메뉴 건너뛰기




Volumn 82, Issue 3, 2011, Pages 326-331

Performance of supraglottic airway devices and 12 month skill retention: A randomized controlled study with manikins

Author keywords

Airway management; Bag valve mask; Cardiopulmonary resuscitation (CPR); Manikin; Rescue ventilation; Skill retention; Supraglottic airway devices; Training

Indexed keywords

ARTICLE; DEVICE; GLOTTIS; HUMAN; OUTCOME ASSESSMENT; PERFORMANCE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; RESPIRATION CONTROL; RESUSCITATION; SKILL RETENTION; TIDAL VOLUME; TRAINING;

EID: 79751526400     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2010.11.014     Document Type: Article
Times cited : (23)

References (40)
  • 1
    • 28444447937 scopus 로고    scopus 로고
    • 2005 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Part 4. Advanced life support
    • International Liaison Committee on Resuscitation.
    • International Liaison Committee on Resuscitation 2005 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Part 4. Advanced life support. Resuscitation 2005, 67:213-247.
    • (2005) Resuscitation , vol.67 , pp. 213-247
  • 2
    • 28444490018 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2005. Section 4. Adult advanced life support
    • Nolan J.P., Deakin C.D., Soar J., Bottiger B.W., Smith G. European resuscitation council guidelines for resuscitation 2005. Section 4. Adult advanced life support. Resuscitation 2005, 67(Suppl. 1):S39-S86.
    • (2005) Resuscitation , vol.67 , Issue.SUPPL. 1
    • Nolan, J.P.1    Deakin, C.D.2    Soar, J.3    Bottiger, B.W.4    Smith, G.5
  • 3
    • 28544432407 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2005. Section 2. Adult basic life support and use of automated external defibrillators
    • Handley A.J., Koster R., Monsieurs K., Perkins G.D., Davies S., Bossaert L. European resuscitation council guidelines for resuscitation 2005. Section 2. Adult basic life support and use of automated external defibrillators. Resuscitation 2005, 67(Suppl. 1):S7-S23.
    • (2005) Resuscitation , vol.67 , Issue.SUPPL. 1
    • Handley, A.J.1    Koster, R.2    Monsieurs, K.3    Perkins, G.D.4    Davies, S.5    Bossaert, L.6
  • 4
    • 33646065525 scopus 로고    scopus 로고
    • 2005 American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care
    • 2005 American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2005, 112(Suppl.):IV1-IV203.
    • (2005) Circulation , vol.112 , Issue.SUPPL.
  • 5
    • 28444434052 scopus 로고    scopus 로고
    • 2005 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Part 2. Adult basic life support
    • International Liaison Committee on Resuscitation.
    • International Liaison Committee on Resuscitation 2005 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Part 2. Adult basic life support. Resuscitation 2005, 67:187-201.
    • (2005) Resuscitation , vol.67 , pp. 187-201
  • 6
    • 43449132101 scopus 로고    scopus 로고
    • Airway techniques and ventilation strategies
    • Nolan J.P., Soar J. Airway techniques and ventilation strategies. Curr Opin Crit Care 2008, 14:279-286.
    • (2008) Curr Opin Crit Care , vol.14 , pp. 279-286
    • Nolan, J.P.1    Soar, J.2
  • 7
    • 33646880431 scopus 로고    scopus 로고
    • New airways for resuscitation?
    • Cook T.M., Hommers C. New airways for resuscitation?. Resuscitation 2006, 69:371-387.
    • (2006) Resuscitation , vol.69 , pp. 371-387
    • Cook, T.M.1    Hommers, C.2
  • 8
    • 0037382375 scopus 로고    scopus 로고
    • Comparison of a conventional tracheal airway with the Combitube in an urban emergency medical services system run by physicians
    • Rabitsch W., Schellongowski P., Staudinger T., et al. Comparison of a conventional tracheal airway with the Combitube in an urban emergency medical services system run by physicians. Resuscitation 2003, 57:27-32.
    • (2003) Resuscitation , vol.57 , pp. 27-32
    • Rabitsch, W.1    Schellongowski, P.2    Staudinger, T.3
  • 9
    • 58149349966 scopus 로고    scopus 로고
    • The use of the laryngeal tube disposable (LT-D) by paramedics during out-of-hospital resuscitation-an observational study concerning ERC guidelines 2005
    • Wiese C.H., Semmel T., Muller J.U., Bahr J., Ocker H., Graf B.M. The use of the laryngeal tube disposable (LT-D) by paramedics during out-of-hospital resuscitation-an observational study concerning ERC guidelines 2005. Resuscitation 2009, 80:194-198.
    • (2009) Resuscitation , vol.80 , pp. 194-198
    • Wiese, C.H.1    Semmel, T.2    Muller, J.U.3    Bahr, J.4    Ocker, H.5    Graf, B.M.6
  • 11
    • 0035753757 scopus 로고    scopus 로고
    • The esophageal tracheal combitube as a non-invasive alternative to endotracheal intubation. A review
    • Agro F., Frass M., Benumof J., et al. The esophageal tracheal combitube as a non-invasive alternative to endotracheal intubation. A review. Minerva Anestesiol 2001, 67:863-874.
    • (2001) Minerva Anestesiol , vol.67 , pp. 863-874
    • Agro, F.1    Frass, M.2    Benumof, J.3
  • 12
    • 44649117941 scopus 로고    scopus 로고
    • Evaluation of prehospital insertion of the laryngeal mask airway by primary care paramedics with only classroom mannequin training
    • Murray M.J., Vermeulen M.J., Morrison L.J., Waite T. Evaluation of prehospital insertion of the laryngeal mask airway by primary care paramedics with only classroom mannequin training. CJEM 2002, 4:338-343.
    • (2002) CJEM , vol.4 , pp. 338-343
    • Murray, M.J.1    Vermeulen, M.J.2    Morrison, L.J.3    Waite, T.4
  • 13
    • 0031725203 scopus 로고    scopus 로고
    • The incidence of regurgitation during cardiopulmonary resuscitation: a comparison between the bag valve mask and laryngeal mask airway
    • Stone B.J., Chantler P.J., Baskett P.J. The incidence of regurgitation during cardiopulmonary resuscitation: a comparison between the bag valve mask and laryngeal mask airway. Resuscitation 1998, 38:3-6.
    • (1998) Resuscitation , vol.38 , pp. 3-6
    • Stone, B.J.1    Chantler, P.J.2    Baskett, P.J.3
  • 14
    • 0027481202 scopus 로고
    • A comparison of the laryngeal mask airway and Guedel airway, bag and facemask for manual ventilation following formal training
    • Alexander R., Hodgson P., Lomax D., Bullen C. A comparison of the laryngeal mask airway and Guedel airway, bag and facemask for manual ventilation following formal training. Anaesthesia 1993, 48:231-234.
    • (1993) Anaesthesia , vol.48 , pp. 231-234
    • Alexander, R.1    Hodgson, P.2    Lomax, D.3    Bullen, C.4
  • 15
    • 0033843522 scopus 로고    scopus 로고
    • Skill acquisition in resuscitation
    • Bullock I. Skill acquisition in resuscitation. Resuscitation 2000, 45:139-143.
    • (2000) Resuscitation , vol.45 , pp. 139-143
    • Bullock, I.1
  • 17
    • 23844503650 scopus 로고    scopus 로고
    • Randomized crossover comparison of ProSeal laryngeal mask airway with laryngeal tube Sonda during anaesthesia with controlled ventilation
    • Cook T.M., Cranshaw J. Randomized crossover comparison of ProSeal laryngeal mask airway with laryngeal tube Sonda during anaesthesia with controlled ventilation. Br J Anaesth 2005, 95:261-266.
    • (2005) Br J Anaesth , vol.95 , pp. 261-266
    • Cook, T.M.1    Cranshaw, J.2
  • 18
    • 77950868240 scopus 로고    scopus 로고
    • Predictors of survival from out-of-hospital cardiac arrest: a systematic review and meta-analysis
    • Sasson C., Rogers M.A., Dahl J., Kellermann A.L. Predictors of survival from out-of-hospital cardiac arrest: a systematic review and meta-analysis. Circ Cardiovasc Qual Outcomes 2010, 3:63-81.
    • (2010) Circ Cardiovasc Qual Outcomes , vol.3 , pp. 63-81
    • Sasson, C.1    Rogers, M.A.2    Dahl, J.3    Kellermann, A.L.4
  • 19
    • 0035658838 scopus 로고    scopus 로고
    • Community attitudes towards performing cardiopulmonary resuscitation in Western Australia
    • Jelinek G.A., Gennat H., Celenza T., O'Brien D., Jacobs I., Lynch D. Community attitudes towards performing cardiopulmonary resuscitation in Western Australia. Resuscitation 2001, 51:239-246.
    • (2001) Resuscitation , vol.51 , pp. 239-246
    • Jelinek, G.A.1    Gennat, H.2    Celenza, T.3    O'Brien, D.4    Jacobs, I.5    Lynch, D.6
  • 20
    • 67650046986 scopus 로고    scopus 로고
    • Crossover comparison of the laryngeal mask supreme and the i-gel in simulated difficult airway scenario in anesthetized patients
    • Theiler L.G., Kleine-Brueggeney M., Kaiser D., et al. Crossover comparison of the laryngeal mask supreme and the i-gel in simulated difficult airway scenario in anesthetized patients. Anesthesiology 2009, 111:55-62.
    • (2009) Anesthesiology , vol.111 , pp. 55-62
    • Theiler, L.G.1    Kleine-Brueggeney, M.2    Kaiser, D.3
  • 22
    • 51349155510 scopus 로고    scopus 로고
    • Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients
    • Gatward J.J., Cook T.M., Seller C., et al. Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients. Anaesthesia 2008, 63:1124-1130.
    • (2008) Anaesthesia , vol.63 , pp. 1124-1130
    • Gatward, J.J.1    Cook, T.M.2    Seller, C.3
  • 23
    • 54849423427 scopus 로고    scopus 로고
    • Laryngeal mask LMA Supreme. Application by medical personnel inexperienced in airway management
    • Timmermann A., Cremer S., Heuer J., Braun U., Graf B.M., Russo S.G. Laryngeal mask LMA Supreme. Application by medical personnel inexperienced in airway management. Anaesthesist 2008, 57:970-975.
    • (2008) Anaesthesist , vol.57 , pp. 970-975
    • Timmermann, A.1    Cremer, S.2    Heuer, J.3    Braun, U.4    Graf, B.M.5    Russo, S.G.6
  • 24
    • 77949691561 scopus 로고    scopus 로고
    • LMA Supreme insertion by novices in manikins and patients
    • Howes B.W., Wharton N.M., Gibbison B., Cook T.M. LMA Supreme insertion by novices in manikins and patients. Anaesthesia 2010, 65:343-347.
    • (2010) Anaesthesia , vol.65 , pp. 343-347
    • Howes, B.W.1    Wharton, N.M.2    Gibbison, B.3    Cook, T.M.4
  • 25
    • 78349266744 scopus 로고    scopus 로고
    • Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study
    • [Epub ahead of print]
    • Castle N., Owen R., Hann M., Naidoo R., Reeves D. Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study. Emerg Med J 2010, [Epub ahead of print].
    • (2010) Emerg Med J
    • Castle, N.1    Owen, R.2    Hann, M.3    Naidoo, R.4    Reeves, D.5
  • 26
    • 0031031588 scopus 로고    scopus 로고
    • A comparison of three methods of bag valve mask ventilation
    • Wheatley S., Thomas A.N., Taylor R.J., Brown T. A comparison of three methods of bag valve mask ventilation. Resuscitation 1997, 33:207-210.
    • (1997) Resuscitation , vol.33 , pp. 207-210
    • Wheatley, S.1    Thomas, A.N.2    Taylor, R.J.3    Brown, T.4
  • 27
    • 0034845545 scopus 로고    scopus 로고
    • Ease of ventilation through the cuffed oropharyngeal airway (COPA), the laryngeal mask airway and the face mask in a cardiopulmonary resuscitation training manikin
    • Garcia-Guasch R., Ferra M., Benito P., Oltra J., Roca J. Ease of ventilation through the cuffed oropharyngeal airway (COPA), the laryngeal mask airway and the face mask in a cardiopulmonary resuscitation training manikin. Resuscitation 2001, 50:173-177.
    • (2001) Resuscitation , vol.50 , pp. 173-177
    • Garcia-Guasch, R.1    Ferra, M.2    Benito, P.3    Oltra, J.4    Roca, J.5
  • 28
    • 33344456856 scopus 로고    scopus 로고
    • Retention of ventilation skills of emergency nurses after training with the SMART BAG compared to a standard bag-valve-mask
    • De Regge M., Vogels C., Monsieurs K.G., Calle P.A. Retention of ventilation skills of emergency nurses after training with the SMART BAG compared to a standard bag-valve-mask. Resuscitation 2006, 68:379-384.
    • (2006) Resuscitation , vol.68 , pp. 379-384
    • De Regge, M.1    Vogels, C.2    Monsieurs, K.G.3    Calle, P.A.4
  • 29
    • 33644843413 scopus 로고    scopus 로고
    • Comparison of an oxygen-powered flow-limited resuscitator to manual ventilation with an adult 1,000-mL self-inflating bag
    • Barnes T.A., Catino M.E., Burns E.C., et al. Comparison of an oxygen-powered flow-limited resuscitator to manual ventilation with an adult 1,000-mL self-inflating bag. Respir Care 2005, 50:1445-1450.
    • (2005) Respir Care , vol.50 , pp. 1445-1450
    • Barnes, T.A.1    Catino, M.E.2    Burns, E.C.3
  • 30
    • 0036024420 scopus 로고    scopus 로고
    • Effects of decreasing inspiratory flow rate during simulated basic life support ventilation of a cardiac arrest patient on lung and stomach tidal volumes
    • Stallinger A., Wenzel V., Wagner-Berger H., et al. Effects of decreasing inspiratory flow rate during simulated basic life support ventilation of a cardiac arrest patient on lung and stomach tidal volumes. Resuscitation 2002, 54:167-173.
    • (2002) Resuscitation , vol.54 , pp. 167-173
    • Stallinger, A.1    Wenzel, V.2    Wagner-Berger, H.3
  • 31
    • 26444598306 scopus 로고    scopus 로고
    • The ProSeal laryngeal mask airway: a review of the literature
    • Cook T.M., Lee G., Nolan J.P. The ProSeal laryngeal mask airway: a review of the literature. Can J Anaesth 2005, 52:739-760.
    • (2005) Can J Anaesth , vol.52 , pp. 739-760
    • Cook, T.M.1    Lee, G.2    Nolan, J.P.3
  • 32
    • 33847342814 scopus 로고    scopus 로고
    • Comparison of ventilation and chest compression performance by bystanders using the Impact Model 730 ventilator and a conventional bag valve with mask in a model of adult cardiopulmonary arrest
    • Hurst V.T., West S., Austin P., Branson R., Beck G. Comparison of ventilation and chest compression performance by bystanders using the Impact Model 730 ventilator and a conventional bag valve with mask in a model of adult cardiopulmonary arrest. Resuscitation 2007, 73:123-130.
    • (2007) Resuscitation , vol.73 , pp. 123-130
    • Hurst, V.T.1    West, S.2    Austin, P.3    Branson, R.4    Beck, G.5
  • 33
    • 0031747526 scopus 로고    scopus 로고
    • Gas leak and gastric insufflation during controlled ventilation: face mask versus laryngeal mask airway
    • Ho-Tai L.M., Devitt J.H., Noel A.G., O'Donnell M.P. Gas leak and gastric insufflation during controlled ventilation: face mask versus laryngeal mask airway. Can J Anaesth 1998, 45:206-211.
    • (1998) Can J Anaesth , vol.45 , pp. 206-211
    • Ho-Tai, L.M.1    Devitt, J.H.2    Noel, A.G.3    O'Donnell, M.P.4
  • 34
    • 21544445586 scopus 로고    scopus 로고
    • The use of laryngeal tube by nurses in out-of-hospital emergencies: preliminary experience
    • Kette F., Reffo I., Giordani G., et al. The use of laryngeal tube by nurses in out-of-hospital emergencies: preliminary experience. Resuscitation 2005, 66:21-25.
    • (2005) Resuscitation , vol.66 , pp. 21-25
    • Kette, F.1    Reffo, I.2    Giordani, G.3
  • 35
    • 0035140136 scopus 로고    scopus 로고
    • The laryngeal mask airway: a comprehensive review for the emergency physician
    • Pollack C.V. The laryngeal mask airway: a comprehensive review for the emergency physician. J Emerg Med 2001, 20:53-66.
    • (2001) J Emerg Med , vol.20 , pp. 53-66
    • Pollack, C.V.1
  • 36
    • 76149121811 scopus 로고    scopus 로고
    • Initial ventilation through laryngeal tube instead of face mask in out-of-hospital cardiopulmonary arrest is effective and safe
    • Heuer J.F., Barwing J., Eich C., Quintel M., Crozier T.A., Roessler M. Initial ventilation through laryngeal tube instead of face mask in out-of-hospital cardiopulmonary arrest is effective and safe. Eur J Emerg Med 2010, 17:10-15.
    • (2010) Eur J Emerg Med , vol.17 , pp. 10-15
    • Heuer, J.F.1    Barwing, J.2    Eich, C.3    Quintel, M.4    Crozier, T.A.5    Roessler, M.6
  • 37
    • 0035662387 scopus 로고    scopus 로고
    • Assessment of the use of the laryngeal tube for cardiopulmonary resuscitation in a manikin
    • Genzwuerker H.V., Finteis T., Slabschi D., Groeschel J., Ellinger K. Assessment of the use of the laryngeal tube for cardiopulmonary resuscitation in a manikin. Resuscitation 2001, 51:291-296.
    • (2001) Resuscitation , vol.51 , pp. 291-296
    • Genzwuerker, H.V.1    Finteis, T.2    Slabschi, D.3    Groeschel, J.4    Ellinger, K.5
  • 38
    • 0035016287 scopus 로고    scopus 로고
    • The respiratory system during resuscitation: a review of the history, risk of infection during assisted ventilation, respiratory mechanics, and ventilation strategies for patients with an unprotected airway
    • Wenzel V., Idris A.H., Dorges V., et al. The respiratory system during resuscitation: a review of the history, risk of infection during assisted ventilation, respiratory mechanics, and ventilation strategies for patients with an unprotected airway. Resuscitation 2001, 49:123-134.
    • (2001) Resuscitation , vol.49 , pp. 123-134
    • Wenzel, V.1    Idris, A.H.2    Dorges, V.3
  • 39
    • 34250654115 scopus 로고    scopus 로고
    • Evaluation of four airway training manikins as patient simulators for the insertion of single use laryngeal mask airways
    • Cook T.M., Green C., McGrath J., Srivastava R. Evaluation of four airway training manikins as patient simulators for the insertion of single use laryngeal mask airways. Anaesthesia 2007, 62:713-718.
    • (2007) Anaesthesia , vol.62 , pp. 713-718
    • Cook, T.M.1    Green, C.2    McGrath, J.3    Srivastava, R.4
  • 40
    • 33947654834 scopus 로고    scopus 로고
    • Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices
    • Jackson K.M., Cook T.M. Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia 2007, 62:388-393.
    • (2007) Anaesthesia , vol.62 , pp. 388-393
    • Jackson, K.M.1    Cook, T.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.