메뉴 건너뛰기




Volumn 37, Issue 2, 2011, Pages 312-320

Are ECG Premature Complexes Induced by Ultrasonic Cavitation Electrophysiological Responses to Irreversible Cardiomyocyte Injury?

Author keywords

Arrhythmia; Cardiac myocyte necrosis; Contrast agent adverse effects; Gas body activation; Myocardial contrast echocardiography; Ultrasonic cavitation biology

Indexed keywords

ARRHYTHMIA; CARDIAC MYOCYTES; CONTRAST AGENT; MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY; ULTRASONIC CAVITATION BIOLOGY;

EID: 78751604854     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2010.11.012     Document Type: Article
Times cited : (25)

References (33)
  • 2
    • 55349132417 scopus 로고    scopus 로고
    • Cardiomyocyte death and renewal in the normal and diseased heart
    • Buja L.M., Vela D. Cardiomyocyte death and renewal in the normal and diseased heart. Cardiovasc Pathol 2008, 17:349-374.
    • (2008) Cardiovasc Pathol , vol.17 , pp. 349-374
    • Buja, L.M.1    Vela, D.2
  • 3
    • 23044467774 scopus 로고    scopus 로고
    • Incidence of cardiac arrhythmias with therapeutic versus diagnostic ultrasound and intravenous microbubbles
    • Chapman S., Windle J., Xie F., McGrain A., Porter T.R. Incidence of cardiac arrhythmias with therapeutic versus diagnostic ultrasound and intravenous microbubbles. J Ultrasound Med 2005, 24:1099-1107.
    • (2005) J Ultrasound Med , vol.24 , pp. 1099-1107
    • Chapman, S.1    Windle, J.2    Xie, F.3    McGrain, A.4    Porter, T.R.5
  • 4
    • 0030944080 scopus 로고    scopus 로고
    • Effects of pulsed ultrasound on the frog heart: III. The radiation force mechanism
    • Dalecki D., Raeman C.H., Child S.Z., Carstensen E.L. Effects of pulsed ultrasound on the frog heart: III. The radiation force mechanism. Ultrasound Med Biol 1997, 23:275-285.
    • (1997) Ultrasound Med Biol , vol.23 , pp. 275-285
    • Dalecki, D.1    Raeman, C.H.2    Child, S.Z.3    Carstensen, E.L.4
  • 5
    • 25444441165 scopus 로고    scopus 로고
    • Premature cardiac contractions produced by ultrasound and microbubble contrast agents in mice
    • Dalecki D., Rota C., Raeman C.H., Child S.Z. Premature cardiac contractions produced by ultrasound and microbubble contrast agents in mice. Acoust Res Let Online (ARLO) 2005, 6:221-226.
    • (2005) Acoust Res Let Online (ARLO) , vol.6 , pp. 221-226
    • Dalecki, D.1    Rota, C.2    Raeman, C.H.3    Child, S.Z.4
  • 6
    • 0028271384 scopus 로고
    • Biological effects of shock waves: Induction of arrhythmia in piglet hearts
    • Delius M., Hoffmann E., Steinbeck G., Conzen P. Biological effects of shock waves: Induction of arrhythmia in piglet hearts. Ultrasound Med Biol 1994, 20:279-285.
    • (1994) Ultrasound Med Biol , vol.20 , pp. 279-285
    • Delius, M.1    Hoffmann, E.2    Steinbeck, G.3    Conzen, P.4
  • 8
    • 0026794344 scopus 로고
    • Electrophysiological effects of myocardial stretch and mechanical determinants of stretch-activated arrhythmias
    • Franz M.R., Cima R., Wang D., Profitt D., Kurz R. Electrophysiological effects of myocardial stretch and mechanical determinants of stretch-activated arrhythmias. Circulation 1992, 86:968-978.
    • (1992) Circulation , vol.86 , pp. 968-978
    • Franz, M.R.1    Cima, R.2    Wang, D.3    Profitt, D.4    Kurz, R.5
  • 9
    • 1142297603 scopus 로고    scopus 로고
    • Gap junction-mediated spread of cell injury and death during myocardial ischemia-reperfusion
    • García-Dorado D., Rodríguez-Sinovas A., Ruiz-Meana M. Gap junction-mediated spread of cell injury and death during myocardial ischemia-reperfusion. Cardiovasc Res 2004, 61:386-401.
    • (2004) Cardiovasc Res , vol.61 , pp. 386-401
    • García-Dorado, D.1    Rodríguez-Sinovas, A.2    Ruiz-Meana, M.3
  • 11
    • 0022928246 scopus 로고
    • Anatomy and morphometry of myocardial capillaries studied with vascular corrosion casting and scanning electron microscopy: A method for rat heart
    • Hossler F.E., Douglas J.E., Douglas L.E. Anatomy and morphometry of myocardial capillaries studied with vascular corrosion casting and scanning electron microscopy: A method for rat heart. Scan Electron Microsc 1986, 4:1469-1475.
    • (1986) Scan Electron Microsc , vol.4 , pp. 1469-1475
    • Hossler, F.E.1    Douglas, J.E.2    Douglas, L.E.3
  • 12
    • 0026090542 scopus 로고
    • The threshold for thermally significant cavitation in dog's thigh muscle in vivo
    • Hynynen K. The threshold for thermally significant cavitation in dog's thigh muscle in vivo. Ultrasound Med Biol 1991, 17:157-169.
    • (1991) Ultrasound Med Biol , vol.17 , pp. 157-169
    • Hynynen, K.1
  • 13
    • 67349097532 scopus 로고    scopus 로고
    • A study on premature ventricular contractions caused by ultrasound exposure with microbubbles using cultured ventricular muscle cells
    • Kudo N., Yokoyama G., Ikebuchi M., Okada K., Kawahara K., Yamamoto K. A study on premature ventricular contractions caused by ultrasound exposure with microbubbles using cultured ventricular muscle cells. J Phys Conf Ser 2004, 1:118-121.
    • (2004) J Phys Conf Ser , vol.1 , pp. 118-121
    • Kudo, N.1    Yokoyama, G.2    Ikebuchi, M.3    Okada, K.4    Kawahara, K.5    Yamamoto, K.6
  • 14
    • 0021961581 scopus 로고
    • Blood volume in the rat
    • Lee H.B., Blaufox M.D. Blood volume in the rat. J Nucl Med 1985, 26:72-76.
    • (1985) J Nucl Med , vol.26 , pp. 72-76
    • Lee, H.B.1    Blaufox, M.D.2
  • 15
    • 0141750513 scopus 로고    scopus 로고
    • Impact of myocardial contrast echocardiography on vascular permeability: An in vivo dose response study of delivery mode, ultrasound power and contrast dose
    • Li P., Cao L.Q., Dou C.Y., Armstrong W.R., Miller D.L. Impact of myocardial contrast echocardiography on vascular permeability: An in vivo dose response study of delivery mode, ultrasound power and contrast dose. Ultrasound Med Biol 2003, 29:1341-1349.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 1341-1349
    • Li, P.1    Cao, L.Q.2    Dou, C.Y.3    Armstrong, W.R.4    Miller, D.L.5
  • 16
    • 1042298887 scopus 로고    scopus 로고
    • Impact of myocardial contrast echocardiography on vascular permeability: Comparison of three different contrast agents
    • Li P., Armstrong W.F., Miller D.L. Impact of myocardial contrast echocardiography on vascular permeability: Comparison of three different contrast agents. Ultrasound Med Biol 2004, 30:83-91.
    • (2004) Ultrasound Med Biol , vol.30 , pp. 83-91
    • Li, P.1    Armstrong, W.F.2    Miller, D.L.3
  • 17
    • 34249302747 scopus 로고    scopus 로고
    • Transient elastography using impulsive ultrasound radiation force: A preliminary comparison with surface palpation elastography
    • Melodelima D., Bamber J.C., Duck F.A., Shipley J.A. Transient elastography using impulsive ultrasound radiation force: A preliminary comparison with surface palpation elastography. Ultrasound Med Biol 2007, 33:959-969.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 959-969
    • Melodelima, D.1    Bamber, J.C.2    Duck, F.A.3    Shipley, J.A.4
  • 18
    • 13244273880 scopus 로고    scopus 로고
    • Histological characterization of microlesions induced by myocardial contrast echocardiography
    • Miller D.L., Li P., Gordon D., Armstrong W.F. Histological characterization of microlesions induced by myocardial contrast echocardiography. Echocardiography 2005, 22:25-34.
    • (2005) Echocardiography , vol.22 , pp. 25-34
    • Miller, D.L.1    Li, P.2    Gordon, D.3    Armstrong, W.F.4
  • 19
    • 24944508083 scopus 로고    scopus 로고
    • Influence of contrast agent dose and ultrasound exposure on cardiomyocyte injury induced by myocardial contrast echocardiography in rats
    • Miller D.L., Li P., Dou C., Gordon D., Edwards C.A., Armstrong W.F. Influence of contrast agent dose and ultrasound exposure on cardiomyocyte injury induced by myocardial contrast echocardiography in rats. Radiology 2005, 237:137-143.
    • (2005) Radiology , vol.237 , pp. 137-143
    • Miller, D.L.1    Li, P.2    Dou, C.3    Gordon, D.4    Edwards, C.A.5    Armstrong, W.F.6
  • 20
    • 33645422453 scopus 로고    scopus 로고
    • Microvascular permeabilization and cardiomyocyte injury provoked by myocardial contrast echocardiography in a canine model
    • Miller D.L., Driscoll E.M., Dou C., Armstrong W.F., Lucchesi B.R. Microvascular permeabilization and cardiomyocyte injury provoked by myocardial contrast echocardiography in a canine model. J Am Coll Cardiol 2006, 47:1464-1468.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1464-1468
    • Miller, D.L.1    Driscoll, E.M.2    Dou, C.3    Armstrong, W.F.4    Lucchesi, B.R.5
  • 21
    • 34848882754 scopus 로고    scopus 로고
    • Simulation of diagnostic ultrasound image pulse sequences in cavitation bioeffects research
    • Miller D.L., Dou C., Wiggins R.C. Simulation of diagnostic ultrasound image pulse sequences in cavitation bioeffects research. J Acoust Soc Am 2007, 122:2002-2008.
    • (2007) J Acoust Soc Am , vol.122 , pp. 2002-2008
    • Miller, D.L.1    Dou, C.2    Wiggins, R.C.3
  • 23
    • 73949151992 scopus 로고    scopus 로고
    • Cardiac arrhythmia and injury induced in rats by burst and pulsed mode ultrasound with a gas body contrast agent
    • Miller D.L., Dou C., Lucchesi B.R. Cardiac arrhythmia and injury induced in rats by burst and pulsed mode ultrasound with a gas body contrast agent. J Ultrasound Med 2009, 28:1519-1526.
    • (2009) J Ultrasound Med , vol.28 , pp. 1519-1526
    • Miller, D.L.1    Dou, C.2    Lucchesi, B.R.3
  • 24
    • 76649107880 scopus 로고    scopus 로고
    • In vivo gas body efficacy for glomerular capillary hemorrhage induced by diagnostic ultrasound in rats
    • Miller D.L., Dou C., Wiggins R.C. In vivo gas body efficacy for glomerular capillary hemorrhage induced by diagnostic ultrasound in rats. IEEE Trans Biomed Eng 2010, 57:167-174.
    • (2010) IEEE Trans Biomed Eng , vol.57 , pp. 167-174
    • Miller, D.L.1    Dou, C.2    Wiggins, R.C.3
  • 25
    • 33646441030 scopus 로고    scopus 로고
    • Tissue deformation induced by radiation force from Gaussian transducers
    • Myers M.R. Tissue deformation induced by radiation force from Gaussian transducers. J Acoust Soc Am 2006, 119:3147-3152.
    • (2006) J Acoust Soc Am , vol.119 , pp. 3147-3152
    • Myers, M.R.1
  • 26
    • 2142768187 scopus 로고    scopus 로고
    • Premature ventricular contraction during myocardial contrast echocardiography: relationship with imaging method, acoustic power and dose of contrast agent
    • Okazaki J., Ishikura F., Asanuma T., Otani K., Beppu S. Premature ventricular contraction during myocardial contrast echocardiography: relationship with imaging method, acoustic power and dose of contrast agent. J Cardiol 2004, 43:69-74.
    • (2004) J Cardiol , vol.43 , pp. 69-74
    • Okazaki, J.1    Ishikura, F.2    Asanuma, T.3    Otani, K.4    Beppu, S.5
  • 27
    • 0035184733 scopus 로고    scopus 로고
    • Myocardial cavitational activity during continuous infusion and bolus intravenous injections of perfluorocarbon-containing microbubbles
    • Porter T.R., Everbach C., Kricsfeld D., Xie F. Myocardial cavitational activity during continuous infusion and bolus intravenous injections of perfluorocarbon-containing microbubbles. J Am Soc Echocardiogr 2001, 14:618-625.
    • (2001) J Am Soc Echocardiogr , vol.14 , pp. 618-625
    • Porter, T.R.1    Everbach, C.2    Kricsfeld, D.3    Xie, F.4
  • 28
    • 33750302894 scopus 로고    scopus 로고
    • Detection of acoustic cavitation in the heart with microbubble contrast agents in vivo: a mechanism for ultrasound-induced arrhythmias
    • Rota C., Raeman C.H., Child S.Z., Dalecki D. Detection of acoustic cavitation in the heart with microbubble contrast agents in vivo: a mechanism for ultrasound-induced arrhythmias. J Acoust Soc Am 2006, 120:2958-2964.
    • (2006) J Acoust Soc Am , vol.120 , pp. 2958-2964
    • Rota, C.1    Raeman, C.H.2    Child, S.Z.3    Dalecki, D.4
  • 29
    • 0032944255 scopus 로고    scopus 로고
    • Cardiac mechano-electric feedback in man: clinical relevance
    • Taggart P., Sutton P.M. Cardiac mechano-electric feedback in man: clinical relevance. Prog Biophys Mol Biol 1999, 71:139-154.
    • (1999) Prog Biophys Mol Biol , vol.71 , pp. 139-154
    • Taggart, P.1    Sutton, P.M.2