메뉴 건너뛰기




Volumn 19, Issue 4, 2011, Pages 1088-1095

Effect of micro-channel geometry on fluid flow and mixing

Author keywords

CFD; Microfluidic channel; Mixing

Indexed keywords

2-D MODEL; CFD; CFD ANALYSIS; CHANNEL GEOMETRY; CHANNEL WALL; DIFFERENT GEOMETRY; DIFFUSION GRADIENTS; DIFFUSIVE MIXING; FLOW CHARACTERISTIC; FLUENT SOFTWARE; FLUID FLOW; INLET VELOCITY; LATERAL PRESSURES; MASS FRACTION; MICRO-SCALES; MICROFLUIDIC CHANNEL; MIXING BEHAVIOUR; MIXING EFFICIENCY; RECTANGULAR BLOCK; VELOCITY VECTORS;

EID: 79751525522     PISSN: 1569190X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.simpat.2010.12.008     Document Type: Article
Times cited : (50)

References (14)
  • 1
    • 0347134477 scopus 로고    scopus 로고
    • Whiteside, microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
    • K. Samuel, and M. George Whiteside, microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies Electrophoresis 24 2003 3563 3576
    • (2003) Electrophoresis , vol.24 , pp. 3563-3576
    • Samuel, K.1    George, M.2
  • 2
    • 0000032056 scopus 로고    scopus 로고
    • Microfluidics: Basic issues, applications, and challenges
    • H.A. Stone, and K. Kim Microfluidics: basic issues, applications, and challenges AIChE Journal 47 6 2001 8
    • (2001) AIChE Journal , vol.47 , Issue.6 , pp. 8
    • Stone, H.A.1    Kim, K.2
  • 3
    • 0036643808 scopus 로고    scopus 로고
    • PDMS-based microfluidic devices for biomedical applications
    • DOI 10.1016/S0167-9317(02)00494-X, PII S016793170200494X
    • Teruo Fujii PDMS-based microfluidic devices for biomedical applications Microelectronic Engineering 61-62 2002 907 914 (Pubitemid 34613463)
    • (2002) Microelectronic Engineering , vol.61-62 , pp. 907-914
    • Fujii, T.1
  • 5
    • 16444370563 scopus 로고    scopus 로고
    • DNA separation with low-viscosity sieving matrix on microfabricated polycarbonate microfluidic chips
    • M.Y. Ye DNA separation with low-viscosity sieving matrix on microfabricated polycarbonate microfluidic chips Analytical and Bioanalytical Chemistry 381 2005 820 827
    • (2005) Analytical and Bioanalytical Chemistry , vol.381 , pp. 820-827
    • Ye, M.Y.1
  • 7
    • 15944366532 scopus 로고    scopus 로고
    • Microreactor technology: A revolution for the chemical and pharmaceutical industries?
    • D.M.L. Roberge, and D.N. Bieler Microreactor technology: a revolution for the chemical and pharmaceutical industries? Chemical Engineering & Technology 28 3 2005 318 323
    • (2005) Chemical Engineering & Technology , vol.28 , Issue.3 , pp. 318-323
    • Roberge, D.M.L.1    Bieler, D.N.2
  • 9
    • 59249106870 scopus 로고    scopus 로고
    • Fluent Inc., Lebanon, New Hampshire, USA
    • Gambit 2.4.6, User Guide, Fluent Inc., Lebanon, New Hampshire, USA, 2007.
    • (2007) Gambit 2.4.6, User Guide
  • 10
    • 2942674980 scopus 로고    scopus 로고
    • An example of a chaotic micromixer: The cross-channel micromixer
    • DOI 10.1016/j.crhy.2004.03.003, PII S1631070504000556, Microfluidics
    • A. Dodge, M.C. Jullien, Y.K. Lee, X. Niu, F. Okkels, and P. Tabeling An example of a chaotic micromixer: the cross-channel micromixer CR Physique 5 2004 557 563 (Pubitemid 38773513)
    • (2004) Comptes Rendus Physique , vol.5 , Issue.5 , pp. 557-563
    • Dodge, A.1    Jullien, M.-C.2    Lee, Y.-K.3    Niu, X.4    Okkels, F.5    Tabeling, P.6
  • 12
    • 0041733562 scopus 로고    scopus 로고
    • Investigation of mixing in a cross-shaped micromixer with static mixing elements for reaction kinetics studies
    • S.H. Wong, P. Byrant, M. Ward, and C. Wharton Investigation of mixing in a cross-shaped micromixer with static mixing elements for reaction kinetics studies Sensors and Actuators 95 2003 414 424
    • (2003) Sensors and Actuators , vol.95 , pp. 414-424
    • Wong, S.H.1    Byrant, P.2    Ward, M.3    Wharton, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.