메뉴 건너뛰기




Volumn 21, Issue 3, 2011, Pages 530-537

Dose levels at coronary CT angiography-a comparison of Dual Energy-, Dual Source- and 16-slice CT

Author keywords

Cardiac CT; Computed tomography; Coronary CT angiography; Dual energy CT; Dual source CT

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; CORONARY COMPUTED TOMOGRAPHIC ANGIOGRAPHY; DUAL ENERGY COMPUTER ASSISTED TOMOGRAPHY; DUAL SOURCE COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RADIATION DOSE; RETROSPECTIVE STUDY; SIGNAL NOISE RATIO; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 79751504495     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-010-1954-9     Document Type: Article
Times cited : (40)

References (41)
  • 2
    • 33750960085 scopus 로고    scopus 로고
    • Computed tomography coronary angiography
    • DOI 10.1016/j.jacc.2006.08.012, PII S0735109706020894, Cardiac Imaging
    • S Achenbach 2006 Computed tomography coronary angiography J Am Coll Cardiol 48 1919 1928 10.1016/j.jacc.2006.08.012 17112978 (Pubitemid 44738433)
    • (2006) Journal of the American College of Cardiology , vol.48 , Issue.10 , pp. 1919-1928
    • Achenbach, S.1
  • 3
    • 33750206253 scopus 로고    scopus 로고
    • Assessment of coronary artery disease by cardiac computed tomography: A scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology
    • DOI 10.1161/CIRCULATIONAHA.106.178458, PII 0000301720061017000018
    • MJ Budoff S Achenbach RS Blumenthal, et al. 2006 Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology Circulation 114 1761 1791 10.1161/CIRCULATIONAHA.106.178458 17015792 (Pubitemid 44607126)
    • (2006) Circulation , vol.114 , Issue.16 , pp. 1761-1791
    • Budoff, M.J.1    Achenbach, S.2    Blumenthal, R.S.3    Carr, J.J.4    Goldin, J.G.5    Greenland, P.6    Guerci, A.D.7    Lima, J.A.C.8    Rader, D.J.9    Rubin, G.D.10    Shaw, L.J.11    Wiegers, S.E.12
  • 4
    • 33749061448 scopus 로고    scopus 로고
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: A report of the American College of Cardiology Foundation Quality Strategic Directions
    • Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology, 10.1016/j.jacc.2006. 07.003 17010819
    • RC Hendel MR Patel CM Kramer, et al. 2006 ACCF/ACR/SCCT/SCMR/ASNC/NASCI/ SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology J Am Coll Cardiol 48 1475 1497 10.1016/j.jacc.2006.07. 003 17010819
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1475-1497
    • Hendel, R.C.1    Patel, M.R.2    Kramer, C.M.3
  • 5
    • 35348977748 scopus 로고    scopus 로고
    • Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study
    • DOI 10.1148/radiol.2452061919
    • CM Heyer PS Mohr SP Lemburg SA Peters V Nicolas 2007 Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study Radiology 245 577 583 10.1148/radiol.2452061919 17940308 (Pubitemid 47612541)
    • (2007) Radiology , vol.245 , Issue.2 , pp. 577-583
    • Heyer, C.M.1    Mohr, P.S.2    Lemburg, S.P.3    Peters, S.A.4    Nicolas, V.5
  • 6
    • 53849098569 scopus 로고    scopus 로고
    • Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: Initial results
    • 1:STN:280:DC%2BD1M7mt1SmtA%3D%3D 19238637
    • C Fink TR Johnson HJ Michaely, et al. 2008 Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism: initial results Rofo 180 879 883 1:STN:280:DC%2BD1M7mt1SmtA%3D%3D 19238637
    • (2008) Rofo , vol.180 , pp. 879-883
    • Fink, C.1    Johnson, T.R.2    Michaely, H.J.3
  • 8
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience
    • Marin D, Nelson RC, Schindera ST et al (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience. Radiology 254:145-153
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 9
    • 33847196400 scopus 로고    scopus 로고
    • Circle of Willis at CT angiography: Dose reduction and image quality-reducing tube voltage and increasing tube current settings
    • 10.1148/radiol.2423051191 17229873
    • A Waaijer M Prokop BK Velthuis CJ Bakker GA de Kort MS van Leeuwen 2007 Circle of Willis at CT angiography: dose reduction and image quality-reducing tube voltage and increasing tube current settings Radiology 242 832 839 10.1148/radiol.2423051191 17229873
    • (2007) Radiology , vol.242 , pp. 832-839
    • Waaijer, A.1    Prokop, M.2    Velthuis, B.K.3    Bakker, C.J.4    De Kort, G.A.5    Van Leeuwen, M.S.6
  • 10
    • 33845741615 scopus 로고    scopus 로고
    • 16-MDCT angiography in living kidney donors at various tube potentials: Impact on image quality and radiation dose
    • DOI 10.2214/AJR.05.0583
    • DV Sahani SP Kalva PF Hahn S Saini 2007 16-MDCT angiography in living kidney donors at various tube potentials: impact on image quality and radiation dose AJR Am J Roentgenol 188 115 120 10.2214/AJR.05.0583 17179353 (Pubitemid 46012497)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.1 , pp. 115-120
    • Sahani, D.V.1    Kalva, S.P.2    Hahn, P.F.3    Saini, S.4
  • 11
    • 38949105939 scopus 로고    scopus 로고
    • Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: Phantom study
    • 10.2214/AJR.07.2891 18212190
    • ST Schindera RC Nelson TL Toth, et al. 2008 Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study AJR Am J Roentgenol 190 W100 W105 10.2214/AJR.07.2891 18212190
    • (2008) AJR Am J Roentgenol , vol.190
    • Schindera, S.T.1    Nelson, R.C.2    Toth, T.L.3
  • 12
    • 41149094005 scopus 로고    scopus 로고
    • Myocardial ischemia diagnosed by dual-energy computed tomography: Correlation with single-photon emission computed tomography
    • DOI 10.1161/CIRCULATIONAHA.107.745711, PII 0000301720080304000018
    • B Ruzsics H Lee ER Powers TG Flohr P Costello UJ Schoepf 2008 Images in cardiovascular medicine. Myocardial ischemia diagnosed by dual-energy computed tomography: correlation with single-photon emission computed tomography Circulation 117 1244 1245 10.1161/CIRCULATIONAHA.107.745711 18316501 (Pubitemid 351544058)
    • (2008) Circulation , vol.117 , Issue.9 , pp. 1244-1245
    • Ruzsics, B.1    Lee, H.2    Powers, E.R.3    Flohr, T.G.4    Costello, P.5    Schoepf, U.J.6
  • 13
    • 54049156093 scopus 로고    scopus 로고
    • Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience
    • 10.1007/s00330-008-1022-x 18523782
    • B Ruzsics H Lee PL Zwerner M Gebregziabher P Costello UJ Schoepf 2008 Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience Eur Radiol 18 2414 2424 10.1007/s00330-008-1022-x 18523782
    • (2008) Eur Radiol , vol.18 , pp. 2414-2424
    • Ruzsics, B.1    Lee, H.2    Zwerner, P.L.3    Gebregziabher, M.4    Costello, P.5    Schoepf, U.J.6
  • 14
    • 3042601810 scopus 로고    scopus 로고
    • Effect of multislice scanners on patient dose from routine CT examinations in East Anglia
    • DOI 10.1259/bjr/21927258
    • SJ Yates LC Pike KE Goldstone 2004 Effect of multislice scanners on patient dose from routine CT examinations in East Anglia Br J Radiol 77 472 478 1:STN:280:DC%2BD2c3lt12msg%3D%3D 10.1259/bjr/21927258 15151967 (Pubitemid 38807561)
    • (2004) British Journal of Radiology , vol.77 , Issue.918 , pp. 472-478
    • Yates, S.J.1    Pike, L.C.2    Goldstone, K.E.3
  • 15
    • 59649127716 scopus 로고    scopus 로고
    • Estimated radiation dose associated with cardiac CT angiography
    • 1:CAS:528:DC%2BD1MXhtlyksbk%3D 10.1001/jama.2009.54 19190314
    • J Hausleiter T Meyer F Hermann, et al. 2009 Estimated radiation dose associated with cardiac CT angiography JAMA 301 500 507 1:CAS:528: DC%2BD1MXhtlyksbk%3D 10.1001/jama.2009.54 19190314
    • (2009) JAMA , vol.301 , pp. 500-507
    • Hausleiter, J.1    Meyer, T.2    Hermann, F.3
  • 17
    • 0035176903 scopus 로고    scopus 로고
    • Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    • DOI 10.1097/00004728-200111000-00014
    • T Flohr B Ohnesorge 2001 Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart J Comput Assist Tomogr 25 907 923 1:STN:280:DC%2BD3MnmsFygtA%3D%3D 10.1097/00004728-200111000-00014 11711804 (Pubitemid 33091669)
    • (2001) Journal of Computer Assisted Tomography , vol.25 , Issue.6 , pp. 907-923
    • Flohr, T.1    Ohnesorge, B.2
  • 19
    • 51549088875 scopus 로고    scopus 로고
    • Converting dose-length product to effective dose at CT
    • 10.1148/radiol.2483071964 18710988
    • W Huda KM Ogden MR Khorasani 2008 Converting dose-length product to effective dose at CT Radiology 248 995 1003 10.1148/radiol.2483071964 18710988
    • (2008) Radiology , vol.248 , pp. 995-1003
    • Huda, W.1    Ogden, K.M.2    Khorasani, M.R.3
  • 20
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
    • 1:STN:280:DyaE2M7htFersg%3D%3D 1116248
    • WG Austen JE Edwards RL Frye, et al. 1975 A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association Circulation 51 4 Suppl 5 40 1:STN:280:DyaE2M7htFersg%3D%3D 1116248
    • (1975) Circulation , vol.51 , Issue.4 SUPPL. , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 21
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • JR Landis GG Koch 1977 The measurement of observer agreement for categorical data Biometrics 33 159 174 1:STN:280:DyaE2s7jsFWqtA%3D%3D 10.2307/2529310 843571 (Pubitemid 8054849)
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 23
    • 38349134611 scopus 로고    scopus 로고
    • Feasibility of low-dose coronary CT angiography: First experience with prospective ECG-gating
    • 10.1093/eurheartj/ehm613 18089704
    • L Husmann I Valenta O Gaemperli, et al. 2008 Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating Eur Heart J 29 191 197 10.1093/eurheartj/ehm613 18089704
    • (2008) Eur Heart J , vol.29 , pp. 191-197
    • Husmann, L.1    Valenta, I.2    Gaemperli, O.3
  • 24
    • 49049116757 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: Comparison of image quality and patient radiation dose
    • 10.1148/radiol.2482072192 18552312
    • WP Shuman KR Branch JM May, et al. 2008 Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose Radiology 248 431 437 10.1148/radiol. 2482072192 18552312
    • (2008) Radiology , vol.248 , pp. 431-437
    • Shuman, W.P.1    Branch, K.R.2    May, J.M.3
  • 25
    • 49049120370 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: Assessment of image quality, stenosis, and radiation dose
    • 10.1148/radiol.2482071804 18574140
    • N Hirai J Horiguchi C Fujioka, et al. 2008 Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose Radiology 248 424 430 10.1148/radiol.2482071804 18574140
    • (2008) Radiology , vol.248 , pp. 424-430
    • Hirai, N.1    Horiguchi, J.2    Fujioka, C.3
  • 26
    • 56349098754 scopus 로고    scopus 로고
    • Radiation dose of cardiac dual-source CT: The effect of tailoring the protocol to patient-specific parameters
    • 10.1016/j.ejrad.2008.08.015 18976876
    • H Alkadhi P Stolzmann H Scheffel, et al. 2008 Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters Eur J Radiol 68 385 391 10.1016/j.ejrad.2008.08.015 18976876
    • (2008) Eur J Radiol , vol.68 , pp. 385-391
    • Alkadhi, H.1    Stolzmann, P.2    Scheffel, H.3
  • 27
    • 49049083272 scopus 로고    scopus 로고
    • Low kilovoltage cardiac dual-source CT: Attenuation, noise, and radiation dose
    • 10.1007/s00330-008-0966-1 18392829
    • S Leschka P Stolzmann FT Schmid, et al. 2008 Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose Eur Radiol 18 1809 1817 10.1007/s00330-008-0966-1 18392829
    • (2008) Eur Radiol , vol.18 , pp. 1809-1817
    • Leschka, S.1    Stolzmann, P.2    Schmid, F.T.3
  • 28
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates
    • DOI 10.1161/CIRCULATIONAHA.105.602490, PII 0000301720060314000008
    • J Hausleiter T Meyer M Hadamitzky, et al. 2006 Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates Circulation 113 1305 1310 10.1161/CIRCULATIONAHA.105.602490 16520411 (Pubitemid 43739452)
    • (2006) Circulation , vol.113 , Issue.10 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3    Huber, E.4    Zankl, M.5    Martinoff, S.6    Kastrati, A.7    Schomig, A.8
  • 29
    • 63849123042 scopus 로고    scopus 로고
    • Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography
    • 10.2214/AJR.08.1025 19304712
    • T Pflederer L Rudofsky D Ropers, et al. 2009 Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography AJR Am J Roentgenol 192 1045 1050 10.2214/AJR.08.1025 19304712
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 1045-1050
    • Pflederer, T.1    Rudofsky, L.2    Ropers, D.3
  • 30
    • 76949084425 scopus 로고    scopus 로고
    • Low-dose CT coronary angiography for the prediction of myocardial ischaemia
    • Stolzmann P, Donati OF, Scheffel H et al (2010) Low-dose CT coronary angiography for the prediction of myocardial ischaemia. Eur Radiol 20:56-64
    • (2010) Eur Radiol , vol.20 , pp. 56-64
    • Stolzmann, P.1    Donati, O.F.2    Scheffel, H.3
  • 31
    • 0033735138 scopus 로고    scopus 로고
    • Technique factors and image quality as functions of patient weight at abdominal CT
    • 1:STN:280:DC%2BD3crhtFequw%3D%3D 11058640
    • W Huda EM Scalzetti G Levin 2000 Technique factors and image quality as functions of patient weight at abdominal CT Radiology 217 430 435 1:STN:280:DC%2BD3crhtFequw%3D%3D 11058640
    • (2000) Radiology , vol.217 , pp. 430-435
    • Huda, W.1    Scalzetti, E.M.2    Levin, G.3
  • 33
    • 0041842489 scopus 로고    scopus 로고
    • Dose reduction in pediatric CT: A rational approach
    • DOI 10.1148/radiol.2282020471
    • JM Boone EM Geraghty JA Seibert SL Wootton-Gorges 2003 Dose reduction in pediatric CT: a rational approach Radiology 228 352 360 10.1148/radiol. 2282020471 12893897 (Pubitemid 36910072)
    • (2003) Radiology , vol.228 , Issue.2 , pp. 352-360
    • Boone, J.M.1    Geraghty, E.M.2    Seibert, J.A.3    Wootton-Gorges, S.L.4
  • 34
    • 68049147545 scopus 로고    scopus 로고
    • Radiation dose exposure of computed tomography coronary angiography: Comparison of dual-source, 16-slice and 64-slice CT
    • 1:STN:280:DC%2BD1Mrhs1SksQ%3D%3D 10.1136/hrt.2008.161018 19482842
    • J Rixe G Conradi A Rolf, et al. 2009 Radiation dose exposure of computed tomography coronary angiography: comparison of dual-source, 16-slice and 64-slice CT Heart 95 1337 1342 1:STN:280:DC%2BD1Mrhs1SksQ%3D%3D 10.1136/hrt.2008.161018 19482842
    • (2009) Heart , vol.95 , pp. 1337-1342
    • Rixe, J.1    Conradi, G.2    Rolf, A.3
  • 35
    • 62649158904 scopus 로고    scopus 로고
    • Prospectively gated axial CT coronary angiography: Preliminary experiences with a novel low-dose technique
    • 10.1007/s00330-008-1222-4 19011864
    • O Klass M Jeltsch S Feuerlein, et al. 2009 Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique Eur Radiol 19 829 836 10.1007/s00330-008-1222-4 19011864
    • (2009) Eur Radiol , vol.19 , pp. 829-836
    • Klass, O.1    Jeltsch, M.2    Feuerlein, S.3
  • 36
    • 70350210490 scopus 로고    scopus 로고
    • Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: Technique and initial experience
    • 10.1007/s00330-009-1558-4 19760421
    • M Lell M Marwan T Schepis, et al. 2009 Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience Eur Radiol 19 2576 2583 10.1007/s00330-009- 1558-4 19760421
    • (2009) Eur Radiol , vol.19 , pp. 2576-2583
    • Lell, M.1    Marwan, M.2    Schepis, T.3
  • 37
    • 70349868350 scopus 로고    scopus 로고
    • Cardiac spiral dual-source CT with high pitch: A feasibility study
    • 10.1007/s00330-009-1503-6 19565245
    • D Ertel MM Lell F Harig T Flohr B Schmidt WA Kalender 2009 Cardiac spiral dual-source CT with high pitch: a feasibility study Eur Radiol 19 2357 2362 10.1007/s00330-009-1503-6 19565245
    • (2009) Eur Radiol , vol.19 , pp. 2357-2362
    • Ertel, D.1    Lell, M.M.2    Harig, F.3    Flohr, T.4    Schmidt, B.5    Kalender, W.A.6
  • 38
    • 1642389455 scopus 로고    scopus 로고
    • Low-kilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose
    • DOI 10.1148/radiol.2311030191
    • AB Sigal-Cinqualbre R Hennequin HT Abada X Chen JF Paul 2004 Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose Radiology 231 169 174 10.1148/radiol.2311030191 15068946 (Pubitemid 38375425)
    • (2004) Radiology , vol.231 , Issue.1 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3    Chen, X.4    Paul, J.-F.5
  • 39
    • 33746700916 scopus 로고    scopus 로고
    • Contrast bolus optimization for cardiac 16-slice computed tomography: Comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter
    • DOI 10.1097/01.rli.0000208239.34723.5d, PII 0000442420060500000006
    • C Rist K Nikolaou MA Kirchin, et al. 2006 Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter Invest Radiol 41 460 467 10.1097/01.rli.0000208239.34723.5d 16625109 (Pubitemid 44284194)
    • (2006) Investigative Radiology , vol.41 , Issue.5 , pp. 460-467
    • Rist, C.1    Nikolaou, K.2    Kirchin, M.A.3    Van Gessel, R.4    Ty Bae, K.5    Von Ziegler, F.6    Knez, A.7    Wintersperger, B.J.8    Reiser, M.F.9    Becker, C.R.10
  • 40
    • 31544479569 scopus 로고    scopus 로고
    • Left ventricular function studied with MDCT
    • DOI 10.1007/s00330-005-2888-5
    • KU Juergens R Fischbach 2006 Left ventricular function studied with MDCT Eur Radiol 16 342 357 10.1007/s00330-005-2888-5 16132917 (Pubitemid 43153682)
    • (2006) European Radiology , vol.16 , Issue.2 , pp. 342-357
    • Juergens, K.U.1    Fischbach, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.