메뉴 건너뛰기




Volumn 93, Issue 2, 2009, Pages 347-351

Direct reconstruction of the Vienna applicator on MR images

Author keywords

Applicator reconstruction; Brachytherapy; Cervical cancer; Modern treatment planning systems; Vienna ring applicator

Indexed keywords

ARTICLE; BRACHYTHERAPY; CANCER RADIOTHERAPY; DOSE CALCULATION; FEASIBILITY STUDY; FEMALE; GEOMETRY; HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIATION APPLICATOR; RADIATION DOSE; TREATMENT PLANNING; UTERINE CERVIX CANCER;

EID: 70350486915     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2009.07.002     Document Type: Article
Times cited : (47)

References (19)
  • 1
    • 0035915779 scopus 로고    scopus 로고
    • Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects
    • Fellner C., Potter R., Knocke T.H., and Wambersie A. Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects. Radiother Oncol 58 (2001) 53-62
    • (2001) Radiother Oncol , vol.58 , pp. 53-62
    • Fellner, C.1    Potter, R.2    Knocke, T.H.3    Wambersie, A.4
  • 2
    • 20344407033 scopus 로고    scopus 로고
    • Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer
    • Kirisits C., Potter R., Lang S., et al. Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer. Int J Radiat Oncol Biol Phys 62 (2005) 901-911
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 901-911
    • Kirisits, C.1    Potter, R.2    Lang, S.3
  • 3
    • 20044389263 scopus 로고    scopus 로고
    • Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV
    • Haie-Meder C., Potter R., Van Limbergen E., et al. Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV. Radiother Oncol 74 (2005) 235-245
    • (2005) Radiother Oncol , vol.74 , pp. 235-245
    • Haie-Meder, C.1    Potter, R.2    Van Limbergen, E.3
  • 4
    • 31144452943 scopus 로고    scopus 로고
    • Recommendations from gynaecological (GYN) GEC ESTRO working group (II): concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology
    • Pötter R., Haie-Meder C., Van Limbergen E., et al. Recommendations from gynaecological (GYN) GEC ESTRO working group (II): concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology. Radiother Oncol 78 (2006) 67-77
    • (2006) Radiother Oncol , vol.78 , pp. 67-77
    • Pötter, R.1    Haie-Meder, C.2    Van Limbergen, E.3
  • 5
    • 34547746023 scopus 로고    scopus 로고
    • Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation
    • Hellebust T.P., Tanderup K., Bergstrand E.S., et al. Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation. Phys Med Biol 52 (2007) 4893-4904
    • (2007) Phys Med Biol , vol.52 , pp. 4893-4904
    • Hellebust, T.P.1    Tanderup, K.2    Bergstrand, E.S.3
  • 6
    • 34548663099 scopus 로고    scopus 로고
    • Inverse planning approach for 3-D MRI-based pulse-dose rate intracavitary brachytherapy in cervix cancer
    • Chajon E., Dumas I., Touleimat M., et al. Inverse planning approach for 3-D MRI-based pulse-dose rate intracavitary brachytherapy in cervix cancer. Int J Radiat Oncol Biol Phys 69 (2007) 955-961
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 955-961
    • Chajon, E.1    Dumas, I.2    Touleimat, M.3
  • 7
    • 65449176362 scopus 로고    scopus 로고
    • Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer
    • Haack S., Nielsen S.K., Lindegaard J.C., et al. Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer. Radiother Oncol 91 (2009) 187-193
    • (2009) Radiother Oncol , vol.91 , pp. 187-193
    • Haack, S.1    Nielsen, S.K.2    Lindegaard, J.C.3
  • 8
    • 65449162208 scopus 로고    scopus 로고
    • Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning
    • Perez-Calatayud J., Kuipers F., Ballester F., et al. Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning. Radiother Oncol 91 (2009) 181-186
    • (2009) Radiother Oncol , vol.91 , pp. 181-186
    • Perez-Calatayud, J.1    Kuipers, F.2    Ballester, F.3
  • 9
    • 33746832046 scopus 로고    scopus 로고
    • The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: clinical feasibility and preliminary results
    • Dimopoulos J.C., Kirisits C., Petric P., et al. The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: clinical feasibility and preliminary results. Int J Radiat Oncol Biol Phys 66 (2006) 83-90
    • (2006) Int J Radiat Oncol Biol Phys , vol.66 , pp. 83-90
    • Dimopoulos, J.C.1    Kirisits, C.2    Petric, P.3
  • 10
    • 33646233996 scopus 로고    scopus 로고
    • The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning, and dosimetric results
    • Kirisits C., Lang S., Dimopoulos J., et al. The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning, and dosimetric results. Int J Radiat Oncol Biol Phys 65 (2006) 624-630
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 624-630
    • Kirisits, C.1    Lang, S.2    Dimopoulos, J.3
  • 11
    • 0035101317 scopus 로고    scopus 로고
    • Aspects of MR image distortions in radiotherapy treatment planning
    • Fransson A., Andreo P., and Potter R. Aspects of MR image distortions in radiotherapy treatment planning. Strahlenther Onkol 177 (2001) 59-73
    • (2001) Strahlenther Onkol , vol.177 , pp. 59-73
    • Fransson, A.1    Andreo, P.2    Potter, R.3
  • 12
    • 0023706523 scopus 로고
    • Technique and individual afterloading treatment planning simulating classic Stockholm brachytherapy for cervix cancer
    • Löffler E., and van der Laarse R. Technique and individual afterloading treatment planning simulating classic Stockholm brachytherapy for cervix cancer. Sonderb Strahlenther Onkol 82 (1988) 83-89
    • (1988) Sonderb Strahlenther Onkol , vol.82 , pp. 83-89
    • Löffler, E.1    van der Laarse, R.2
  • 13
    • 0024345718 scopus 로고
    • A comparison of dose calculations at points around an intracavitary cervix applicator
    • Meertens H. A comparison of dose calculations at points around an intracavitary cervix applicator. Radiother Oncol 15 (1989) 199-206
    • (1989) Radiother Oncol , vol.15 , pp. 199-206
    • Meertens, H.1
  • 14
    • 17844378466 scopus 로고    scopus 로고
    • Comparison between CT-based volumetric calculations and ICRU reference-point estimates of radiation doses delivered to bladder and rectum during intracavitary radiotherapy for cervical cancer
    • Pelloski C.E., Palmer M., Chronowski G.M., et al. Comparison between CT-based volumetric calculations and ICRU reference-point estimates of radiation doses delivered to bladder and rectum during intracavitary radiotherapy for cervical cancer. Int J Radiat Oncol Biol Phys 62 (2005) 131-137
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 131-137
    • Pelloski, C.E.1    Palmer, M.2    Chronowski, G.M.3
  • 15
    • 0141521412 scopus 로고    scopus 로고
    • On the use of C-arm fluoroscopy for treatment planning in high dose rate brachytherapy
    • Liu L., Bassano D.A., Prasad S.C., et al. On the use of C-arm fluoroscopy for treatment planning in high dose rate brachytherapy. Med Phys 30 (2003) 2297-2302
    • (2003) Med Phys , vol.30 , pp. 2297-2302
    • Liu, L.1    Bassano, D.A.2    Prasad, S.C.3
  • 16
    • 0037086342 scopus 로고    scopus 로고
    • PET-guided three-dimensional treatment planning of intracavitary gynecologic implants
    • Mutic S., Grigsby P.W., Low D.A., et al. PET-guided three-dimensional treatment planning of intracavitary gynecologic implants. Int J Radiat Oncol Biol Phys 52 (2002) 1104-1110
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1104-1110
    • Mutic, S.1    Grigsby, P.W.2    Low, D.A.3
  • 17
    • 34548382663 scopus 로고    scopus 로고
    • Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems
    • Kirisits C., Siebert F.A., Baltas D., et al. Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems. Radiother Oncol 84 (2007) 290-297
    • (2007) Radiother Oncol , vol.84 , pp. 290-297
    • Kirisits, C.1    Siebert, F.A.2    Baltas, D.3
  • 18
    • 0030872705 scopus 로고    scopus 로고
    • Reconstruction accuracy of a dedicated localiser for filmless planning in intra-operative brachytherapy
    • Kolkman-Deurloo I.K., Visser A.G., Idzes M.H., and Levendag P.C. Reconstruction accuracy of a dedicated localiser for filmless planning in intra-operative brachytherapy. Radiother Oncol 44 (1997) 73-81
    • (1997) Radiother Oncol , vol.44 , pp. 73-81
    • Kolkman-Deurloo, I.K.1    Visser, A.G.2    Idzes, M.H.3    Levendag, P.C.4
  • 19
    • 31144456088 scopus 로고    scopus 로고
    • The EQUAL-ESTRO audit on geometric reconstruction techniques in brachytherapy
    • Roue A., Ferreira I.H., Van Dam J., et al. The EQUAL-ESTRO audit on geometric reconstruction techniques in brachytherapy. Radiother Oncol 78 (2006) 78-83
    • (2006) Radiother Oncol , vol.78 , pp. 78-83
    • Roue, A.1    Ferreira, I.H.2    Van Dam, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.