-
1
-
-
0036892244
-
Remote control of catheter tip deflection: an opportunity for interventional MRI
-
Roberts T.P., Hassenzahl W.V., Hetts S.W., et al. Remote control of catheter tip deflection: an opportunity for interventional MRI. Magn Reson Med 2002, 48:1091-1095.
-
(2002)
Magn Reson Med
, vol.48
, pp. 1091-1095
-
-
Roberts, T.P.1
Hassenzahl, W.V.2
Hetts, S.W.3
-
2
-
-
34547408460
-
Magnetically-assisted remote control (MARC) steering of endovascular catheters for interventional MRI: a model for deflection and design implications
-
Settecase F., Sussman M.S., Wilson M.W., et al. Magnetically-assisted remote control (MARC) steering of endovascular catheters for interventional MRI: a model for deflection and design implications. Med Phys 2007, 34:3135-3142.
-
(2007)
Med Phys
, vol.34
, pp. 3135-3142
-
-
Settecase, F.1
Sussman, M.S.2
Wilson, M.W.3
-
3
-
-
79551551142
-
Steerable catheter microcoils for interventional MRI: reducing resistive heating
-
Bernhardt A., Wilson M.W., Settecase F., et al. Steerable catheter microcoils for interventional MRI: reducing resistive heating. Acad Radiol 2011, 18:270-276.
-
(2011)
Acad Radiol
, vol.18
, pp. 270-276
-
-
Bernhardt, A.1
Wilson, M.W.2
Settecase, F.3
-
4
-
-
0034070037
-
Reduction of resonant RF heating in intravascular catheters using coaxial chokes
-
Ladd M.E., Quick H.H. Reduction of resonant RF heating in intravascular catheters using coaxial chokes. Magn Reson Med 2000, 43:615-619.
-
(2000)
Magn Reson Med
, vol.43
, pp. 615-619
-
-
Ladd, M.E.1
Quick, H.H.2
-
6
-
-
0035172358
-
On the heating of linear conductive structures as guide wires and catheters in interventional MRI
-
Nitz W.R., Oppelt A., Renz W., et al. On the heating of linear conductive structures as guide wires and catheters in interventional MRI. J Magn Reson Imaging 2001, 13:105-114.
-
(2001)
J Magn Reson Imaging
, vol.13
, pp. 105-114
-
-
Nitz, W.R.1
Oppelt, A.2
Renz, W.3
-
7
-
-
0033945858
-
Heating around intravascular guidewires by resonating RF waves
-
Konings M.K., Bartels L.W., Smits H.F., et al. Heating around intravascular guidewires by resonating RF waves. J Magn Reson Imaging 2000, 12:79-85.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 79-85
-
-
Konings, M.K.1
Bartels, L.W.2
Smits, H.F.3
-
8
-
-
0035085031
-
Investigation of the factors responsible for burns during MRI
-
Dempsey M.F., Condon B., Hadley D.M. Investigation of the factors responsible for burns during MRI. J Magn Reson Imaging 2001, 13:627-631.
-
(2001)
J Magn Reson Imaging
, vol.13
, pp. 627-631
-
-
Dempsey, M.F.1
Condon, B.2
Hadley, D.M.3
-
9
-
-
0036892879
-
RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field
-
Yeung C.J., Susil R.C., Atalar E. RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field. Magn Reson Med 2002, 48:1096-1098.
-
(2002)
Magn Reson Med
, vol.48
, pp. 1096-1098
-
-
Yeung, C.J.1
Susil, R.C.2
Atalar, E.3
-
10
-
-
0033934446
-
RF transmit power limit for the barewire loopless catheter antenna
-
Yeung C.J., Atalar E. RF transmit power limit for the barewire loopless catheter antenna. J Magn Reson Imaging 2000, 12:86-91.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 86-91
-
-
Yeung, C.J.1
Atalar, E.2
-
11
-
-
0036890783
-
Development of an intravascular heating source using an MR imaging guidewire
-
Qiu B., Yeung C.J., Du X., et al. Development of an intravascular heating source using an MR imaging guidewire. J Magn Reson Imaging 2002, 16:716-720.
-
(2002)
J Magn Reson Imaging
, vol.16
, pp. 716-720
-
-
Qiu, B.1
Yeung, C.J.2
Du, X.3
-
12
-
-
0033918247
-
Radiofrequency energy-induced heating during MR procedures: a review
-
Shellock F.G. Radiofrequency energy-induced heating during MR procedures: a review. J Magn Reson Imaging 2000, 12:30-36.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 30-36
-
-
Shellock, F.G.1
-
13
-
-
0036829965
-
Magnetic resonance safety update 2002: implants and devices
-
Shellock F.G. Magnetic resonance safety update 2002: implants and devices. J Magn Reson Imaging 2002, 16:485-496.
-
(2002)
J Magn Reson Imaging
, vol.16
, pp. 485-496
-
-
Shellock, F.G.1
-
14
-
-
0026646717
-
Current FDA guidance for MR patient exposure and considerations for the future
-
Athey T.W. Current FDA guidance for MR patient exposure and considerations for the future. Ann N Y Acad Sci 1992, 649:242-257.
-
(1992)
Ann N Y Acad Sci
, vol.649
, pp. 242-257
-
-
Athey, T.W.1
-
15
-
-
0031662758
-
MR-guided percutaneous angioplasty: assessment of tracking safety, catheter handling and functionality
-
Wildermuth S., Dumoulin C.L., Pfammatter T., et al. MR-guided percutaneous angioplasty: assessment of tracking safety, catheter handling and functionality. Cardiovasc Intervent Radiol 1998, 21:404-410.
-
(1998)
Cardiovasc Intervent Radiol
, vol.21
, pp. 404-410
-
-
Wildermuth, S.1
Dumoulin, C.L.2
Pfammatter, T.3
-
16
-
-
0036136666
-
RF safety of wires in interventional MRI: using a safety index
-
Yeung C.J., Susil R.C., Atalar E. RF safety of wires in interventional MRI: using a safety index. Magn Reson Med 2002, 47:187-193.
-
(2002)
Magn Reson Med
, vol.47
, pp. 187-193
-
-
Yeung, C.J.1
Susil, R.C.2
Atalar, E.3
-
19
-
-
0033917568
-
Safety of MRI-guided endovascular guidewire applications
-
Liu C.Y., Farahani K., Lu D.S., et al. Safety of MRI-guided endovascular guidewire applications. J Magn Reson Imaging 2000, 12:75-78.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 75-78
-
-
Liu, C.Y.1
Farahani, K.2
Lu, D.S.3
-
20
-
-
0343612870
-
-
MAGMA, Brussels, Belgium
-
Quick H.H., Ladd M.E., von Schulthess G.K., et al. Heating effects of an intravascular imaging catheter 1997, MAGMA, Brussels, Belgium.
-
(1997)
Heating effects of an intravascular imaging catheter
-
-
Quick, H.H.1
Ladd, M.E.2
von Schulthess, G.K.3
-
21
-
-
79551509825
-
-
Evaluation of RF and resistive heating due to magnetically-assisted remote control (MARC) steering coils for endovascular interventional MRI. Presented at: 16th Annual Meeting of the ISMRM; Toronto, ON, Canada.
-
Settecase F, Sussman MS, Wilson MW, et al. Evaluation of RF and resistive heating due to magnetically-assisted remote control (MARC) steering coils for endovascular interventional MRI. Presented at: 16th Annual Meeting of the ISMRM; Toronto, ON, Canada; 2008.
-
(2008)
-
-
Settecase, F.1
Sussman, M.S.2
Wilson, M.W.3
-
22
-
-
21244494388
-
Transmission line for improved RF safety of interventional devices
-
Weiss S., Vernickel P., Schaeffter T., et al. Transmission line for improved RF safety of interventional devices. Magn Reson Med 2005, 54:182-189.
-
(2005)
Magn Reson Med
, vol.54
, pp. 182-189
-
-
Weiss, S.1
Vernickel, P.2
Schaeffter, T.3
-
23
-
-
7544239159
-
RF-induced temperature elevation along metallic wires in clinical magnetic resonance imaging: influence of diameter and length
-
Armenean C., Perrin E., Armenean M., et al. RF-induced temperature elevation along metallic wires in clinical magnetic resonance imaging: influence of diameter and length. Magn Reson Med 2004, 52:1200-1206.
-
(2004)
Magn Reson Med
, vol.52
, pp. 1200-1206
-
-
Armenean, C.1
Perrin, E.2
Armenean, M.3
|