메뉴 건너뛰기




Volumn 225, Issue 1, 2011, Pages 25-37

Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with a non-spherical femoral bearing surface

Author keywords

Alpharabola surface; elastohydrodynamic lubrication; initial contact position; metal on metal hip prostheses; non spherical bearing surfaces

Indexed keywords

ALPHARABOLA SURFACE; ANTEVERSION ANGLES; BEARING SURFACES; EQUATORIAL REGIONS; FEMORAL COMPONENT; FEMORAL HEADS; GEOMETRIC VARIATIONS; INITIAL CONTACT POSITION; ISO STANDARDS; LUBRICATION PERFORMANCE; METAL-ON-METAL HIP IMPLANTS; METAL-ON-METAL HIP PROSTHESES; METAL-ON-METAL HIP PROSTHESIS; NON-SPHERICAL; NUMERICAL METHODOLOGIES; SPHERICAL BEARINGS; SQUEEZE FILMS; TRANSIENT ELASTOHYDRODYNAMIC LUBRICATION;

EID: 79551656506     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM795     Document Type: Article
Times cited : (13)

References (41)
  • 1
    • 0035045395 scopus 로고    scopus 로고
    • Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
    • Firkins, P. J., Tipper, J. L., Saadatzadeh, M. R., Ingham, E., Stone, M. H., Farrar, R., and Fisher, J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Bio-Med. Mater. Engng, 2001, 11(2), 143-157.
    • (2001) Bio-Med. Mater. Engng , vol.11 , Issue.2 , pp. 143-157
    • Firkins, P.J.1    Tipper, J.L.2    Saadatzadeh, M.R.3    Ingham, E.4    Stone, M.H.5    Farrar, R.6    Fisher, J.7
  • 3
    • 0019128573 scopus 로고
    • Metal-ion release after total hip-replacement
    • Dobbs, H. S. and Minski, M. J. Metal-ion release after total hip-replacement. Biomater., 1980, 1(4), 193-198.
    • (1980) Biomater. , vol.1 , Issue.4 , pp. 193-198
    • Dobbs, H.S.1    Minski, M.J.2
  • 7
    • 33645294041 scopus 로고    scopus 로고
    • Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses
    • DOI: 10.1243/095441105X63291
    • Brown, C., Fisher, J., and Ingham, E. Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(H2), 355-369. DOI: 10.1243/ 095441105X63291.
    • (2006) Proc. IMechE, Part H: J. Engineering in Medicine , vol.220 , Issue.H2 , pp. 355-369
    • Brown, C.1    Fisher, J.2    Ingham, E.3
  • 8
    • 33645234539 scopus 로고    scopus 로고
    • The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty
    • DOI: 10.1243/09544119JEIM78
    • Cobb, A. G. and Schmalzreid, T. P. The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(H2), 385-398. DOI: 10.1243/09544119JEIM78.
    • (2006) Proc. IMechE, Part H: J. Engineering in Medicine , vol.220 , Issue.H2 , pp. 385-398
    • Cobb, A.G.1    Schmalzreid, T.P.2
  • 9
    • 33645236920 scopus 로고    scopus 로고
    • Biological effects of metal-on-metal hip replacements
    • DOI: 10.1243/095441105X68971
    • Bhamra, M. S. and Case, C. P. Biological effects of metal-on-metal hip replacements. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(H2), 379-384. DOI: 10.1243/095441105X68971.
    • (2006) Proc. IMechE, Part H: J. Engineering in Medicine , vol.220 , Issue.H2 , pp. 379-384
    • Bhamra, M.S.1    Case, C.P.2
  • 11
    • 17044413641 scopus 로고    scopus 로고
    • Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants
    • Rieker, C., Schon, R., Konrad, R., Liebentritt, G., Gnepf, P., Shen, M., Roberts, P., and Grigoris, P. Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants. Orthop. Clinics N. Am., 2005, 36(2), 135-142.
    • (2005) Orthop. Clinics N. Am. , vol.36 , Issue.2 , pp. 135-142
    • Rieker, C.1    Schon, R.2    Konrad, R.3    Liebentritt, G.4    Gnepf, P.5    Shen, M.6    Roberts, P.7    Grigoris, P.8
  • 12
    • 33645216349 scopus 로고    scopus 로고
    • The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies
    • DOI: 10.1243/ 09544119JEIM63
    • Vassiliou, K., Elfick, A. P., Scholes, S. C., and Unsworth, A. The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(H2), 269-277. DOI: 10.1243/ 09544119JEIM63.
    • (2006) Proc. IMechE, Part H: J. Engineering in Medicine , vol.220 , Issue.H2 , pp. 269-277
    • Vassiliou, K.1    Elfick, A.P.2    Scholes, S.C.3    Unsworth, A.4
  • 14
    • 49849097214 scopus 로고    scopus 로고
    • Tribological considerations in primary and revision metal-on-metal arthroplasty
    • Lee, R., Essner, A., and Wang, A. Tribological considerations in primary and revision metal-on-metal arthroplasty. J. Bone Joint Surg., Am., 2008, 90(Suppl. 3), 118-124.
    • (2008) J. Bone Joint Surg. Am. , vol.90 , Issue.SUPPL. 3 , pp. 118-124
    • Lee, R.1    Essner, A.2    Wang, A.3
  • 15
    • 2542607724 scopus 로고    scopus 로고
    • Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses
    • Hu, X. Q., Isaac, G. H., and Fisher, J. Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses. Bio-Med. Mater. Engng, 2004, 14(2), 145-149.
    • (2004) Bio-Med. Mater. Engng , vol.14 , Issue.2 , pp. 145-149
    • Hu, X.Q.1    Isaac, G.H.2    Fisher, J.3
  • 16
    • 49849104468 scopus 로고    scopus 로고
    • Design considerations and life prediction of metal-on-metal bearings: The effect of clearance
    • Tuke, M. A., Scott, G., Roques, A., Hu, X. Q., and Taylor, A. Design considerations and life prediction of metal-on-metal bearings: the effect of clearance. J. Bone Joint Surg., Am., 2008, 90(Suppl. 3), 134-141.
    • (2008) J. Bone Joint Surg. Am. , vol.90 , Issue.SUPPL. 3 , pp. 134-141
    • Tuke, M.A.1    Scott, G.2    Roques, A.3    Hu, X.Q.4    Taylor, A.5
  • 18
    • 9644273921 scopus 로고    scopus 로고
    • A hip joint simulator study of the performance of metal-on-metal joints Part II: Design
    • Dowson, D., Hardaker, C., Flett, M., and Isaac, G.H. A hip joint simulator study of the performance of metal-on-metal joints, Part II: design. J. Arthroplasty, 2004, 19(8), S124-S130.
    • (2004) J. Arthroplasty , vol.19 , Issue.8
    • Dowson, D.1    Hardaker, C.2    Flett, M.3    Isaac, G.H.4
  • 19
    • 33749340043 scopus 로고    scopus 로고
    • Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing pros-theses
    • DOI: 10.1243/ 09544119JEIM172
    • Liu, F., Jin, Z. M., Roberts, P., and Grigoris, P. Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing pros-theses. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(H6), 695-704. DOI: 10.1243/ 09544119JEIM172.
    • (2006) Proc. IMechE, Part H: J. Engineering in Medicine , vol.220 , Issue.H6 , pp. 695-704
    • Liu, F.1    Jin, Z.M.2    Roberts, P.3    Grigoris, P.4
  • 23
    • 77549088281 scopus 로고    scopus 로고
    • Contact mechanics and elastohy-drodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing Surface
    • DOI: 10.1016/ j.jbiomech.2009.11.018
    • Meng, Q. E., Gao, L. M., Liu, F., Yang, P. R., Fisher, J., and Jin, Z. M. Contact mechanics and elastohy-drodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing Surface. J. Biomechanics, 2009, 43(5), 849-857. DOI: 10.1016/ j.jbiomech.2009.11.018.
    • (2009) J. Biomechanics , vol.43 , Issue.5 , pp. 849-857
    • Meng, Q.E.1    Gao, L.M.2    Liu, F.3    Yang, P.R.4    Fisher, J.5    Jin, Z.M.6
  • 24
    • 79551654506 scopus 로고    scopus 로고
    • Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with an aspherical acetabular bearing surface
    • Meng, Q. E., Gao, L. M., Liu, F., Yang, P. R., Fisher, J., and Jin, Z. M. Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with an aspherical acetabular bearing surface. J. Med. Biomechanics, 2009, 24(5), 352-362.
    • (2009) J. Med. Biomechanics , vol.24 , Issue.5 , pp. 352-362
    • Meng, Q.E.1    Gao, L.M.2    Liu, F.3    Yang, P.R.4    Fisher, J.5    Jin, Z.M.6
  • 25
    • 33645233305 scopus 로고    scopus 로고
    • Head replacement, head rotation, and surface damage effects on metal-on-metal total hip replacements: A hip simulator study
    • DOI: 10.1243/095441105X69097
    • Hardaker, C., Dowson, D., and Isaac, G. H. Head replacement, head rotation, and surface damage effects on metal-on-metal total hip replacements: a hip simulator study. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(2), 209-217. DOI: 10.1243/095441105X69097.
    • (2006) Proc. IMechE, Part H: J. Engineering in Medicine , vol.220 , Issue.2 , pp. 209-217
    • Hardaker, C.1    Dowson, D.2    Isaac, G.H.3
  • 29
    • 42149088232 scopus 로고    scopus 로고
    • Transient elastohydro-dynamic lubrication of hip joint implants
    • Wang, F. C. and Jin, Z. M. Transient elastohydro-dynamic lubrication of hip joint implants. Trans. ASME, J. Tribology, 2008, 130(1), 011007.
    • (2008) Trans. ASME, J. Tribology , vol.130 , Issue.1 , pp. 011007
    • Wang, F.C.1    Jin, Z.M.2
  • 31
    • 0017955148 scopus 로고
    • The rheology of synovial fluid and some potential synthetic lubricants for degenerate synovial joints
    • Cooke, A. V., Dowson, D., and Wright, V. The rheology of synovial fluid and some potential synthetic lubricants for degenerate synovial joints. Engng in Medicine, 1978, 7, 66-72.
    • (1978) Engng in Medicine , vol.7 , pp. 66-72
    • Cooke, A.V.1    Dowson, D.2    Wright, V.3
  • 32
    • 0042069555 scopus 로고    scopus 로고
    • The influence of lubricant and material on polymer/ CoCr sliding friction
    • Yao, J. Q., Laurent, M. P., Johnson, T. S., Blanchard, C. R., and Crowinshield, R. D. The influence of lubricant and material on polymer/ CoCr sliding friction. Wear, 2003, 255, 780-784.
    • (2003) Wear , Issue.255 , pp. 780-784
    • Yao, J.Q.1    Laurent, M.P.2    Johnson, T.S.3    Blanchard, C.R.4    Crowinshield, R.D.5
  • 35
    • 0036844166 scopus 로고    scopus 로고
    • Slide track analysis of eight contemporary hip simulator designs
    • Calonius, O. and Saikko, V. Slide track analysis of eight contemporary hip simulator designs. J. Bio-mechanics, 2002, 35(11), 1439-1450
    • (2002) J. Bio-mechanics , vol.35 , Issue.11 , pp. 1439-1450
    • Calonius, O.1    Saikko, V.2
  • 37
    • 67549137571 scopus 로고    scopus 로고
    • Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements
    • Gao, L. M., Wang, F. C., Yang, P. R., and Jin, Z. M. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements. Med. Engng Physics, 2009, 31(6), 720-729.
    • (2009) Med. Engng Physics , vol.31 , Issue.6 , pp. 720-729
    • Gao, L.M.1    Wang, F.C.2    Yang, P.R.3    Jin, Z.M.4
  • 39
    • 32644434964 scopus 로고    scopus 로고
    • Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions
    • Liu, F., Jin, Z. M., Hart, F., Rieker, C., and Roberts, P. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions. J. Biomechanics, 2006, 39(5), 905-914.
    • (2006) J. Biomechanics , vol.39 , Issue.5 , pp. 905-914
    • Liu, F.1    Jin, Z.M.2    Hart, F.3    Rieker, C.4    Roberts, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.