메뉴 건너뛰기




Volumn 186, Issue 2-3, 2011, Pages 1131-1135

A highly selective lead-sensitive electrode with solid contact based on ionic liquid

Author keywords

Ionic liquids; Lead ion selective electrode; Potentiometry; Solid contact

Indexed keywords

ALKALINE EARTH; CONCENTRATION RANGES; DIRECT DETERMINATION; FAST RESPONSE TIME; INDICATOR ELECTRODES; LEAD ION-SELECTIVE ELECTRODE; LEAD IONS; LIMIT OF DETECTION; MEMBRANE SENSORS; NERNSTIAN RESPONSE; PH SENSITIVE; POTENTIOMETRIC TITRATIONS; POTENTIOMETRY; REAL SAMPLES; SOLID CONTACT; SOLID CONTACTS;

EID: 79751527287     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhazmat.2010.11.103     Document Type: Article
Times cited : (31)

References (32)
  • 2
    • 0025767231 scopus 로고
    • Get-the-lead-out guru challenged
    • Palca J. Get-the-lead-out guru challenged. Science 1991, 253:842-843.
    • (1991) Science , vol.253 , pp. 842-843
    • Palca, J.1
  • 3
    • 0036682636 scopus 로고    scopus 로고
    • The new wave of ion-selective electrodes
    • Bakker E., Pretsch E. The new wave of ion-selective electrodes. Anal. Chem. 2002, 72:420A-426A.
    • (2002) Anal. Chem. , vol.72
    • Bakker, E.1    Pretsch, E.2
  • 4
  • 5
    • 35349023806 scopus 로고    scopus 로고
    • Ion-selective electrode potentiometry in environmental analysis
    • De Marco R., Clarke G., Pejcic B. Ion-selective electrode potentiometry in environmental analysis. Electroanalysis 2007, 19:1987-2001.
    • (2007) Electroanalysis , vol.19 , pp. 1987-2001
    • De Marco, R.1    Clarke, G.2    Pejcic, B.3
  • 6
    • 4544273966 scopus 로고    scopus 로고
    • Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range
    • Sutter J., Radu A., Peper S., Bakker E., Pretsch E. Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range. Anal. Chim. Acta 2004, 523:53-59.
    • (2004) Anal. Chim. Acta , vol.523 , pp. 53-59
    • Sutter, J.1    Radu, A.2    Peper, S.3    Bakker, E.4    Pretsch, E.5
  • 8
    • 74549152920 scopus 로고    scopus 로고
    • Ionic liquids in analytical chemistry
    • Sun P., Armstrong D.W. Ionic liquids in analytical chemistry. Anal. Chim. Acta 2010, 661:1-16.
    • (2010) Anal. Chim. Acta , vol.661 , pp. 1-16
    • Sun, P.1    Armstrong, D.W.2
  • 9
    • 37649018729 scopus 로고    scopus 로고
    • Applications of ionic liquids in electrochemical sensors
    • Wei D., Ivaska A. Applications of ionic liquids in electrochemical sensors. Anal. Chim. Acta 2008, 607:126-135.
    • (2008) Anal. Chim. Acta , vol.607 , pp. 126-135
    • Wei, D.1    Ivaska, A.2
  • 11
    • 34250904228 scopus 로고    scopus 로고
    • Ionic liquid 1-octyl-3-methylimidazolium hexafluorophosphate as a solvent for extraction of lead in environmental water samples with detection by graphite furnace atomic absorption spectrometry
    • Haixia S., Zaijun L., Ming L. Ionic liquid 1-octyl-3-methylimidazolium hexafluorophosphate as a solvent for extraction of lead in environmental water samples with detection by graphite furnace atomic absorption spectrometry. Microchim. Acta 2007, 159:95-100.
    • (2007) Microchim. Acta , vol.159 , pp. 95-100
    • Haixia, S.1    Zaijun, L.2    Ming, L.3
  • 12
    • 74449091683 scopus 로고    scopus 로고
    • Hollow fiber based-liquid phase microextraction using ionic liquid solvent for preconcentration of lead and nickel from environmental and biological samples prior to determination by electrothermal atomic absorption spectrometry
    • Abulhassani J., Manzoori J.L., Amjadi M. Hollow fiber based-liquid phase microextraction using ionic liquid solvent for preconcentration of lead and nickel from environmental and biological samples prior to determination by electrothermal atomic absorption spectrometry. J.Hazard. Mater. 2010, 176:481-486.
    • (2010) J.Hazard. Mater. , vol.176 , pp. 481-486
    • Abulhassani, J.1    Manzoori, J.L.2    Amjadi, M.3
  • 13
    • 75749127757 scopus 로고    scopus 로고
    • Tetradecyl (trihexyl)phosphonium chloride ionic liquid single-drop microextraction for electrothermal atomic absorption spectrometric determination of lead in water samples
    • Martinis E.M., Berton P., Altamirano J.C., Hakala U., Wuilloud R.G. Tetradecyl (trihexyl)phosphonium chloride ionic liquid single-drop microextraction for electrothermal atomic absorption spectrometric determination of lead in water samples. Talanta 2010, 80:2034-2040.
    • (2010) Talanta , vol.80 , pp. 2034-2040
    • Martinis, E.M.1    Berton, P.2    Altamirano, J.C.3    Hakala, U.4    Wuilloud, R.G.5
  • 14
    • 0014155324 scopus 로고
    • Electrical phenomena associated with the transport of ions and ion pairs in liquid ion-exchange membranes. I. Zero current properties
    • Sandblom J., Eisenman G., Walker J.L. Electrical phenomena associated with the transport of ions and ion pairs in liquid ion-exchange membranes. I. Zero current properties. J. Phys. Chem. 1967, 71:3862-3870.
    • (1967) J. Phys. Chem. , vol.71 , pp. 3862-3870
    • Sandblom, J.1    Eisenman, G.2    Walker, J.L.3
  • 15
    • 0009983171 scopus 로고
    • Mechanisms of the origins of membrane potentials for pseudo-liquid poly(vinyl chloride) matrix membranes incorporating coordinatively solvated complexes
    • Dumkiewicz R. Mechanisms of the origins of membrane potentials for pseudo-liquid poly(vinyl chloride) matrix membranes incorporating coordinatively solvated complexes. Analyst 1993, 118:1533-1536.
    • (1993) Analyst , vol.118 , pp. 1533-1536
    • Dumkiewicz, R.1
  • 16
    • 0000495604 scopus 로고    scopus 로고
    • Effects of ion transport on the potential response of ionophore-based membrane electrodes: a theoretical approach
    • Morf W.E., Badertscher M., Zwickl T., de Rooij N.F., Pretsch E. Effects of ion transport on the potential response of ionophore-based membrane electrodes: a theoretical approach. J. Phys. Chem. B 1999, 103:11346-11356.
    • (1999) J. Phys. Chem. B , vol.103 , pp. 11346-11356
    • Morf, W.E.1    Badertscher, M.2    Zwickl, T.3    de Rooij, N.F.4    Pretsch, E.5
  • 17
    • 0031765204 scopus 로고    scopus 로고
    • Physicochemical understanding of the selectivity at an ion selective electrode of the liquid membrane type and relation between the selectivity and distribution ratios in the ion-pair extraction
    • Yoshida Y., Matsui M., Maeda K., Kihara S. Physicochemical understanding of the selectivity at an ion selective electrode of the liquid membrane type and relation between the selectivity and distribution ratios in the ion-pair extraction. Anal. Chim. Acta 1998, 374:269-281.
    • (1998) Anal. Chim. Acta , vol.374 , pp. 269-281
    • Yoshida, Y.1    Matsui, M.2    Maeda, K.3    Kihara, S.4
  • 18
    • 0034418660 scopus 로고    scopus 로고
    • Sequence of characteristics of the ion-selective electrode with the pseudoliquid membrane as a function of active substance concentration
    • Dumkiewicz R., Sykut K., Wardak C. Sequence of characteristics of the ion-selective electrode with the pseudoliquid membrane as a function of active substance concentration. Chem. Anal. 2000, 45:383-394.
    • (2000) Chem. Anal. , vol.45 , pp. 383-394
    • Dumkiewicz, R.1    Sykut, K.2    Wardak, C.3
  • 19
    • 0002320693 scopus 로고
    • Microelectrode for potassium ions based on a neutral carrier and comparison of its characteristics with a cation exchanger sensor
    • Oehme M., Simon W. Microelectrode for potassium ions based on a neutral carrier and comparison of its characteristics with a cation exchanger sensor. Anal. Chim. Acta 1976, 86:21-25.
    • (1976) Anal. Chim. Acta , vol.86 , pp. 21-25
    • Oehme, M.1    Simon, W.2
  • 20
    • 0000106133 scopus 로고
    • Neutral carrier potassium-selective electrodes with low resistances
    • Nieman T.A., Horvai G. Neutral carrier potassium-selective electrodes with low resistances. Anal. Chim. Acta 1985, 170:359-363.
    • (1985) Anal. Chim. Acta , vol.170 , pp. 359-363
    • Nieman, T.A.1    Horvai, G.2
  • 21
    • 0001738932 scopus 로고
    • Ionic additives for ion-selective electrodes based on electrically charged carriers
    • Schaller U., Bakker E., Spichiger U.E., Pretsch E. Ionic additives for ion-selective electrodes based on electrically charged carriers. Anal. Chem. 1994, 66:391-398.
    • (1994) Anal. Chem. , vol.66 , pp. 391-398
    • Schaller, U.1    Bakker, E.2    Spichiger, U.E.3    Pretsch, E.4
  • 22
    • 0342369367 scopus 로고    scopus 로고
    • Cationic or anionic sites? Selectivity optimization of ion-selective electrodes based on charged ionophores
    • Amemiya S., Bühlmann P., Pretsch E., Rusterholz B., Umezawa Y. Cationic or anionic sites? Selectivity optimization of ion-selective electrodes based on charged ionophores. Anal. Chem. 2000, 72:1618-1631.
    • (2000) Anal. Chem. , vol.72 , pp. 1618-1631
    • Amemiya, S.1    Bühlmann, P.2    Pretsch, E.3    Rusterholz, B.4    Umezawa, Y.5
  • 23
    • 4544366331 scopus 로고    scopus 로고
    • Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    • Bakker E., Bühlmann P., Pretsch E. Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics. Chem. Rev. 1997, 97:3083-3132.
    • (1997) Chem. Rev. , vol.97 , pp. 3083-3132
    • Bakker, E.1    Bühlmann, P.2    Pretsch, E.3
  • 24
    • 70350132653 scopus 로고    scopus 로고
    • Ionic liquids as new lipophilic additives to the membrane of lead ion-selective electrodes with solid contact
    • Wardak C. Ionic liquids as new lipophilic additives to the membrane of lead ion-selective electrodes with solid contact. Int. J. Environ. Anal. Chem. 2009, 89:735-748.
    • (2009) Int. J. Environ. Anal. Chem. , vol.89 , pp. 735-748
    • Wardak, C.1
  • 25
    • 0033559316 scopus 로고    scopus 로고
    • Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes
    • Sokalski T., Zwickl T., Bakker E., Pretsch E. Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes. Anal. Chem. 1999, 71:1204-1209.
    • (1999) Anal. Chem. , vol.71 , pp. 1204-1209
    • Sokalski, T.1    Zwickl, T.2    Bakker, E.3    Pretsch, E.4
  • 27
    • 37849184975 scopus 로고    scopus 로고
    • The influence of the conditioning procedure on potentiometric characteristics of solid contact calcium-selective electrodes in nanomolar concentration solutions
    • Konopka A., Sokalski T., Lewenstam A., Maj-Z̈urawska M. The influence of the conditioning procedure on potentiometric characteristics of solid contact calcium-selective electrodes in nanomolar concentration solutions. Electroanalysis 2006, 18:2232-2242.
    • (2006) Electroanalysis , vol.18 , pp. 2232-2242
    • Konopka, A.1    Sokalski, T.2    Lewenstam, A.3    Maj-Z̈urawska, M.4
  • 29
    • 0034653614 scopus 로고    scopus 로고
    • Selectivity of potentiometric ion sensors
    • Bakker E., Pretsch E., Bühlman P. Selectivity of potentiometric ion sensors. Anal. Chem. 2000, 72:1127-1133.
    • (2000) Anal. Chem. , vol.72 , pp. 1127-1133
    • Bakker, E.1    Pretsch, E.2    Bühlman, P.3
  • 31
    • 0042030957 scopus 로고    scopus 로고
    • The current usage of selectivity coefficients for the characterization of ion-selective electrodes. A critical survey of the 2000/2001 literature
    • Macca C. The current usage of selectivity coefficients for the characterization of ion-selective electrodes. A critical survey of the 2000/2001 literature. Electroanalysis 2003, 15:997-1010.
    • (2003) Electroanalysis , vol.15 , pp. 997-1010
    • Macca, C.1
  • 32
    • 84930167786 scopus 로고
    • Recommendations for nomenclature of ionselective electrodes
    • Buck R.P., Lindner E. Recommendations for nomenclature of ionselective electrodes. Pure Appl. Chem. 1994, 66:2527-2536.
    • (1994) Pure Appl. Chem. , vol.66 , pp. 2527-2536
    • Buck, R.P.1    Lindner, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.