메뉴 건너뛰기




Volumn 14, Issue 2, 2011, Pages 151-166

Stereotactic body radiotherapy for spinal metastases: Current status, with a focus on its application in the postoperative patient. A review

Author keywords

Malignant epidural spinal cord compression; Postoperative radiation; Spinal metastasis; Spine radiosurgery; Spine stereotactic body radiotherapy

Indexed keywords

BONE INJURY; BREAST CANCER; COLLIMATOR; COMPUTER ASSISTED TOMOGRAPHY; CYBERKNIFE; EXTERNAL BEAM RADIOTHERAPY; HUMAN; IMAGE ANALYSIS; IMMOBILIZATION; LAMINECTOMY; LINEAR ACCELERATOR; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTOPERATIVE CARE; RADIATION DOSE; RADIATION DOSE FRACTIONATION; RADIATION INJURY; RANDOMIZED CONTROLLED TRIAL (TOPIC); REVIEW; SPINAL CORD DISEASE; SPINAL CORD METASTASIS; SPINAL CORD NECROSIS; STEREOTACTIC BODY RADIATION THERAPY; TREATMENT FAILURE; TREATMENT OUTCOME; TREATMENT PLANNING; TUMOR LOCALIZATION; TUMOR VOLUME;

EID: 79551704057     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2010.9.SPINE091005     Document Type: Review
Times cited : (172)

References (59)
  • 2
    • 0033010153 scopus 로고    scopus 로고
    • Image-guided robotic radiosurgery
    • DOI 10.1097/00006123-199906000-00079
    • Adler JR Jr, Murphy MJ, Chang SD, Hancock SL: Image-guided robotic radiosurgery. Neurosurgery 44:1299-1307, 1999 (Pubitemid 29252751)
    • (1999) Neurosurgery , vol.44 , Issue.6 , pp. 1299-1307
    • Adler Jr., J.R.1    Murphy, M.J.2    Chang, S.D.3    Hancock, S.L.4
  • 5
    • 37849187029 scopus 로고    scopus 로고
    • A review of 3 current radiosurgery systems
    • DOI 10.1016/j.surneu.2006.08.002, PII S0090301906006306
    • Andrews DW, Bednarz G, Evans JJ, Downes B: A review of 3 current radiosurgery systems. Surg Neurol 66:559-564, 2006 (Pubitemid 44827189)
    • (2006) Surgical Neurology , vol.66 , Issue.6 , pp. 559-564
    • Andrews, D.W.1    Bednarz, G.2    Evans, J.J.3    Downes, B.4
  • 6
    • 56049083730 scopus 로고    scopus 로고
    • Spinal radiosurgery: Technology and clinical outcomes
    • Avanzo M, Romanelli P: Spinal radiosurgery: technology and clinical outcomes. Neurosurg Rev 32:1-13, 2009
    • (2009) Neurosurg Rev , vol.32 , pp. 1-13
    • Avanzo, M.1    Romanelli, P.2
  • 11
    • 35048842987 scopus 로고    scopus 로고
    • CyberKnife radiosurgery for breast cancer spine metastases: A matched-pair analysis
    • DOI 10.1002/cncr.22977
    • Gagnon GJ, Henderson FC, Gehan EA, Sanford D, Collins BT, Moulds JC, et al: Cyberknife radiosurgery for breast cancer spine metastases: a matched-pair analysis. Cancer 110:1796-1802, 2007 (Pubitemid 47557305)
    • (2007) Cancer , vol.110 , Issue.8 , pp. 1796-1802
    • Gagnon, G.J.1    Henderson, F.C.2    Gehan, E.A.3    Sanford, D.4    Collins, B.T.5    Moulds, J.C.6    Dritschilo, A.7
  • 12
    • 61449121058 scopus 로고    scopus 로고
    • Treatment of spinal tumors using cyberknife fractionated stereotactic radiosurgery: Pain and quality-of-life assessment after treatment in 200 patients
    • Gagnon GJ, Nasr NM, Liao JJ, Molzahn I, Marsh D, McRae D, et al: Treatment of spinal tumors using cyberknife fractionated stereotactic radiosurgery: pain and quality-of-life assessment after treatment in 200 patients. Neurosurgery 64:297-307, 2009
    • (2009) Neurosurgery , vol.64 , pp. 297-307
    • Gagnon, G.J.1    Nasr, N.M.2    Liao, J.J.3    Molzahn, I.4    Marsh, D.5    McRae, D.6
  • 15
    • 33846246264 scopus 로고    scopus 로고
    • Radiosurgery for spinal metastases: Clinical experience in 500 cases from a single institution
    • DOI 10.1097/01.brs.0000251863.76595.a2, PII 0000763220070115000009
    • Gerszten PC, Burton SA, Ozhasoglu C, Welch WC: Radiosurgery for spinal metastases: clinical experience in 500 cases from a single institution. Spine 32:193-199, 2007 (Pubitemid 46105806)
    • (2007) Spine , vol.32 , Issue.2 , pp. 193-199
    • Gerszten, P.C.1    Burton, S.A.2    Ozhasoglu, C.3    Welch, W.C.4
  • 21
    • 34447106601 scopus 로고    scopus 로고
    • Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT)
    • DOI 10.1016/j.radonc.2007.05.021, PII S0167814007002423
    • Guckenberger M, Meyer J, Wilbert J, Baier K, Bratengeier K, Vordermark D, et al: Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT). Radiother Oncol 84:56-63, 2007 (Pubitemid 47030693)
    • (2007) Radiotherapy and Oncology , vol.84 , Issue.1 , pp. 56-63
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3    Baier, K.4    Bratengeier, K.5    Vordermark, D.6    Flentje, M.7
  • 22
    • 34347269146 scopus 로고    scopus 로고
    • Precision of image-guided radiotherapy (IGRT) in six degrees of freedom and limitations in clinical practice
    • DOI 10.1007/s00066-007-1695-0
    • Guckenberger M, Meyer J, Wilbert J, Baier K, Sauer O, Flentje M: Precision of image-guided radiotherapy (IGRT) in six degrees of freedom and limitations in clinical practice. Strahlenther Onkol 183:307-313, 2007 (Pubitemid 46996069)
    • (2007) Strahlentherapie und Onkologie , vol.183 , Issue.6 , pp. 307-313
    • Guckenberger, M.1    Meyer, J.2    Wilbert, J.3    Baier, K.4    Sauer, O.5    Flentje, M.6
  • 23
    • 0028833151 scopus 로고
    • Preliminary clinical experience with linear accelerator-based spinal stereotactic radiosurgery
    • Hamilton AJ, Lulu BA, Fosmire H, Stea B, Cassady JR: Preliminary clinical experience with linear accelerator-based spinal stereotactic radiosurgery. Neurosurgery 36:311-319, 1995
    • (1995) Neurosurgery , vol.36 , pp. 311-319
    • Hamilton, A.J.1    Lulu, B.A.2    Fosmire, H.3    Stea, B.4    Cassady, J.R.5
  • 25
    • 40049112446 scopus 로고    scopus 로고
    • Evaluation of residual patient position variation for spinal radiosurgery using the Novalis image guided system
    • DOI 10.1118/1.2839097
    • Jin JY, Ryu S, Rock J, Faber K, Chen Q, Ajlouni M, et al: Evaluation of residual patient position variation for spinal radiosurgery using the Novalis image guided system. Med Phys 35:1087-1093, 2008 (Pubitemid 351322654)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 1087-1093
    • Jin, J.-Y.1    Ryu, S.2    Rock, J.3    Faber, K.4    Chen, Q.5    Ajlouni, M.6    Movsas, B.7
  • 26
    • 0031695614 scopus 로고    scopus 로고
    • Surgical results for spinal metastases
    • DOI 10.1007/s007010050199
    • Klekamp J, Samii H: Surgical results for spinal metastases. Acta Neurochir (Wien) 140:957-967, 1998 (Pubitemid 28474666)
    • (1998) Acta Neurochirurgica , vol.140 , Issue.9 , pp. 957-967
    • Klekamp, J.1    Samii, H.2
  • 27
    • 47149097983 scopus 로고    scopus 로고
    • Comparison of kilovoltage cone-beam computed tomography with megavoltage projection pairs for paraspinal radiosurgery patient alignment and position verification
    • Kriminski SA, Lovelock DM, Seshan VE, Ali I, Munro P, Amols HI, et al: Comparison of kilovoltage cone-beam computed tomography with megavoltage projection pairs for paraspinal radiosurgery patient alignment and position verification. Int J Radiat Oncol Biol Phys 71:1572-1580, 2008
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 1572-1580
    • Kriminski, S.A.1    Lovelock, D.M.2    Seshan, V.E.3    Ali, I.4    Munro, P.5    Amols, H.I.6
  • 29
    • 79551695806 scopus 로고    scopus 로고
    • Apparatus-dependent differences in spine stereotactic body radiotherapy (SBRT) dosimetry
    • Ma L, Cozzi L, Larson DA, Shiu A, Letourneau D, Yin F, et al: Apparatus-dependent differences in spine stereotactic body radiotherapy (SBRT) dosimetry. Int J Radiat Oncol Biol Phys 75 (Suppl):S676-S677, 2009
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , Issue.SUPPL.
    • Ma, L.1    Cozzi, L.2    Larson, D.A.3    Shiu, A.4    Letourneau, D.5    Yin, F.6
  • 30
    • 76049083835 scopus 로고    scopus 로고
    • Equivalence in dose fall-off for isocentric and nonisocentric intracranial treatment modalities and its impact on dose fractionation schemes
    • Ma L, Sahgal A, Descovich M, Cho YB, Chuang C, Huang K, et al: Equivalence in dose fall-off for isocentric and nonisocentric intracranial treatment modalities and its impact on dose fractionation schemes. Int J Radiat Oncol Biol Phys 76:943-948, 2010
    • (2010) Int J Radiat Oncol Biol Phys , vol.76 , pp. 943-948
    • Ma, L.1    Sahgal, A.2    Descovich, M.3    Cho, Y.B.4    Chuang, C.5    Huang, K.6
  • 32
  • 33
    • 77954276166 scopus 로고    scopus 로고
    • Local disease control after decompressive surgery and adjuvant high-dose single-fraction radiosurgery for spine metastases. Clinical article
    • Moulding HD, Elder JB, Lis E, Lovelock DM, Zhang Z, Yamada Y, et al: Local disease control after decompressive surgery and adjuvant high-dose single-fraction radiosurgery for spine metastases. Clinical article. J Neurosurg Spine 13:87-93, 2010
    • (2010) J Neurosurg Spine , vol.13 , pp. 87-93
    • Moulding, H.D.1    Elder, J.B.2    Lis, E.3    Lovelock, D.M.4    Zhang, Z.5    Yamada, Y.6
  • 34
    • 33750707586 scopus 로고    scopus 로고
    • Technical description, phantom accuracy, and clinical feasibility for fiducial-free frameless real-time image-guided spinal radiosurgery
    • DOI 10.3171/spi.2006.5.4.303
    • Muacevic A, Staehler M, Drexler C, Wowra B, Reiser M, Tonn JC: Technical description, phantom accuracy, and clinical feasibility for fiducial-free frameless real-time image-guided spinal radiosurgery. J Neurosurg Spine 5:303-312, 2006 (Pubitemid 47325368)
    • (2006) Journal of Neurosurgery: Spine , vol.5 , Issue.4 , pp. 303-312
    • Muacevic, A.1    Staehler, M.2    Drexler, C.3    Wowra, B.4    Reiser, M.5    Tonn, J.-C.6
  • 37
    • 23844539714 scopus 로고    scopus 로고
    • Direct decompressive surgical resection in the treatment of spinal cord compression caused by metastatic cancer: A randomised trial
    • DOI 10.1016/S0140-6736(05)66954-1, PII S0140673605669541
    • Patchell RA, Tibbs PA, Regine WF, Payne R, Saris S, Kryscio RJ, et al: Direct decompressive surgical resection in the treatment of spinal cord compression caused by metastatic cancer: a randomised trial. Lancet 366:643-648, 2005 (Pubitemid 41176016)
    • (2005) Lancet , vol.366 , Issue.9486 , pp. 643-648
    • Patchell, R.A.1    Tibbs, P.A.2    Regine, W.F.3    Payne, R.4    Saris, S.5    Kryscio, R.J.6    Mohiuddin, M.7    Young, B.8
  • 38
    • 10744226022 scopus 로고    scopus 로고
    • Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63
    • DOI 10.1118/1.1565113
    • Reft C, Alecu R, Das IJ, Gerbi BJ, Keall P, Lief E, et al: Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63. Med Phys 30:1162-1182, 2003 (Pubitemid 36735983)
    • (2003) Medical Physics , vol.30 , Issue.6 , pp. 1162-1182
    • Reft, C.1    Alecu, R.2    Das, I.J.3    Gerbi, B.J.4    Keall, P.5    Lief, E.6    Mijnheer, B.J.7    Papanikolaou, N.8    Sibata, C.9    Van, D.J.10
  • 40
    • 46949103980 scopus 로고    scopus 로고
    • Technology insight: Image-guided robotic radiosurgery - A new approach for noninvasive ablation of spinal lesions
    • DOI 10.1038/ncponc1131, PII NCPONC1131
    • Romanelli P, Adler JR Jr: Technology Insight: image-guided robotic radiosurgery - a new approach for noninvasive ablation of spinal lesions. Nat Clin Pract Oncol 5:405-414, 2008 (Pubitemid 351958965)
    • (2008) Nature Clinical Practice Oncology , vol.5 , Issue.7 , pp. 405-414
    • Romanelli, P.1    Adler Jr., J.R.2
  • 41
    • 77649100060 scopus 로고    scopus 로고
    • Risk of fracture after single fraction image-guided intensity-modulated radiation therapy to spinal metastases
    • Rose PS, Laufer I, Boland PJ, Hanover A, Bilsky MH, Yamada J, et al: Risk of fracture after single fraction image-guided intensity-modulated radiation therapy to spinal metastases. J Clin Oncol 27:5075-5079, 2009
    • (2009) J Clin Oncol , vol.27 , pp. 5075-5079
    • Rose, P.S.1    Laufer, I.2    Boland, P.J.3    Hanover, A.4    Bilsky, M.H.5    Yamada, J.6
  • 43
    • 33846660974 scopus 로고    scopus 로고
    • Partial volume tolerance of the spinal cord and complications of single-dose radiosurgery
    • DOI 10.1002/cncr.22442
    • Ryu S, Jin JY, Jin R, Rock J, Ajlouni M, Movsas B, et al: Partial volume tolerance of the spinal cord and complications of single-dose radiosurgery. Cancer 109:628-636, 2007 (Pubitemid 46190973)
    • (2007) Cancer , vol.109 , Issue.3 , pp. 628-636
    • Ryu, S.1    Jin, J.-Y.2    Jin, R.3    Rock, J.4    Ajlouni, M.5    Movsas, B.6    Rosenblum, M.7    Kim, J.H.8
  • 44
    • 7244257471 scopus 로고    scopus 로고
    • Patterns of failure after single-dose radiosurgery for spinal metastasis
    • Ryu S, Rock J, Rosenblum M, Kim JH: Patterns of failure after single-dose radiosurgery for spinal metastasis. J Neurosurg 101 (Suppl 3):402-405, 2004 (Pubitemid 39430958)
    • (2004) Journal of Neurosurgery , vol.101 , Issue.SUPPL. 3 , pp. 402-405
    • Ryu, S.1    Rock, J.2    Rosenblum, M.3    Jae, H.K.4
  • 45
    • 67349260007 scopus 로고    scopus 로고
    • Stereotactic body radiotherapy is effective salvage therapy for patients with prior radiation of spinal metastases
    • Sahgal A, Ames C, Chou D, Ma L, Huang K, Xu W, et al: Stereotactic body radiotherapy is effective salvage therapy for patients with prior radiation of spinal metastases. Int J Radiat Oncol Biol Phys 74:723-731, 2009
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 723-731
    • Sahgal, A.1    Ames, C.2    Chou, D.3    Ma, L.4    Huang, K.5    Xu, W.6
  • 46
    • 37549056253 scopus 로고    scopus 로고
    • Image-guided robotic stereotactic body radiotherapy for benign spinal tumors: The University of California San Francisco preliminary experience
    • Sahgal A, Chou D, Ames C, Ma L, Lamborn K, Huang K, et al: Image-guided robotic stereotactic body radiotherapy for benign spinal tumors: the University of California San Francisco preliminary experience. Technol Cancer Res Treat 6:595-604, 2007
    • (2007) Technol Cancer Res Treat , vol.6 , pp. 595-604
    • Sahgal, A.1    Chou, D.2    Ames, C.3    Ma, L.4    Lamborn, K.5    Huang, K.6
  • 47
    • 77949357856 scopus 로고    scopus 로고
    • Comparisons of Novalis and Cyberknife spinal stereotactic body radiotherapy treatment planning based on physi cal and biological modeling parameters
    • McDermott MW, Sneed PK, Huang K, et al (eds): Basel: Karger
    • Sahgal A, Chuang C, Hossain S, Petti P, Larson DA, Shrieve DC: Comparisons of Novalis and Cyberknife spinal stereotactic body radiotherapy treatment planning based on physi cal and biological modeling parameters, in McDermott MW, Sneed PK, Huang K, et al (eds): Radiosurgery. Basel: Karger, Vol 7, 2010, pp 75-83
    • (2010) Radiosurgery , vol.7 , pp. 75-83
    • Sahgal, A.1    Chuang, C.2    Hossain, S.3    Petti, P.4    Larson, D.A.5    Shrieve, D.C.6
  • 53
    • 57049134717 scopus 로고    scopus 로고
    • Radiation for spinal metastatic tumors
    • vii
    • Swift PS: Radiation for spinal metastatic tumors. Orthop Clin North Am 40:133-144, vii, 2009
    • (2009) Orthop Clin North Am , vol.40 , pp. 133-144
    • Swift, P.S.1
  • 54
    • 61449259860 scopus 로고    scopus 로고
    • CyberKnife stereotactic radiotherapy for spinal tumors: Value of computed tomographic myelography in spinal cord delineation
    • Thariat J, Castelli J, Chanalet S, Marcie S, Mammar H, Bondiau PY: CyberKnife stereotactic radiotherapy for spinal tumors: value of computed tomographic myelography in spinal cord delineation. Neurosurgery 64 (2 Suppl):A60-A66, 2009
    • (2009) Neurosurgery , vol.64 , Issue.2 SUPPL.
    • Thariat, J.1    Castelli, J.2    Chanalet, S.3    Marcie, S.4    Mammar, H.5    Bondiau, P.Y.6
  • 55
    • 67650459109 scopus 로고    scopus 로고
    • Assessment of imageguided CyberKnife radiosurgery for metastatic spine tumors
    • Tsai JT, Lin JW, Chiu WT, Chu WC: Assessment of imageguided CyberKnife radiosurgery for metastatic spine tumors. J Neurooncol 94:119-127, 2009
    • (2009) J Neurooncol , vol.94 , pp. 119-127
    • Tsai, J.T.1    Lin, J.W.2    Chiu, W.T.3    Chu, W.C.4
  • 57
    • 34548426521 scopus 로고    scopus 로고
    • A review of image-guided intensity-modulated radiotherapy for spinal tumors
    • DOI 10.1227/01.NEU.0000279970.10309.B5, PII 0000612320070800000002
    • Yamada Y, Lovelock DM, Bilsky MH: A review of image-guided intensity-modulated radiotherapy for spinal tumors. Neurosurgery 61:226-235, 2007 (Pubitemid 47357283)
    • (2007) Neurosurgery , vol.61 , Issue.2 , pp. 226-235
    • Yamada, Y.1    Lovelock, D.M.2    Bilsky, M.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.