메뉴 건너뛰기




Volumn 44, Issue 1-3, 2011, Pages 411-430

Generalized calibration strategy in analytical chemistry

Author keywords

Accuracy; Analytical calibration; Flow injection analysis; Interference effect; Systematic errors

Indexed keywords


EID: 79951730501     PISSN: 00032719     EISSN: 1532236X     Source Type: Journal    
DOI: 10.1080/00032719.2010.500782     Document Type: Article
Times cited : (27)

References (47)
  • 1
    • 33847280313 scopus 로고    scopus 로고
    • Systematic error arising from "sequential" standard addition calibrations: Quantification and correction
    • Brown, R. J. C., M. R. Roberts, and M. J. T. Milton. 2007. Systematic error arising from "sequential" standard addition calibrations: Quantification and correction. Anal. Chim. Acta 587: 158-163.
    • (2007) Anal. Chim. Acta , vol.587 , pp. 158-163
    • Brown, R.J.C.1    Roberts, M.R.2    Milton, M.J.T.3
  • 2
    • 0022662522 scopus 로고
    • New technique in chemical assay calculations
    • Cardone, M. J. 1986. New technique in chemical assay calculations. Anal. Chem. 58: 433-435.
    • (1986) Anal. Chem. , vol.58 , pp. 433-435
    • Cardone, M.J.1
  • 3
    • 0034333408 scopus 로고    scopus 로고
    • Systematic errors: Detection and correction by means of standard calibration, Youden calibration and standard additions method in conjunction with a method response model
    • Castells, R. C., and M. A. Castillo. 2000. Systematic errors: Detection and correction by means of standard calibration, Youden calibration and standard additions method in conjunction with a method response model. Anal. Chim. Acta 423: 179-185.
    • (2000) Anal. Chim. Acta , vol.423 , pp. 179-185
    • Castells, R.C.1    Castillo, M.A.2
  • 4
    • 26744477362 scopus 로고
    • Flame photometric determination of calcium in sea water and marine organisms
    • Chow, T. J., and T. G. Thompson. 1955. Flame photometric determination of calcium in sea water and marine organisms. J. Anal. Chem. 27: 910-913.
    • (1955) J. Anal. Chem. , vol.27 , pp. 910-913
    • Chow, T.J.1    Thompson, T.G.2
  • 9
    • 79951755452 scopus 로고    scopus 로고
    • FIA strategies for calibration and standardization in atomic spectrometry
    • ed. A. Sanz-Mendel. Amsterdam: Elsevier
    • De la Guardia, M. 1999. FIA strategies for calibration and standardization in atomic spectrometry. In Flow analysis with atomic spectrometric detectors, ed. A. Sanz-Mendel. Amsterdam: Elsevier.
    • (1999) Flow Analysis with Atomic Spectrometric Detectors
    • de la Guardia, M.1
  • 10
    • 0011354286 scopus 로고
    • New York/Toronto/London: McGraw-Hill
    • Dean, J. A. 1960. Flame photometry. New York/Toronto/London: McGraw-Hill.
    • (1960) Flame Photometry
    • Dean, J.A.1
  • 12
    • 0345059188 scopus 로고    scopus 로고
    • Effect of different matrices on physiological amino acids analysis by liquid chromatography: Evaluation and correction of the matrix effect
    • Fernández-Figares, I., L. Cuadros-Rodriguez, and A. González-Casado. 2004. Effect of different matrices on physiological amino acids analysis by liquid chromatography: Evaluation and correction of the matrix effect. J. Chromatogr. B 799: 73-79.
    • (2004) J. Chromatogr. B , vol.799 , pp. 73-79
    • Fernández-Figares, I.1    Cuadros-Rodriguez, L.2    González-Casado, A.3
  • 13
    • 0009356475 scopus 로고
    • Optimizing precision in standard additions determinations
    • Gardner, M. J., and A. M. Gunn. 1986. Optimizing precision in standard additions determinations. Fresenius Z. Anal. Chem. 325: 263-266.
    • (1986) Fresenius Z. Anal. Chem. , vol.325 , pp. 263-266
    • Gardner, M.J.1    Gunn, A.M.2
  • 14
    • 26344448228 scopus 로고
    • Determination of cadmium by flame photometry
    • Gilbert, P. T. 1959. Determination of cadmium by flame photometry. J. Anal. Chem. 31: 110-114.
    • (1959) J. Anal. Chem. , vol.31 , pp. 110-114
    • Gilbert, P.T.1
  • 15
    • 34247614419 scopus 로고    scopus 로고
    • Verification of results to improve the quality of analytical data: A proposal
    • Grob, K. 2007. Verification of results to improve the quality of analytical data: A proposal. J. Chromatogr. A 1150: 93-99.
    • (2007) J. Chromatogr. A , pp. 93-99
    • Grob, K.1
  • 16
    • 33745160431 scopus 로고    scopus 로고
    • An expression of uncertainty in calibration using stepwise or separate dilution of a stock solution
    • Hayashi, Y., and R. Matsuda. 2006. An expression of uncertainty in calibration using stepwise or separate dilution of a stock solution. Anal. Sci. 22: 889-894.
    • (2006) Anal. Sci. , vol.22 , pp. 889-894
    • Hayashi, Y.1    Matsuda, R.2
  • 17
    • 77952173244 scopus 로고    scopus 로고
    • A flow method with spectrophotometric detection for determination of chlorite ions in drinking water
    • Herman, M., P. Kościelniak, M. Wieczorek, M. Stafiński, and M. Matuszek. 2009. A flow method with spectrophotometric detection for determination of chlorite ions in drinking water. Chem. Anal. (Warsaw) 54: 907-919.
    • (2009) Chem. Anal. (Warsaw) , vol.54 , pp. 907-919
    • Herman, M.1    Kościelniak, P.2    Wieczorek, M.3    Stafiński, M.4    Matuszek, M.5
  • 19
    • 33845279167 scopus 로고
    • Are quality and productivity compatible in the analytical laboratory?
    • Hertz, H. S. 1988. Are quality and productivity compatible in the analytical laboratory? Anal. Chem. 60: 75A-80A.
    • (1988) Anal. Chem. , vol.60
    • Hertz, H.S.1
  • 20
    • 0343414539 scopus 로고    scopus 로고
    • Nonlinear calibration by the standard addition method
    • Kościelniak, P. 1999. Nonlinear calibration by the standard addition method. Chemom. Intell. Lab. Syst. 47: 275-287.
    • (1999) Chemom. Intell. Lab. Syst. , vol.47 , pp. 275-287
    • Kościelniak, P.1
  • 21
    • 0035800130 scopus 로고    scopus 로고
    • Univariate calibration techniques in flow injection analysis
    • Kościelniak, P. 2001. Univariate calibration techniques in flow injection analysis. Anal. Chim. Acta 438: 323-333.
    • (2001) Anal. Chim. Acta , vol.438 , pp. 323-333
    • Kościelniak, P.1
  • 22
    • 79951742808 scopus 로고    scopus 로고
    • Advanced calibration methods in flow injection analysis
    • ed. M. Trojanowicz. Weinheim: Wiley-VCH
    • Kościelniak, P. 2008. Advanced calibration methods in flow injection analysis. In Advances in flow analysis, ed. M. Trojanowicz. Weinheim: Wiley-VCH.
    • (2008) Advances in Flow Analysis
    • Kościelniak, P.1
  • 23
    • 17144474574 scopus 로고    scopus 로고
    • A new approach to the integrated calibration in flow injection analysis
    • Kościelniak, P., G. Akcin, M. Herman, J. Kozak, and M. Wieczorek. 2003. A new approach to the integrated calibration in flow injection analysis. Ann. Chim. 903: 1045-1058.
    • (2003) Ann. Chim. , vol.903 , pp. 1045-1058
    • Kościelniak, P.1    Akcin, G.2    Herman, M.3    Kozak, J.4    Wieczorek, M.5
  • 24
    • 0037024285 scopus 로고    scopus 로고
    • Calibration by the gradient ratio-standard addition method in flow injection flame atomic absorption spectrometry
    • Kościelniak, P., and J. Kozak. 2002. Calibration by the gradient ratio-standard addition method in flow injection flame atomic absorption spectrometry. Anal. Chim. Acta 460: 235-245.
    • (2002) Anal. Chim. Acta , vol.460 , pp. 235-245
    • Kościelniak, P.1    Kozak, J.2
  • 25
    • 1842533321 scopus 로고    scopus 로고
    • Review and classification of univariate interpolative calibration procedures in flow analysis
    • Kościelniak, P., and J. Kozak. 2004. Review and classification of univariate interpolative calibration procedures in flow analysis. Crit. Rev. Anal. Chem. 34: 25-37. (B)
    • (2004) Crit. Rev. Anal. Chem. , vol.34 , Issue.B , pp. 25-37
    • Kościelniak, P.1    Kozak, J.2
  • 26
    • 32644478079 scopus 로고    scopus 로고
    • Review of univariate standard addition calibration procedures in flow analysis
    • Kościelniak, P., and J. Kozak. 2006. Review of univariate standard addition calibration procedures in flow analysis. Crit. Rev. Anal. Chem. 36: 27-40.
    • (2006) Crit. Rev. Anal. Chem. , vol.36 , pp. 27-40
    • Kościelniak, P.1    Kozak, J.2
  • 27
    • 2442680432 scopus 로고    scopus 로고
    • Complementary dilution method - a new version of calibration by integrated strategy
    • Kościelniak, P., J. Kozak, M. Herman, M. Wieczorek, and A. Fudalik. 2004. Complementary dilution method - a new version of calibration by integrated strategy. Anal. Lett. 37: 1233-1253. (A).
    • (2004) Anal. Lett. , vol.37 , Issue.A , pp. 1233-1253
    • Kościelniak, P.1    Kozak, J.2    Herman, M.3    Wieczorek, M.4    Fudalik, A.5
  • 28
    • 0347874889 scopus 로고    scopus 로고
    • High efficient calibration procedure for flow injection flame atomic absorption spectrometry
    • Kościelniak, P., M. Sperling, and B. Welz. 1996. High efficient calibration procedure for flow injection flame atomic absorption spectrometry. Chem. Anal. (Warsaw) 41: 587-600.
    • (1996) Chem. Anal. (Warsaw) , vol.41 , pp. 587-600
    • Kościelniak, P.1    Sperling, M.2    Welz, B.3
  • 29
    • 0010385561 scopus 로고
    • Calibration in flame atomic absorption spectrometry by the methods of successive sample dilution with the use of spectra buffers
    • Kościelniak, P., and S. Walas. 1993. Calibration in flame atomic absorption spectrometry by the methods of successive sample dilution with the use of spectra buffers. Univ. Jagiell. Acta Chim. 36: 53-59.
    • (1993) Univ. Jagiell. Acta Chim. , vol.36 , pp. 53-59
    • Kościelniak, P.1    Walas, S.2
  • 30
    • 75849154693 scopus 로고    scopus 로고
    • Extrapolative version of the indirect calibration method
    • Kościelniak, P., and M. Wieczorek. 2010. Extrapolative version of the indirect calibration method. Anal. Lett. 43: 424-435.
    • (2010) Anal. Lett. , vol.43 , pp. 424-435
    • Kościelniak, P.1    Wieczorek, M.2
  • 31
  • 32
    • 0040018717 scopus 로고    scopus 로고
    • Fast determination of calcium, magnesium and zinc in honey using continuous flow flame atomic absorption spectrometry
    • López-García, I., P. Viñas, M. Hernández-Córdoba, and C. Blanco. 1999. Fast determination of calcium, magnesium and zinc in honey using continuous flow flame atomic absorption spectrometry. Talanta 49: 597-602.
    • (1999) Talanta , vol.49 , pp. 597-602
    • López-García, I.1    Viñas, P.2    Hernández-Córdoba, M.3    Blanco, C.4
  • 33
    • 0034740678 scopus 로고    scopus 로고
    • Peristaltic pumps and Fourier transforms in flame atomic absorption spectrometry: Use of standard additions method and on-line dilution procedures
    • López-Garcia, I., M. Sánchez-Merlos, P. Viñas, and M. Hernández-Córdoba. 2001. Peristaltic pumps and Fourier transforms in flame atomic absorption spectrometry: Use of standard additions method and on-line dilution procedures. J. Atom. Abs. Spect. 16: 1185-1189.
    • (2001) J. Atom. Abs. Spect. , vol.16 , pp. 1185-1189
    • López-Garcia, I.1    Sánchez-Merlos, M.2    Viñas, P.3    Hernández-Córdoba, M.4
  • 34
    • 1842367579 scopus 로고
    • Quantitative analysis of hydrocarbons in gasolines by capillary gas-liquid chromatography
    • Matisová, E., J. Krupčik, P. Čellar, and J. Garaj. 1984. Quantitative analysis of hydrocarbons in gasolines by capillary gas-liquid chromatography. J.Chromatogr. 303: 151-163.
    • (1984) J.Chromatogr. , vol.303 , pp. 151-163
    • Matisová, E.1    Krupčik, J.2    Čellar, P.3    Garaj, J.4
  • 35
    • 0035218620 scopus 로고    scopus 로고
    • Detection and correction of interferences in spectroscopy techniques
    • Mauri, A. R., M. Llobat, and D. Adriá. 2001. Detection and correction of interferences in spectroscopy techniques. Anal. Chim. Acta 426: 135-146.
    • (2001) Anal. Chim. Acta. , vol.426 , pp. 135-146
    • Mauri, A.R.1    Llobat, M.2    Adriá, D.3
  • 36
    • 0010380725 scopus 로고
    • The standard addition and successive dilution method for evaluation and verification of results in atomic-absorption analysis
    • Pszonicki, L., and W. Skwara. 1989. The standard addition and successive dilution method for evaluation and verification of results in atomic-absorption analysis. Talanta 36: 1265-1276.
    • (1989) Talanta , vol.36 , pp. 1265-1276
    • Pszonicki, L.1    Skwara, W.2
  • 38
    • 49849110633 scopus 로고
    • A critical analysis of the method of successive dilutions in photometry
    • Shatkay, A. 1970. A critical analysis of the method of successive dilutions in photometry. Anal. Chim. Acta 52: 547-550.
    • (1970) Anal. Chim. Acta , vol.52 , pp. 547-550
    • Shatkay, A.1
  • 39
    • 0342468277 scopus 로고    scopus 로고
    • Standard additions in flow injection analysis based on merging zones and gradient exploitation: Application to copper determination in spirits
    • Silva, E. C., M. C. U. Araújo, R. S. Honorato, J. L. F. Costa Lima, E. A. G. Zagatto, and S. M. Boscolo Brienza. 1996. Standard additions in flow injection analysis based on merging zones and gradient exploitation: Application to copper determination in spirits. Anal. Chim. Acta 319: 153-158.
    • (1996) Anal. Chim. Acta , vol.319 , pp. 153-158
    • Silva, E.C.1    Araújo, M.C.U.2    Honorato, R.S.3    Costa Lima, J.L.F.4    Zagatto, E.A.G.5    Boscolo Brienza, S.M.6
  • 40
    • 0000691869 scopus 로고
    • Expansion of dynamic working range and correction for interferences in flame atomic absorption spectrometry using flow-injection gradient ratio calibration with a single standard
    • Sperling, M., Z. Fang, and B. Welz. 1991. Expansion of dynamic working range and correction for interferences in flame atomic absorption spectrometry using flow-injection gradient ratio calibration with a single standard. Anal. Chem. 63: 151-159.
    • (1991) Anal. Chem. , vol.63 , pp. 151-159
    • Sperling, M.1    Fang, Z.2    Welz, B.3
  • 43
    • 15044340104 scopus 로고    scopus 로고
    • A review of interference effects and their correction in chemical analysis with special reference to uncertainty
    • Thompson, M., and S. L. R. Ellison. 2005. A review of interference effects and their correction in chemical analysis with special reference to uncertainty. Accred. Qual. Assur. 10: 82-97.
    • (2005) Accred. Qual. Assur. , vol.10 , pp. 82-97
    • Thompson, M.1    Ellison, S.L.R.2
  • 44
    • 0000267218 scopus 로고
    • Flow injection sample processing in atomic absorption spectrometry
    • Trojanowicz, M., and E. Olbrych-Śleszyńska. 1992. Flow injection sample processing in atomic absorption spectrometry. Chem. Anal. (Warsaw) 37: 111-138.
    • (1992) Chem. Anal. (Warsaw) , vol.37 , pp. 111-138
    • Trojanowicz, M.1    Olbrych-Śleszyńska, E.2
  • 45
    • 0001573038 scopus 로고
    • Flow injection calibration techniques
    • Tyson, J. F. 1991. Flow injection calibration techniques. Spect. Acta Rev. 14: 169-233.
    • (1991) Spect. Acta Rev. , vol.14 , pp. 169-233
    • Tyson, J.F.1
  • 47
    • 0003088059 scopus 로고
    • Abuse of the analyte addition technique in atomic absorption spectrometry
    • Welz, B. 1986. Abuse of the analyte addition technique in atomic absorption spectrometry. Fresenius Z. Anal. Chem. 325: 95-101.
    • (1986) Fresenius Z. Anal. Chem. , vol.325 , pp. 95-101
    • Welz, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.