-
1
-
-
0026527380
-
Fat-suppression MR imaging in neuroradiology: Techniques and clinical application
-
Tien RD,. Fat-suppression MR imaging in neuroradiology: techniques and clinical application. Am J Roentgenol 1992; 158: 369-379.
-
(1992)
Am J Roentgenol
, vol.158
, pp. 369-379
-
-
Tien, R.D.1
-
2
-
-
0027208019
-
Detection of multiple myeloma involving the spine: Efficacy of fat-suppression and contrast-enhanced MR imaging
-
Rahmouni A, Divine M, Mathieu D, et al. Detection of multiple myeloma involving the spine: efficacy of fat-suppression and contrast-enhanced MR imaging. Am J Roentgenol 1993; 160: 1049-1052.
-
(1993)
Am J Roentgenol
, vol.160
, pp. 1049-1052
-
-
Rahmouni, A.1
Divine, M.2
Mathieu, D.3
-
3
-
-
1542375467
-
Whole spine MRI in the assessment of acute vertebral body trauma
-
Green RAR, Saifuddin A,. Whole spine MRI in the assessment of acute vertebral body trauma. Skeletal Radiol 2004; 33: 129-135.
-
(2004)
Skeletal Radiol
, vol.33
, pp. 129-135
-
-
Green, R.A.R.1
Saifuddin, A.2
-
4
-
-
53249133058
-
STIR sequence for depiction of degenerative changes in posterior stabilizing elements in patients with lower back pain
-
Lakadamyali H, Tarhan NC, Tarkan Ergun T, Cakr B, Aglder AM,. STIR sequence for depiction of degenerative changes in posterior stabilizing elements in patients with lower back pain. AJR Am J Roentgenol 2008; 191: 973-997.
-
(2008)
AJR Am J Roentgenol
, vol.191
, pp. 973-997
-
-
Lakadamyali, H.1
Tarhan, N.C.2
Tarkan Ergun, T.3
Cakr, B.4
Aglder, A.M.5
-
5
-
-
0033364294
-
Newer sequences for spinal MR imaging: Smorgasbord or succotash of acronyms?
-
Ross JS,. Newer sequences for spinal MR imaging: smorgasbord or succotash of acronyms? Am J Neuroradiol 1999; 20: 361-373.
-
(1999)
Am J Neuroradiol
, vol.20
, pp. 361-373
-
-
Ross, J.S.1
-
6
-
-
0035130844
-
Cervical spine: Three-dimensional fast spin-echo MR imaging-improved recovery of longitudinal magnetization with driven equilibrium pulse
-
Melhem ER, Itoh R, Folkers PJM,. Cervical spine: three-dimensional fast spin-echo MR imaging-improved recovery of longitudinal magnetization with driven equilibrium pulse. Radiology 2001; 218: 283-288.
-
(2001)
Radiology
, vol.218
, pp. 283-288
-
-
Melhem, E.R.1
Itoh, R.2
Folkers, P.J.M.3
-
7
-
-
0021967474
-
Chemical shift selective MR imaging using a whole-body magnet
-
Frahm J, Haase A, Hanicke W, Matthaei D, Bomsdorf H, Helzel T,. Chemical shift selective MR imaging using a whole-body magnet. Radiology 1985; 156: 441-444.
-
(1985)
Radiology
, vol.156
, pp. 441-444
-
-
Frahm, J.1
Haase, A.2
Hanicke, W.3
Matthaei, D.4
Bomsdorf, H.5
Helzel, T.6
-
9
-
-
0022260365
-
MR imaging: Clinical use of the inversion recovery sequence
-
Bydder GM, Young IR,. MR imaging: clinical use of the inversion recovery sequence. J Comput Assist Tomogr 1985; 9: 659-675.
-
(1985)
J Comput Assist Tomogr
, vol.9
, pp. 659-675
-
-
Bydder, G.M.1
Young, I.R.2
-
10
-
-
0028351561
-
Inversion in the steady state: Contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery-prepared GRE pulse sequences
-
Foo TK, Sawyer AM, Faulkner WH, Mills DG,. Inversion in the steady state: contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery-prepared GRE pulse sequences. Radiology 1994; 191: 85-90.
-
(1994)
Radiology
, vol.191
, pp. 85-90
-
-
Foo, T.K.1
Sawyer, A.M.2
Faulkner, W.H.3
Mills, D.G.4
-
11
-
-
0033087272
-
Fat suppression in MR imaging: Techniques and pitfalls
-
Delfaut EM, Beltran J, Johnson G, Rousseau J, Marchandise X, Cotteb A,. Fat suppression in MR imaging: techniques and pitfalls. Radiographics 1999; 19: 373-382.
-
(1999)
Radiographics
, vol.19
, pp. 373-382
-
-
Delfaut, E.M.1
Beltran, J.2
Johnson, G.3
Rousseau, J.4
Marchandise, X.5
Cotteb, A.6
-
12
-
-
0021132985
-
Simple proton spectroscopic imaging
-
Dixon WT,. Simple proton spectroscopic imaging. Radiology 1984; 153: 189-194.
-
(1984)
Radiology
, vol.153
, pp. 189-194
-
-
Dixon, W.T.1
-
13
-
-
0025831477
-
Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction
-
Glover GH, Schneider E,. Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction. Magn Reson Med 1991; 18: 371-383.
-
(1991)
Magn Reson Med
, vol.18
, pp. 371-383
-
-
Glover, G.H.1
Schneider, E.2
-
14
-
-
0026216918
-
Multipoint Dixon technique for water and fat proton and susceptibility imaging
-
Glover GH,. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991; 1: 521-530.
-
(1991)
J Magn Reson Imaging
, vol.1
, pp. 521-530
-
-
Glover, G.H.1
-
15
-
-
0029269157
-
Separation of fat and water in fast spin-echo MR imaging with the three-point Dixon technique
-
Hardy PA, Hinks RS, Tkach JA,. Separation of fat and water in fast spin-echo MR imaging with the three-point Dixon technique. J Magn Reson Imaging 1995; 5: 181-185.
-
(1995)
J Magn Reson Imaging
, vol.5
, pp. 181-185
-
-
Hardy, P.A.1
Hinks, R.S.2
Tkach, J.A.3
-
16
-
-
0034773525
-
Fast three-point Dixon MR imaging using low-resolution images for phase correction: A comparison with chemical shift selective fat suppression for pediatric musculoskeletal imaging
-
Rybicki FJ, Chung T, Reid J, Jaramillo D, Mulkern RV, Ma J,. Fast three-point Dixon MR imaging using low-resolution images for phase correction: a comparison with chemical shift selective fat suppression for pediatric musculoskeletal imaging. AJR Am J Roentgenol 2001; 177: 1019-1023.
-
(2001)
AJR Am J Roentgenol
, vol.177
, pp. 1019-1023
-
-
Rybicki, F.J.1
Chung, T.2
Reid, J.3
Jaramillo, D.4
Mulkern, R.V.5
Ma, J.6
-
17
-
-
34547736137
-
Fast spin-echo triple-echo Dixon (FTED) technique for efficient T2-weighted water and fat imaging
-
Ma J, Son JB, Zhou Y, Le-Petross H, Choi H,. Fast spin-echo triple-echo Dixon (FTED) technique for efficient T2-weighted water and fat imaging. Magn Reson Med 2007; 58: 103-109.
-
(2007)
Magn Reson Med
, vol.58
, pp. 103-109
-
-
Ma, J.1
Son, J.B.2
Zhou, Y.3
Le-Petross, H.4
Choi, H.5
-
18
-
-
3543083453
-
Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm
-
Ma J,. Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm. Magn Reson Med 2004; 52: 415-419.
-
(2004)
Magn Reson Med
, vol.52
, pp. 415-419
-
-
Ma, J.1
-
19
-
-
29244446245
-
A fast spin echo two-point dixon technique and its combination with sensitivity encoding for efficient T2-weighted Imaging
-
Ma J, Son JB, Bankson JA, Stafford RJ, Choi H, Ragan D,. A fast spin echo two-point dixon technique and its combination with sensitivity encoding for efficient T2-weighted Imaging. Magn Reson Imaging 2005; 23: 977-982.
-
(2005)
Magn Reson Imaging
, vol.23
, pp. 977-982
-
-
Ma, J.1
Son, J.B.2
Bankson, J.A.3
Stafford, R.J.4
Choi, H.5
Ragan, D.6
-
20
-
-
0036893691
-
Method for efficient fast spin echo Dixon imaging
-
Ma J, Singh SK, Kumar AJ, Leeds NE, Broemeling LD,. Method for efficient fast spin echo Dixon imaging. Magn Reson Med 2002; 48: 1021-1027.
-
(2002)
Magn Reson Med
, vol.48
, pp. 1021-1027
-
-
Ma, J.1
Singh, S.K.2
Kumar, A.J.3
Leeds, N.E.4
Broemeling, L.D.5
-
21
-
-
9644291523
-
T2-weighted spine imaging with a fast three-point Dixon technique: Comparison with chemical shift selective fat suppression
-
Ma J, Singh SK, Kumar AJ, Leeds NE, Zhan J,. T2-weighted spine imaging with a fast three-point Dixon technique: comparison with chemical shift selective fat suppression. J Magn Reson Imaging 2004; 20: 1025-1029.
-
(2004)
J Magn Reson Imaging
, vol.20
, pp. 1025-1029
-
-
Ma, J.1
Singh, S.K.2
Kumar, A.J.3
Leeds, N.E.4
Zhan, J.5
-
22
-
-
69449108412
-
Fast spin-echo triple-echo Dixon: Initial clinical experience with a novel pulse sequence for fat-suppressed T2-weighted abdominal MR imaging
-
Low RN, Ma J, Panchal N,. Fast spin-echo triple-echo Dixon: initial clinical experience with a novel pulse sequence for fat-suppressed T2-weighted abdominal MR imaging. J Magn Reson Imaging 2009; 30: 569-577.
-
(2009)
J Magn Reson Imaging
, vol.30
, pp. 569-577
-
-
Low, R.N.1
Ma, J.2
Panchal, N.3
-
23
-
-
23244463430
-
Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): Application with fast spin-echo imaging
-
Reeder SB, Pineda AR, Wen Z, et al. Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging. Magn Reson Imaging 2005; 54: 636-644.
-
(2005)
Magn Reson Imaging
, vol.54
, pp. 636-644
-
-
Reeder, S.B.1
Pineda, A.R.2
Wen, Z.3
-
24
-
-
33847616088
-
Water-fat separation with IDEAL gradient-echo imaging
-
,.
-
Reeder SB, McKenzie CA, Pineda AR, et al, Water-fat separation with IDEAL gradient-echo imaging. J Magn Reson Imaging 2007; 25: 644-652.
-
(2007)
J Magn Reson Imaging
, vol.25
, pp. 644-652
-
-
Reeder, S.B.1
McKenzie, C.A.2
Pineda, A.R.3
-
25
-
-
42449130436
-
Body MRI using IDEAL
-
Costa DN, Pedrosa I, McKenzie C, Reeder SB, Neil M, Rofsky NM,. Body MRI using IDEAL. Am J Roentgenol 2008; 190: 1076-1084.
-
(2008)
Am J Roentgenol
, vol.190
, pp. 1076-1084
-
-
Costa, D.N.1
Pedrosa, I.2
McKenzie, C.3
Reeder, S.B.4
Neil, M.5
Rofsky, N.M.6
-
26
-
-
32544434228
-
Single acquisition water-fat separation: Feasability study for dynamic imaging
-
Yu H, Reeder SB, McKenzie CA, et al. Single acquisition water-fat separation: feasability study for dynamic imaging. Magn Reson Med 2006; 55: 413-422.
-
(2006)
Magn Reson Med
, vol.55
, pp. 413-422
-
-
Yu, H.1
Reeder, S.B.2
McKenzie, C.A.3
-
27
-
-
53549084058
-
Three-dimensional fast spoiled gradient-echo dual echo (3D-FSPGR-DE) with water reconstruction: Preliminary experience with a novel pulse sequence for gadolinium-enhanced abdominal MR imaging
-
Low RN, Panchal N, Vu AT, et al. Three-dimensional fast spoiled gradient-echo dual echo (3D-FSPGR-DE) with water reconstruction: preliminary experience with a novel pulse sequence for gadolinium-enhanced abdominal MR imaging. J Magn Reson Imaging 2008; 28: 946-956.
-
(2008)
J Magn Reson Imaging
, vol.28
, pp. 946-956
-
-
Low, R.N.1
Panchal, N.2
Vu, A.T.3
-
28
-
-
30744448686
-
Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI
-
Ma J, Vu AT, Son JB, Choi H, Hazle JD,. Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI. J Magn Reson Imaging 2006; 23: 36-41.
-
(2006)
J Magn Reson Imaging
, vol.23
, pp. 36-41
-
-
Ma, J.1
Vu, A.T.2
Son, J.B.3
Choi, H.4
Hazle, J.D.5
-
29
-
-
46849105029
-
Pelvic imaging using a T1W fat-suppressed three-dimensional dual echo Dixon technique at 3T
-
Cornfeld DM, Israel G, McCarthy SM, Weinreb JC,. Pelvic imaging using a T1W fat-suppressed three-dimensional dual echo Dixon technique at 3T. J Magn Reson Imaging 2008; 28121-127.
-
(2008)
J Magn Reson Imaging
, pp. 28121-28127
-
-
Cornfeld, D.M.1
Israel, G.2
McCarthy, S.M.3
Weinreb, J.C.4
|