메뉴 건너뛰기




Volumn 2, Issue 3, 2010, Pages 397-405

Development of 2D chiral chromatography with accelerator mass spectrometry for quantification of 14C-labeled R- and S-verapamil in plasma

Author keywords

[No Author keywords available]

Indexed keywords

CARBON 14; VERAPAMIL; CARBON;

EID: 78751497334     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.10.7     Document Type: Article
Times cited : (4)

References (22)
  • 1
    • 33645036518 scopus 로고    scopus 로고
    • The Phase 0 microdosing concept
    • Garner RC, Lappin G. The Phase 0 microdosing concept. Br. J. Clin. Pharmacol. 61(4), 367-370 (2006).
    • (2006) Br. J. Clin. Pharmacol. , vol.61 , Issue.4 , pp. 367-370
    • Garner, R.C.1    Lappin, G.2
  • 3
    • 33644827201 scopus 로고    scopus 로고
    • Guidance for industry investigators and reviewers
    • US FDA US Department of Health and Human Services
    • US FDA. US Department of Health and Human Services. Guidance for industry investigators and reviewers. Exploratory IND Studies (2006).
    • (2006) Exploratory IND Studies
  • 4
    • 77951883582 scopus 로고    scopus 로고
    • New ultrasensitive detection technologies and techniques for use in microdosing studies
    • Lappin G, Wagner C, Langer O, Merbel VD. New ultrasensitive detection technologies and techniques for use in microdosing studies. Bioanalysis 1(2), 357-366 (2009).
    • (2009) Bioanalysis , vol.1 , Issue.2 , pp. 357-366
    • Lappin, G.1    Wagner, C.2    Langer, O.3    Merbel, V.D.4
  • 5
    • 0033059135 scopus 로고    scopus 로고
    • Biomedical applications of accelerator mass spectrometry-isotope measurements at the level of the atom
    • DOI 10.1002/(SICI)1097-0231(19990228)13:4<285::AID-RCM469>3.0.CO;2- R
    • Barker J, Garner RC. Biomedical applications of accelerator mass spectrometry-isotope measurements at the level of the atom. Rapid Commun. Mass Spectrom. 13(4), 285-293(1999). (Pubitemid 29101097)
    • (1999) Rapid Communications in Mass Spectrometry , vol.13 , Issue.4 , pp. 285-293
    • Barker, J.1    Garner, R.C.2
  • 6
    • 84978896432 scopus 로고    scopus 로고
    • Biomedical accelerator mass spectrometry
    • Taylor Francis, Boca Raton, USA
    • Lappin GJ. Biomedical accelerator mass spectrometry. Radiotracers Drug Dev. Taylor Francis, Boca Raton, USA (2006).
    • (2006) Radiotracers Drug Dev
    • Lappin, G.J.1
  • 7
    • 79952462634 scopus 로고    scopus 로고
    • Microdosing: A valuable tool for accelerating drug development and the role of bioanalytical methods in meeting the challenge
    • Ings R. Microdosing: a valuable tool for accelerating drug development and the role of bioanalytical methods in meeting the challenge. Bioanalysis 1(7), 1293-1305(2009).
    • (2009) Bioanalysis , vol.1 , Issue.7 , pp. 1293-1305
    • Ings, R.1
  • 8
    • 58149188094 scopus 로고    scopus 로고
    • The utility of microdosing over the past 5 years
    • Lappin G, Garner C. The utility of microdosing over the past 5 years. Expert Opin. Drug Metab. Toxicol. 4(12), 1499-1506 (2008).
    • (2008) Expert Opin. Drug Metab. Toxicol. , vol.4 , Issue.12 , pp. 1499-1506
    • Lappin, G.1    Garner, C.2
  • 10
    • 0035098868 scopus 로고    scopus 로고
    • A comprehensive account on the role of efflux transporters in the gastrointestinal absorption of 13 commonly used substrate drugs in humans
    • Chiou WL, Chung SM, Wu TC, Ma C. A comprehensive account on the role of efflux transporters in the gastrointestinal absorption of 13commonly used substrate drugs in humans. Int. J. Clin. Pharmacol. Ther. 39(3), 93-101 (2001). (Pubitemid 32208536)
    • (2001) International Journal of Clinical Pharmacology and Therapeutics , vol.39 , Issue.3 , pp. 93-101
    • Chiou, W.L.1    Chung, S.M.2    Wu, T.C.3    Ma, C.4
  • 11
    • 60149111433 scopus 로고    scopus 로고
    • Comparison of a 250 kV single-stage accelerator mass spectrometer with a 5MV tandem accelerator mass spectrometer - Fitness for purpose in bioanalysis
    • Young GC, Corless S, Felgate CC, Colthup PV. Comparison of a 250 kV single-stage accelerator mass spectrometer with a 5MV tandem accelerator mass spectrometer - fitness for purpose in bioanalysis. Rapid Commun. Mass Spectrom. 22(24), 4035-4042 (2008).
    • (2008) Rapid Commun. Mass Spectrom. , vol.22 , Issue.24 , pp. 4035-4042
    • Young, G.C.1    Corless, S.2    Felgate, C.C.3    Colthup, P.V.4
  • 12
    • 43849103059 scopus 로고    scopus 로고
    • High-performance liquid chromatography accelerator mass spectrometry: Correcting for losses during analysis by internal standardization
    • Lappin G, Simpson M, Shishikura Y, Garner C. High-performance liquid chromatography accelerator mass spectrometry: correcting for losses during analysis by internal standardization. Anal. Biochem. 378, 93-95(2008).
    • (2008) Anal. Biochem. , vol.378 , pp. 93-95
    • Lappin, G.1    Simpson, M.2    Shishikura, Y.3    Garner, C.4
  • 13
    • 62949126634 scopus 로고    scopus 로고
    • A pharmacokinetic evaluation of five H1 antagonists after an oral and intravenous microdose to human subjects
    • Madan A, O'brien Z, Wen J et al. A pharmacokinetic evaluation of five H1 antagonists after an oral and intravenous microdose to human subjects. Br. J. Clin. Pharmacol. 67(3), 288-298 (2008).
    • (2008) Br. J. Clin. Pharmacol. , vol.67 , Issue.3 , pp. 288-298
    • Madan, A.1    O'brien, Z.2    Wen, J.3
  • 14
    • 0000677819 scopus 로고
    • Rapid production of graphite without contamination for biomedical AMS
    • Vogel JS. Rapid production of graphite without contamination for biomedical AMS. Radiocarbon 34, 344-350 (1992).
    • (1992) Radiocarbon , vol.34 , pp. 344-350
    • Vogel, J.S.1
  • 18
    • 0035001504 scopus 로고    scopus 로고
    • A validated method for the determination of verapamil and norverapamil in human plasma
    • DOI 10.1016/S0731-7085(00)00585-9, PII S0731708500005859
    • Sawicki W. A validated method for the determination of verapamil and norverapamil in human plasma. J. Pharm. Biomed. Anal. 25(3-4), 689-695(2001). (Pubitemid 32493927)
    • (2001) Journal of Pharmaceutical and Biomedical Analysis , vol.25 , Issue.3-4 , pp. 689-695
    • Sawicki, W.1
  • 19
    • 0034830621 scopus 로고    scopus 로고
    • Accelerator mass spectrometry (AMS): Recent experience of its use in a clinical study and the potential future of the technique
    • DOI 10.1080/00498250110052724
    • Young G, Ellis W, Ayrton J, Hussey E, Adamkiewicz B. Accelerator mass spectrometry (AMS): recent experience of its use in a clinical study and the potential future of the technique. Xenobiotica 31(8-9), 619-632 (2001). (Pubitemid 32826395)
    • (2001) Xenobiotica , vol.31 , Issue.8-9 , pp. 619-632
    • Young, G.1    Ellis, W.2    Ayrton, J.3    Hussey, E.4    Adamkiewicz, B.5
  • 20
    • 71449119505 scopus 로고    scopus 로고
    • Microdose pharmacokinetics of IDX899 and IDX989, candidate HIV-1 non-nucleoside reverse transcriptase inhibitors, following oral and intravenous administration in healthy male subjects
    • Zhou J, Garner RC, Nicholson S, Kissling CJ, Mayers D. Microdose pharmacokinetics of IDX899 and IDX989, candidate HIV-1 non-nucleoside reverse transcriptase inhibitors, following oral and intravenous administration in healthy male subjects. J. Clin. Pharmacol. 49(12), 1408-1416 (2009).
    • (2009) J. Clin. Pharmacol. , vol.49 , Issue.12 , pp. 1408-1416
    • Zhou, J.1    Garner, R.C.2    Nicholson, S.3    Kissling, C.J.4    Mayers, D.5
  • 21
    • 33750626722 scopus 로고    scopus 로고
    • The effect of gender on the pharmacokinetics of verapamil and norverapamil in human
    • DOI 10.1002/bdd.512
    • Dadashzadeh S, Javadian B, Sadeghian S. The effect of gender on the pharmacokinetics of verapamil and norverapamil in human. Biopharm. Drug Dispos. 27(7), 329-334 (2006). (Pubitemid 44687786)
    • (2006) Biopharmaceutics and Drug Disposition , vol.27 , Issue.7 , pp. 329-334
    • Dadashzadeh, S.1    Javadian, B.2    Sadeghian, S.3
  • 22
    • 0021287002 scopus 로고
    • Pharmacokinetics of (+)-, (-)- and (+/-)-verapamil after intravenous administration
    • Eichelbaum M, Mikus G, Vogelgesang B. Pharmacokinetics of (+)-, (-)- and (+/-)-verapamil after intravenous administration. Br. J. Clin. Pharmacol. 17(4), 453-458 (1984).
    • (1984) Br. J. Clin. Pharmacol. , vol.17 , Issue.4 , pp. 453-458
    • Eichelbaum, M.1    Mikus, G.2    Vogelgesang, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.