresis systems on the same donors. Transfusion 2006; 46: 1601-1608. (Pubitemid 44326338)
    • (2006) Transfusion , vol.46 , Issue.9 , pp. 1601-1608
    • Picker, S.M.1    Radojska, S.M.2    Gathof, B.S.3
  • 10
    • 0036939040 scopus 로고    scopus 로고
    • Concurrent collection of in-line filtered platelets and red blood cells by apheresis
    • DOI 10.1007/s00277-002-0463-6
    • Moog R, Bartsch R, Muller N,. Concurrent collection of in-line filtered platelets and red blood cells by apheresis. Ann Hematol 2002; 81: 322-325. (Pubitemid 36067630)
    • (2002) Annals of Hematology , vol.81 , Issue.6 , pp. 322-325
    • Moog, R.1    Bartsch, R.2    Muller, N.3
  • 11
    • 33744733046 scopus 로고    scopus 로고
    • Evaluation of concurrent collection of in-line filtered platelets and packed red blood cells by multicomponent apheresis with three last-generation apparatuses
    • DOI 10.1111/j.1423-0410.2006.00774.x
    • Picker SM, Radojska SM, Gathof BS,. Evaluation of concurrent collection of in-line filtered platelets and packed red blood cells by multicomponent apheresis with three last-generation apparatuses. Vox Sang 2006; 91: 47-55. (Pubitemid 43822304)
    • (2006) Vox Sanguinis , vol.91 , Issue.1 , pp. 47-55
    • Picker, S.M.1    Radojska, S.M.2    Gathof, B.S.3
  • 13
    • 0035159350 scopus 로고    scopus 로고
    • A prospective randomised concurrent comparison of the COBE Spectra Version 4.7, COBE Spectra Version 6 (auto PBSC™) and Haemonetics MCS+ cell separators for leucapheresis in patients with haematological and non-haematological malignancies
    • DOI 10.1016/S0955-3886(00)00131-4, PII S0955388600001314
    • Green RH, Watson D, Buchanan S, Morrison AE,. A prospective randomised concurrent comparison of the COBE Spectra Version 4.7, COBE Spectra Version 6 (auto PBSC) and Haemonetics MCS+ cell separators for leucapheresis in patients with haematological and non-haematological malignancies. Transfus Apher Sci 2001; 24: 85-90. (Pubitemid 33062331)
    • (2001) Transfusion and Apheresis Science , vol.24 , Issue.1 , pp. 85-90
    • Green, R.H.A.1    Watson, D.2    Buchanan, S.3    Morrison, A.E.4
  • 14
    • 0035165296 scopus 로고    scopus 로고
    • Cellular contamination of plasma collected with various apheresis systems
    • DOI 10.1016/S0955-3886(00)00128-4, PII S0955388600001284
    • Valbonesi M, Bruni R, Florio G, Zanella A, Bunkens H,. Cellular contamination of plasma collected with various apheresis systems. Transfus Apher Sci 2001; 24: 91-94. (Pubitemid 33062332)
    • (2001) Transfusion and Apheresis Science , vol.24 , Issue.1 , pp. 91-94
    • Valbonesi, M.1    Bruni, R.2    Florio, G.3    Zanella, A.4    Bunkens, H.5
  • 15
    • 33750143758 scopus 로고    scopus 로고
    • Blood component collection by apheresis
    • Burgstaler EA,. Blood component collection by apheresis. J Clin Apher 2006; 21: 142-151.
    • (2006) J Clin Apher , vol.21 , pp. 142-151
    • Burgstaler, E.A.1
  • 16
    • 0242440046 scopus 로고    scopus 로고
    • Residual cell content in plasma produced by three centrifugal apheresis procedures
    • DOI 10.1046/j.1537-2995.2003.00543.x
    • Burnouf T, Kappelsberger C, Frank K, Burkhardt T,. Residual cell content in plasma produced by three centrifugal apheresis procedures. Transfusion 2003; 43: 1522-1526. (Pubitemid 37371820)
    • (2003) Transfusion , vol.43 , Issue.11 , pp. 1522-1526
    • Burnouf, T.1    Kappelsberger, C.2    Frank, K.3    Burkhardt, T.4
  • 18
    • 0000719057 scopus 로고
    • Prediction of blood volume in normal human adults
    • Nadler SB, Hidalgo JU, Bloch T,. Prediction of blood volume in normal human adults. Invest Surg 1962; 51: 224-232.
    • (1962) Invest Surg , vol.51 , pp. 224-232
    • Nadler, S.B.1    Hidalgo, J.U.2    Bloch, T.3
  • 20
    • 79951755062 scopus 로고    scopus 로고
    • Patient and operator satisfaction with the Spectra Optia cell separator machine for plasma exchange: An initial single-center experience
    • Robertson S, McGarvey M, Sinclair JE, Taylor S, Douglas KW,. Patient and operator satisfaction with the Spectra Optia cell separator machine for plasma exchange: an initial single-center experience. J Clin Apher 2008; 23: 41-42.
    • (2008) J Clin Apher , vol.23 , pp. 41-42
    • Robertson, S.1    McGarvey, M.2    Sinclair, J.E.3    Taylor, S.4    Douglas, K.W.5