메뉴 건너뛰기




Volumn 42, Issue 3, 2011, Pages 230-237

Setting acceptance criteria for validation of analytical methods of drug eluting stents: Minimum requirements for analytical variability

Author keywords

Acceptance criteria; Assay variability; Drug eluting stent; Method validation; Random error; Sigma approach; Systematic error

Indexed keywords

ANALYTIC METHOD; ARTICLE; DRUG ELUTING STENT; HISTOGRAM; MONTE CARLO METHOD; PRIORITY JOURNAL; VALIDATION STUDY;

EID: 79251593615     PISSN: 09280987     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejps.2010.11.013     Document Type: Article
Times cited : (9)

References (35)
  • 1
    • 33646253673 scopus 로고    scopus 로고
    • The future of drug eluting stents
    • R.R. Anis, and K.R. Karsch The future of drug eluting stents Heart 92 2006 585 588
    • (2006) Heart , vol.92 , pp. 585-588
    • Anis, R.R.1    Karsch, K.R.2
  • 7
    • 48949120802 scopus 로고    scopus 로고
    • Application of design of experiment (DOE) techniques to process validation in medical device manufacture
    • D. Dixon, J. Eatock, B.J. Meenan, and M. Morgan Application of design of experiment (DOE) techniques to process validation in medical device manufacture J. Valid. Tech. 12 2006 92 100
    • (2006) J. Valid. Tech. , vol.12 , pp. 92-100
    • Dixon, D.1    Eatock, J.2    Meenan, B.J.3    Morgan, M.4
  • 8
    • 77953453062 scopus 로고    scopus 로고
    • Next generation drug-eluting stents: Focus on bioabsorbable platforms and polymers
    • B. Doyle, and D.R. Holmes Jr. Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers Med. Device: Evid. Res. 2 2009 47 55
    • (2009) Med. Device: Evid. Res. , vol.2 , pp. 47-55
    • Doyle, B.1    Holmes Jr., D.R.2
  • 10
    • 4444294338 scopus 로고    scopus 로고
    • Structure of chemical compounds, methods of analysis and process control. Validation of HPLC techniques for pharmaceutical analysis
    • N.A. Epshtein Structure of chemical compounds, methods of analysis and process control. Validation of HPLC techniques for pharmaceutical analysis Pharm. Chem. J. 38 2004 212 228
    • (2004) Pharm. Chem. J. , vol.38 , pp. 212-228
    • Epshtein, N.A.1
  • 12
    • 0003861196 scopus 로고
    • Center for Drug Evaluation and Research (CDER)
    • FDA General Principles of Validation 1987 Center for Drug Evaluation and Research (CDER)
    • (1987) General Principles of Validation
  • 17
    • 9644308053 scopus 로고    scopus 로고
    • Analytical method validation and instrument performance verification
    • F. Garofolo Analytical method validation and instrument performance verification C.C. Chan, H. Lam, Y.C. Lee, X.-M. Zhang, Bioanalytical Method Validation 2004 John Wiley & Sons New Jersey 123 124
    • (2004) Bioanalytical Method Validation , pp. 123-124
    • Garofolo, F.1
  • 18
    • 26944435918 scopus 로고    scopus 로고
    • Method validation guidelines: Guide to bioanalytical advances
    • A.D. Kanarek Method validation guidelines: guide to bioanalytical advances BioPharm. Int. Suppl. September 2005 28 33
    • (2005) BioPharm. Int. Suppl. , Issue.SEP. , pp. 28-33
    • Kanarek, A.D.1
  • 19
    • 33845580996 scopus 로고    scopus 로고
    • Economic design of inspection procedures using guard band when measurement errors are present
    • Y.J. Kim, B.R. Cho, and N.K. Kim Economic design of inspection procedures using guard band when measurement errors are present Appl. Math. Modell. 31 2007 805 816
    • (2007) Appl. Math. Modell. , vol.31 , pp. 805-816
    • Kim, Y.J.1    Cho, B.R.2    Kim, N.K.3
  • 26
    • 0034604792 scopus 로고    scopus 로고
    • System performance and variability of chromatographic techniques used in pharmaceutical quality control
    • B. Renger System performance and variability of chromatographic techniques used in pharmaceutical quality control J. Chromatogr. B 745 2000 167 176
    • (2000) J. Chromatogr. B , vol.745 , pp. 167-176
    • Renger, B.1
  • 27
    • 55749105135 scopus 로고    scopus 로고
    • Bioabsorbable and biocompatible stents. Is a new revolution coming?
    • R. Rogacka, A. Chieffo, A. Latib, and A. Colombo Bioabsorbable and biocompatible stents. Is a new revolution coming? Minerva Cardioangiol. 56 2008 483 491
    • (2008) Minerva Cardioangiol. , vol.56 , pp. 483-491
    • Rogacka, R.1    Chieffo, A.2    Latib, A.3    Colombo, A.4
  • 31
    • 39749181623 scopus 로고    scopus 로고
    • Drug release kinetics from stent device-based delivery systems
    • B. Tesfamariam Drug release kinetics from stent device-based delivery systems J. Cardiovasc. Pharmacol. 51 2008 118 125
    • (2008) J. Cardiovasc. Pharmacol. , vol.51 , pp. 118-125
    • Tesfamariam, B.1
  • 33
    • 77950301290 scopus 로고    scopus 로고
    • New drug-eluting stent concepts
    • R. Wessely New drug-eluting stent concepts Nat. Rev. Cardiol. 7 2010 194 203
    • (2010) Nat. Rev. Cardiol. , vol.7 , pp. 194-203
    • Wessely, R.1
  • 35
    • 33745469013 scopus 로고    scopus 로고
    • Drug-eluting stents: Factors governing local pharmacokinetics
    • C. Yang, and H.M. Burt Drug-eluting stents: factors governing local pharmacokinetics Adv. Drug Deliv. Rev. 58 2006 402 411
    • (2006) Adv. Drug Deliv. Rev. , vol.58 , pp. 402-411
    • Yang, C.1    Burt, H.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.