메뉴 건너뛰기




Volumn 39, Issue 2, 2011, Pages 256-261

Freedom SOLO valve: Early- and intermediate-term results of a single centre's first 100 cases

Author keywords

Aortic valve replacement; Follow up studies; Haemodynamic; Platelets; Retrospective Studies; Stentless prostheses

Indexed keywords

ABLATION THERAPY; ADULT; AGED; AORTA VALVE PROSTHESIS; ARTICLE; CORONARY ARTERY BYPASS GRAFT; ECHOCARDIOGRAPHY; ENDOCARDITIS; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEMODYNAMICS; HUMAN; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REPLACEMENT; MORBIDITY; MUSCLE RESECTION; OPERATION DURATION; PACEMAKER; PRIORITY JOURNAL; PROSTHETIC VALVE DYSFUNCTION; REOPERATION; SCORING SYSTEM; SURGICAL MORTALITY; SURVIVAL RATE; THROMBOCYTE COUNT; THROMBOEMBOLISM;

EID: 78751591322     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2010.04.038     Document Type: Article
Times cited : (18)

References (18)
  • 1
    • 33646184788 scopus 로고    scopus 로고
    • Continuous suture technique for freedom stentless valve reduced crossclamp time
    • Beholz S., Dushe S., Konertz W. Continuous suture technique for freedom stentless valve reduced crossclamp time. Asian Cardiovasc Thorac Ann 2006, 14(2):128-133.
    • (2006) Asian Cardiovasc Thorac Ann , vol.14 , Issue.2 , pp. 128-133
    • Beholz, S.1    Dushe, S.2    Konertz, W.3
  • 2
    • 26844501573 scopus 로고    scopus 로고
    • Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up a large retrospective study
    • Borger M.A., Carson S.M., Ivanov J., Rao V., Scully H.E., Feindel C.M., David T.E. Stentless aortic valves are hemodynamically superior to stented valves during mid-term follow-up a large retrospective study. Ann Thorac Surg 2005, 80(6):2180-2185.
    • (2005) Ann Thorac Surg , vol.80 , Issue.6 , pp. 2180-2185
    • Borger, M.A.1    Carson, S.M.2    Ivanov, J.3    Rao, V.4    Scully, H.E.5    Feindel, C.M.6    David, T.E.7
  • 6
    • 0029858898 scopus 로고    scopus 로고
    • Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ad Hoc Liaison Committee for Standardizing Definitions of Prosthetic Heart Valve Morbidity of The American Association for Thoracic Surgery and The Society of Thoracic Surgeons
    • Edmunds L.H., Clark R.E., Cohn L.H., Grunkemeier G.L., Miller D.C., Weisel R.D. Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ad Hoc Liaison Committee for Standardizing Definitions of Prosthetic Heart Valve Morbidity of The American Association for Thoracic Surgery and The Society of Thoracic Surgeons. J Thorac Cardiovasc Surg 1996, 112(3):708-711.
    • (1996) J Thorac Cardiovasc Surg , vol.112 , Issue.3 , pp. 708-711
    • Edmunds, L.H.1    Clark, R.E.2    Cohn, L.H.3    Grunkemeier, G.L.4    Miller, D.C.5    Weisel, R.D.6
  • 8
    • 33846894285 scopus 로고    scopus 로고
    • Stentless valves for aortic valve replacement where do we stand?
    • de Kerchove L., Glineur D., El Khoury G., Noirhomme P. Stentless valves for aortic valve replacement where do we stand?. Curr Opin Cardiol 2007, 22(2):96-103.
    • (2007) Curr Opin Cardiol , vol.22 , Issue.2 , pp. 96-103
    • de Kerchove, L.1    Glineur, D.2    El Khoury, G.3    Noirhomme, P.4
  • 9
    • 33645410064 scopus 로고    scopus 로고
    • The subcoronary Toronto stentless versus supra-annular Perimount stented replacement aortic valve early clinical and hemodynamic results of a randomized comparison in 160 patients
    • Chambers J.B., Rimington H.M., Hodson F., Rajani R., Blauth C.I. The subcoronary Toronto stentless versus supra-annular Perimount stented replacement aortic valve early clinical and hemodynamic results of a randomized comparison in 160 patients. J Thorac Cardiovasc Surg 2006, 131(4):878-882.
    • (2006) J Thorac Cardiovasc Surg , vol.131 , Issue.4 , pp. 878-882
    • Chambers, J.B.1    Rimington, H.M.2    Hodson, F.3    Rajani, R.4    Blauth, C.I.5
  • 10
    • 33846917531 scopus 로고    scopus 로고
    • The Freedom SOLO valve superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement
    • Beholz S., Dushe S., Konertz W. The Freedom SOLO valve superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement. J Heart Valve Dis 2007, 16(1):49-55.
    • (2007) J Heart Valve Dis , vol.16 , Issue.1 , pp. 49-55
    • Beholz, S.1    Dushe, S.2    Konertz, W.3
  • 12
    • 0031966129 scopus 로고    scopus 로고
    • Hemodynamic comparison by Doppler echocardiography of valve in the aortic position value of the continuity equation to assess prosthetic dysfunction
    • Peteiro J., Campos V., Valle J., Alvarez N., Castro-Beiras A. Hemodynamic comparison by Doppler echocardiography of valve in the aortic position value of the continuity equation to assess prosthetic dysfunction. Echocardiography 1998, 15(4):325-336.
    • (1998) Echocardiography , vol.15 , Issue.4 , pp. 325-336
    • Peteiro, J.1    Campos, V.2    Valle, J.3    Alvarez, N.4    Castro-Beiras, A.5
  • 14
    • 0018104133 scopus 로고
    • The problem of valve prosthesis-patient mismatch
    • Rahimtoola S.H. The problem of valve prosthesis-patient mismatch. Circulation 1978, 58(1):20-24.
    • (1978) Circulation , vol.58 , Issue.1 , pp. 20-24
    • Rahimtoola, S.H.1
  • 15
    • 58149386005 scopus 로고    scopus 로고
    • Differences in the recovery of platelet counts after biological aortic valve replacement
    • Hilker L., Wodny M., Ginesta M., Wollert H.G., Eckel L. Differences in the recovery of platelet counts after biological aortic valve replacement. Interact Cardiovasc Thorac Surg 2009, 8(1):70-73.
    • (2009) Interact Cardiovasc Thorac Surg , vol.8 , Issue.1 , pp. 70-73
    • Hilker, L.1    Wodny, M.2    Ginesta, M.3    Wollert, H.G.4    Eckel, L.5
  • 16
    • 58149402038 scopus 로고    scopus 로고
    • EComment Lower postoperative platelet levels after aortic valve replacement with Freedom Solo prostheses are there clinical repercussions?
    • Piccardo A., Caus T. eComment Lower postoperative platelet levels after aortic valve replacement with Freedom Solo prostheses are there clinical repercussions?. Interact Cardiovasc Thorac Surg 2009, 8(1):73.
    • (2009) Interact Cardiovasc Thorac Surg , vol.8 , Issue.1 , pp. 73
    • Piccardo, A.1    Caus, T.2
  • 17
    • 58149374186 scopus 로고    scopus 로고
    • EComment Freedom Solo stentless aortic bioprosthesis and postoperative thrombocytopenia interpretation of available data and clinical consequences for surgeons
    • Yerebakan C., Westphal B., Steinhoff G., Liebold A. eComment Freedom Solo stentless aortic bioprosthesis and postoperative thrombocytopenia interpretation of available data and clinical consequences for surgeons. Interact Cardiovasc Thorac Surg 2009, 8(1):73-74.
    • (2009) Interact Cardiovasc Thorac Surg , vol.8 , Issue.1 , pp. 73-74
    • Yerebakan, C.1    Westphal, B.2    Steinhoff, G.3    Liebold, A.4