메뉴 건너뛰기




Volumn 37, Issue 11, 2010, Pages 5867-5875

Sinogram preprocessing and binary reconstruction for determination of the shape and location of metal objects in computed tomography (CT)

Author keywords

CT; image reconstruction; iterative method; metal artifacts; sparse projections

Indexed keywords

BINARY IMAGES; IMAGE RECONSTRUCTION; ITERATIVE METHODS; METALS; PROBABILITY DISTRIBUTIONS;

EID: 78149448356     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3505294     Document Type: Article
Times cited : (18)

References (21)
  • 1
    • 0030983762 scopus 로고    scopus 로고
    • Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction
    • DOI 10.1097/00004728-199703000-00024
    • D. D. Robertson, J. Yuan, G. Wang, and M. W. Vannier, " Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.," J. Comput. Assist. Tomogr. JCATD5 0363-8715 21 (2), 293-298 (1997). 10.1097/00004728-199703000-00024 (Pubitemid 27120036)
    • (1997) Journal of Computer Assisted Tomography , vol.21 , Issue.2 , pp. 293-298
    • Robertson, D.D.1    Yuan, J.2    Wang, G.3    Vannier, M.W.4
  • 2
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • RADLAX 0033-8419 ().
    • W. A. Kalender, R. Hebel, and J. Ebersberger, " Reduction of CT artifacts caused by metallic implants.," Radiology RADLAX 0033-8419 164 (2), 576-577 (1987).
    • (1987) Radiology , vol.164 , Issue.2 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 3
    • 75749108974 scopus 로고    scopus 로고
    • Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT
    • MPHYA6 0094-2405 (),. 10.1118/1.3276777
    • W. J. Veldkamp, R. M. Joemai, A. J. van der Molen, and J. Geleijns, " Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT.," Med. Phys. MPHYA6 0094-2405 37 (2), 620-628 (2010). 10.1118/1.3276777
    • (2010) Med. Phys. , vol.37 , Issue.2 , pp. 620-628
    • Veldkamp, W.J.1    Joemai, R.M.2    Van Der Molen, A.J.3    Geleijns, J.4
  • 4
    • 77950803934 scopus 로고    scopus 로고
    • Metal artifact reduction for clipping and coiling in interventional C-arm CT
    • ZZZZZZ 0195-6108 (),. 10.3174/ajnr.A1883
    • D. Prell, Y. Kyriakou, T. Struffert, A. Dorfler, and W. A. Kalender, " Metal artifact reduction for clipping and coiling in interventional C-arm CT.," AJNR Am. J. Neuroradiol. ZZZZZZ 0195-6108 31 (4), 634-639 (2009). 10.3174/ajnr.A1883
    • (2009) AJNR Am. J. Neuroradiol. , vol.31 , Issue.4 , pp. 634-639
    • Prell, D.1    Kyriakou, Y.2    Struffert, T.3    Dorfler, A.4    Kalender, W.A.5
  • 5
    • 74949099949 scopus 로고    scopus 로고
    • Imaging of patients having metal implant using x-ray computed tomography
    • JXSTE5 0895-3996 ().
    • J. J. Liu and J. E. Lutkin, " Imaging of patients having metal implant using x-ray computed tomography.," J. X-Ray Sci. Technol. JXSTE5 0895-3996 17 (4), 355-365 (2009).
    • (2009) J. X-Ray Sci. Technol. , vol.17 , Issue.4 , pp. 355-365
    • Liu, J.J.1    Lutkin, J.E.2
  • 6
    • 33746633331 scopus 로고    scopus 로고
    • Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    • DOI 10.1118/1.2218062
    • M. Bal and L. Spies, " Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering.," Med. Phys. MPHYA6 0094-2405 33 (8), 2852-2859 (2006). 10.1118/1.2218062 (Pubitemid 44154556)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2852-2859
    • Bal, M.1    Spies, L.2
  • 7
    • 0028446166 scopus 로고
    • Penalized weighted least-squares image-reconstruction for positron emission tomography
    • ITMID4 0278-0062 (),. 10.1109/42.293921
    • J. A. Fessler, " Penalized weighted least-squares image-reconstruction for positron emission tomography.," IEEE Trans. Med. Imaging ITMID4 0278-0062 13 (2), 290-300 (1994). 10.1109/42.293921
    • (1994) IEEE Trans. Med. Imaging , vol.13 , Issue.2 , pp. 290-300
    • Fessler, J.A.1
  • 8
    • 8344272167 scopus 로고    scopus 로고
    • Nonlinear sinogram smoothing for low-dose x-ray CT
    • IETNAE 0018-9499 (),. 10.1109/TNS.2004.834824
    • T. F. Li, X. Li, J. Wang, J. H. Wen, H. B. Lu, J. Hsieh, and Z. R. Liang, " Nonlinear sinogram smoothing for low-dose x-ray CT.," IEEE Trans. Nucl. Sci. IETNAE 0018-9499 51 (5), 2505-2513 (2004). 10.1109/TNS.2004.834824
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.5 , pp. 2505-2513
    • Li, T.F.1    Li, X.2    Wang, J.3    Wen, J.H.4    Lu, H.B.5    Hsieh, J.6    Liang, Z.R.7
  • 9
    • 58149141914 scopus 로고    scopus 로고
    • Iterative image reconstruction for CBCT using edge-preserving prior
    • MPHYA6 0094-2405 (),. 10.1118/1.3036112
    • J. Wang, T. Li, and L. Xing, " Iterative image reconstruction for CBCT using edge-preserving prior.," Med. Phys. MPHYA6 0094-2405 36 (1), 252-260 (2009). 10.1118/1.3036112
    • (2009) Med. Phys. , vol.36 , Issue.1 , pp. 252-260
    • Wang, J.1    Li, T.2    Xing, L.3
  • 10
    • 61349173033 scopus 로고    scopus 로고
    • Noise suppression in scatter correction for cone-beam CT
    • MPHYA6 0094-2405 (),. 10.1118/1.3063001
    • L. Zhu, J. Wang, and L. Xing, " Noise suppression in scatter correction for cone-beam CT.," Med. Phys. MPHYA6 0094-2405 36 (3), 741-752 (2009). 10.1118/1.3063001
    • (2009) Med. Phys. , vol.36 , Issue.3 , pp. 741-752
    • Zhu, L.1    Wang, J.2    Xing, L.3
  • 11
    • 21144458117 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram smoothing for low-dose CT
    • DOI 10.1118/1.1915015
    • P. J. La Rivìre, " Penalized-likelihood sinogram smoothing for low-dose CT.," Med. Phys. MPHYA6 0094-2405 32 (6), 1676-1683 (2005). 10.1118/1.1915015 (Pubitemid 40880561)
    • (2005) Medical Physics , vol.32 , Issue.6 , pp. 1676-1683
    • La Riviere, P.J.1
  • 12
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    • DOI 10.1109/TMI.2006.882141
    • J. Wang, T. Li, H. B. Lu, and Z. R. Liang, " Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose x-ray computed tomography.," IEEE Trans. Med. Imaging ITMID4 0278-0062 25 (10), 1272-1283 (2006). 10.1109/TMI.2006.882141 (Pubitemid 46417077)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.10 , pp. 1272-1283
    • Wang, J.1    Li, T.2    Lu, H.3    Liang, Z.4
  • 13
    • 45749103203 scopus 로고    scopus 로고
    • Dose reduction for kilovotage cone-beam computed tomography in radiation therapy
    • DOI 10.1088/0031-9155/53/11/009, PII S0031915508683785
    • J. Wang, T. Li, Z. Liang, and L. Xing, " Dose reduction for kilovotage cone-beam computed tomography in radiation therapy.," Phys. Med. Biol. PHMBA7 0031-9155 53 (11), 2897-2909 (2008). 10.1088/0031-9155/53/11/009 (Pubitemid 351868612)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 2897-2909
    • Wang, J.1    Li, T.2    Liang, Z.3    Xing, L.4
  • 14
    • 67649227120 scopus 로고    scopus 로고
    • Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: State of the art
    • ZZZZZZ 0940-6719,. 10.1007/s00586-009-0998-5
    • P. Stradiotti, A. Curti, G. Castellazzi, and A. Zerbi, " Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: State of the art.," Eur. Spine J. ZZZZZZ 0940-6719 18, 102-108 (2009). 10.1007/s00586-009-0998-5
    • (2009) Eur. Spine J. , vol.18 , pp. 102-108
    • Stradiotti, P.1    Curti, A.2    Castellazzi, G.3    Zerbi, A.4
  • 15
    • 14344266358 scopus 로고    scopus 로고
    • A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy
    • DOI 10.1016/j.brachy.2004.11.001
    • D. Xia, J. C. Roeske, L. Yu, C. A. Pelizzari, A. J. Mundt, and X. Pan, " A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy.," Brachytherapy BRACC4 1538-4721 4 (1), 18-23 (2005). 10.1016/j.brachy.2004.11.001 (Pubitemid 40292825)
    • (2005) Brachytherapy , vol.4 , Issue.1 , pp. 18-23
    • Xia, D.1    Roeske, J.C.2    Yu, L.3    Pelizzari, C.A.4    Mundt, A.J.5    Pan, X.6
  • 16
    • 1542328954 scopus 로고    scopus 로고
    • Reduction of computed tomography metal artifacts due to the Fletcher-Suit applicator in gynecology patients receiving intracavitary brachytherapy
    • DOI 10.1016/j.brachy.2003.08.001, PII S1538472103001363
    • J. C. Roeske, C. Lund, C. A. Pelizzari, X. Pan, and A. J. Mundt, " Reduction of computed tomography metal artifacts due to the Fletcher-Suit applicator in gynecology patients receiving intracavitary brachytherapy.," Brachytherapy BRACC4 1538-4721 2 (4), 207-214 (2003). 10.1016/j.brachy.2003.08. 001 (Pubitemid 38316784)
    • (2003) Brachytherapy , vol.2 , Issue.4 , pp. 207-214
    • Roeske, J.C.1    Lund, C.2    Pelizzari, C.A.3    Pan, X.4    Mundt, A.J.5
  • 18
    • 17844379967 scopus 로고    scopus 로고
    • Respiratory correlated cone beam CT
    • DOI 10.1118/1.1869074
    • J. J. Sonke, L. Zijp, P. Remeijer, and M. van Herk, " Respiratory correlated cone beam CT.," Med. Phys. MPHYA6 0094-2405 32 (4), 1176-1186 (2005). 10.1118/1.1869074 (Pubitemid 40590074)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 1176-1186
    • Sonke, J.-J.1    Zijp, L.2    Remeijer, P.3    Van Herk, M.4
  • 19
    • 33749387058 scopus 로고    scopus 로고
    • Four-dimensional cone-beam computed tomography using an on-board imager
    • DOI 10.1118/1.2349692
    • T. Li, L. Xing, C. McGuinness, P. Munro, B. Loo, and A. Koong, " Four-dimensional cone-beam CT using an on-board imager.," Med. Phys. MPHYA6 0094-2405 33, 3825-3833 (2006). 10.1118/1.2349692 (Pubitemid 44505107)
    • (2006) Medical Physics , vol.33 , Issue.10 , pp. 3825-3833
    • Li, T.1    Xing, L.2    Munro, P.3    McGuinness, C.4    Chao, M.5    Yang, Y.6    Loo, B.7    Koong, A.8
  • 20
    • 33847321630 scopus 로고    scopus 로고
    • Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy
    • IOBPD3 0360-3016 (),. 10.1016/j.ijrob2006.10.024
    • T. Li and L. Xing, " Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 67 (4), 1211-1219 (2007). 10.1016/j.ijrobp.2006.10.024
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.67 , Issue.4 , pp. 1211-1219
    • Li, T.1    Xing, L.2
  • 21
    • 34548304925 scopus 로고    scopus 로고
    • Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling
    • DOI 10.1118/1.2767145
    • J. Lu, T. M. Guerrero, P. Munro, A. Jeung, P. C. Chi, P. Balter, X. R. Zhu, R. Mohan, and T. Pan, " Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.," Med. Phys. MPHYA6 0094-2405 34 (9), 3520-3529 (2007). 10.1118/1.2767145 (Pubitemid 47339749)
    • (2007) Medical Physics , vol.34 , Issue.9 , pp. 3520-3529
    • Lu, J.1    Guerrero, T.M.2    Munro, P.3    Jeung, A.4    Chi, P.-C.M.5    Balter, P.6    Zhu, X.R.7    Mohan, R.8    Pan, T.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.