메뉴 건너뛰기




Volumn 172, Issue 1, 2011, Pages 193-198

A simple poly(dimethylsiloxane) electrophoresis microchip with an integrated contactless conductivity detector

Author keywords

Contactless conductivity detection; Multiplier; PDMS microchip; Rectifier

Indexed keywords


EID: 79251623551     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-010-0482-2     Document Type: Article
Times cited : (16)

References (22)
  • 1
    • 11944262834 scopus 로고
    • Capillary electrophoresis and sample injection systems integrated on a planar glass chip
    • Harrison DJ, Manz A, Fan ZH, Lüdi H, Widmer HM (1992) Capillary electrophoresis and sample injection systems integrated on a planar glass chip. Anal Chem 64: 1926-1932.
    • (1992) Anal Chem , vol.64 , pp. 1926-1932
    • Harrison, D.J.1    Manz, A.2    Fan, Z.H.3    Lüdi, H.4    Widmer, H.M.5
  • 2
    • 0038116768 scopus 로고    scopus 로고
    • Molecular diagnostics on electrophoretic microchips
    • Landers JP (2003) Molecular diagnostics on electrophoretic microchips. Anal Chem 75: 2919-2927.
    • (2003) Anal Chem , vol.75 , pp. 2919-2927
    • Landers, J.P.1
  • 3
    • 30144439538 scopus 로고    scopus 로고
    • Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection
    • Chen G, Lin Y, Wang J (2006) Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection. Talanta 68: 497-503.
    • (2006) Talanta , vol.68 , pp. 497-503
    • Chen, G.1    Lin, Y.2    Wang, J.3
  • 4
    • 33748348843 scopus 로고    scopus 로고
    • An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on-line optical detection
    • Huang FC, Liao CS, Lee GB (2006) An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on-line optical detection. Electrophoresis 27: 3297-3305.
    • (2006) Electrophoresis , vol.27 , pp. 3297-3305
    • Huang, F.C.1    Liao, C.S.2    Lee, G.B.3
  • 6
    • 38349125612 scopus 로고    scopus 로고
    • Advances in amperometric and conductometric detection in capillary and chip-based electrophoresis
    • Matysik FM (2008) Advances in amperometric and conductometric detection in capillary and chip-based electrophoresis. Microchim Acta 160: 1-14.
    • (2008) Microchim Acta , vol.160 , pp. 1-14
    • Matysik, F.M.1
  • 7
    • 36549062555 scopus 로고    scopus 로고
    • Contactless conductivity detection for microfluidics: designs and applications
    • Pumera M (2007) Contactless conductivity detection for microfluidics: designs and applications. Talanta 74: 358-364.
    • (2007) Talanta , vol.74 , pp. 358-364
    • Pumera, M.1
  • 8
    • 0542397711 scopus 로고    scopus 로고
    • An oscillometric detector for capillary electrophoresis
    • da Silva JAF, do Lago CL (1998) An oscillometric detector for capillary electrophoresis. Anal Chem 70: 4339-4343.
    • (1998) Anal Chem , vol.70 , pp. 4339-4343
    • da Silva, J.A.F.1    do Lago, C.L.2
  • 9
    • 70849121904 scopus 로고    scopus 로고
    • A compact and high-resolution version of a capacitively coupled contactless conductivity detector
    • Francisco KJM, do Lago CL (2009) A compact and high-resolution version of a capacitively coupled contactless conductivity detector. Electrophoresis 30: 3458-3464.
    • (2009) Electrophoresis , vol.30 , pp. 3458-3464
    • Francisco, K.J.M.1    do Lago, C.L.2
  • 11
    • 0036863537 scopus 로고    scopus 로고
    • A microchip electrophoresis system with integrated in-plane electrodes for contactless conductivity detection
    • Lichtenberg J, de Rooij NF, Verpoorte E (2002) A microchip electrophoresis system with integrated in-plane electrodes for contactless conductivity detection. Electrophoresis 23: 3769-3780.
    • (2002) Electrophoresis , vol.23 , pp. 3769-3780
    • Lichtenberg, J.1    de Rooij, N.F.2    Verpoorte, E.3
  • 12
    • 27344457559 scopus 로고    scopus 로고
    • Expanded electrical model of a contactless conductivity detector: development and verification
    • Johnston SE, Fadgen KE, Tolley LT, Jorgenson JW (2005) Expanded electrical model of a contactless conductivity detector: development and verification. J Chromatogr A 1094: 148-157.
    • (2005) J Chromatogr A , vol.1094 , pp. 148-157
    • Johnston, S.E.1    Fadgen, K.E.2    Tolley, L.T.3    Jorgenson, J.W.4
  • 13
    • 0035984039 scopus 로고    scopus 로고
    • Poly(dimethylsiloxane) as a material for fabricating microfluidic devices
    • McDonald JC, Whitesides GM (2002) Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. Acc Chem Res 35: 491-499.
    • (2002) Acc Chem Res , vol.35 , pp. 491-499
    • McDonald, J.C.1    Whitesides, G.M.2
  • 14
    • 0033987407 scopus 로고    scopus 로고
    • Electrokinetic control of fluid flow in native poly(dimethylsiloxane) capillary electrophoresis devices
    • Ocvirk G, Munroe M, Tang T, Oleschuk R, Westra K, Harrison DJ (2000) Electrokinetic control of fluid flow in native poly(dimethylsiloxane) capillary electrophoresis devices. Electrophoresis 21: 107-115.
    • (2000) Electrophoresis , vol.21 , pp. 107-115
    • Ocvirk, G.1    Munroe, M.2    Tang, T.3    Oleschuk, R.4    Westra, K.5    Harrison, D.J.6
  • 15
    • 33745700427 scopus 로고    scopus 로고
    • Controlling electroosmotic flow in poly(dimethylsiloxane) separation channels by means of prepolymer additives
    • Luo Y, Huang B, Wu H, Zare RN (2006) Controlling electroosmotic flow in poly(dimethylsiloxane) separation channels by means of prepolymer additives. Anal Chem 78: 4588-4592.
    • (2006) Anal Chem , vol.78 , pp. 4588-4592
    • Luo, Y.1    Huang, B.2    Wu, H.3    Zare, R.N.4
  • 17
    • 77949708383 scopus 로고    scopus 로고
    • Capacitively coupled contactless conductivity detection with dual top-bottom cell configuration for microchip electrophoresis
    • Mahabadi KA, Rodriguez I, Lim CY, Maurya DK, Hauser PC, de Rooij NF (2010) Capacitively coupled contactless conductivity detection with dual top-bottom cell configuration for microchip electrophoresis. Electrophoresis 31: 1-8.
    • (2010) Electrophoresis , vol.31 , pp. 1-8
    • Mahabadi, K.A.1    Rodriguez, I.2    Lim, C.Y.3    Maurya, D.K.4    Hauser, P.C.5    de Rooij, N.F.6
  • 18
    • 57349125781 scopus 로고    scopus 로고
    • A glass/PDMS hybrid microfluidic chip embedded with integrated electrodes for contactless conductivity detection
    • Li OL, Tong YL, Chen ZG, Liu C, Zhao S, Mo JY (2008) A glass/PDMS hybrid microfluidic chip embedded with integrated electrodes for contactless conductivity detection. Chromatographia 68: 1039-1044.
    • (2008) Chromatographia , vol.68 , pp. 1039-1044
    • Li, O.L.1    Tong, Y.L.2    Chen, Z.G.3    Liu, C.4    Zhao, S.5    Mo, J.Y.6
  • 19
    • 77149153677 scopus 로고    scopus 로고
    • Dual contactless conductivity and amperometric detection on hybrid PDMS/glass electrophoresis microchips
    • Vázquez M, Frankenfeld C, Coltro WKT, Carrilho E, Diamond D, Lunte SM (2010) Dual contactless conductivity and amperometric detection on hybrid PDMS/glass electrophoresis microchips. Analyst 135: 96-103.
    • (2010) Analyst , vol.135 , pp. 96-103
    • Vázquez, M.1    Frankenfeld, C.2    Coltro, W.K.T.3    Carrilho, E.4    Diamond, D.5    Lunte, S.M.6
  • 20
    • 45749134231 scopus 로고    scopus 로고
    • Fabrication and integration of planar electrodes for contactless conductivity detection on polyester-toner electrophoresis microchips
    • Coltro WKT, da Silva JAF, Carrilho E (2008) Fabrication and integration of planar electrodes for contactless conductivity detection on polyester-toner electrophoresis microchips. Electrophoresis 29: 2260-2265.
    • (2008) Electrophoresis , vol.29 , pp. 2260-2265
    • Coltro, W.K.T.1    da Silva, J.A.F.2    Carrilho, E.3
  • 21
    • 9144259579 scopus 로고    scopus 로고
    • Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part I: Frequency behavior and cell geometry
    • Kubáň P, Hauser PC (2004) Fundamental aspects of contactless conductivity detection for capillary electrophoresis. Part I: Frequency behavior and cell geometry. Electrophoresis 25: 3387-3397.
    • (2004) Electrophoresis , vol.25 , pp. 3387-3397
    • Kubáň, P.1    Hauser, P.C.2
  • 22
    • 0037115381 scopus 로고    scopus 로고
    • High-voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis
    • Tanyaniwa J, Hauser PC (2002) High-voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis. Anal Chem 74: 6378-6382.
    • (2002) Anal Chem , vol.74 , pp. 6378-6382
    • Tanyaniwa, J.1    Hauser, P.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.