메뉴 건너뛰기




Volumn 34, Issue 8, 2010, Pages 155-159

DC flashover characteristics of epoxy resin insulator with and without fillers under different SF6 gas pressures

Author keywords

DC flashover characteristic; Epoxy resin insulator; Flashover voltage; Surface charge accumulation; Surface conductivity; Time constant

Indexed keywords

DC FLASHOVER CHARACTERISTIC; FLASHOVER VOLTAGE; SURFACE CHARGE ACCUMULATION; SURFACE CONDUCTIVITY; TIME CONSTANTS;

EID: 78651566370     PISSN: 10003673     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (19)
  • 1
    • 44449141239 scopus 로고    scopus 로고
    • Introduction of ±800 kV HVDC transmission standards system
    • (in Chinese)
    • Fan Jianbin, Yu Yongqing, Liu Zehong, et al. Introduction of ±800 kV HVDC transmission standards system[J]. Power System Technology, 2006, 30(7):1-6(in Chinese).
    • (2006) Power System Technology , vol.30 , Issue.7 , pp. 1-6
    • Fan, J.1    Yu, Y.2    Liu, Z.3
  • 5
    • 84954461098 scopus 로고    scopus 로고
    • Gas insulated transmission lines (GIL): ready for the real world
    • Singapore
    • Hillers T. Gas insulated transmission lines (GIL): ready for the real world[C]. Power Engineering Society Winter Meeting, Singapore, 2000.
    • (2000) Power Engineering Society Winter Meeting
    • Hillers, T.1
  • 6
    • 21644434243 scopus 로고    scopus 로고
    • Discussion on several important problems of developing UHV AC transmission in China
    • (in Chinese)
    • Zhou Hao, Yu Yuhong. Discussion on several important problems of developing UHV AC transmission in China[J]. Power System Technology, 2005, 29(12):1-9(in Chinese).
    • (2005) Power System Technology , vol.29 , Issue.12 , pp. 1-9
    • Zhou, H.1    Yu, Y.2
  • 7
    • 12344294879 scopus 로고    scopus 로고
    • Recent development trend of gas insulated switchgear
    • (in Chinese)
    • Wang Feng, Qiu Yuchang. Recent development trend of gas insulated switchgear[J]. Power System Technology, 2003, 27(2):54-57(in Chinese).
    • (2003) Power System Technology , vol.27 , Issue.2 , pp. 54-57
    • Wang, F.1    Qiu, Y.2
  • 8
    • 70349177978 scopus 로고    scopus 로고
    • Insulation design of gas insulated HVDC transmission line
    • (in Chinese)
    • Tang Hao, Wu Guangning, Fan Jianbin, et al. Insulation design of gas insulated HVDC transmission line[J]. Power System Technology, 2008, 32(6):65-70(in Chinese).
    • (2008) Power System Technology , vol.32 , Issue.6 , pp. 65-70
    • Tang, H.1    Wu, G.2    Fan, J.3
  • 10
    • 12344281673 scopus 로고    scopus 로고
    • Dielectric strength coordination and generalized spacer design rules for HVAC/DC SF6 gas insulated systems
    • Volpov E K. Dielectric strength coordination and generalized spacer design rules for HVAC/DC SF6 gas insulated systems[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2004, 11(6): 949-963.
    • (2004) IEEE Transactions on Dielectrics and Electrical Insulation , vol.11 , Issue.6 , pp. 949-963
    • Volpov, E.K.1
  • 12
    • 44449136066 scopus 로고    scopus 로고
    • Study on key technology of ±800 kV UHVDC GIL
    • (in Chinese)
    • Fan Janbin, Li Peng, Li Jinzhong, et al. Study on key technology of ±800 kV UHVDC GIL[J]. Proceedings of the CSEE, 2008, 28(13): 1-7(in Chinese).
    • (2008) Proceedings of the CSEE , vol.28 , Issue.13 , pp. 1-7
    • Fan, J.1    Li, P.2    Li, J.3
  • 13
    • 78651539321 scopus 로고    scopus 로고
    • Study on application ultra-high frequency (UHF) measuring partial discharge of 1100 kV GIS device
    • (in Chinese)
    • Lu Peng, Fang Yuying, Liu Xu. Study on application ultra-high frequency (UHF) measuring partial discharge of 1100 kV GIS device [J]. Electric Power Construction, 2009, 30(6):33-35(in Chinese).
    • (2009) Electric Power Construction , vol.30 , Issue.6 , pp. 33-35
    • Lu, P.1    Fang, Y.2    Liu, X.3
  • 15
    • 33847723086 scopus 로고    scopus 로고
    • Phenomena and mechanism of electric charges on spacers in gas insulated switchgears
    • Okabe S. Phenomena and mechanism of electric charges on spacers in gas insulated switchgears[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2007, 14(1):46-52.
    • (2007) IEEE Transactions on Dielectrics and Electrical Insulation , vol.14 , Issue.1 , pp. 46-52
    • Okabe, S.1
  • 16
    • 0035314394 scopus 로고    scopus 로고
    • Analysis of charge accumulation at dielectric interface
    • (in Chinese)
    • Wang Feng, Xiao Dengming, Chen Qingguo, et al. Analysis of charge accumulation at dielectric interface[J]. Journal of Xi'an Jiaotong University, 2001, 35(4):347-350(in Chinese).
    • (2001) Journal of Xi'an Jiaotong University , vol.35 , Issue.4 , pp. 347-350
    • Wang, F.1    Xiao, D.2    Chen, Q.3
  • 17
    • 15744368196 scopus 로고    scopus 로고
    • Study of charge accumulation on insulator surface in HVDC gas-insulated switchgear
    • (in Chinese)
    • Wang Feng, Fang Zhi, Qiu Yuchang. Study of charge accumulation on insulator surface in HVDC gas-insulated switchgear[J]. Proceedings of the CSEE, 2005, 25(3):105-109(in Chinese).
    • (2005) Proceedings of the CSEE , vol.25 , Issue.3 , pp. 105-109
    • Wang, F.1    Fang, Z.2    Qiu, Y.3
  • 19
    • 0036505555 scopus 로고    scopus 로고
    • HVDC gas insulated apparatus: electric field specificity and insulation design concept
    • Volpov E K. HVDC gas insulated apparatus: electric field specificity and insulation design concept[J]. IEEE Electrical Insulation Magazine, 2002, 18(2):7-36.
    • (2002) IEEE Electrical Insulation Magazine , vol.18 , Issue.2 , pp. 7-36
    • Volpov, E.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.