메뉴 건너뛰기




Volumn 15, Issue 4, 1998, Pages 325-335

Hemodynamic comparison by doppler echocardiography of valves in the aortic position: Value of the continuity equation to assess prosthetic dysfunction

Author keywords

Aortic prostheses; Doppler echocardiography; Prosthetic obstruction; Toronto valve

Indexed keywords

ADULT; AGED; AORTA VALVE PROSTHESIS; ARTICLE; CONTROLLED STUDY; DOPPLER ECHOCARDIOGRAPHY; FEMALE; HEART LEFT VENTRICLE CONTRACTILITY; HEART RATE; HEART STROKE VOLUME; HEMODYNAMICS; HUMAN; MAJOR CLINICAL STUDY; MALE; MORPHOLOGY; PRIORITY JOURNAL; SYSTOLIC BLOOD PRESSURE;

EID: 0031966129     PISSN: 07422822     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8175.1998.tb00613.x     Document Type: Article
Times cited : (7)

References (28)
  • 1
    • 0024312662 scopus 로고
    • Doppler color flow imaging in the evaluation of prosthetic mitral and aortic valve function
    • Kapur KK, Fan P, Nanda N, et al: Doppler color flow imaging in the evaluation of prosthetic mitral and aortic valve function. J Am Coll Cardiol 1989;13:1561-1571.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 1561-1571
    • Kapur, K.K.1    Fan, P.2    Nanda, N.3
  • 2
    • 13344289488 scopus 로고
    • Doppler evaluation of bioprosthetic and mechanical aortic valves: Data from four models in 109 stable,ambulatory patients
    • Ramirez ML, Wong MM, Sadler N, et al: Doppler evaluation of bioprosthetic and mechanical aortic valves: Data from four models in 109 stable,ambulatory patients. Am Heart J 1988;115:418-425.
    • (1988) Am Heart J , vol.115 , pp. 418-425
    • Ramirez, M.L.1    Wong, M.M.2    Sadler, N.3
  • 3
    • 0024466667 scopus 로고
    • Continuous wave Doppler measurements of prosthetic valve gradients: A simultaneous Doppler-catheter correlative study
    • Burstow DJ, Nishimura RA, Bailey KR, et al: Continuous wave Doppler measurements of prosthetic valve gradients: A simultaneous Doppler-catheter correlative study. Circulation 1989;80:504-514.
    • (1989) Circulation , vol.80 , pp. 504-514
    • Burstow, D.J.1    Nishimura, R.A.2    Bailey, K.R.3
  • 4
    • 84912658183 scopus 로고
    • Pulsed and continuous wave Doppler examination in prosthetic valves: Correlation with clinical and catheterization data
    • Rothbart RM, Smucker MI, Gibson RS: Pulsed and continuous wave Doppler examination in prosthetic valves: Correlation with clinical and catheterization data. (Abstract) Circulation 1985;75(Suppl III):III-373.
    • (1985) Circulation , vol.75 , Issue.3 SUPPL.
    • Rothbart, R.M.1    Smucker, M.I.2    Gibson, R.S.3
  • 5
    • 0022619333 scopus 로고
    • Doppler echocardiographic evaluation of Hancock and Bjork Shiley prosthetic valves
    • Sagar KB, Wann LS, Paulsen WHJ, et al: Doppler echocardiographic evaluation of Hancock and Bjork Shiley prosthetic valves. J Am Coll Cardiol 1986;7:681-687.
    • (1986) J Am Coll Cardiol , vol.7 , pp. 681-687
    • Sagar, K.B.1    Wann, L.S.2    Paulsen, W.H.J.3
  • 6
    • 0021875340 scopus 로고
    • Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Bjork-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves
    • Williams GA,Lavobitz AJ: Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Bjork-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves. Am J Cardiol 1985;56:25-32.
    • (1985) Am J Cardiol , vol.56 , pp. 25-32
    • Williams, G.A.1    Lavobitz, A.J.2
  • 7
    • 0021027654 scopus 로고
    • Ultrasonic assessment of the St Jude prosthetic valve: M-mode,two-dimensional and Doppler echocardiography
    • Weinstein I, Malberg J, Perez J: Ultrasonic assessment of the St Jude prosthetic valve: M-mode,two-dimensional and Doppler echocardiography. Circulation 1983;68:897-905.
    • (1983) Circulation , vol.68 , pp. 897-905
    • Weinstein, I.1    Malberg, J.2    Perez, J.3
  • 8
    • 1842291110 scopus 로고
    • Normal aortic valve prostheses hemodynamics: 609 prospective Doppler examinations
    • Miller FA, Callhan JA, Taylor et al: Normal aortic valve prostheses hemodynamics: 609 prospective Doppler examinations. (Abstract) Circulation 1989;80(Suppl II):II-169.
    • (1989) Circulation , vol.80 , Issue.2 SUPPL.
    • Miller, F.A.1    Callhan, J.A.2    Taylor3
  • 9
    • 0026717861 scopus 로고
    • Hemodynamic evaluation by Doppler echocardiography of small (≤ 21 mm) prostheses and bioprostheses in the aortic valve position
    • Wiseth R, Levang OW, Sande E, et al: Hemodynamic evaluation by Doppler echocardiography of small (≤ 21 mm) prostheses and bioprostheses in the aortic valve position. Am J Cardiol 1992;70:240-246.
    • (1992) Am J Cardiol , vol.70 , pp. 240-246
    • Wiseth, R.1    Levang, O.W.2    Sande, E.3
  • 10
    • 0029092899 scopus 로고
    • Echocardiographic assessment of aortic valve replacement with stentless porcine xenografts
    • Meloni L, Richi A, Cirio E, et al: Echocardiographic assessment of aortic valve replacement with stentless porcine xenografts. Am J Cardiol 1995;76:294-296.
    • (1995) Am J Cardiol , vol.76 , pp. 294-296
    • Meloni, L.1    Richi, A.2    Cirio, E.3
  • 11
    • 0025346848 scopus 로고
    • Determination of aortic valve by two-dimensional echocardiography in patients with normal and stenotic bioprosthetic valves
    • Rothbart RM, Castriz JL, Harding LV, et al: Determination of aortic valve by two-dimensional echocardiography in patients with normal and stenotic bioprosthetic valves. J Am Coll Cardiol 1990;15:8117-8124.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 8117-8124
    • Rothbart, R.M.1    Castriz, J.L.2    Harding, L.V.3
  • 12
    • 0022355265 scopus 로고
    • Noninvasive assessment of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography
    • Skajaerpe T, Hegrenaes L, Hatle L: Noninvasive assessment of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography. Circulation 1985;72:810-818.
    • (1985) Circulation , vol.72 , pp. 810-818
    • Skajaerpe, T.1    Hegrenaes, L.2    Hatle, L.3
  • 13
    • 0027276475 scopus 로고
    • Doppler echocardiographic assessment of the Bjork-Shiley Monostrut valve prosthesis in the aortic position
    • Peteiro J, Hidalgo R, Aparici M, et al: Doppler echocardiographic assessment of the Bjork-Shiley Monostrut valve prosthesis in the aortic position. Echocardiography 1993;10:235-246.
    • (1993) Echocardiography , vol.10 , pp. 235-246
    • Peteiro, J.1    Hidalgo, R.2    Aparici, M.3
  • 14
    • 0023139362 scopus 로고
    • Evaluation of aortic insufficiency by Doppler color flow mapping
    • Perry GP, Helmcke F, Nanda NC, et al: Evaluation of aortic insufficiency by Doppler color flow mapping. J Am Coll Cardiol 1987;9:952-959.
    • (1987) J Am Coll Cardiol , vol.9 , pp. 952-959
    • Perry, G.P.1    Helmcke, F.2    Nanda, N.C.3
  • 15
    • 0019394948 scopus 로고
    • Hemodynamic alterations induced by isoproterenol and pacing after aortic valve replacement with the Bjork-Shiley or St Jude Medical prosthesis
    • Thormann J, Gottwik M, Schlepper M, et al: Hemodynamic alterations induced by isoproterenol and pacing after aortic valve replacement with the Bjork-Shiley or St Jude Medical prosthesis. Circulation 1981;63:895-904.
    • (1981) Circulation , vol.63 , pp. 895-904
    • Thormann, J.1    Gottwik, M.2    Schlepper, M.3
  • 16
    • 0024535070 scopus 로고
    • The Gorlin formula against directly observed orifice area in porcine mitral bioprosthesis
    • Chambers JB, Cochrane T, Black MM, et al: The Gorlin formula against directly observed orifice area in porcine mitral bioprosthesis. J Am Coll Cardiol 1989;13:348-353.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 348-353
    • Chambers, J.B.1    Cochrane, T.2    Black, M.M.3
  • 17
    • 0025726819 scopus 로고
    • Validity of an early postoperative baseline Doppler recording after aortic valve replacement
    • Wiseth R, Hegrenaes L, Rossvoll O, et al: Validity of an early postoperative baseline Doppler recording after aortic valve replacement. Am J Cardiol 1991;67:869-872.
    • (1991) Am J Cardiol , vol.67 , pp. 869-872
    • Wiseth, R.1    Hegrenaes, L.2    Rossvoll, O.3
  • 18
    • 0026734733 scopus 로고
    • Performance of a stentless xenograft aortic bioprosthesis up to four years after implantation
    • Hofig M, Nellessen U, Mahmoodi M, et al: Performance of a stentless xenograft aortic bioprosthesis up to four years after implantation. J Thorac Cardiovasc Surg 1992;103:1068-1073.
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 1068-1073
    • Hofig, M.1    Nellessen, U.2    Mahmoodi, M.3
  • 19
    • 0028110091 scopus 로고
    • Aortic valve replacement with a stentless porcine aortic valve: A six-year experience
    • Dvaid TE, Feindel CM, Boss J, et al: Aortic valve replacement with a stentless porcine aortic valve: A six-year experience. J Thorac Cardiovasc Surg 1994;108:1030-1036.
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 1030-1036
    • Dvaid, T.E.1    Feindel, C.M.2    Boss, J.3
  • 20
    • 0023910781 scopus 로고
    • Six months postoperative hemodynamics of the Hancock heterograft and the Bjork-Shiley prosthesis: Results of a Veterans Administration cooperative prospective randomized trial
    • Khuri SF, Folland ED, Sethi GK, et al: Six months postoperative hemodynamics of the Hancock heterograft and the Bjork-Shiley prosthesis: Results of a Veterans Administration cooperative prospective randomized trial. J Am Coll Cardiol 1988;12:8-18.
    • (1988) J Am Coll Cardiol , vol.12 , pp. 8-18
    • Khuri, S.F.1    Folland, E.D.2    Sethi, G.K.3
  • 21
    • 0026527253 scopus 로고
    • Hemodynamic evaluation of the Carbomedics prosthetic heart valve in the aortic position: Comparison of noninvasive and invasive techniques
    • Ihlen H, Molstad P, Simonsen S, et al: Hemodynamic evaluation of the Carbomedics prosthetic heart valve in the aortic position: Comparison of noninvasive and invasive techniques. Am Heart J 1992;123:151-159.
    • (1992) Am Heart J , vol.123 , pp. 151-159
    • Ihlen, H.1    Molstad, P.2    Simonsen, S.3
  • 22
    • 0027499532 scopus 로고
    • Echocardiographic description of the Carbomedics Bileaflet prosthetic heart valve
    • Chambers J, Cross J, Deverall P, et al: Echocardiographic description of the Carbomedics Bileaflet prosthetic heart valve. J Am Coll Cardiol 1993;21:398-405.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 398-405
    • Chambers, J.1    Cross, J.2    Deverall, P.3
  • 23
    • 0029041074 scopus 로고
    • Doppler-derived gradients in normally functioning Bjork-Shiley prostheses
    • Pons-LLado G, Carreras F, Borras X, et al: Doppler-derived gradients in normally functioning Bjork-Shiley prostheses. Am J Cardiol 1995;76:100-103.
    • (1995) Am J Cardiol , vol.76 , pp. 100-103
    • Pons-LLado, G.1    Carreras, F.2    Borras, X.3
  • 24
    • 0026512411 scopus 로고
    • Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: An in vitro study of normal St Jude, Medtronic-Hall, Starr-Edwards and Hancock valves
    • Baumgartner H, Khan S, DeRobertis M, et al: Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: An in vitro study of normal St Jude, Medtronic-Hall, Starr-Edwards and Hancock valves. J Am Coll Cardiol 1992;19:324-332.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 324-332
    • Baumgartner, H.1    Khan, S.2    DeRobertis, M.3
  • 25
    • 0026734686 scopus 로고
    • Doppler assessment of prosthetic valve orifice area: An in vitro study
    • Baumgartner H, Khan S, DeRobertis M, et al: Doppler assessment of prosthetic valve orifice area: An in vitro study. Circulation 1992;85: 2275-2283.
    • (1992) Circulation , vol.85 , pp. 2275-2283
    • Baumgartner, H.1    Khan, S.2    DeRobertis, M.3
  • 26
    • 0025552864 scopus 로고
    • Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro: A manifestation of localized gradients and pressure recovery
    • Baumgartner H, Khan S, DeRobertis M, et al: Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro: A manifestation of localized gradients and pressure recovery. Circulation 1990;82:1467-1475.
    • (1990) Circulation , vol.82 , pp. 1467-1475
    • Baumgartner, H.1    Khan, S.2    DeRobertis, M.3
  • 27
    • 0024624362 scopus 로고
    • Doppler echocardiography: Application to the assessment of successful thrombolysis of prosthetic valve thrombosis
    • Zoghbi WA, Desir RM, Rosen L, et al: Doppler echocardiography: Application to the assessment of successful thrombolysis of prosthetic valve thrombosis. J Am Soc Echocardiogr 1989;2:98-101.
    • (1989) J Am Soc Echocardiogr , vol.2 , pp. 98-101
    • Zoghbi, W.A.1    Desir, R.M.2    Rosen, L.3
  • 28
    • 7144226831 scopus 로고
    • Determination of cardiac output by Doppler echocardiography
    • Berger M (ed): New York, Marcel Dekker
    • Williams GA: Determination of cardiac output by Doppler echocardiography. In Berger M (ed): Doppler Echocardiography in Heart Disease. New York, Marcel Dekker, 1987, p. 107.
    • (1987) Doppler Echocardiography in Heart Disease , pp. 107
    • Williams, G.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.