메뉴 건너뛰기




Volumn 166, Issue 1, 2011, Pages 88-93

Characterization of electroosmotic pumps using methanol/water mixtures with various compositions

Author keywords

Direct methanol fuel cell (DMFC); Electroosmotic pump; Porous glass; Water methanol mixture pumping

Indexed keywords

APPLIED VOLTAGES; ELECTROOSMOTIC PUMP; ELECTROOSMOTIC PUMPS; LINEAR DEPENDENCY; MAXIMUM FLOW RATE; MAXIMUM PRESSURE; METHANOL CONCENTRATION; METHANOL/WATER MIXTURES; NONLINEAR DEPENDENCIES; NORMALIZED PARAMETERS; PERFORMANCE PARAMETERS; POROUS GLASS; PUMP MODELS; PURE WATER; VOLTAGE CHANGE; WATER/METHANOL MIXTURE;

EID: 79951680856     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2010.12.016     Document Type: Article
Times cited : (4)

References (54)
  • 1
    • 59649095263 scopus 로고    scopus 로고
    • Electroosmotic pumps and their applications in microfluidic systems
    • X. Wang, C. Cheng, S. Wang, and S. Liu Electroosmotic pumps and their applications in microfluidic systems Microfluid. Nanofluid. 6 2009 145 162
    • (2009) Microfluid. Nanofluid. , vol.6 , pp. 145-162
    • Wang, X.1    Cheng, C.2    Wang, S.3    Liu, S.4
  • 2
    • 0242469013 scopus 로고    scopus 로고
    • Porous glass electroosmotic pumps: Theory
    • DOI 10.1016/S0021-9797(03)00731-8
    • S.H. Yao, and J.G. Santiago Porous glass electroosmotic pumps: theory J. Colloid Interface Sci. 268 2003 133 142 (Pubitemid 37377992)
    • (2003) Journal of Colloid and Interface Science , vol.268 , Issue.1 , pp. 133-142
    • Yao, S.1    Santiago, J.G.2
  • 3
    • 0002126213 scopus 로고    scopus 로고
    • Electrokinetic generation of high pressures using porous microstructures
    • P.H. Paul, D.W. Arnold, and D.J. Rakestraw Electrokinetic generation of high pressures using porous microstructures D.J. Harrison, A. Berg, Micro Total Analysis System 1998 Springer New York 49 52
    • (1998) Micro Total Analysis System , pp. 49-52
    • Paul, P.H.1    Arnold, D.W.2    Rakestraw, D.J.3
  • 4
    • 0035888368 scopus 로고    scopus 로고
    • Fabrication and characterization of electroosmotic micropumps
    • DOI 10.1016/S0925-4005(01)00855-3, PII S0925400501008553
    • S. Zeng, C.H. Chen, J.C. Mikkelsen, and J.G. Santiago Fabrication and characterization of electroosmotic micropumps Sens. Actuators B: Chem. 79 2001 107 114 (Pubitemid 32866875)
    • (2001) Sensors and Actuators, B: Chemical , vol.79 , Issue.2-3 , pp. 107-114
    • Zeng, S.1    Chen, C.-H.2    Mikkelsen Jr., J.C.3    Santiago, J.G.4
  • 5
    • 44649157052 scopus 로고    scopus 로고
    • Development of an electroosmotic pump using nanosilica particle packed capillary
    • DOI 10.1109/JSEN.2008.918726, 4529131
    • L. Chen, Q. Li, S. Lee, and J. Choo Development of an electroosmotic pump using nanosilica particle packed capillary IEEE Sens. J. 8 2008 488 494 (Pubitemid 351780229)
    • (2008) IEEE Sensors Journal , vol.8 , Issue.5 , pp. 488-494
    • Chen, L.1    Li, Q.2    Lee, S.3    Choo, J.4
  • 6
    • 41549093279 scopus 로고    scopus 로고
    • High pressure electroosmotic pump based on a packed bed planar microchip
    • DOI 10.1016/j.snb.2007.11.030, PII S0925400507009604
    • J. Borowsky, Q. Lu, and G.E. Collins High pressure electroosmotic based on a packed bed planar microchip Sens. Actuators B: Chem. 131 2008 333 339 (Pubitemid 351467742)
    • (2008) Sensors and Actuators, B: Chemical , vol.131 , Issue.1 , pp. 333-339
    • Borowsky, J.1    Lu, Q.2    Collins, G.E.3
  • 9
    • 36348936184 scopus 로고    scopus 로고
    • High flow rate per power electroosmotic pumping using low ion density solvents
    • DOI 10.1016/j.sna.2007.07.023, PII S0924424707005730
    • D. Kim, J.D. Posner, and J.G. Santiago High flow rate per power electroosmotic pumping using low ion density solvents Sens. Actuators A: Phys. 141 2008 201 212 (Pubitemid 350151731)
    • (2008) Sensors and Actuators, A: Physical , vol.141 , Issue.1 , pp. 201-212
    • Kim, D.1    Posner, J.D.2    Santiago, J.G.3
  • 12
    • 29244436869 scopus 로고    scopus 로고
    • Characterization and manipulation of the electroosmotic flow in porous anodic alumina membranes
    • DOI 10.1021/ac0513055
    • W. Chen, J.H. Yuan, and X.H. Xia Characterization and manipulation of the electroosmotic flow in porous anodic alumina membranes Anal. Chem. 77 2005 8102 8108 (Pubitemid 41831997)
    • (2005) Analytical Chemistry , vol.77 , Issue.24 , pp. 8102-8108
    • Chen, W.1    Yuan, J.-H.2    Xia, X.-H.3
  • 14
    • 46949085485 scopus 로고    scopus 로고
    • Low-voltage electroosmotic pumping using porous anodic alumina membranes
    • Y.F. Chen, M.C. Li, Y.H. Hu, W.J. Chang, and C.C. Wang Low-voltage electroosmotic pumping using porous anodic alumina membranes Microfluid. Nanofluid. 5 2008 235 244
    • (2008) Microfluid. Nanofluid. , vol.5 , pp. 235-244
    • Chen, Y.F.1    Li, M.C.2    Hu, Y.H.3    Chang, W.J.4    Wang, C.C.5
  • 15
    • 76949106087 scopus 로고    scopus 로고
    • Surface modification of nano-porous anodic alumina membranes and its use in electroosmotic flow
    • Y.F. Chen, Y.H. Hu, Y.I. Chou, S.M. Lai, and C.C. Wang Surface modification of nano-porous anodic alumina membranes and its use in electroosmotic flow Sens. Actuators B: Chem. 145 2010 572 582
    • (2010) Sens. Actuators B: Chem. , vol.145 , pp. 572-582
    • Chen, Y.F.1    Hu, Y.H.2    Chou, Y.I.3    Lai, S.M.4    Wang, C.C.5
  • 17
    • 0026706179 scopus 로고
    • Flow injection analysis in the capillary format using electroosmotic pumping
    • S. Liu, and P.K. Dasgupta Flow injection analysis in the capillary format using electroosmotic pumping Anal. Chim. Acta 268 1992 1 6
    • (1992) Anal. Chim. Acta , vol.268 , pp. 1-6
    • Liu, S.1    Dasgupta, P.K.2
  • 18
    • 0027423336 scopus 로고
    • A simple means to increase absorbance detection sensitivity in capillary zone electrophoresis
    • DOI 10.1016/0003-2670(93)85289-V
    • S. Liu, and P.K. Dasgupta A simple means to increase absorbance detection sensitivity in capillary zone electrophoresis Anal. Chim. Acta 283 1993 747 753 (Pubitemid 23345815)
    • (1993) Analytica Chimica Acta , vol.283 , Issue.2 , pp. 747-753
    • Liu, S.1    Dasgupta, P.K.2
  • 19
    • 4243836329 scopus 로고
    • Electroosmosis: A reliable fluid propulsion system for flow injection analysis
    • P.K. Dasgupta, and S. Liu Electroosmosis: a reliable fluid propulsion system for flow injection analysis Anal. Chem. 66 1994 1792 1798
    • (1994) Anal. Chem. , vol.66 , pp. 1792-1798
    • Dasgupta, P.K.1    Liu, S.2
  • 20
    • 0005600384 scopus 로고
    • Sequential injection analysis in capillary format with an electroosmotic pump
    • S. Liu, and P.K. Dasgupta Sequential injection analysis in capillary format with an electroosmotic pump Talanta 41 1994 1903 1910
    • (1994) Talanta , vol.41 , pp. 1903-1910
    • Liu, S.1    Dasgupta, P.K.2
  • 21
    • 0029000454 scopus 로고
    • Electroosmotically pumped capillary format sequential injection analysis with a membrane sampling interface for gaseous analytes
    • S. Liu, and P.K. Dasgupta Electroosmotically pumped capillary format sequential injection analysis with a membrane sampling interface for gaseous analytes Anal. Chim. Acta 308 1995 281 285
    • (1995) Anal. Chim. Acta , vol.308 , pp. 281-285
    • Liu, S.1    Dasgupta, P.K.2
  • 22
    • 0034599456 scopus 로고    scopus 로고
    • Mechanism of porous core electroosmotic pump flow injection system and its application to determination of chromium (VI) in waste-water
    • W. Gan, L. Yang, Y. He, R. Zeng, M.L. Cervera, and M. de la Guardia Mechanism of porous core electroosmotic pump flow injection system and its application to determination of chromium (VI) in waste-water Talanta 51 2000 667 675
    • (2000) Talanta , vol.51 , pp. 667-675
    • Gan, W.1    Yang, L.2    He, Y.3    Zeng, R.4    Cervera, M.L.5    De La Guardia, M.6
  • 23
    • 0035974976 scopus 로고    scopus 로고
    • Determination of chromium(VI) and lead(II) in drinking water by electrokinetic flow analysis system and graphite furnace atomic absorption spectrometry
    • DOI 10.1016/S0039-9140(01)00424-6, PII S0039914001004246
    • L. Yang, Y.Z. He, W.E. Gan, M. Li, Q.S. Qu, and X.Q. Lin Determination of chromium (VI) and lead (II) in drinking water by electrokinetic flow analysis system and graphite furnace atomic absorption spectrometry Talanta 55 2001 271 279 (Pubitemid 32756718)
    • (2001) Talanta , vol.55 , Issue.2 , pp. 271-279
    • Yang, L.1    He, Y.-Z.2    Gan, W.-E.3    Li, M.4    Qu, Q.-S.5    Lin, X.-Q.6
  • 24
    • 0037061142 scopus 로고    scopus 로고
    • Determination of nitrite by sequential injection analysis of electrokinetic flow analysis system
    • DOI 10.1016/S0039-9140(01)00624-5, PII S0039914001006245
    • Y.Q. Zhao, Y.Z. He, W.E. Gan, and L. Yang Determination of nitrite by sequential injection analysis using electrokinetic flow analysis system Talanta 6 2002 619 625 (Pubitemid 34203186)
    • (2002) Talanta , vol.56 , Issue.4 , pp. 619-625
    • Zhao, Y.-Q.1    He, Y.-Z.2    Gan, W.-E.3    Yang, L.4
  • 25
    • 0002689971 scopus 로고
    • Electro-osmosis: A new concept for high-speed chromatography
    • V. Pretorius, B.J. Hopkins, and J.D. Schieke Electro-osmosis: a new concept for high-speed chromatography J. Chromatogr. A 99 1974 23 30
    • (1974) J. Chromatogr. A , vol.99 , pp. 23-30
    • Pretorius, V.1    Hopkins, B.J.2    Schieke, J.D.3
  • 26
    • 0043207695 scopus 로고    scopus 로고
    • An electroosmotic pump for packed capillary liquid chromatography
    • L. Chen, J. Ma, and Y. Guan An electroosmotic pump for packed capillary liquid chromatography Microchem. J. 75 2003 15 21
    • (2003) Microchem. J. , vol.75 , pp. 15-21
    • Chen, L.1    Ma, J.2    Guan, Y.3
  • 27
    • 1642473023 scopus 로고    scopus 로고
    • Study of an electroosmotic pump for liquid delivery and its application in capillary column liquid chromatography
    • DOI 10.1016/j.chroma.2003.11.071
    • L. Chen, J. Ma, and Y. Guan Study of an electroosmotic pump for liquid delivery and its application in capillary column liquid chromatography J. Chromatogr. A. 1028 2004 219 226 (Pubitemid 38121367)
    • (2004) Journal of Chromatography A , vol.1028 , Issue.2 , pp. 219-226
    • Chen, L.1    Ma, J.2    Guan, Y.3
  • 28
    • 33746784676 scopus 로고    scopus 로고
    • Microfluidic liquid chromatography system for proteomic applications and biomarker screening
    • DOI 10.1021/ac060434y
    • I.M. Lazar, P. Trisiripisal, and H.A. Sarvaiya Microfluidic liquid chromatography system for proteomic applications and biomarker screening Anal. Chem. 78 2006 5513 5524 (Pubitemid 44182372)
    • (2006) Analytical Chemistry , vol.78 , Issue.15 , pp. 5513-5524
    • Lazar, I.M.1    Trisiripisal, P.2    Sarvaiya, H.A.3
  • 29
    • 55549104034 scopus 로고    scopus 로고
    • Electroosmotic flow-based pump for liquid chromatography on a planar microchip
    • J. Borowsky, B. Giordano, Q. Lu, and G.E. Collins Electroosmotic flow-based pump for liquid chromatography on a planar microchip Anal. Chem. 80 2008 8287 8292
    • (2008) Anal. Chem. , vol.80 , pp. 8287-8292
    • Borowsky, J.1    Giordano, B.2    Lu, Q.3    Collins, G.E.4
  • 32
    • 72049106141 scopus 로고    scopus 로고
    • Microfluidic system integrated electroosmotic pumps, concentration gradient generator and fish cell line (RTgill-W1)-towards water toxicity testing
    • T. Glawdel, C. Elvuken, L.E.J. Lee, and C.L. Ren Microfluidic system integrated electroosmotic pumps, concentration gradient generator and fish cell line (RTgill-W1)-towards water toxicity testing Lab Chip 9 2009 3243 3250
    • (2009) Lab Chip , vol.9 , pp. 3243-3250
    • Glawdel, T.1    Elvuken, C.2    Lee, L.E.J.3    Ren, C.L.4
  • 33
    • 60049098753 scopus 로고    scopus 로고
    • Electro-osmotic flow control for living cell analysis in microfluidic PDMS chips
    • T. Glawdel, and C.L. Ren Electro-osmotic flow control for living cell analysis in microfluidic PDMS chips Mech. Res. Commun. 36 2009 75 81
    • (2009) Mech. Res. Commun. , vol.36 , pp. 75-81
    • Glawdel, T.1    Ren, C.L.2
  • 34
    • 33748960401 scopus 로고    scopus 로고
    • Water management in proton exchange membrane fuel cells using integrated electroosmotic pumping
    • DOI 10.1016/j.jpowsour.2006.03.021, PII S0378775306004654
    • C.R. Buie, J.D. Posner, T. Fabian, S.W. Cha, D. Kim, F.B. Prinz, J.K. Eaton, and J.G. Santiago Water management in proton exchange membrane fuel cells using integrated electroosmotic pumping J. Power Sources 161 2006 191 202 (Pubitemid 44442729)
    • (2006) Journal of Power Sources , vol.161 , Issue.1 , pp. 191-202
    • Buie, C.R.1    Posner, J.D.2    Fabian, T.3    Cha, S.-W.4    Kim, D.5    Prinz, F.B.6    Eaton, J.K.7    Santiago, J.G.8
  • 35
    • 69249124564 scopus 로고    scopus 로고
    • Engineering model for coupling wicks and electroosmotic pumps with proton exchange membrane fuel cells for active water management
    • S. Litster, C.R. Buie, and J.G. Santiago Engineering model for coupling wicks and electroosmotic pumps with proton exchange membrane fuel cells for active water management Electrochim. Acta 54 2009 6223 6233
    • (2009) Electrochim. Acta , vol.54 , pp. 6223-6233
    • Litster, S.1    Buie, C.R.2    Santiago, J.G.3
  • 36
    • 75749107380 scopus 로고    scopus 로고
    • Active water management at the cathode of a planar air-breathing polymer electrolyte membrane fuel cell an electroosmotic pump
    • T. Fabian, R. O'Hayre, S. Litster, F.B. Prinz, and J.G. Santiago Active water management at the cathode of a planar air-breathing polymer electrolyte membrane fuel cell an electroosmotic pump J. Power Sources 195 2010 3640 3644
    • (2010) J. Power Sources , vol.195 , pp. 3640-3644
    • Fabian, T.1    O'Hayre, R.2    Litster, S.3    Prinz, F.B.4    Santiago, J.G.5
  • 38
    • 33750947996 scopus 로고    scopus 로고
    • Power sources compared: The ultimate truth?
    • DOI 10.1016/j.jpowsour.2005.07.007, PII S0378775305008517
    • S.F.J. Flipsen Power sources compared: the ultimate truth? J. Power Sources 162 2006 927 934 (Pubitemid 44738341)
    • (2006) Journal of Power Sources , vol.162 , Issue.2 SPEC. ISSUE , pp. 927-934
    • Flipsen, S.F.J.1
  • 39
    • 0347355055 scopus 로고    scopus 로고
    • Development and characterization of a silicon-based micro direct methanol fuel cell
    • G.Q. Lu, C.Y. Wang, T.J. Yen, and X. Zhang Development and characterization of a silicon-based micro direct methanol fuel cell Electrochim. Acta 49 2004 821 828
    • (2004) Electrochim. Acta , vol.49 , pp. 821-828
    • Lu, G.Q.1    Wang, C.Y.2    Yen, T.J.3    Zhang, X.4
  • 40
    • 18844363197 scopus 로고    scopus 로고
    • Development of micro direct methanol fuel cells for high power applications
    • G.Q. Lu, and C.Y. Wang Development of micro direct methanol fuel cells for high power applications J. Power Sources 144 2005 141 145
    • (2005) J. Power Sources , vol.144 , pp. 141-145
    • Lu, G.Q.1    Wang, C.Y.2
  • 41
    • 33645729428 scopus 로고    scopus 로고
    • A review of anode catalysis in the direct methanol fuel cell
    • H. Liu, C. Song, L. Zhang, H. Wang, and D.P. Wilkinson A review of anode catalysis in the direct methanol fuel cell J. Power Sources 155 2006 95 110
    • (2006) J. Power Sources , vol.155 , pp. 95-110
    • Liu, H.1    Song, C.2    Zhang, L.3    Wang, H.4    Wilkinson, D.P.5
  • 42
    • 69449105383 scopus 로고    scopus 로고
    • Experimental investigation of current distribution in a direct methanol fuel cell with serpentine flow-fields under various operating conditions
    • S.M. Park, S.K. Kim, S. Lim, D.H. Jung, D.H. Peck, and W.H. Hong Experimental investigation of current distribution in a direct methanol fuel cell with serpentine flow-fields under various operating conditions J. Power Sources 194 2009 818 823
    • (2009) J. Power Sources , vol.194 , pp. 818-823
    • Park, S.M.1    Kim, S.K.2    Lim, S.3    Jung, D.H.4    Peck, D.H.5    Hong, W.H.6
  • 43
  • 44
    • 65649105899 scopus 로고    scopus 로고
    • Small direct methanol fuel cells with passive supply of reactants
    • T.S. Zhao, R. Chen, W.W. Yang, and C. Xu Small direct methanol fuel cells with passive supply of reactants J. Power Sources 191 2009 185 202
    • (2009) J. Power Sources , vol.191 , pp. 185-202
    • Zhao, T.S.1    Chen, R.2    Yang, W.W.3    Xu, C.4
  • 45
    • 0032664412 scopus 로고    scopus 로고
    • Carbon dioxide evolution patterns in direct methanol fuel cells
    • P. Argyropoulos, K. Scott, and W.M. Taama Carbon dioxide evolution patterns in direct methanol fuel cells Electrochim. Acta 44 1999 3575 3584
    • (1999) Electrochim. Acta , vol.44 , pp. 3575-3584
    • Argyropoulos, P.1    Scott, K.2    Taama, W.M.3
  • 46
    • 4344599218 scopus 로고    scopus 로고
    • Development of a 2W direct methanol fuel cell power source
    • C. Xie, J. Bostaph, and J. Pavio Development of a 2W direct methanol fuel cell power source J. Power Sources 136 2004 55 65
    • (2004) J. Power Sources , vol.136 , pp. 55-65
    • Xie, C.1    Bostaph, J.2    Pavio, J.3
  • 47
    • 25644437021 scopus 로고    scopus 로고
    • Transient capillary blocking in the flow field of a micro-DMFC and its effect on cell performance
    • C.W. Wang, T.S. Zhao, and J.G. Liu Transient capillary blocking in the flow field of a micro-DMFC and its effect on cell performance J. Electrochem. Soc. 152 2005 A1600 A1605
    • (2005) J. Electrochem. Soc. , vol.152
    • Wang, C.W.1    Zhao, T.S.2    Liu, J.G.3
  • 48
    • 10644228456 scopus 로고    scopus 로고
    • Valveless piezoelectric micropump for fuel delivery in direct methanol fuel cell (DMFC) devices
    • DOI 10.1016/j.jpowsour.2004.07.026
    • T. Zhang, and Q.M. Wang Valveless piezoelectric micropump for fuel delivery in direct methanol fuel cell (DMFC) devices J. Power Sources 140 2005 72 80 (Pubitemid 40020392)
    • (2005) Journal of Power Sources , vol.140 , Issue.1 , pp. 72-80
    • Zhang, T.1    Wang, Q.-M.2
  • 49
    • 33745005044 scopus 로고    scopus 로고
    • Performance of miniaturized direct methanol fuel cell (DMFC) devices using micropump for fuel delivery
    • DOI 10.1016/j.jpowsour.2005.06.043, PII S0378775305013856
    • T. Zhang, and Q.M. Wang Performance of miniaturized direct methnol fuel cell (DMFC) devices using micropump for fuel delivery J. Power Sources 158 2006 169 176 (Pubitemid 43868030)
    • (2006) Journal of Power Sources , vol.158 , Issue.1 , pp. 169-176
    • Zhang, T.1    Wang, Q.-M.2
  • 50
    • 13844256391 scopus 로고    scopus 로고
    • The efficiency of electrokinetic pumping at a condition of maximum work
    • DOI 10.1002/elps.200406169
    • S.K. Griffiths, and R.H. Nilson The efficiency of electrokinetic pumping at a condition of maximum work Electrophoresis 26 2005 351 361 (Pubitemid 40253788)
    • (2005) Electrophoresis , vol.26 , Issue.2 , pp. 351-361
    • Griffiths, S.K.1    Nilson, R.H.2
  • 52
    • 0030612552 scopus 로고    scopus 로고
    • Behavior and use of nonaqueous media without supporting electrolyte in capillary electrophoresis and capillary electrochromatography
    • P.B. Wright, A.S. Lister, and J.G. Dorsey Behavior and use of nonaqueous media without supporting electrolyte in capillary electrophoresis and capillary electrochromatography Anal. Chem. 69 1997 3251 3259
    • (1997) Anal. Chem. , vol.69 , pp. 3251-3259
    • Wright, P.B.1    Lister, A.S.2    Dorsey, J.G.3
  • 53
    • 0001191539 scopus 로고    scopus 로고
    • Characteristics of electroosmotic flow in capillary electrophoresis in water and in organic solvents without added ionic species
    • I.E. Valko, H. Siren, and M. Riekkola Characteristics of electroosmotic flow in capillary electrophoresis in water and in organic solvents without added ionic species J. Microcolumn. Sep. 11 1999 199 208 (Pubitemid 129552520)
    • (1999) Journal of Microcolumn Separations , vol.11 , Issue.3 , pp. 199-208
    • Valko, I.E.1    Siren, H.2    Riekkola, M.-L.3
  • 54
    • 17644393875 scopus 로고    scopus 로고
    • Determination of electroosmotic flow in nonaqueous capillary electrophoresis
    • DOI 10.1016/j.chroma.2005.02.001, Non-Aqueous Electromigration
    • L. Geiser, M. Mirgaldi, and J. Veuthey Determination of electroosmotic flow in nonaqueous capillary electrophoresis J. Chromatogr. A 1068 2005 75 81 (Pubitemid 40568613)
    • (2005) Journal of Chromatography A , vol.1068 , Issue.1 , pp. 75-81
    • Geiser, L.1    Mirgaldi, M.2    Veuthey, J.-L.3