메뉴 건너뛰기




Volumn , Issue , 2010, Pages 384-389

Numerical simulation for blood flow in Internal Carotid Artery for integration with photoelastic stress analysis

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD FLOW; FLOW SPEED; HIGH STRESS; INTERNAL CAROTID ARTERY; ISOTROPIC ELASTIC MEDIUM; MISES STRESS; NUMERICAL SIMULATION; PHOTOELASTIC STRESS ANALYSIS; VELOCITY PROFILES; VESSEL WALLS; WALL SHEAR STRESS; YOUNG'S MODULUS;

EID: 78751533867     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MHS.2010.5669515     Document Type: Conference Paper
Times cited : (4)

References (14)
  • 1
    • 0032506614 scopus 로고    scopus 로고
    • Unruptured Intracranial Aneurysms-Risk ofRupture and Risks of Surgical Intervention
    • The International Study of Unruptured Intracranial Ameurysms Investigation
    • The International Study of Unruptured Intracranial Ameurysms Investigation "Unruptured Intracranial Aneurysms-Risk ofRupture and Risks of Surgical Intervention", N. Engl. J. Med. 339, ppl725-1733,1998
    • (1998) N. Engl. J. Med. , vol.339 , pp. 1725-1733
  • 2
    • 0026062435 scopus 로고
    • Cerebral blood flow patterns at major vessel bifurcations and aneurysm in rats
    • Nakatani H, Hashimoto N, Kang Y. Cerebral blood flow patterns at major vessel bifurcations and aneurysm in rats. J Neurosurg 1991; 74:258-262
    • (1991) J Neurosurg , vol.74 , pp. 258-262
    • Nakatani, H.1    Hashimoto, N.2    Kang, Y.3
  • 3
    • 0026607672 scopus 로고
    • Intracranial aneurysms: Flow analysis of their origin and progression
    • Gonzalez CF, Choi Y I, Ortega V. "Intracranial aneurysms: flow analysis of their origin and progression." AJNR Am J Neuroradiol 1992; 13:181-188.
    • (1992) AJNR Am J Neuroradiol , vol.13 , pp. 181-188
    • Gonzalez, C.F.1    Choi, Y.I.2    Ortega, V.3
  • 5
    • 0028028448 scopus 로고
    • In vitro study of haemodynamics in a giant saccular aneurysm model: Influence of flow dynamics in the parent vessel and effects of coil embolisation
    • DOI 10.1007/BF00593516
    • Gobin Y P, Counard JL, Flaud P. "In vitro study of haemodynamics in agiant saccular aneurysm model: influence of flow dynamics in the parentvessel and effects of coil embolization." Neuroradiology 1994; 36:530-536. (Pubitemid 24316504)
    • (1994) Neuroradiology , vol.36 , Issue.7 , pp. 530-536
    • Gobin, Y.P.1    Counord, J.L.2    Flaud, P.3    Duffaux, J.4
  • 7
    • 0035199676 scopus 로고    scopus 로고
    • Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using computerized tomography angiogram as a mold
    • Tateshima S, Murayama Y, Villablanca JP. "Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using computerized tomography angiogram as a mold." J Neurosurg 2001; 95: 1020-1027.
    • (2001) J Neurosurg , vol.95 , pp. 1020-1027
    • Tateshima, S.1    Murayama, Y.2    Villablanca, J.P.3
  • 8
    • 33845650658 scopus 로고    scopus 로고
    • An in vitro patient specifIc biological model of the cerebral artery reproduced with a membraous confIguration for simulating endvascular intervention
    • S. Ikeda, F. Arai, T. Uchiyama, T. Fukuda, M. Negoro, and K. Irie, " An in vitro patient specifIc biological model of the cerebral artery reproduced with a membraous confIguration for simulating endvascular intervention", J.Robot. Mechanics, vol. 17, no.3, pp. 327-333, 2005
    • (2005) J.Robot. Mechanics , vol.17 , Issue.3 , pp. 327-333
    • Ikeda, S.1    Arai, F.2    Uchiyama, T.3    Fukuda, T.4    Negoro, M.5    Irie, K.6
  • 9
    • 78751516405 scopus 로고    scopus 로고
    • Image Processing for Sensing Guide Wire Behaviour during Endovascular Surgery Simulation
    • C. Tercero, S. Ikeda, T. Fukuda, M. Negoro, "Image Processing for Sensing Guide Wire Behaviour during Endovascular Surgery Simulation." ROBOTIK, pp 716-721, 2010
    • (2010) ROBOTIK , pp. 716-721
    • Tercero, C.1    Ikeda, S.2    Fukuda, T.3    Negoro, M.4
  • 10
    • 77955227024 scopus 로고    scopus 로고
    • Photoelastic Stress Analysis Error Quantification in Vasculature Models for Robot Feedback Control
    • C. Tercero, S. Ikeda, M. Matsushima, T. Fukuda, M. Negoro, "Photoelastic Stress Analysis Error Quantification in Vasculature Models for Robot Feedback Control," IEEE/ASME Trans. on Mechatronics, Vol.15:4, pp 520-526, 2010.
    • (2010) IEEE/ASME Trans. on Mechatronics , vol.15 , Issue.4 , pp. 520-526
    • Tercero, C.1    Ikeda, S.2    Matsushima, M.3    Fukuda, T.4    Negoro, M.5
  • 12
    • 0033485806 scopus 로고    scopus 로고
    • Hemodynamic shear stress and its role in atherosclerosis
    • A.M. Malek, S.L. Alper, S. Izumo, "Hemodynamic shear stress and its role in atherosclerosis." J. Am. Med. Assoc. 282 (1999) 2035-2042.
    • (1999) J. Am. Med. Assoc. , vol.282 , pp. 2035-2042
    • Malek, A.M.1    Alper, S.L.2    Izumo, S.3
  • 14
    • 0021128207 scopus 로고    scopus 로고
    • Cerebral aneurysms and variations of the circle of Willis
    • Kayembe KNT, Sasahara M, Hazama F. "Cerebral aneurysms and variations of the circle of Willis." Stroke, 15:846-50
    • Stroke , vol.15 , pp. 846-850
    • Kayembe, K.N.T.1    Sasahara, M.2    Hazama, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.