메뉴 건너뛰기




Volumn 97, Issue 3, 2010, Pages 501-506

Comparison of DVH parameters and loading patterns of standard loading, manual and inverse optimization for intracavitary brachytherapy on a subset of tandem/ovoid cases

Author keywords

Brachytherapy; Cervix cancer; Treatment planning

Indexed keywords

ARTICLE; BRACHYTHERAPY; CLINICAL ARTICLE; DOSIMETRY; EXTERNAL BEAM RADIOTHERAPY; FEMALE; HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RADIATION DOSE; TREATMENT PLANNING; UTERINE CERVIX CANCER;

EID: 78651517540     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2010.08.011     Document Type: Article
Times cited : (41)

References (31)
  • 1
    • 0022624359 scopus 로고
    • Radiation therapy alone in the treatment of carcinoma of the uterine cervix: A 20 year experience
    • C.A. Perez, H.M. Camel, and R.R. Kuske Radiation therapy alone in the treatment of carcinoma of the uterine cervix: a 20 year experience Gynecol Oncol 23 1986 127 140
    • (1986) Gynecol Oncol , vol.23 , pp. 127-140
    • Perez, C.A.1    Camel, H.M.2    Kuske, R.R.3
  • 2
    • 0001416583 scopus 로고
    • A dosage system for use in the treatment of cancer of the uterine cervix
    • M.C. Tod, and W.J. Meredith A dosage system for use in the treatment of cancer of the uterine cervix Br J Radiol 11 1938 809 824
    • (1938) Br J Radiol , vol.11 , pp. 809-824
    • Tod, M.C.1    Meredith, W.J.2
  • 4
    • 0002473131 scopus 로고
    • The stepping source dosimetry system as an extension of the Paris system
    • R. Van der Laarse The stepping source dosimetry system as an extension of the Paris system R.F. Mould, J.J. Battermann, A.A. Martinez, Brachytherapy from radium to optimization 1994 Nucletron International B.V. Veenendaal 342
    • (1994) Brachytherapy from Radium to Optimization , pp. 342
    • Van Der Laarse, R.1
  • 5
  • 6
    • 0035010591 scopus 로고    scopus 로고
    • Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function
    • E. Lessard, and J. Pouliot Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function Med Phys 28 2001 773 779
    • (2001) Med Phys , vol.28 , pp. 773-779
    • Lessard, E.1    Pouliot, J.2
  • 7
    • 20044389263 scopus 로고    scopus 로고
    • Recommendations from Gynaecological (GYN) GEC-ESTRO working group (I): Concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV
    • C. Haie-Meder, R. Pötter, and E. Van Limbergen Recommendations from Gynaecological (GYN) GEC-ESTRO working group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV Radiother Oncol 74 2005 235 245
    • (2005) Radiother Oncol , vol.74 , pp. 235-245
    • Haie-Meder, C.1    Pötter, R.2    Van Limbergen, E.3
  • 8
    • 70350486915 scopus 로고    scopus 로고
    • Direct reconstruction of the Vienna applicator on MRI images
    • D. Berger, J. Dimopoulos, R. Pötter, and C. Kirisits Direct reconstruction of the Vienna applicator on MRI images Radiother Oncol 93 2009 347 351
    • (2009) Radiother Oncol , vol.93 , pp. 347-351
    • Berger, D.1    Dimopoulos, J.2    Pötter, R.3    Kirisits, C.4
  • 9
    • 1142304255 scopus 로고    scopus 로고
    • Update of AAPM Taskgroup No. 43 report. A revised AAPM protocol for Brachytherapy dose calculations
    • M.J. Rivard, B.M. Coursey, and L.A. DeWerd Update of AAPM Taskgroup No. 43 report. A revised AAPM protocol for Brachytherapy dose calculations Med Phys 31 2004 663 674
    • (2004) Med Phys , vol.31 , pp. 663-674
    • Rivard, M.J.1    Coursey, B.M.2    Dewerd, L.A.3
  • 10
    • 70350488183 scopus 로고    scopus 로고
    • HIPO: A hybrid inverse treatment planning optimization algorithm in HDR brachytherapy
    • A. Karabis, S. Giannouli, and D. Baltas HIPO: a hybrid inverse treatment planning optimization algorithm in HDR brachytherapy Radiother Oncol 76 2005 S29
    • (2005) Radiother Oncol , vol.76 , pp. 29
    • Karabis, A.1    Giannouli, S.2    Baltas, D.3
  • 11
    • 31144452943 scopus 로고    scopus 로고
    • Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy - 3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology
    • R. Pötter, C. Haie-Meder, E.V. Limbergen, I. Barillot, M.D. Brabandere, and J. Dimopoulos Recommendations from gynaecological (GYN) GEC ESTRO working group (II): concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy - 3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology Radiother Oncol 78 2006 67 77
    • (2006) Radiother Oncol , vol.78 , pp. 67-77
    • Pötter, R.1    Haie-Meder, C.2    Limbergen, E.V.3    Barillot, I.4    Brabandere, M.D.5    Dimopoulos, J.6
  • 12
    • 20344407033 scopus 로고    scopus 로고
    • Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer
    • C. Kirisits, R. Pötter, and S. Lang Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer Int J Radiat Oncol Biol Phys 62 2005 901 911
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 901-911
    • Kirisits, C.1    Pötter, R.2    Lang, S.3
  • 13
    • 34548473370 scopus 로고    scopus 로고
    • Treatment planning for MRI assisted brachytherapy of gynaecologic malignancies based on total dose constraints
    • S. Lang, C. Kirisits, J. Dimopoulos, D. Georg, and R. Pötter Treatment planning for MRI assisted brachytherapy of gynaecologic malignancies based on total dose constraints Int J Radiat Oncol Biol Phys 69 2007 619 627
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 619-627
    • Lang, S.1    Kirisits, C.2    Dimopoulos, J.3    Georg, D.4    Pötter, R.5
  • 14
    • 27144453701 scopus 로고    scopus 로고
    • 3D inverse treatment planning for the tandem and ovoid applicator in cervical cancer
    • K. DeWitt, I.C. Hsu, and J. Speight 3D inverse treatment planning for the tandem and ovoid applicator in cervical cancer Int J Radiat Oncol Biol Phys 63 2005 1270 1274
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 1270-1274
    • Dewitt, K.1    Hsu, I.C.2    Speight, J.3
  • 15
    • 34548663099 scopus 로고    scopus 로고
    • Inverse planning approach for 3-D MRI-based pulse-dose rate intracavitary brachytherapy in cervix cancer
    • E. Chojan, I. Domas, and M. Touleimat Inverse planning approach for 3-D MRI-based pulse-dose rate intracavitary brachytherapy in cervix cancer Int J Radiat Oncol Biol Phys 69 2007 955 961
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 955-961
    • Chojan, E.1    Domas, I.2    Touleimat, M.3
  • 16
    • 0028982650 scopus 로고
    • Impact of optimized treatment planning for tandem and ring and tandem and ovoids using high dose rate brachytherapy for cervical cancer
    • W.R. Noyes, N.E. Peters, and B.R. Thomadsen Impact of optimized treatment planning for tandem and ring and tandem and ovoids using high dose rate brachytherapy for cervical cancer Int J Radiat Oncol Biol Phys 31 1995 79 86
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , pp. 79-86
    • Noyes, W.R.1    Peters, N.E.2    Thomadsen, B.R.3
  • 17
    • 29244465064 scopus 로고    scopus 로고
    • CT-guided intracavitary radiotherapy for cervical cancer: Comparison of conventional point a plan with clinical target volume-based three-dimensional plan using dose-volume parameters
    • K.H. Shin, T.H. Kim, and J.K. Cho CT-guided intracavitary radiotherapy for cervical cancer: comparison of conventional point a plan with clinical target volume-based three-dimensional plan using dose-volume parameters Int J Radiat Oncol Biol Phys 64 2006 197 204
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 197-204
    • Shin, K.H.1    Kim, T.H.2    Cho, J.K.3
  • 18
    • 25844495797 scopus 로고    scopus 로고
    • Cervical brachytherapy utilizing ring applicator: Comparison of standard and conformal loading
    • S. Brooks, P. Bownes, and J. Lowe Cervical brachytherapy utilizing ring applicator: comparison of standard and conformal loading Int J Radiat Oncol Biol Phys 63 2005 934 939
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 934-939
    • Brooks, S.1    Bownes, P.2    Lowe, J.3
  • 19
    • 49149085806 scopus 로고    scopus 로고
    • Potential of dose optimization in MRI based PDR brachytherapy of cervix carcinoma
    • M. De Brabandere, A.G. Mousa, and A. Nulens Potential of dose optimization in MRI based PDR brachytherapy of cervix carcinoma Radiother Oncol 88 2008 217 226
    • (2008) Radiother Oncol , vol.88 , pp. 217-226
    • De Brabandere, M.1    Mousa, A.G.2    Nulens, A.3
  • 20
    • 44449163974 scopus 로고    scopus 로고
    • MRI-guided 3D optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer
    • J.C. Lindegaard, K. Tanderup, and S.K. Nielsen MRI-guided 3D optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer Int J Radiat Oncol Biol Phys 71 2008 756 764
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 756-764
    • Lindegaard, J.C.1    Tanderup, K.2    Nielsen, S.K.3
  • 21
    • 33646233996 scopus 로고    scopus 로고
    • The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: Design, application, treatment planning and dosimetric results
    • C. Kirisits, S. Lang, and J. Dimopoulos The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning and dosimetric results Int J Radiat Oncol Biol Phys 65 2006 624 630
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 624-630
    • Kirisits, C.1    Lang, S.2    Dimopoulos, J.3
  • 22
    • 0035915742 scopus 로고    scopus 로고
    • HDR brachytherapy applied to cervical carcinoma with moderate lateral expansion: Modified principles of treatment
    • T. Kuipers, C.J.M. Koekstra, and A. van't Riet HDR brachytherapy applied to cervical carcinoma with moderate lateral expansion: modified principles of treatment Radiother Oncol 58 2001 25 30
    • (2001) Radiother Oncol , vol.58 , pp. 25-30
    • Kuipers, T.1    Koekstra, C.J.M.2    Van'T Riet, A.3
  • 23
    • 77549087532 scopus 로고    scopus 로고
    • From point A to the sculpted pear: MR image guidance significantly improves tumour dose and sparing of organs at risk in brachytherapy of cervical cancer
    • K. Tanderup, S.K. Nielson, and G.B. Nyvang From point A to the sculpted pear: MR image guidance significantly improves tumour dose and sparing of organs at risk in brachytherapy of cervical cancer Radiother Oncol 94 2010 173 180
    • (2010) Radiother Oncol , vol.94 , pp. 173-180
    • Tanderup, K.1    Nielson, S.K.2    Nyvang, G.B.3
  • 24
    • 70350511420 scopus 로고    scopus 로고
    • New inverse planning technology for image-guided cervical cancer brachytherapy: Description and evaluation with in a clinical frame
    • P. Trnkova, R. Pötter, and D. Baltas New inverse planning technology for image-guided cervical cancer brachytherapy: description and evaluation with in a clinical frame Radiother Oncol 93 2009 331 340
    • (2009) Radiother Oncol , vol.93 , pp. 331-340
    • Trnkova, P.1    Pötter, R.2    Baltas, D.3
  • 25
    • 46149116302 scopus 로고    scopus 로고
    • Image-guided adaptive brachytherapy for cervix carcinoma
    • R. Pötter, E. Fidarova, C. Kirisits, and J. Dimopoulos Image-guided adaptive brachytherapy for cervix carcinoma Clin Oncol 20 2008 426 432
    • (2008) Clin Oncol , vol.20 , pp. 426-432
    • Pötter, R.1    Fidarova, E.2    Kirisits, C.3    Dimopoulos, J.4
  • 26
    • 0142217886 scopus 로고    scopus 로고
    • Unique role of proximal rectal dose in late rectal complications for patients with cervical cancer undergoing high-dose-rate intracavitary brachytherapy
    • J.C. Cheng, L.C. Peng, and Y.H. Chen Unique role of proximal rectal dose in late rectal complications for patients with cervical cancer undergoing high-dose-rate intracavitary brachytherapy Int J Radiat Oncol Biol Phys 57 2003 1010 1018
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1010-1018
    • Cheng, J.C.1    Peng, L.C.2    Chen, Y.H.3
  • 27
    • 85008377656 scopus 로고    scopus 로고
    • Additional upper rectal and/or recto sigmoid mucosal points and doses in high dose rate intracavitary brachytherapy for carcinoma of the cervix - A dosimetric study [Abstract]
    • M. Umesh, M. Tiwana, and S.V. Jamema Additional upper rectal and/or recto sigmoid mucosal points and doses in high dose rate intracavitary brachytherapy for carcinoma of the cervix - a dosimetric study [Abstract] Brachytherapy 7 2008 149
    • (2008) Brachytherapy , vol.7 , pp. 149
    • Umesh, M.1    Tiwana, M.2    Jamema, S.V.3
  • 28
    • 44449138113 scopus 로고    scopus 로고
    • Dose volume parameters in cervical cancer patients treated with MRI based brachytherapy and their predictive value for late adverse side effects in rectum, sigmoid and bladder [Abstract]
    • P. Georg, J. Dimopoulos, and C. Kirisits Dose volume parameters in cervical cancer patients treated with MRI based brachytherapy and their predictive value for late adverse side effects in rectum, sigmoid and bladder [Abstract] Radiother Oncol 81 2006 S38 S39
    • (2006) Radiother Oncol , vol.81
    • Georg, P.1    Dimopoulos, J.2    Kirisits, C.3
  • 29
    • 34548864717 scopus 로고    scopus 로고
    • Sigmoid colon an unexpected organ at risk in brachytherapy for cervix cancer
    • H. Al-Booz, I. Boiangiu, and H. Appleby Sigmoid colon an unexpected organ at risk in brachytherapy for cervix cancer Egypt Natl Canc Inst 18 2006 156 160
    • (2006) Egypt Natl Canc Inst , vol.18 , pp. 156-160
    • Al-Booz, H.1    Boiangiu, I.2    Appleby, H.3
  • 30
    • 70350511420 scopus 로고    scopus 로고
    • New inverse planning technology for image-guided cervical cancer brachytherapy: Description and evaluation within a clinical frame
    • P. Trnkova, R. Pötter, and D. Baltas New inverse planning technology for image-guided cervical cancer brachytherapy: description and evaluation within a clinical frame Radiother Oncol 93 2009 331 340
    • (2009) Radiother Oncol , vol.93 , pp. 331-340
    • Trnkova, P.1    Pötter, R.2    Baltas, D.3
  • 31
    • 33947496319 scopus 로고    scopus 로고
    • Uncertainties in assessment of the vaginal dose for intracavitary brachytherapy of cervical cancer using a tandem-ring applicator
    • D. Berger, J. Dimopoulos, P. Georg, D. Georg, R. Pötter, and C. Kirisits Uncertainties in assessment of the vaginal dose for intracavitary brachytherapy of cervical cancer using a tandem-ring applicator Int J Radiat Oncol Biol Phys 67 2007 1451 1459
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1451-1459
    • Berger, D.1    Dimopoulos, J.2    Georg, P.3    Georg, D.4    Pötter, R.5    Kirisits, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.